Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Minerva Endocrinol ; 38(3): 281-7, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24126548

RESUMEN

Thyroid abscess is a relatively rare yet dramatic condition of the thyroid gland requiring immediate therapeutic intervention. Traditionally, more or less aggressive surgical approaches and administration of broad-spectrum antibiotics have been used. Clinically less severe disease allows non-surgical treatment as well. The case report describes successful treatment of a large abscess of iatrogenic origin after biopsy of a cystic cavity. A combination of broad-spectrum antibiotics was used based on culture results, administered both orally and by repeated application directly into the abscess cavity using an ultrasound-guided fine-needle approach. Concurrent repeated evacuation of the cavity replaced drainage. Ultimately, a small residual cavity with sterile contents was managed by sclerotization with absolute alcohol. Clinical condition permitting, thyroid abscess may be successfully treated by repeated application of a targeted antibiotic, using a fine needle and ultrasound guidance, directly into the abscess cavity, with repeated evacuation replacing drainage.


Asunto(s)
Absceso/terapia , Antibacterianos/uso terapéutico , Ciprofloxacina/uso terapéutico , Enterobacter , Infecciones por Enterobacteriaceae/terapia , Etanol/uso terapéutico , Gentamicinas/uso terapéutico , Soluciones Esclerosantes/uso terapéutico , Escleroterapia , Enfermedades de la Tiroides/terapia , Ultrasonografía Intervencional , Absceso/diagnóstico por imagen , Absceso/tratamiento farmacológico , Absceso/etiología , Absceso/microbiología , Adulto , Antibacterianos/administración & dosificación , Biopsia con Aguja Fina/efectos adversos , Ciprofloxacina/administración & dosificación , Terapia Combinada , Quistes/patología , Enterobacter/aislamiento & purificación , Infecciones por Enterobacteriaceae/diagnóstico por imagen , Infecciones por Enterobacteriaceae/tratamiento farmacológico , Infecciones por Enterobacteriaceae/etiología , Infecciones por Enterobacteriaceae/microbiología , Etanol/administración & dosificación , Femenino , Gentamicinas/administración & dosificación , Humanos , Soluciones Esclerosantes/administración & dosificación , Enfermedades de la Tiroides/diagnóstico por imagen , Enfermedades de la Tiroides/tratamiento farmacológico , Enfermedades de la Tiroides/etiología , Enfermedades de la Tiroides/microbiología , Traqueotomía , Infección de Heridas/diagnóstico por imagen , Infección de Heridas/tratamiento farmacológico , Infección de Heridas/etiología , Infección de Heridas/microbiología , Infección de Heridas/terapia
2.
Kyobu Geka ; 65(10): 899-902, 2012 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-22940663

RESUMEN

Preoperative computed tomography( CT)-guided marking with a short hook wire for small sized lung tumors has become popular along with the spread of thoracoscopic surgery. Systemic arterial air embolism is a very rare but potentially fatal complication. The patient was a 79-year-old man who was found to have a mixed ground glass opacity shadow on chest CT. Almost immediately after marking, he lost consciousness and complete atrio-ventricular (AV) block was found on the electrocardiogram (ECG) monitor. Brain CT showed intravascular air bubbles in the right frontal lobe. Two hours later, his conscious level was recovered completely but remained left hemiplegia. Five hours later, he was transported to another hospital for hyperbaric oxygen therapy. After 3 episodes of the treatment, left hemiplegia recovered with slight sense disorder in the left little finger. When neurologic findings are remained after air embolism, hyperbaric oxygen therapy should be arranged immediately.


Asunto(s)
Biopsia con Aguja Fina/efectos adversos , Biopsia con Aguja Fina/métodos , Embolia Aérea/etiología , Embolia Aérea/terapia , Oxigenoterapia Hiperbárica , Tomografía Computarizada por Rayos X , Anciano , Bloqueo Atrioventricular/etiología , Hemiplejía/etiología , Hemiplejía/terapia , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino
3.
Korean J Radiol ; 10(5): 441-6, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19721828

RESUMEN

OBJECTIVE: This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. MATERIALS AND METHODS: A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). RESULTS: The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was administered. Four patients had an equivalent pain score for both treatments. This finding was also statistically significant (p = 0.001). CONCLUSION: In our study, patient pain scales were significantly lower when no local anesthesia was used prior to US-FNABs of thyroid nodules as compared to when local anesthesia was administered. Therefore, we believe that when one needle puncture is used, US-FNAB should be performed without administering local anesthesia.


Asunto(s)
Anestesia Local/estadística & datos numéricos , Biopsia con Aguja Fina/efectos adversos , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/patología , Ultrasonografía Intervencional , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Estudios Prospectivos , Punciones/efectos adversos , Estadísticas no Paramétricas , Neoplasias de la Tiroides/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen
4.
Artículo en Inglés | WPRIM | ID: wpr-72780

RESUMEN

OBJECTIVE: This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. MATERIALS AND METHODS: A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). RESULTS: The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was administered. Four patients had an equivalent pain score for both treatments. This finding was also statistically significant (p = 0.001). CONCLUSION: In our study, patient pain scales were significantly lower when no local anesthesia was used prior to US-FNABs of thyroid nodules as compared to when local anesthesia was administered. Therefore, we believe that when one needle puncture is used, US-FNAB should be performed without administering local anesthesia.


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anestesia Local/estadística & datos numéricos , Biopsia con Aguja Fina/efectos adversos , Dimensión del Dolor , Estudios Prospectivos , Punciones/efectos adversos , Estadísticas no Paramétricas , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/patología , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA