Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
JACC Cardiovasc Imaging ; 17(1): 31-42, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37178073

RESUMEN

BACKGROUND: Aortic valve calcification (AVC) is a principal mechanism underlying aortic stenosis (AS). OBJECTIVES: This study sought to determine the prevalence of AVC and its association with the long-term risk for severe AS. METHODS: Noncontrast cardiac computed tomography was performed among 6,814 participants free of known cardiovascular disease at MESA (Multi-Ethnic Study of Atherosclerosis) visit 1. AVC was quantified using the Agatston method, and normative age-, sex-, and race/ethnicity-specific AVC percentiles were derived. The adjudication of severe AS was performed via chart review of all hospital visits and supplemented with visit 6 echocardiographic data. The association between AVC and long-term incident severe AS was evaluated using multivariable Cox HRs. RESULTS: AVC was present in 913 participants (13.4%). The probability of AVC >0 and AVC scores increased with age and were generally highest among men and White participants. In general, the probability of AVC >0 among women was equivalent to men of the same race/ethnicity who were approximately 10 years younger. Incident adjudicated severe AS occurred in 84 participants over a median follow-up of 16.7 years. Higher AVC scores were exponentially associated with the absolute risk and relative risk of severe AS with adjusted HRs of 12.9 (95% CI: 5.6-29.7), 76.4 (95% CI: 34.3-170.2), and 380.9 (95% CI: 169.7-855.0) for AVC groups 1 to 99, 100 to 299, and ≥300 compared with AVC = 0. CONCLUSIONS: The probability of AVC >0 varied significantly by age, sex, and race/ethnicity. The risk of severe AS was exponentially higher with higher AVC scores, whereas AVC = 0 was associated with an extremely low long-term risk of severe AS. The measurement of AVC provides clinically relevant information to assess an individual's long-term risk for severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Masculino , Humanos , Femenino , Válvula Aórtica/diagnóstico por imagen , Calcio , Prevalencia , Valor Predictivo de las Pruebas , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología
2.
J Med Invest ; 70(3.4): 450-456, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37940531

RESUMEN

Aortic valve calcification (AVC), which causes aortic stenosis (AS), is more common in elderly persons. Controlling for conventional risk variables did not, however, reduce the incidence of AS. Thus, residual risk factors of AS should be identified. We enrolled 513 patients who underwent coronary angiography with computed tomography because of suspicion of coronary artery disease (CAD) or ruling out of CAD before aortic valve replacement. Calcium volume was calculated with a commercially available application. Conventional and lipid-related risk factors including serum levels of Lp(a) were evaluated for all patients. Calcium volume and Lp(a) levels were significantly higher in patients who underwent aortic valve replacement than in those who did not. A single regression analysis showed that the calcium volume was positively associated with age and the Lp(a) levels and negatively associated with the estimated glomerular filtration rate. No statistical significance was observed for other risk factors, including oxidized low-density lipoprotein, omega-3 fatty acids levels. The multiple regression analysis revealed that age (P<0.001), female sex (P<0.05), Lp(a) (P<0.01), and hemoglobin A1c (P<0.01) were determinants of the calcium volume. The area under the curve in receiver operating characteristic analysis of Lp(a) for implementation of AVR was 0.65 at an Lp(a) cut-off level of 16 mg/dL. In conclusion, the serum Lp(a) level is a potent risk factor of AVC in patients with high risk of atherosclerosis. J. Med. Invest. 70 : 450-456, August, 2023.


Asunto(s)
Estenosis de la Válvula Aórtica , Aterosclerosis , Enfermedad de la Arteria Coronaria , Humanos , Femenino , Anciano , Válvula Aórtica/diagnóstico por imagen , Lipoproteína(a) , Calcio , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Aterosclerosis/etiología , Factores de Riesgo , Enfermedad de la Arteria Coronaria/etiología
3.
Vasc Endovascular Surg ; 57(8): 949-953, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37309678

RESUMEN

PURPOSE: Abdominal aortic aneurysms (AAA) are observed in 6% of patients with concomitant aortic valve stenosis (AS) requiring aortic valve replacement. Optimal management of these concomitant pathologies is still debated. CASE REPORT: An 80-year-old man presented with acute heart failure due to a severe AS. Past medical history included AAA under regular surveillance. A thoracic and abdominal computed tomography angiography (CTA) confirmed a 6 mm increase of AAA over an 8-month period (max 55 mm). A multidisciplinary team prescribed a simultaneous endovascular approach of transcatheter aortic valve implantation (TAVI) followed by endovascular aneurysm repair (EVAR) under local anaesthesia with bilateral femoral percutaneous access. No intra or post-procedural complications were registered; technical success was confirmed by completion angiography and post-operative ultrasound. The patient was discharged on postoperative day 5. A 2-month post-operative CTA confirmed ongoing technical success. CONCLUSION: Combined TAVI and EVAR under local anaesthesia for AS and AAA was associated with reduced hospital stay and technical success at 2 months from intervention in this case report.


Asunto(s)
Aneurisma de la Aorta Abdominal , Estenosis de la Válvula Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Humanos , Masculino , Anestesia Local , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Válvula Aórtica , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Implantación de Prótesis Vascular/métodos , Reparación Endovascular de Aneurismas , Procedimientos Endovasculares/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
4.
Altern Ther Health Med ; 29(6): 294-299, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37318894

RESUMEN

Objective: This assessed the value of real-time three-dimensional echocardiography in patients with aortic valve lesions before and after transcatheter aortic valve implantation. Methods: A total of 61 patients were admitted for transcatheter aortic valve implantation due to aortic valve lesions between October 2021 and August 2022 (research group), and 55 patients who underwent a healthy physical examination during the same period (control group) were included. All participants underwent real-time three-dimensional echocardiography. Changes in left ventricular end-diastolic volume index, left ventricular end-systolic volume index, left ventricular ejection fraction, maximum velocity, and left ventricular mass index were observed at 1 week and 1 month after the surgery. Additionally, the research group was further divided based on the type of lesion to investigate the differences in real-time three-dimensional echocardiography findings between patients with moderate to severe aortic stenosis and moderate to severe aortic insufficiency. The occurrence of postoperative complications in the research group was also recorded to assess the role of real-time three-dimensional echocardiography in postoperative complication assessment after transcatheter aortic valve implantation. Results: Preoperative left ventricular ejection fraction did not differ significantly between the two groups (P > .05). However, the research group exhibited higher preoperative left ventricular end-diastolic volume index, left ventricular end-systolic volume index, left ventricular mass index, and maximum velocity compared to the control group (P < .05). At 1 week postoperatively, the research group showed significant reductions in left ventricular end-diastolic volume index, left ventricular end-systolic volume index, left ventricular mass index, and maximum velocity compared to preoperative values (P < .05). Furthermore, at 1 month postoperatively, the left ventricular mass index was further reduced (P < .05). Among the research group, patients with aortic stenosis had lower preoperative left ventricular end-diastolic volume index and left ventricular end-systolic volume index compared to patients with aortic insufficiency, while maximum velocity was higher (P < .05). Patients who experienced postoperative complications after transcatheter aortic valve implantation had lower left ventricular end-diastolic volume index, left ventricular end-systolic volume index and left ventricular mass index, and higher maximum velocity before and at 1 week after surgery (P < .05). Conclusions: Real-time three-dimensional echocardiography demonstrated excellent assessment capabilities for aortic valve lesions and accurately guided the determination of left ventricular mass index, showcasing its significant clinical applications.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía Tridimensional , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen
5.
Methodist Debakey Cardiovasc J ; 19(3): 105-107, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37213873

RESUMEN

Aortic stenosis is the most common valvular heart disease in the elderly population. Since the advent of transcatheter aortic valve implantation (TAVI) in 2002, the clinical indications for this alternative to a surgical replacement have continually expanded. While the treatment of octo- and nonagenarians can present significant challenges, here we present a case of TAVI in an elderly patient. Given her suitable anatomy and active lifestyle that had been limited by her disease state, the patient successfully underwent TAVI 3 weeks later and was discharged post-operative day 1. This case is the basis for providing five key points to remember about the work-up for TAVI for severe aortic stenosis in the elderly population.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo
6.
Int J Cardiol ; 384: 107-111, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37119944

RESUMEN

BACKGROUND: Data on the epidemiology of aortic stenosis (AS) are primarily derived from single center experiences and administrative claims data that do not delineate by degree of disease severity. METHODS: An observational cohort study of adults with echocardiographic AS was conducted January 1st, 2013-December 31st, 2019 at an integrated health system. The presence/grade of AS was based on physician interpretation of echocardiograms. RESULTS: A total of 66,992 echocardiogram reports for 37,228 individuals were identified. The mean ± standard deviation (SD) age was 77.5 ± 10.5, 50.5% (N = 18,816) were women, and 67.2% (N = 25,016) were non-Hispanic whites. The age-standardized AS prevalence increased from 589 (95% Confidence Interval [CI] 580-598) to 754 (95% CI 744-764) cases per 100,000 during the study period. The age-standardized AS prevalences were similar in magnitude among non-Hispanic whites (820, 95% CI 806-834), non-Hispanic blacks (728, 95% CI 687-769), and Hispanics (789, 95% CI 759-819) and substantially lower for Asian/Pacific Islanders (511, 95% CI 489-533). Finally, the distribution of AS by degree of severity remained relatively unchanged over time. CONCLUSIONS AND RELEVANCE: The population prevalence of AS has grown considerably over a short timeframe although the distribution of AS severity has remained stable.


Asunto(s)
Estenosis de la Válvula Aórtica , Femenino , Humanos , Masculino , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Negro o Afroamericano , Hispánicos o Latinos , Prevalencia , Estados Unidos , Blanco , Anciano , Anciano de 80 o más Años , Asiático Americano Nativo Hawáiano y de las Islas del Pacífico
7.
Circulation ; 145(18): 1387-1397, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-35465686

RESUMEN

BACKGROUND: Menaquinone-7 (MK-7), also known as vitamin K2, is a cofactor for the carboxylation of proteins involved in the inhibition of arterial calcification and has been suggested to reduce the progression rate of aortic valve calcification (AVC) in patients with aortic stenosis. METHODS: In a randomized, double-blind, multicenter trial, men from the community with an AVC score >300 arbitrary units (AU) on cardiac noncontrast computer tomography were randomized to daily treatment with tablet 720 µg MK-7 plus 25 µg vitamin D or matching placebo for 24 months. The primary outcome was the change in AVC score. Selected secondary outcomes included change in aortic valve area and peak aortic jet velocity on echocardiography, heart valve surgery, change in aortic and coronary artery calcification, and change in dp-ucMGP (dephosphorylated-undercarboxylated matrix Gla-protein). Safety outcomes included all-cause death and cardiovascular events. RESULTS: From February 1, 2018, to March 21, 2019, 365 men were randomized. Mean age was 71.0 (±4.4) years. The mean (95% CI) increase in AVC score was 275 AU (95% CI, 225-326 AU) and 292 AU (95% CI, 246-338 AU) in the intervention and placebo groups, respectively. The mean difference on AVC progression was 17 AU (95% CI, -86 to 53 AU; P=0.64). The mean change in aortic valve area was 0.02 cm2 (95% CI, -0.09 to 0.12 cm2; P=0.78) and in peak aortic jet velocity was 0.04 m/s (95% CI, -0.11 to 0.02 m/s; P=0.21). The progression in aortic and coronary artery calcification score was not significantly different between patients treated with MK-7 plus vitamin D and patients receiving placebo. There was no difference in the rate of heart valve surgery (1 versus 2 patients; P=0.99), all-cause death (1 versus 4 patients; P=0.37), or cardiovascular events (10 versus 10 patients; P=0.99). Compared with patients in the placebo arm, a significant reduction in dp-ucMGP was observed with MK-7 plus vitamin D (-212 pmol/L versus 45 pmol/L; P<0.001). CONCLUSIONS: In elderly men with an AVC score >300 AU, 2 years MK-7 plus vitamin D supplementation did not influence AVC progression. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03243890.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica/cirugía , Calcinosis , Femenino , Humanos , Masculino , Vitamina D/uso terapéutico , Vitamina K 2/farmacología , Vitamina K 2/uso terapéutico
8.
Ann Thorac Surg ; 113(5): 1499-1504, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34139187

RESUMEN

BACKGROUND: Undertreatment of heart valve disease creates unnecessary patient risk. Poorly integrated healthcare data systems are unequipped to solve this problem. A software program using a rules-based algorithm to search the electronic health record for heart valve disease among patients treated by healthcare systems in the United States may provide a solution. METHODS: A software interface allowed concurrent access to picture archiving communication systems, the electronic health record, and other sources. The software platform was created to programmatically run a rules engine to search structured and unstructured data for identification of moderate or severe heart valve disease using guideline-reported values. Incidence and progression of disease as well as compliance with a care pathway were assessed. RESULTS: In 2 health institutions in the United States 60,145 patients had 77,215 echocardiograms. Moderate or severe aortic stenosis (AS) was identified at a rate of 9.1% of patients (5474 and 6910 echocardiograms) in this population. The precision and accuracy of the algorithm for the detection of moderate or severe AS was 92.9% and 98.6%, respectively. Thirty-five percent of patients (441/1265) with moderate stenosis and a subsequent echocardiogram progressed to severe stenosis (mean interval, 358 days). In 1 sample 70.3% of moderate AS patients lacked a 6-month echocardiogram or appointment. The platform enabled 100% accountability for all patients with severe AS. CONCLUSIONS: A rules-based software program enhances detection of heart valve disease and can be used to measures disease progression and care pathway compliance.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Inteligencia Artificial , Constricción Patológica , Ecocardiografía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Estados Unidos/epidemiología
9.
JACC Cardiovasc Interv ; 14(15): 1688-1703, 2021 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-34353601

RESUMEN

Transcatheter aortic valve replacement (TAVR) is a treatment option for symptomatic patients with severe aortic stenosis who are candidates for a bioprosthesis across the entire spectrum of risk. However, TAVR carries a risk for thrombotic and bleeding events, underscoring the importance of defining the optimal adjuvant antithrombotic regimen. Antithrombotic considerations are convoluted by the fact that many patients undergoing TAVR are generally elderly and present with multiple comorbidities, including conditions that may require long-term oral anticoagulation (OAC) (eg, atrial fibrillation) and antiplatelet therapy (eg, coronary artery disease). After TAVR among patients without baseline indications for OAC, recent data suggest dual-antiplatelet therapy to be associated with an increased risk for bleeding events, particularly early postprocedure, compared with single-antiplatelet therapy with aspirin. Concerns surrounding the potential for thrombotic complications have raised the hypothesis of adjunctive use of OAC for patients with no baseline indications for anticoagulation. Although effective in modulating thrombus formation at the valve level, the bleeding hazard has shown to be unacceptably high, and the net benefit of combining antiplatelet and OAC therapy is unproven. For patients with indications for the use of long-term OAC, such as those with atrial fibrillation, the adjunctive use of antiplatelet therapy increases bleeding. Whether direct oral anticoagulant agents achieve better outcomes than vitamin K antagonists remains under investigation. Overall, single-antiplatelet therapy and OAC appear to be reasonable strategies in patients without and with indications for concurrent anticoagulation. The aim of the present review is to appraise the current published research and recommendations surrounding the management of antithrombotic therapy after TAVR, with perspectives on evolving paradigms and ongoing trials.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anticoagulantes/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Fibrinolíticos/efectos adversos , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Ann Vasc Surg ; 73: 585-588, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33556523

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has proven over the years to be a viable alternative to open surgery. A rare but severe complication is represented by the valve migration. We report a case of TAVI complication due to the loss of the prosthetic valve in the abdominal aorta treated by endovascular approach. METHODS: An 88-year-old patient with severe aortic valve stenosis, symptomatic for dyspnea was proposed for a TAVI because considered at high risk for surgery. During the TAVI procedure, the undeployed device (Edwards SAPIEN 3 - Edwards Lifesciences, Irvine, CA, USA) detached from its delivery system. Several attempts to withdraw the valve fluctuating in the aorta into its supporting system were performed without success. An emergency endovascular treatment was promptly planned to obtain the exclusion from the flow of the embolized valve. Under local anaesthesia, through the percutaneous femoral access already present, a tube aortic endograft (EndurantTM II, Medtronic, Santa Rosa, CA; ETTF2828C70EE) was successfully introduced and deployed in the infrarenal aorta without any related complications. The embolized valve was completely covered by the endgraft and thus fixed to the aortic wall. The first postoperative computer tomography angiography (CTA) confirmed the correct placement of the endograft, the exclusion of the valve from the flow and the patency of the great vessels. No perioperative or postoperative complications were recorded. The patient was discharged on the ninth postoperative day with the indication to a new attempt of TAVI, through transapical access. CONCLUSIONS: In case of intraprocedural loss of an undeplyed valve during TAVI, the valve fixing through endograft deployment in infrarenal aorta is a possible solution.


Asunto(s)
Aorta Abdominal , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Migración de Cuerpo Extraño/etiología , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Procedimientos Endovasculares , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/terapia , Humanos , Masculino , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
11.
Cardiovasc Revasc Med ; 23: 7-13, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33281073

RESUMEN

BACKGROUND: The axillary artery is an alternative route for patients with comorbidities and unfavorable femoral arteries who need transcatheter aortic valve replacement (TAVR). Simplified trans-axillary transcatheter aortic valve replacement (TAx-TAVR) implies a completely percutaneous approach under local anesthesia and arteriotomy closure with vascular closure techniques. Herein, we report on early experience with simplified TAx-TAVR under local anesthesia. METHODS: We enrolled all consecutive patients who underwent simplified TAx-TAVR in our center. Main study parameter was the incidence of axillary access related major vascular complications within 30 days. Secondary parameters included a composite early safety endpoint, axillary access-site related vascular/bleeding complications and short-term mortality. Post TAVR axillary stent patency was evaluated during follow-up by CT-analysis. RESULTS: Between July 2018 and April 2020, Tax-TAVR was attempted in 35 patients with a mean age of 79 years. Local anesthesia and conscious sedation were used in 91.4% (n = 32) and 8.6% (n = 3) respectively. A covered stent was needed for complete axillary hemostasis in 44.1% (n = 15). Device success was achieved in 91.2% (n = 31/34). The 30-day axillary artery major vascular and ≥major bleeding complication rates were 14% (n = 5) and 11% (n = 4). The early safety endpoint was reached in 22.9% (n = 8). Mortality rates at 30 days and six months were 2.9% and 11.6%. Computed tomography (CT) confirmed axillary stent patency during follow-up in 82% (n = 9/11). CONCLUSIONS: In patients with high/prohibitive surgical risk and unsuitable femoral access, simplified TAx-TAVR under local anesthesia offers a valuable alternative for transfemoral TAVR but requires advanced access site management techniques including covered stents. Our data suggest an unmet clinical need for dedicated TAx closure devices.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anestesia Local/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Recién Nacido , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
Thorac Cardiovasc Surg ; 69(5): 461-465, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33075824

RESUMEN

As part of an institutionally driven holistic concept, named the "360-degree approach," all established surgical access routes -full sternotomy, partial upper sternotomy, and right anterolateral thoracotomy using the second interspace-are supported. The surgical toolbox now is completed by adding a further approach: through a 5- to7-cm skin incision in the right anterior axillary line, the third interspace is used for a minimally invasive aortic valve surgery providing striking exposition of the aortic valve and resulting in superior cosmetics with nearly no visible scars. The choice for the one or other method is institutionally driven and based on risk profiles, as well as anatomical and physiognomic considerations.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cicatriz/prevención & control , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Cicatriz/etiología , Toma de Decisiones Clínicas , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Selección de Paciente , Resultado del Tratamiento
13.
J Cardiovasc Med (Hagerstown) ; 21(11): 905-911, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32858630

RESUMEN

BACKGROUND: Vitamin D [25(OH)D] deficiency and degenerative aortic stenosis represent emerging conditions, linked to a progressive ageing of the population and increased frailty. Previous studies have associated lower levels of 25 (OH)D to the pathogenesis of atherosclerosis and vascular calcifications. However, few studies have evaluated, so far, the impact of vitamin D deficiency in patients with aortic stenosis, which was therefore the aim of present study. METHODS: Consecutive patients with severe degenerative aortic stenosis undergoing nonurgent coronary angiography were included. Aortic stenosis was defined as aortic valve area (AVA) less than 1 cm and/or mean gradient more than 40 mmHg. Indexed area and stroke volume or dobutamine stress evaluation were performed when indicated. Fasting samples were collected at admission for 25 (OH)D levels assessment. RESULTS: We included 137 patients with severe degenerative aortic stenosis (48.9% men, mean age 78.4 ±â€Š6.4 years) who were divided according to vitamin D median values (≥12.4 ng/ml). Patients with lower vitamin D had a more frequent history of coronary artery bypass graft (P = 0.02) and received more often angiotensin-converting enzyme-inhibitors (P = 0.03). Among them, 38.7% had vitamin D levels less than 10 ng/ml and only five patients were in therapy with vitamin D supplementation. We observed no significant relationship between vitamin D levels and echocardiographic parameters for the severity of aortic stenosis (AVA, peak and mean gradients, volumes, ejection fraction) except for a greater wall thickness in patients with lower vitamin D levels (r = -0.34, P = 0.03). Results did not change when excluding patients with renal failure or treated with vitamin D supplementation. CONCLUSION: Among patients with severe degenerative aortic stenosis, vitamin D deficiency is common. We found a significant association between left ventricular wall thickness and vitamin D levels, suggesting a potential role of this hormone in modulating hypertrophic remodelling in these patients. However, future larger studies are certainly needed to confirm our findings and to define their prognostic implications.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Hipertrofia Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Remodelación Ventricular , Deficiencia de Vitamina D/sangre , Vitamina D/análogos & derivados , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Biomarcadores/sangre , Angiografía Coronaria , Ecocardiografía Doppler , Femenino , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Masculino , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Vitamina D/sangre , Deficiencia de Vitamina D/diagnóstico
14.
J Cardiovasc Med (Hagerstown) ; 21(10): 805-811, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32740417

RESUMEN

AIMS: Conscious sedation instead of general anesthesia has been increasingly adopted in many centers for transfemoral transcatheter aortic valve replacement (TAVR). Improvement of materials and operators' experience and reduction of periprocedural complications allowed procedural simplification and adoption of a minimalist approach. With this study, we sought to assess the feasibility and safety of transfemoral TAVR routinely performed under local anesthesia without on-site anesthesiology support. METHODS: The routine transfemoral TAVR protocol adopted at our center includes a minimalist approach, local anesthesia alone with fully awake patient, anesthesiologist available on call but not in the room, and direct transfer to the cardiology ward after the procedure. All consecutive patients undergoing transfemoral TAVR between January 2015 and July 2018 were included. We assessed the rates of actual local anesthesia-only procedures, conversion to conscious sedation or general anesthesia and 30-day clinical outcomes. RESULTS: Among 321 patients, 6 received general anesthesia upfront and 315 (98.1%) local anesthesia only. Mean age of the local anesthesia group was 83.2 ±â€Š6.9 years, Society of Thoracic Surgery score 5.8 ±â€Š4.8%. A balloon-expandable valve was used in 65.7%. Four patients (1.3%) shifted to conscious sedation because of pain or anxiety; 6 patients (1.9%) shifted to general anesthesia because of procedural complications. Hence, local anesthesia alone was possible in 305 patients (96.8% of the intended cohort, 95% of all transfemoral procedures). At 30 days, in the intended local anesthesia group, mortality was 1.6%, stroke 0.6%, major vascular complications 2.6%. Median hospital stay was 4 days (IQR 3-7). CONCLUSION: Transfemoral TAVR can be safely performed with local anesthesia alone and without an on-site anesthesiologist in the vast majority of patients.


Asunto(s)
Anestesia Local , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Anestesia General , Anestesia Local/efectos adversos , Anestesia Local/mortalidad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Sedación Consciente , Estudios de Factibilidad , Femenino , Humanos , Tiempo de Internación , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/mortalidad , Seguridad del Paciente , Complicaciones Posoperatorias/mortalidad , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
15.
BMC Nephrol ; 21(1): 203, 2020 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-32471374

RESUMEN

BACKGROUND: Patients with chronic kidney disease (CKD) reportedly have a high prevalence of aortic valve calcification (AVC). In population-based studies, AVC is considered a manifestation of systemic atherosclerosis. The association of AVC with atherosclerotic lesions has not been fully investigated in predialysis patients. The present study was performed to determine whether carotid artery lesions and peripheral artery disease (PAD) are associated with AVC in patients with CKD not on dialysis. METHODS: In total, 749 patients were included in this cross-sectional study. AVC was evaluated using echocardiography. Carotid artery lesions including carotid artery plaque (CAP) and PAD were simultaneously examined in each patient. A logistic regression analysis was applied to determine the factors associated with AVC. RESULTS: AVC, CAP, and PAD were found in 201, 583, and 123 patients, respectively. In the multivariable analyses adjusted for covariates including the estimated glomerular filtration rate and makers of mineral metabolism (serum calcium, serum phosphorus, parathyroid hormone, 1,25-dihydroxyvitamin D, and fibroblast growth factor 23), AVC was significantly associated with the presence of CAP [odds ratio (OR), 3.37; 95% confidence interval (CI), 1.43-7.95], the presence of PAD (OR, 1.76; 95% CI, 1.10-2.81), the CAP score (per 1.0-point increase) (OR, 1.06; 95% CI, 1.02-1.11), and the ankle-brachial blood pressure index (per 0.1-point increase) (OR, 0.83; 95% CI, 0.72-0.95). CONCLUSIONS: AVC was associated with atherosclerotic lesions independent of kidney function and mineral metabolism. We consider that this association between AVC and atherosclerosis might reflect the burden of shared atherosclerotic risk factors.


Asunto(s)
Estenosis de la Válvula Aórtica/epidemiología , Válvula Aórtica/patología , Calcinosis/epidemiología , Enfermedades de las Arterias Carótidas/epidemiología , Enfermedad Arterial Periférica/epidemiología , Insuficiencia Renal Crónica/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Índice Tobillo Braquial , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Calcio/sangre , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/fisiopatología , Estudios Transversales , Ecocardiografía , Femenino , Factor-23 de Crecimiento de Fibroblastos , Factores de Crecimiento de Fibroblastos/sangre , Humanos , Lansoprazol , Masculino , Persona de Mediana Edad , Hormona Paratiroidea/sangre , Fósforo/sangre , Insuficiencia Renal Crónica/fisiopatología , Vitamina D/análogos & derivados , Vitamina D/sangre , Adulto Joven
16.
Cardiovasc Revasc Med ; 21(5): 594-601, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31523003

RESUMEN

BACKGROUND/PURPOSE: General Anesthesia (GA) and conscious sedation (CS) are anesthetics for transfemoral transcatheter aortic valve replacement (TF-TAVR). We compared TF-TAVR outcomes using a novel anesthetic approach with fascia iliaca block (FIB) plus minimal CS (MCS) versus GA. METHODS: This retrospective propensity-matched study included consecutive TF-TAVR patients from January 2013 to December 2017 and dichotomized into FIB-MCS vs. GA. Data were collected from electronic records, Society of Thoracic Surgery (STS) database, and the Transcatheter Valve Therapies (TVT) Registry. Primary endpoints were operating room (OR) time, intensive care unit (ICU) and hospital length of stay (LOS). Secondary endpoints were 30-day, 1-year mortality, quality of life, 30-day re-hospitalization rate, failure of FIB-MCS, and hospital safety outcomes. RESULTS: A total of 304 TF-TAVR patients; FIB-MCS (n = 219) vs. GA (n = 85). Propensity matched 162 patients; FIB-MCS (n = 108) vs. GA (n = 54). FIB-MCS had shorter OR time (197.6 ±â€¯56.3 vs. 248.2 ±â€¯46.3 min, p < 0.001), ICU (67.8 ±â€¯71.7 vs. 84.9 ±â€¯72.1 h, p = 0.004) and hospital LOS (3.2 ±â€¯3.7 vs. 5.9 ±â€¯3.5 d, p < 0.001). FIB-MCS had lower rate of blood transfusion. FIB-MCA vs. GA 30-day and 1-year mortality were similar in the entire (2.3 vs. 2.4%, p = 1.0; and 8.2 vs. 5.9%, p = 0.49) and matched cohorts (0 vs. 3.7%, p = 0.11 and 7.4 vs. 5.6%, p = 0.75). FIB-MCS were less likely to be re-hospitalized [Odd Ratio: 0.32, CI:0.13-0.76] and 2% to 3% higher KCCQ-12 score. CONCLUSION: TF-TAVR using FIB-MCS is feasible and safe with shorter OR time, ICU and hospital LOS, lower risk of 30-day re-hospitalization, similar 30-day and 1-year mortality with better quality of life at 1-year follow-up.


Asunto(s)
Anestesia General , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico , Sedación Consciente , Arteria Femoral , Bloqueo Nervioso , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Anestesia General/efectos adversos , Anestesia General/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Sedación Consciente/efectos adversos , Sedación Consciente/mortalidad , Bases de Datos Factuales , Registros Electrónicos de Salud , Femenino , Humanos , Tiempo de Internación , Masculino , Bloqueo Nervioso/efectos adversos , Bloqueo Nervioso/mortalidad , Tempo Operativo , Readmisión del Paciente , Punciones , Calidad de Vida , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 95(1): 45-53, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31038290

RESUMEN

OBJECTIVES: To demonstrate safety, feasibility and short-term clinical outcomes after transcatheter aortic valve-in-valve (ViV) implantation under local anesthesia without contrast aortography or echocardiographic guidance. BACKGROUND: Transcatheter ViV implantation is an emerging treatment modality for patients with degenerative surgical bioprostheses. Given the radiopaque properties of the surgical aortic valve (SAV) frame, ViV procedures can often be performed with fluoroscopic guidance alone. METHODS: ViV implantation was performed in 37 patients with SAV failure under local anesthesia without contrast aortography. Clinical and echocardiographic data were obtained at baseline, discharge, and 30 days. RESULTS: Mean age was 74 ± 10 years and STS predicted risk of mortality was 5.6 ± 2.4%. Mean transaortic gradient decreased from 39.4 ± 15.5 mmHg to 13 ± 6.3 mmHg at discharge (p < .001), and 20 ± 7.5 mmHg at 30 days (p < .001 compared to baseline), aortic valve area increased from 0.9 ± 0.3 cm2 to 1.2 ± 0.4 cm2 at 30 days (p = .007). No patient had more than mild aortic regurgitation. Hospital discharge occurred at a median of 2.6 ± 4.4 days. At 30-day follow-up there were no deaths, myocardial infarctions, strokes, repeat hospital admissions for heart failure, or renal failure. One patient (2.7%) required a new pacemaker. 93% of the patients were in New York Heart Association functional class I or II. CONCLUSIONS: Transcatheter aortic ViV implantation for selected patients with degenerative surgical bioprostheses under local anesthesia without aortography or echocardiographic guidance is feasible and safe.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Anestesia Local , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
18.
JACC Cardiovasc Imaging ; 12(2): 267-282, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30732722

RESUMEN

Up to 40% of patients with aortic stenosis (AS) present with a "discordant grading" usually referred to as "low-gradient AS." This article presents a step-by-step integrative approach overview of the utility, limitations, and complementary role of the different imaging modalities for the assessment of AS severity with a special emphasis on the reconciliation of discordant grading. The first step is to confirm the validity of echocardiographic measures of AS severity. For example, hybrid imaging can combine left ventricular outflow tract area measured by 3-dimensional echocardiography or contrast enhanced multidetector row computed tomography with flow velocities measured by Doppler. The next step is to differentiate severe from non-severe AS with the use of low-dose dobutamine stress echocardiography, especially in patients with low left ventricular ejection fraction, low-flow, low-gradient AS. Aortic valve calcium scoring measured by noncontrast multidetector row computed tomography is preferred in patients with low-gradient AS and preserved left ventricular ejection fraction as well as in those with inconclusive results with dobutamine stress echocardiography.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Imagen Multimodal/métodos , Tomografía Computarizada por Rayos X , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/fisiopatología , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
20.
BMC Cardiovasc Disord ; 18(1): 231, 2018 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-30526521

RESUMEN

Transcatheter aortic valve implantation (TAVI) has become an established therapeutic option for patients with symptomatic, severe aortic valve stenosis. Ageing of the Western and Asian population and expansion of indications for TAVI will lead to a substantial increase in the number of TAVI procedures performed worldwide within the next decades. In line with the maturation of TAVI over the past few years, there has also been a significant simplification and optimisation of the TAVI procedure. A minimalist TAVI procedure and fast-track TAVI course have been shown to have distinct advantages over the more traditional TAVI approach. The aim of this manuscript is to discuss strategies of TAVI simplification and optimization, with special focus on fast-track TAVI, without compromising safety and efficacy.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Vías Clínicas/organización & administración , Prestación Integrada de Atención de Salud/organización & administración , Evaluación de Procesos y Resultados en Atención de Salud/organización & administración , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Toma de Decisiones Clínicas , Dinamarca , Eficiencia Organizacional , Estado de Salud , Hemodinámica , Humanos , Tiempo de Internación , Seguridad del Paciente , Complicaciones Posoperatorias/prevención & control , Desarrollo de Programa , Evaluación de Programas y Proyectos de Salud , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Flujo de Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA