1.
JMIR Ment Health ; 11: e55552, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38663011

RESUMEN

BACKGROUND: Heart rate variability (HRV) biofeedback is often performed with structured education, laboratory-based assessments, and practice sessions. It has been shown to improve psychological and physiological function across populations. However, a means to remotely use and monitor this approach would allow for wider use of this technique. Advancements in wearable and digital technology present an opportunity for the widespread application of this approach. OBJECTIVE: The primary aim of the study was to determine the feasibility of fully remote, self-administered short sessions of HRV-directed biofeedback in a diverse population of health care workers (HCWs). The secondary aim was to determine whether a fully remote, HRV-directed biofeedback intervention significantly alters longitudinal HRV over the intervention period, as monitored by wearable devices. The tertiary aim was to estimate the impact of this intervention on metrics of psychological well-being. METHODS: To determine whether remotely implemented short sessions of HRV biofeedback can improve autonomic metrics and psychological well-being, we enrolled HCWs across 7 hospitals in New York City in the United States. They downloaded our study app, watched brief educational videos about HRV biofeedback, and used a well-studied HRV biofeedback program remotely through their smartphone. HRV biofeedback sessions were used for 5 minutes per day for 5 weeks. HCWs were then followed for 12 weeks after the intervention period. Psychological measures were obtained over the study period, and they wore an Apple Watch for at least 7 weeks to monitor the circadian features of HRV. RESULTS: In total, 127 HCWs were enrolled in the study. Overall, only 21 (16.5%) were at least 50% compliant with the HRV biofeedback intervention, representing a small portion of the total sample. This demonstrates that this study design does not feasibly result in adequate rates of compliance with the intervention. Numerical improvement in psychological metrics was observed over the 17-week study period, although it did not reach statistical significance (all P>.05). Using a mixed effect cosinor model, the mean midline-estimating statistic of rhythm (MESOR) of the circadian pattern of the SD of the interbeat interval of normal sinus beats (SDNN), an HRV metric, was observed to increase over the first 4 weeks of the biofeedback intervention in HCWs who were at least 50% compliant. CONCLUSIONS: In conclusion, we found that using brief remote HRV biofeedback sessions and monitoring its physiological effect using wearable devices, in the manner that the study was conducted, was not feasible. This is considering the low compliance rates with the study intervention. We found that remote short sessions of HRV biofeedback demonstrate potential promise in improving autonomic nervous function and warrant further study. Wearable devices can monitor the physiological effects of psychological interventions.


Asunto(s)
Biorretroalimentación Psicológica , Frecuencia Cardíaca , Dispositivos Electrónicos Vestibles , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Biorretroalimentación Psicológica/métodos , Biorretroalimentación Psicológica/instrumentación , Personal de Salud , Frecuencia Cardíaca/fisiología , Ciudad de Nueva York , Estudios Prospectivos , Telemedicina/métodos , Telemedicina/instrumentación
2.
Artículo en Inglés | MEDLINE | ID: mdl-38512736

RESUMEN

Sensorimotor impairment is a prevalent condition requiring effective rehabilitation strategies. This study introduces a novel wearable device for Mindful Sensorimotor Training (MiSMT) designed for sensory and motor rehabilitation. Our MiSMT device combines motor training using myoelectric pattern recognition along sensory training using two tactile displays. This device offers a comprehensive solution, integrating electromyography and haptic feedback, lacking in existing devices. The device features eight electromyography channels, a rechargeable battery, and wireless Bluetooth or Wi-Fi connectivity for seamless communication with a computer or mobile device. Its flexible material allows for adaptability to various body parts, ensuring ease of use in diverse patients. The two tactile displays, with 16 electromagnetic actuators each, provide touch and vibration sensations up to 250 Hz. In this proof-of-concept study, we show improved two-point discrimination after 5 training sessions in participants with intact limbs (p=0.047). We also demonstrated successful acquisition, processing, and decoding of myoelectric signals in offline and online evaluations. In conclusion, the MiSMT device presents a promising tool for sensorimotor rehabilitation by combining motor execution and sensory training benefits. Further studies are required to assess its effectiveness in individuals with sensorimotor impairments. Integrating mindful sensory and motor training with innovative technology can enhance rehabilitation outcomes and improve the quality of life for those with sensorimotor impairments.


Asunto(s)
Rehabilitación Neurológica , Percepción del Tacto , Dispositivos Electrónicos Vestibles , Humanos , Calidad de Vida , Tacto/fisiología , Percepción del Tacto/fisiología
3.
IEEE J Biomed Health Inform ; 28(5): 2569-2580, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38498747

RESUMEN

Acupoints (APs) prove to have positive effects on disease diagnosis and treatment, while intelligent techniques for the automatic detection of APs are not yet mature, making them more dependent on manual positioning. In this paper, we realize the skin conductance-based APs and non-APs recognition with machine learning, which could assist in APs detection and localization in clinical practice. Firstly, we collect skin conductance of traditional Five-Shu Point and their corresponding non-APs with wearable sensors, establishing a dataset containing over 36000 samples of 12 different AP types. Then, electrical features are extracted from the time domain, frequency domain, and nonlinear perspective respectively, following which typical machine learning algorithms (SVM, RF, KNN, NB, and XGBoost) are demonstrated to recognize APs and non-APs. The results demonstrate XGBoost with the best precision of 66.38%. Moreover, we also quantify the impacts of the differences among AP types and individuals, and propose a pairwise feature generation method to weaken the impacts on recognition precision. By using generated pairwise features, the recognition precision could be improved by 7.17%. The research systematically realizes the automatic recognition of APs and non-APs, and is conducive to pushing forward the intelligent development of APs and Traditional Chinese Medicine theories.


Asunto(s)
Puntos de Acupuntura , Respuesta Galvánica de la Piel , Aprendizaje Automático , Procesamiento de Señales Asistido por Computador , Humanos , Respuesta Galvánica de la Piel/fisiología , Algoritmos , Masculino , Dispositivos Electrónicos Vestibles , Femenino , Adulto , Adulto Joven
4.
Sensors (Basel) ; 24(5)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38475086

RESUMEN

We have previously reported wearable loop sensors that can accurately monitor knee flexion with unique merits over the state of the art. However, validation to date has been limited to single-leg configurations, discrete flexion angles, and in vitro (phantom-based) experiments. In this work, we take a major step forward to explore the bilateral monitoring of knee flexion angles, in a continuous manner, in vivo. The manuscript provides the theoretical framework of bilateral sensor operation and reports a detailed error analysis that has not been previously reported for wearable loop sensors. This includes the flatness of calibration curves that limits resolution at small angles (such as during walking) as well as the presence of motional electromotive force (EMF) noise at high angular velocities (such as during running). A novel fabrication method for flexible and mechanically robust loops is also introduced. Electromagnetic simulations and phantom-based experimental studies optimize the setup and evaluate feasibility. Proof-of-concept in vivo validation is then conducted for a human subject performing three activities (walking, brisk walking, and running), each lasting 30 s and repeated three times. The results demonstrate a promising root mean square error (RMSE) of less than 3° in most cases.


Asunto(s)
Caminata , Dispositivos Electrónicos Vestibles , Humanos , Fenómenos Biomecánicos , Movimiento (Física) , Rango del Movimiento Articular , Articulación de la Rodilla
5.
J Korean Med Sci ; 39(9): e94, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38469966

RESUMEN

BACKGROUND: To evaluate the therapeutic effectiveness and safety of a neurofeedback wearable device for stress reduction. METHODS: A randomized, double-blind, controlled study was designed. Participants had psychological stress with depression or sleep disturbances. They practiced either neurofeedback-assisted meditation (n = 20; female, 15 [75.0%]; age, 49.40 ± 11.76 years) or neurofeedback non-assisted meditation (n = 18; female, 11 [61.1%]; age, 48.67 ± 12.90 years) for 12 minutes twice a day for two weeks. Outcome variables were self-reported questionnaires, including the Korean version of the Perceived Stress Scale, Beck Depression Inventory-II, Insomnia Severity Index, Pittsburgh Sleep Quality Index, and State Trait Anxiety Index, quantitative electroencephalography (qEEG), and blood tests. Satisfaction with device use was measured at the final visit. RESULTS: The experimental group had a significant change in PSS score after two weeks of intervention compared with the control group (6.45 ± 0.95 vs. 3.00 ± 5.54, P = 0.037). State anxiety tended to have a greater effect in the experimental group than in the control group (P = 0.078). Depressive mood and sleep also improved in each group, with no significant difference between the two groups. There were no significant differences in stress-related physiological parameters, such as stress hormones or qEEG, between the two groups. Subjective device satisfaction was significantly higher in the experimental group than in the control group (P = 0.008). CONCLUSION: Neurofeedback-assisted meditation using a wearable device can help improve subjective stress reduction compared with non-assisted meditation. These results support neurofeedback as an effective adjunct to meditation for relieving stress. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0007413.


Asunto(s)
Meditación , Neurorretroalimentación , Pruebas Psicológicas , Autoinforme , Dispositivos Electrónicos Vestibles , Adulto , Femenino , Humanos , Persona de Mediana Edad , Método Doble Ciego , Meditación/métodos , Meditación/psicología , Estrés Psicológico/terapia , Estrés Psicológico/psicología , Masculino
6.
Mater Horiz ; 11(8): 2010-2020, 2024 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-38362790

RESUMEN

Flexible and stretchable heaters are increasingly recognized for their great potential in wearable thermotherapy to treat muscle spasms, joint injuries and arthritis. However, issues like lengthy processing, high fabrication cost, and toxic chemical involvement are obstacles on the way to popularize stretchable heaters for medical use. Herein, using a single-step customizable laser fabrication method, we put forward the design of cost-effective wearable laser-induced graphene (LIG) heaters with kirigami patterns, which offer multimodal stretchability and conformal fit to the skin around the human body. First, we develop the manufacturing process of the LIG heaters with three different kirigami patterns enabling reliable stretchability by out-of-plane buckling. Then, by adjusting the laser parameters, we confirm that the LIG produced by medium laser power could maintain a balance between mechanical strength and electrical conductivity. By optimizing cutting-spacing ratios through experimental measurements of stress, resistance and temperature profiles, as well as finite element analysis (FEA), we determine that a larger cutting-spacing ratio within the machining precision will lead to better mechanical, electrical and heating performance. The optimized stretchable heater in this paper could bear significant unidirectional strain over 100% or multidirectional strain over 20% without major loss in conductivity and heating performance. On-body tests and fatigue tests also proved great robustness in practical scenarios. With the advantage of safe usage, simple and customizable fabrication, easy bonding with skin, and multidirectional stretchability, the on-skin heaters are promising to substitute the traditional heating packs/wraps for thermotherapy.


Asunto(s)
Grafito , Hipertermia Inducida , Rayos Láser , Dispositivos Electrónicos Vestibles , Humanos , Hipertermia Inducida/métodos , Hipertermia Inducida/instrumentación , Diseño de Equipo , Análisis de Elementos Finitos , Conductividad Eléctrica
7.
Artículo en Inglés | MEDLINE | ID: mdl-38224523

RESUMEN

Wearable lower-limb joint angle estimation using a reduced inertial measurement unit (IMU) sensor set could enable quick, economical sports injury risk assessment and motion capture; however the vast majority of existing research requires a full IMU set attached to every related body segment and is implemented in only a single movement, typically walking. We thus implemented 3-dimensional knee and hip angle estimation with a reduced IMU sensor set during yoga, golf, swimming (simulated lower body swimming in a seated posture), badminton, and dance movements. Additionally, current deep-learning models undergo an accuracy drop when tested with new and unseen activities, which necessitates collecting large amounts of data for the new activity. However, collecting large datasets for every new activity is time-consuming and expensive. Thus, a transfer learning (TL) approach with long short-term memory neural networks was proposed to enhance the model's generalization ability towards new activities while minimizing the need for a large new-activity dataset. This approach could transfer the generic knowledge acquired from training the model in the source-activity domain to the target-activity domain. The maximum improvement in estimation accuracy (RMSE) achieved by TL is 23.6 degrees for knee flexion/extension and 22.2 degrees for hip flexion/extension compared to without TL. These results extend the application of motion capture with reduced sensor configurations to a broader range of activities relevant to injury prevention and sports training. Moreover, they enhance the capacity of data-driven models in scenarios where acquiring a substantial amount of training data is challenging.


Asunto(s)
Baile , Golf , Deportes de Raqueta , Dispositivos Electrónicos Vestibles , Yoga , Humanos , Natación , Articulación de la Rodilla , Aprendizaje Automático , Fenómenos Biomecánicos
8.
Sensors (Basel) ; 24(2)2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38257494

RESUMEN

Temporal gait asymmetry (TGA) is commonly observed in individuals facing mobility challenges. Rhythmic auditory stimulation (RAS) can improve temporal gait parameters by promoting synchronization with external cues. While biofeedback for gait training, providing real-time feedback based on specific gait parameters measured, has been proven to successfully elicit changes in gait patterns, RAS-based biofeedback as a treatment for TGA has not been explored. In this study, a wearable RAS-based biofeedback gait training system was developed to measure temporal gait symmetry in real time and deliver RAS accordingly. Three different RAS-based biofeedback strategies were compared: open- and closed-loop RAS at constant and variable target levels. The main objective was to assess the ability of the system to induce TGA with able-bodied (AB) participants and evaluate and compare each strategy. With all three strategies, temporal symmetry was significantly altered compared to the baseline, with the closed-loop strategy yielding the most significant changes when comparing at different target levels. Speed and cadence remained largely unchanged during RAS-based biofeedback gait training. Setting the metronome to a target beyond the intended target may potentially bring the individual closer to their symmetry target. These findings hold promise for developing personalized and effective gait training interventions to address TGA in patient populations with mobility limitations using RAS.


Asunto(s)
Biorretroalimentación Psicológica , Dispositivos Electrónicos Vestibles , Humanos , Estimulación Acústica , Señales (Psicología) , Marcha
9.
Nat Commun ; 15(1): 762, 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-38278810

RESUMEN

A wearable biological patch capable of producing multiple responses to light and electricity without interfering with daily activities is highly desired for skin cancer treatment, but remains a key challenge. Herein, the skin-mountable electrostimulation-augmented photothermal patch (eT-patch) comprising transparent ionic gel with MXene (Ti3C2Tx) doping is developed and applied for the treatment of melanoma under photostimulation at 0.5 W/cm2. The eT-patch designed has superior photothermal and electrical characteristics owing to ionic gels doped with MXene which provides high photothermal conversion efficiency and electrical conductivity as a medium. Simultaneously, the ionic gel-based eT-patch having excellent optical transparency actualizes real-time observation of skin response and melanoma treatment process under photothermal and electrical stimulation (PES) co-therapy. Systematical cellular study on anti-tumor mechanism of the eT-patch under PES treatment revealed that eT-patch under PES treatment can synergically trigger cancer cell apoptosis and pyroptosis, which together lead to the death of melanoma cells. Due to the obvious advantages of relatively safe and less side effects in healthy organs, the developed eT-patch provides a promising cost-effective therapeutic strategy for skin tumors and will open a new avenue for biomedical applications of ionic gels.


Asunto(s)
Terapia por Estimulación Eléctrica , Melanoma , Nitritos , Neoplasias Cutáneas , Elementos de Transición , Dispositivos Electrónicos Vestibles , Humanos , Melanoma/terapia , Neoplasias Cutáneas/terapia , Geles , Iones
10.
Urology ; 183: 63-69, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37944596

RESUMEN

OBJECTIVE: To evaluate the effectiveness and safety of a novel wearable neuromodulation system incorporating embedded electromyographic evaluation, representing the first closed-loop wearable therapy for bladder control. METHODS: This 12-week, multicenter, open-label, single-arm study of subjects with overactive bladder assessed response of bladder diary parameters and quality of life (QOL) metrics. Subjects used the transcutaneous tibial neuromodulation system, either once or three times weekly, with evaluations at weeks 1, 4, 8, and 12. Enrolled subjects (N = 96) were assessed for changes in urinary frequency, urgency, and urgency urinary incontinence episodes, and QOL changes using various questionnaires. RESULTS: In the intent-to-treat population (N = 96, mean age 60.8 ± 13.0years, 88.5% female), significant reductions in 3-day diary parameters were observed for daily voids, incontinence, and urgency episodes at 12weeks. QOL improvements exceeded the minimal clinically important difference for all QOL questionnaires. Long-term results remained robust at 12months. Device-related adverse events were mild and there were no device-related serious adverse events. Mean therapy compliance at 12weeks was 88.5%. High satisfaction rates were reported for the device overall. CONCLUSION: The Avation device demonstrates promising efficacy in treating adults with overactive bladder and urge urinary incontinence. At 12weeks, both diary parameters and QOL indicators showed significant improvement and remained robust at 12months. The device had a favorable safety profile with high compliance and patient satisfaction. This novel, closed-loop wearable tibial neuromodulation system represents a significant advancement in bladder control therapy, offering a noninvasive, patient-centered alternative with improved accessibility and ease of use.


Asunto(s)
Terapia por Estimulación Eléctrica , Vejiga Urinaria Hiperactiva , Dispositivos Electrónicos Vestibles , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Vejiga Urinaria Hiperactiva/terapia , Calidad de Vida , Incontinencia Urinaria de Urgencia/terapia , Terapia por Estimulación Eléctrica/métodos , Resultado del Tratamiento
11.
Artículo en Inglés | MEDLINE | ID: mdl-37356818

RESUMEN

Growing interest over recent years in personalized health monitoring coupled with the skyrocketing popularity of wearable smart devices has led to the increased relevance of wearable sweat-based sensors for biomarker detection. From optimizing workouts to risk management of cardiovascular diseases and monitoring prediabetes, the ability of sweat sensors to continuously and noninvasively measure biomarkers in real-time has a wide range of applications. Conventional sweat sensors utilize external stimulation of sweat glands to obtain samples, however; this stimulation influences the expression profile of the biomarkers and reduces the accuracy of the detection method. To address this limitation, our laboratory pioneered the development of the passive sweat sensor subfield, which allowed for our progress in developing a sweat chemistry panel. Passive sweat sensors utilize nanoporous structures to confine and detect biomarkers in ultra-low sweat volumes. The ability of passive sweat sensors to use smaller samples than conventional sensors enable users with sedentary lifestyles who perspire less to benefit from sweat sensor technology not previously afforded to them. Herein, the mechanisms and strategies of current sweat sensors are summarized with an emphasis on the emerging subfield of passive sweat-based diagnostics. Prospects for this technology include discovering new biomarkers expressed in sweat and expanding the list of relevant detectable biomarkers. Moreover, the accuracy of biomarker detection can be enhanced with machine learning using prediction algorithms trained on clinical data. Applying this machine learning in conjunction with multiplex biomarker detection will allow for a more holistic approach to trend predictions. This article is categorized under: Diagnostic Tools > Diagnostic Nanodevices Nanotechnology Approaches to Biology > Nanoscale Systems in Biology Diagnostic Tools > Biosensing.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Sudor/química , Sudor/metabolismo , Biomarcadores/análisis
12.
Adv Sci (Weinh) ; 11(4): e2305312, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38037312

RESUMEN

The motion detection and thermotherapy provides a convenient strategy for the diagnosis and rehabilitation assessment of joint injuries. However, it is still challenging to simultaneously achieve accurate joint motion monitoring and on-demand thermotherapy. Herein, core-sheath sensing yarns (CSSYs) is proposed and fabricated for excellent electrical and photothermal heating, which consists of carbon black (CB)-coated nylon (sheath layer), silver-plated nylon and elastic spandex yarns (core layer). The CSSYs demonstrates great joule heating performance, which reaches 75 °C at 2 V applied voltage. The good thermal management performance can be well maintained when weaving these yarns into bifunctional smart textile. Further, the optimized double-ply CSSYs (DPCSSYs) with helically twisted structure possess several appealing sensing performance, including preferable strain sensitivity (0.854), excellent linearity (0.962), and superior durability (over 5000 cycles). The as-woven bifunctional smart textile can provide instant and convenient thermotherapy to the injured joints, and simultaneously monitor the injury and recovery conditions of the joint. Therefore, the designed bifunctional smart textile can provide a promising route for developing next-generation healthcare smart textile.


Asunto(s)
Nylons , Dispositivos Electrónicos Vestibles , Humanos , Textiles , Movimiento (Física) , Poliuretanos/química
13.
Altern Ther Health Med ; 30(1): 78-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37820671

RESUMEN

Objective: Lung cancer patients mostly had different degrees of impaired pulmonary function, and these damage also significantly affect quality of life. The concept of pulmonary rehabilitation applicable to patients with chronic respiratory diseases is also applicable to patients with lung cancer. The current application of pulmonary rehabilitation for lung cancer is inconsistent, and reliable guidelines are lacking. The purpose of this study was to investigate the effect of pulmonary rehabilitation exercise based on wearable device pedometer on lung cancer patients with impaired pulmonary function, and to find a suitable pulmonary rehabilitation program for patients with lung cancer. Methods: In this retrospective study, 100 lung cancer patients with impaired pulmonary function were included. Among them, 51 patients received pulmonary rehabilitation exercise based on a wearable device pedometer (Experiemental group), while 49 received routine nursing mode (Control group). The respiratory function, quality of life, and sports endurance of the two groups were observed. Results: The incidence of postoperative atelectasis, pulmonary infection, hypoxemia, postoperative oxygen therapy time, chest tube indwelling time, and postoperative hospital stay in the experimental group were significantly lower than those in the control group (P < .05); The FEV1, FVC and FVE1% of the experimental group were significantly higher than those of the control group after intervention (all P < .05). Conclusion: Pulmonary rehabilitation exercise based on a wearable device pedometer can effectively improve the respiratory function and exercise endurance of lung cancer patients with impaired pulmonary function and can improve the quality of life and reduce the length of hospital stay.


Asunto(s)
Neoplasias Pulmonares , Enfermedad Pulmonar Obstructiva Crónica , Dispositivos Electrónicos Vestibles , Humanos , Neoplasias Pulmonares/complicaciones , Calidad de Vida , Actigrafía , Estudios Retrospectivos , Terapia por Ejercicio
14.
Artículo en Inglés | MEDLINE | ID: mdl-38083349

RESUMEN

The objectives of this study were to test the feasibility of the developed waterproof wearable device with a Surface Electromyography (sEMG) sensor and Inertial Measurement Unit (IMU) sensor by (1) comparing the onset duration of sEMG recordings from maximal voluntary contractions (MVC), (2) comparing the acceleration of arm movement from IMU, and (3) observing the reproducibility of onset duration and acceleration from the developed device for bicep brachii (BB) muscle between on dry-land, and in aquatic environments. Five healthy males participated in two experimental protocols with the activity of BB muscle of the left and right arms. Using the sEMG of BB muscle, the intra-class correlation coefficient (ICC) and typical error (CV%) were calculated to determine the reproducibility and precision of onset duration and acceleration, respectively. In case of onset duration, no significant differences were observed between land and aquatic condition (p = 0.9-0.98), and high reliability (ICC = 0.93-0.98) and precision (CV% = 2.7-6.4%) were observed. In addition, acceleration data shows no significant differences between land and aquatic condition (p = 0.89-0.93), and high reliability (ICC = 0.9-0.97) and precision (CV% = 7.9-9.2%). These comparable sEMG and acceleration values in both dry-land and aquatic environment supports the suitability of the proposed wearable device for musculoskeletal monitoring during aquatic therapy and rehabilitation as the integrity of the sEMG and acceleration recordings maintained during aquatic activities.Clinical Relevance-This study and relevant experiment demonstrate the feasibility of the developed wearable device to support clinicians and therapists for musculoskeletal monitoring during aquatic therapy and rehabilitation.


Asunto(s)
Contracción Isométrica , Dispositivos Electrónicos Vestibles , Masculino , Humanos , Reproducibilidad de los Resultados , Contracción Isométrica/fisiología , Terapia Acuática , Estudios de Factibilidad
15.
Artículo en Inglés | MEDLINE | ID: mdl-38083600

RESUMEN

Physical therapy is strongly recommended for patients with neurological disorders. Tai Chi-based treatments seem to improve physical functions like gait speed and balance. However, assessments after treatment rely on semi-quantitative clinical scales affected by subjectivity with controversial results. This study aims at investigating whether Tai Chi could be a valid alternative to traditional physiotherapy rehabilitation. We propose a wearable system composed of two inertial devices able to objectively measure the effect of the rehabilitation treatment on the range of movement of the trunk. Seventeen patients with Parkinson's Disease (PD) were recruited and assessed. They have been randomly divided into two groups: group 1 followed a Tai Chi-based treatment, while group 2 underwent a traditional physiotherapy rehabilitation. The two groups have been assessed before (t0) and after the treatment (t1). No statistical differences have been found in the relative range of motion between the upper and lower sensors between the two groups at the baseline. Both treatments resulted in a significant improvement in the trunk range of movement (on the right side). Notably, the improvement in the effect size of the treatment was greater in group 1 than in group 2. In fact, even if both the groups benefited from their treatment group 1 gained larger mobility of the trunk if compared to group 2. Interestingly, no differences have been accounted adopting the traditional UPDRS III for motor symptoms of PD, strengthening the idea that objective measurement coming from wearable biomedical sensors could detect information otherwise neglected by traditional clinical tools.Clinical Relevance- This study preliminary confirms that beneficial motor effects after a Tai Chi rehabilitation program are comparable and quite better than after traditional physiotherapy, promoting Tai Chi as a valid alternative treatment for PD patients.


Asunto(s)
Enfermedad de Parkinson , Taichi Chuan , Dispositivos Electrónicos Vestibles , Humanos , Terapia por Ejercicio , Movimiento , Enfermedad de Parkinson/terapia , Taichi Chuan/métodos
16.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(6): 1093-1101, 2023 Dec 25.
Artículo en Chino | MEDLINE | ID: mdl-38151931

RESUMEN

Rapid and accurate identification and effective non-drug intervention are the worldwide challenges in the field of depression. Electroencephalogram (EEG) signals contain rich quantitative markers of depression, but whole-brain EEG signals acquisition process is too complicated to be applied on a large-scale population. Based on the wearable frontal lobe EEG monitoring device developed by the authors' laboratory, this study discussed the application of wearable EEG signal in depression recognition and intervention. The technical principle of wearable EEG signals monitoring device and the commonly used wearable EEG devices were introduced. Key technologies for wearable EEG signals-based depression recognition and the existing technical limitations were reviewed and discussed. Finally, a closed-loop brain-computer music interface system for personalized depression intervention was proposed, and the technical challenges were further discussed. This review paper may contribute to the transformation of relevant theories and technologies from basic research to application, and further advance the process of depression screening and personalized intervention.


Asunto(s)
Musicoterapia , Música , Dispositivos Electrónicos Vestibles , Humanos , Algoritmos , Depresión/diagnóstico , Depresión/terapia , Electroencefalografía
17.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37941278

RESUMEN

Foot drop is a gait disturbance characterized by difficulty in performing ankle dorsiflexion during the swing phase of the gait cycle. Current available evidence shows that functional electrical stimulation (FES) on the musculature responsible for dorsal ankle flexion during gait can have positive effects on walking ability. This study aims to present a proof of concept for a novel easy-to-use FES system and evaluates the biomechanical effects during gait in stroke patients, compared to unassisted walking. Gait was quantitatively evaluated in a movement analysis laboratory for five subjects with chronic stroke, in basal condition without assistance and in gait assisted with FES. Improvements were found in all temporospatial parameters during FES-assisted gait, evidenced by statistically significant differences only in gait speed (p=0.02). Joint kinematics showed positive changes in hip abduction and ankle dorsiflexion variables during the swing phase of the gait cycle. No significant differences were found in the Gait Deviation Index. In conclusion, the present pilot study demonstrates that the use of this FES system in the tibialis anterior muscle can cause gait functional improvements in subjects with foot drop due to chronic stroke.


Asunto(s)
Terapia por Estimulación Eléctrica , Trastornos Neurológicos de la Marcha , Neuropatías Peroneas , Accidente Cerebrovascular , Dispositivos Electrónicos Vestibles , Humanos , Proyectos Piloto , Neuropatías Peroneas/complicaciones , Marcha/fisiología , Caminata/fisiología , Fenómenos Biomecánicos , Trastornos Neurológicos de la Marcha/etiología
18.
Neurodegener Dis ; 23(1-2): 13-19, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37913759

RESUMEN

BACKGROUND: Technological evolution leads to the constant enhancement of monitoring systems and recording symptoms of diverse disorders. SUMMARY: For Parkinson's disease, wearable devices empowered with machine learning analysis are the main modules for objective measurements. Software and hardware improvements have led to the development of reliable systems that can detect symptoms accurately and be implicated in the follow-up and treatment decisions. KEY MESSAGES: Among many different devices developed so far, the most promising ones are those that can record symptoms from all extremities and the trunk, in the home environment during the activities of daily living, assess gait impairment accurately, and be suitable for a long-term follow-up of the patients. Such wearable systems pave the way for a paradigm shift in the management of patients with Parkinson's disease.


Asunto(s)
Enfermedad de Parkinson , Dispositivos Electrónicos Vestibles , Humanos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/diagnóstico , Actividades Cotidianas
19.
Sci Rep ; 13(1): 17515, 2023 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-37845236

RESUMEN

Difficulty falling asleep is one of the typical insomnia symptoms. However, intervention therapies available nowadays, ranging from pharmaceutical to hi-tech tailored solutions, remain ineffective due to their lack of precise real-time sleep tracking, in-time feedback on the therapies, and an ability to keep people asleep during the night. This paper aims to enhance the efficacy of such an intervention by proposing a novel sleep aid system that can sense multiple physiological signals continuously and simultaneously control auditory stimulation to evoke appropriate brain responses for fast sleep promotion. The system, a lightweight, comfortable, and user-friendly headband, employs a comprehensive set of algorithms and dedicated own-designed audio stimuli. Compared to the gold-standard device in 883 sleep studies on 377 subjects, the proposed system achieves (1) a strong correlation (0.89 ± 0.03) between the physiological signals acquired by ours and those from the gold-standard PSG, (2) an 87.8% agreement on automatic sleep scoring with the consensus scored by sleep technicians, and (3) a successful non-pharmacological real-time stimulation to shorten the duration of sleep falling by 24.1 min. Conclusively, our solution exceeds existing ones in promoting fast falling asleep, tracking sleep state accurately, and achieving high social acceptance through a reliable large-scale evaluation.


Asunto(s)
Trastornos del Inicio y del Mantenimiento del Sueño , Dispositivos Electrónicos Vestibles , Humanos , Estimulación Acústica , Sueño/fisiología , Polisomnografía
20.
Adv Sci (Weinh) ; 10(36): e2306111, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37904645

RESUMEN

Wearable and implantable microscale electronic sensors have been developed for a range of biomedical applications. The sensors, typically millimeter size silicon microchips, are sought for multiple sensing functions but are severely constrained by size and power. To address these challenges, a hardware programmable application-specific integrated circuit design is proposed and post-process methodology is exemplified by the design of battery-less wireless microchips. Specifically, both mixed-signal and radio frequency circuits are designed by incorporating metal fuses and anti-fuses on the top metal layer to enable programmability of any number of features in hardware of the system-on-chip (SoC) designs. This is accomplished in post-foundry editing by combining laser ablation and focused ion beam processing. The programmability provided by the technique can significantly accelerate the SoC chip development process by enabling the exploration of multiple internal circuit parameters without the requirement of additional programming pads or extra power consumption. As examples, experimental results are described for sub-millimeter size complementary metal-oxide-semiconductor microchips being developed for wireless electroencephalogram sensors and as implantable microstimulators for neural interfaces. The editing technique can be broadly applicable for miniaturized biomedical wearables and implants, opening up new possibilities for their expedited development and adoption in the field of smart healthcare.


Asunto(s)
Prótesis e Implantes , Dispositivos Electrónicos Vestibles , Semiconductores , Diseño de Equipo , Silicio