Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Dis Colon Rectum ; 64(4): 466-474, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33399411

RESUMEN

BACKGROUND: Anal inserts and percutaneous tibial nerve stimulation may be offered to those with fecal incontinence in whom other conservative treatments have failed. OBJECTIVE: We aimed to compare anal inserts and percutaneous tibial nerve stimulation. DESIGN: This was an investigator-blinded randomized pilot study. SETTINGS: The study was conducted at a large tertiary care hospital. PATIENTS: Adult patients with passive or mixed fecal incontinence were recruited. INTERVENTIONS: Patients were randomly assigned to receive either the anal inserts or weekly percutaneous tibial nerve stimulation for a period of 3 months. MAIN OUTCOME MEASURES: The primary end point was a 50% reduction of episodes of fecal incontinence per week as calculated by a prospectively completed 2-week bowel diary. Secondary end points were St Mark's incontinence score, International Consultation on Incontinence Questionnaire-Bowel scores (for bowel pattern, bowel control, and quality of life), use of antidiarrheal agents, estimates of comfort and acceptability. RESULTS: Fifty patients were recruited: 25 were randomly assigned to anal inserts and 25 were randomly assigned to percutaneous tibial nerve stimulation. All completed treatment. A significant improvement of scores in the 2-week bowel diary, the St Mark's scores and the International Consultation on Incontinence Questionnaire-Bowel scores, was seen in both groups after 3 months of treatment. A reduction of ≥50% fecal incontinence episodes was reached by 76% (n = 19/25) by the anal insert group, compared with 48% (n = 12/25) of those in the percutaneous tibial nerve stimulation group (p = 0.04). The St Mark's fecal incontinence scores and the International Consultation on Incontinence Questionnaire-Bowel scores for bowel pattern, bowel control, and quality of life (p = 0.01) suggest similar improvement for each group. LIMITATIONS: A realistic sample size calculation could not be performed because of the paucity of objective prospective studies assessing the effect of the insert device and percutaneous tibial nerve stimulation. CONCLUSIONS: Both anal insert and percutaneous tibial nerve stimulation improved the symptoms of fecal incontinence after 3 months of treatment. The insert device appeared to be more effective than percutaneous tibial nerve stimulation. Larger studies are needed to investigate this further. See Video Abstract at http://links.lww.com/DCR/B460. TRIAL REGISTRATION NUMBER: Clinicaltrials.gov No. NCT04273009. ESTUDIO PILOTO ALEATORIZADO DE INSERCIONES ANALES CONTRA LA ESTIMULACIN PERCUTNEA DEL NERVIO TIBIAL EN PACIENTES CON INCONTINENCIA FECAL: ANTECEDENTES:Las inserciones anales y la estimulación percutánea del nervio tibial (PTNS) se pueden ofrecer a las personas con incontinencia fecal que han fallado en otros tratamientos conservadores.OBJETIVO:Nuestro objetivo fue comparar inserciones anales y estimulación percutánea del nervio tibial.DISEÑO:Este fue un estudio piloto aleatorio ciego para investigadores.AJUSTE:El estudio se realizó en un hospital de atención terciaria.PACIENTES:Se reclutaron pacientes adultos con incontinencia fecal pasiva o mixta.INTERVENCIONES:Los pacientes fueron asignados al azar para recibir inserciones anales o estimulación del nervio tibial percutáneo semanal durante un período de tres meses.PRINCIPALES MEDIDAS DE RESULTADO:El principal resultado fue una reducción del 50% de los episodios de incontinencia fecal por semana, según lo calculado mediante un diario intestinal de dos semanas completado de forma prospectiva. Los criterios de valoración secundarios fueron la puntuación de incontinencia de St Mark, las puntuaciones del ICIQ-B (para patrón intestinal, control intestinal y calidad de vida), uso de agentes antidiarreicos, estimaciones de comodidad y aceptabilidad.RESULTADOS:Se reclutaron 50 pacientes: 25 fueron asignados al azar a inserciones anales y 25 a PTNS. Todo el tratamiento completado. Se observó una mejora significativa de las puntuaciones en el diario intestinal de dos semanas, la puntuación de St Mark y la puntuación del ICIQ-B en ambos grupos después de 3 meses de tratamiento. Se alcanzó una reducción de ≥ 50% de los episodios de incontinencia fecal en un 76% (n = 19/25) en el grupo de inserción anal, en comparación con el 48% (n = 12/25) de los del grupo de estimulación percutánea del nervio tibial (p = 0,04). Las puntuaciones de incontinencia fecal de St Mark, las puntuaciones del ICIQ-B para el patrón intestinal, el control intestinal y la calidad de vida (p = 0,01) sugieren una mejora similar para cada grupo.LIMITACIONES:No se pudo realizar un cálculo realista del tamaño de la muestra debido a la escasez de estudios prospectivos objetivos que evaluaran el efecto del dispositivo de inserción y la estimulación percutánea del nervio tibial.CONCLUSIONES:Tanto la inserción anal como la estimulación percutánea del nervio tibial mejoraron los síntomas de incontinencia fecal después de 3 meses de tratamiento. El dispositivo de inserción parecia ser más efectivo que la estimulación percutánea del nervio tibial. Se necesitan estudios más amplios para investigar esto más a fondo. Consulte Video Resumen en http://links.lww.com/DCR/B460.NÚMERO DE REGISTRO DE PRUEBA:Clinicaltrials.gov No. NCT04273009.


Asunto(s)
Incontinencia Fecal/prevención & control , Implantación de Prótesis/instrumentación , Nervio Tibial/fisiología , Estimulación Eléctrica Transcutánea del Nervio/métodos , Adulto , Anciano , Estudios de Casos y Controles , Incontinencia Fecal/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Prótesis e Implantes/efectos adversos , Prótesis e Implantes/estadística & datos numéricos , Diseño de Prótesis/tendencias , Implantación de Prótesis/métodos , Implantación de Prótesis/estadística & datos numéricos , Calidad de Vida , Siliconas/efectos adversos , Encuestas y Cuestionarios , Estimulación Eléctrica Transcutánea del Nervio/estadística & datos numéricos , Resultado del Tratamiento
2.
Interv Cardiol Clin ; 8(3): 295-300, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31078185

RESUMEN

Mitral regurgitation is the most commonly occurring valvular heart disease in developed countries. Transcatheter mitral valve replacement (TMVR) has emerged as a novel potential therapy for patients with severe mitral valve disease who are unsuitable candidates for conventional surgery or transcatheter edge-to-edge mitral repair. TMVR with the Tendyne prosthesis has shown potential at short-term follow-up to be an effective and safe treatment alternative for high-risk patients with severe mitral valve disease.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Aleaciones , Cateterismo Cardíaco/métodos , Ensayos Clínicos como Asunto , Ecocardiografía Transesofágica/métodos , Estudios de Factibilidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/anatomía & histología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/patología , Imagen Multimodal/métodos , Ensayos Clínicos Controlados no Aleatorios como Asunto , Estudios Prospectivos , Diseño de Prótesis/tendencias , Calidad de Vida , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología
3.
Klin Monbl Augenheilkd ; 233(11): 1238-1243, 2016 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-27643604

RESUMEN

Implantable retinal prostheses for the blind are already in use. In blind subjects suffering from retinitis pigmentosa (RP), these systems are able to induce phosphenes. However, the measurable gain in vision is limited. This is due to degeneration in the retina itself and to the technology, which is used in the currently available systems. Research groups and companies are working on solutions and prototypes to improve the outcome of electrical stimulation in the visual system. One improvement will be to enlarge the electrode array in order to restore a larger visual field. A second approach is to enlarge the number of electrodes and to place them at a higher density to improve the spatial resolution of the system. A third concept is to develop a recording unit within the electrode array to analyse ganglion cell behaviour underneath the electrode. This information can than be used to optimise the stimulation pattern. Not only retinal prostheses are under development but also systems to stimulate the retina from the suprachoroidal space, to directly stimulate the optic nerve or the lateral geniculate body or even the primary visual cortex.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/tendencias , Predicción , Diseño de Prótesis/tendencias , Degeneración Retiniana/rehabilitación , Prótesis Visuales/tendencias , Animales , Electrodos Implantados/tendencias , Medicina Basada en la Evidencia , Humanos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Implantación de Prótesis/tendencias , Degeneración Retiniana/complicaciones , Evaluación de la Tecnología Biomédica , Resultado del Tratamiento
4.
BMC Musculoskelet Disord ; 16: 249, 2015 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-26363981

RESUMEN

BACKGROUND: The optimal type of bearing for hip arthroplasty remains a matter of debate. Ceramic-on-polyethylene (CoP) bearings are frequently used in younger and more active patients to reduce wear and increase biocompatibility compared to Metal-on-Polyethylene (MoP) bearings. However, in comparison to metal heads, the fracture risk of ceramic heads is higher. In addition, ceramic head fractures pose a serious complication which often necessitates major revision surgery. To date, there are no long-term data (>20 years of follow-up) reporting fracture rates of the ceramic femoral heads in CoP bearings. The purpose of this research was to investigate long-term CoP fracture rate. METHODS: We evaluated the clinical and radiographic results of 348 cementless THAs treated with 2nd generation Biolox Al2O3 Ceramic-on-Polyethylene (CoP) bearings consecutively implanted between January 1985 and December 1989. The mean age at implantation was 57 years. The patients were followed for a minimum of 20 years. At the final 111 had died, and 5 were lost to follow-up. The cumulative incidence of ceramic head fractures in the long-term was estimated using a competing risk analysis. RESULTS: The cumulative incidence of ceramic head fracture after 22-years was estimated with a competing risk analysis at 0.29% after 22-years (SE = 2.09%; 95% - CI: 0.03-1.5%). The radiographic analysis revealed no impending failures at final follow-up. DISCUSSION/CONCLUSION: The fracture rate of second-generation ceramic heads using a CoP articulation remains very low into the third decade after cementless THA.


Asunto(s)
Óxido de Aluminio/administración & dosificación , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/tendencias , Prótesis de Cadera/tendencias , Diseño de Prótesis/tendencias , Falla de Prótesis/tendencias , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Prótesis de Cadera/normas , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis/normas , Factores de Tiempo , Adulto Joven
5.
J Mech Behav Biomed Mater ; 31: 107-16, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23746930

RESUMEN

The objective of this article is to provide an up-to-date overview of zirconia-toughened alumina (ZTA) components used in total hip arthroplasties. The structure, mechanical properties, and available data regarding the clinical performance of ZTA are summarized. The advancements that have been made in understanding the in vivo performance of ZTA are investigated. This article concludes with a discussion of gaps in the literature related to ceramic biomaterials and avenues for future research.


Asunto(s)
Óxido de Aluminio/síntesis química , Materiales Biocompatibles/síntesis química , Cerámica/síntesis química , Prótesis de Cadera/tendencias , Circonio/química , Módulo de Elasticidad , Predicción , Dureza , Diseño de Prótesis/tendencias
6.
J Indian Med Assoc ; 110(3): 175-8, 180, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23029949

RESUMEN

Voice rehabilitation after a total laryngectomy is an important requisite for patients' rehabilitation. Oesophageal speech using tracheo-oesophageal-valved prostheses is now considered the state-of-art in postlaryngectomy voice rehabilitation. One of the major drawbacks of voice prostheses is their limited device lifetime. This is due to the deterioration of the silicone rubber material by different bacterial and yeast species, which are organised in the form of a biofilm resulting in internal leakage, increased airflow resistance, impeding speech, respiration and swallowing. The use of antimicrobials though easily applicable is associated with development of resistance if used on long-term basis. Other techniques in the form of modification of physicochemical properties of the silicon surface or covalent binding of antimicrobial agents to the silicon surface have been employed. This article reviews the different strategies investigated until now and the future trends in preventing biofilm formation for prolonging the lifetime of the silicon voice prostheses. Data was collected by conducting a computer aided search of the MED-LINE and PUBMED databases, supplemented by hand searches of key journals. Over 35 articles in the last two decades on the topic have been reviewed out of which 27 were found to be of relevant value for this article.


Asunto(s)
Biopelículas/efectos de los fármacos , Candida , Laringe Artificial/efectos adversos , Complicaciones Posoperatorias/prevención & control , Elastómeros de Silicona , Streptococcus , Antiinfecciosos/uso terapéutico , Materiales Biocompatibles/uso terapéutico , Candida/crecimiento & desarrollo , Candida/aislamiento & purificación , Análisis de Falla de Equipo , Humanos , Laringectomía/efectos adversos , Laringectomía/rehabilitación , Diseño de Prótesis/métodos , Diseño de Prótesis/tendencias , Falla de Prótesis/efectos de los fármacos , Implantación de Prótesis/rehabilitación , Infecciones Relacionadas con Prótesis/microbiología , Voz Alaríngea/instrumentación , Voz Alaríngea/métodos , Streptococcus/crecimiento & desarrollo , Streptococcus/aislamiento & purificación , Tensoactivos/uso terapéutico
10.
Annu Rev Biomed Eng ; 5: 207-49, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12704085

RESUMEN

The history of cochlear implants is marked by large improvements in performance, especially over the past two decades and especially due to the development of ever-better processing strategies. Although the progress to date has been substantial, present devices still do not restore normal speech reception, even for top performers and particularly for listening to speech in competition with noise or other talkers. In addition, a wide range of outcomes persists, with some patients receiving little benefit using the same devices that support high levels of speech reception for others. The purpose of this review is to describe some likely possibilities for further improvement, including (a) combined electric and acoustic stimulation of the auditory system for patients with significant residual hearing, (b) use of bilateral implants, (c) a closer replication with implants of the processing steps in the normal cochlea, and (d) applications of knowledge about factors that are correlated with outcomes to help patients presently at the low end of the performance scale.


Asunto(s)
Estimulación Acústica/métodos , Biomimética/métodos , Implantes Cocleares/clasificación , Implantes Cocleares/tendencias , Terapia por Estimulación Eléctrica/métodos , Pérdida Auditiva/rehabilitación , Procesamiento de Señales Asistido por Computador , Estimulación Acústica/instrumentación , Biomimética/instrumentación , Terapia por Estimulación Eléctrica/instrumentación , Análisis de Falla de Equipo , Humanos , Diseño de Prótesis/métodos , Diseño de Prótesis/tendencias , Inteligibilidad del Habla , Percepción del Habla , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA