Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Métodos Terapéuticos y Terapias MTCI
Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Talanta ; 81(1-2): 578-85, 2010 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-20188965

RESUMEN

A new, simple and sensitive method by combining headspace Pd(II)-coated graphite bar microextraction (GBME) with electrothermal vaporization-inductively coupled plasma mass spectrometry (ETV-ICP-MS) was developed for the determination of trace Se, Te and Bi in seawater and human hair. In this method, the graphite bar was coated with Pd(II) and then used for headspace trapping of the hydrides of Se(IV), Te(IV) and Bi(III). The graphite bar with enriched hydrides of analytes was inserted directly into the graphite tube and subsequently determined by ETV-ICP-MS according to the established temperature program. The experimental parameters, which may affect the extraction and vaporization of target analytes, were systematically investigated and the optimal experimental conditions were established. Under the optimal conditions, the detection limits of the method were 8.6, 2.6 and 0.2 ng l(-1) and the relative standard deviations (RSDs) were 7.0%, 6.2% and 8.0% (C=0.20 microg l(-1), n=7) for Se, Te and Bi, respectively. Linearity was obtained over the range of 0.05-20.00, 0.01-5.00 and 0.01-20.00 microg l(-1) with the correlation coefficients of 0.9942, 0.9997 and 0.9976 for Se, Te and Bi, respectively. The proposed method was successfully applied for the determination of trace Se, Te and Bi in seawater and human hair samples. In order to validate the method, the proposed method has also been applied for the determination of trace Se, Te and Bi in the certified material of GBW07601 human hair, and the determined values were in good agreement with the certified values.


Asunto(s)
Fraccionamiento Químico/métodos , Grafito/química , Cabello/química , Paladio/química , Agua de Mar/química , Adsorción , Bismuto/análisis , Bismuto/aislamiento & purificación , Borohidruros/química , Humanos , Concentración de Iones de Hidrógeno , Espectrometría de Masas , Selenio/análisis , Selenio/aislamiento & purificación , Telurio/análisis , Telurio/aislamiento & purificación , Temperatura , Factores de Tiempo , Volatilización
2.
Talanta ; 76(4): 724-30, 2008 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-18656648

RESUMEN

A simple and robust flow injection system which permits low sample and reagent consumption is described for rapid and reliable hydride generation atomic absorption spectrometric determination of selenium, arsenic and bismuth. The system, which composed of one peristaltic pump and one four channel solenoid valve, used water as the carrier streams for both sample and NaBH(4) solution. Rapid off-line pre-reduction of the analytes was achieved by using hydroxylamine hydrochloride for selenium and a mixture of potassium iodide and ascorbic acid for arsenic and bismuth. Transition metal interference was eliminated with the addition of thiourea and EDTA into the NaBH(4) solution and significant sensitivity enhancement was observed for selenium in the presence of thiourea in the reductant solution. Under optimised conditions, the method achieved detection limits of 0.2 ng mL(-1) for Se, 0.5 ng mL(-1) for As and 0.3 ng mL(-1) for Bi. The method was very reproducible, achieving relative standard deviations of 6.3% for Se, 3.6% for As and 4.7% for Bi, and has a sample throughput of 360 h(-1). Successful application of the method to the quantification of selenium, arsenic and bismuth in a certified reference river sediment sample is reported.


Asunto(s)
Arsénico/análisis , Bismuto/análisis , Selenio/análisis , Espectrofotometría Atómica/métodos , Arsénico/aislamiento & purificación , Ácido Ascórbico/química , Bismuto/aislamiento & purificación , Catálisis , Técnicas de Química Analítica/métodos , Ácido Edético/química , Diseño de Equipo , Metales/química , Oxígeno/química , Yoduro de Potasio/química , Selenio/aislamiento & purificación , Espectrofotometría Atómica/instrumentación , Temperatura , Agua/química
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(8): 1355-7, 2005 Aug.
Artículo en Chino | MEDLINE | ID: mdl-16329521

RESUMEN

A method is reported for the determination of trace bismuth in traditional chinese medicine by hydride generation atomic fluorescence spectrometry. The effect of different means of digestion, the medium amounts of acid and reducing agent on the determination of Bi is investigated. In the given conditions, the linear range of determination is 0.1-200 microg x L(-1), and the detection limit is 0.0946 microg x L(-1). The instrumental relative standard deviation is about 0.55% and the recovery is about 94%-107%. The method is accurate, rapid and convenient with satisfactory results.


Asunto(s)
Bismuto/análisis , Borohidruros/química , Medicina Tradicional China , Espectrometría de Fluorescencia/métodos , Bismuto/química , Bismuto/aislamiento & purificación , Medicamentos Herbarios Chinos/análisis , Medicamentos Herbarios Chinos/química , Medicamentos Herbarios Chinos/normas , Ácido Clorhídrico/química , Peróxido de Hidrógeno/química , Concentración de Iones de Hidrógeno , Ácido Nítrico/química , Reproducibilidad de los Resultados , Ácidos Sulfúricos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA