Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 271
Filtrar
Más filtros

Medicinas Complementárias
Tipo del documento
Intervalo de año de publicación
2.
Herzschrittmacherther Elektrophysiol ; 35(Suppl 1): 68-76, 2024 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-38424340

RESUMEN

The first permanent biventricular pacing system was implanted more than 30 years ago. In this article, the historical development of cardiac resynchronization therapy (CRT), starting with the pathophysiological concept, followed by the initial "proof of concept" studies and finally the large prospective-randomized studies that led to the implementation of CRT in heart failure guidelines, is outlined. Since the establishment of CRT, both an expansion of indications, e.g., for patients with mild heart failure and atrial fibrillation, but also the return to patients with broad QRS complex and left bundle branch block who benefit most of CRT has evolved. New techniques such as conduction system pacing will have major influence on pacemaker therapy in heart failure, both as an alternative or adjunct to CRT.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Fascículo Atrioventricular , Estudios Prospectivos , Electrocardiografía/métodos , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia
3.
JACC Clin Electrophysiol ; 9(2): 209-218, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36858687

RESUMEN

BACKGROUND: Direct slow pathway capture (DSPC) mapping is a novel electrophysiological technique for detecting antegrade slow pathway input sites. However, the effect of DSPC mapping-guided ablation on atrioventricular nodal re-entrant tachycardia (AVNRT) is unknown. OBJECTIVES: This study aimed to evaluate the efficacy and safety of DSPC mapping-guided ablation in typical AVNRT patients. METHODS: A multicenter retrospective study was conducted in 301 consecutive typical AVNRT patients. The outcomes in patients who underwent DSPC mapping-guided ablation (DSPC group) and those who underwent conventional anatomical ablation (conventional group) were compared. The conventional group was established before introducing DSPC mapping-guided ablation. Positive DSPC sites were defined as sites with a return cycle atrioventricular prolongation of ≥20 ms with high-output (10-20 V) pacing during tachycardia or the last paced beat of the atrial extrastimulation. RESULTS: Among 116 patients in the DSPC group, 102 (88%) had positive DSPC sites, and 86 (74%) had a successful ablation at that site. Of the remaining 30 patients, 27 had a successful anatomical ablation. The DSPC group had a significantly lower frequency of radiofrequency applications and shorter total application time than the conventional group (median: 5.5 [IQR: 3-11] times vs 9 [IQR: 5-15] times, and 168 [IQR: 108-266] seconds vs 244 [IQR: 158-391] seconds, respectively; P < 0.01). Moreover, the DSPC group had a numerically lower incidence of permanent pacemaker implantations and AVNRT recurrences than the conventional group (0% vs 1.6%; P = 0.17, and 1.7% vs 3.2%; P = 0.43, respectively). CONCLUSIONS: DSPC mapping-guided ablation was associated with a lower operative time, which can reduce the risk of AV conduction injury in typical AVNRT.


Asunto(s)
Terapia por Estimulación Eléctrica , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Estudios Retrospectivos , Fascículo Atrioventricular , Atrios Cardíacos
4.
JACC Clin Electrophysiol ; 9(3): 425-441, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36990601

RESUMEN

Junctional tachycardia (JT) is typically considered to have an automatic mechanism originating from the distal atrioventricular node. When there is 1:1 retrograde conduction via the fast pathway, JT would resemble the typical form of atrioventricular nodal re-entrant tachycardia (AVNRT). Atrial pacing maneuvers have been proposed to exclude AVNRT and suggest a diagnosis of JT. However, after excluding AVNRT, one should consider the possibility of an infra-atrial narrow QRS re-entrant tachycardia, which can exhibit features that resemble AVNRT as well as JT. Pacing maneuvers and mapping techniques should be performed to assess for infra-atrial re-entrant tachycardia before concluding that JT is the mechanism of a narrow QRS tachycardia. Distinguishing JT from typical AVNRT or infra-atrial re-entrant tachycardia has notable implications regarding the approach to ablation of the tachycardia. Ultimately, a contemporary review of the evidence on JT raises some questions as to the mechanism and source of what has traditionally been considered JT.


Asunto(s)
Fibrilación Atrial , Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Ectópica de Unión , Taquicardia Supraventricular , Humanos , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Ectópica de Unión/diagnóstico , Nodo Atrioventricular , Fascículo Atrioventricular , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía
5.
Eur J Heart Fail ; 25(2): 274-283, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36404397

RESUMEN

AIMS: Excessive prolongation of PR interval impairs coupling of atrio-ventricular (AV) contraction, which reduces left ventricular pre-load and stroke volume, and worsens symptoms. His bundle pacing allows AV delay shortening while maintaining normal ventricular activation. HOPE-HF evaluated whether AV optimized His pacing is preferable to no-pacing, in a double-blind cross-over fashion, in patients with heart failure, left ventricular ejection fraction (LVEF) ≤40%, PR interval ≥200 ms and either QRS ≤140 ms or right bundle branch block. METHODS AND RESULTS: Patients had atrial and His bundle leads implanted (and an implantable cardioverter-defibrillator lead if clinically indicated) and were randomized to 6 months of pacing and 6 months of no-pacing utilizing a cross-over design. The primary outcome was peak oxygen uptake during symptom-limited exercise. Quality of life, LVEF and patients' holistic symptomatic preference between arms were secondary outcomes. Overall, 167 patients were randomized: 90% men, 69 ± 10 years, QRS duration 124 ± 26 ms, PR interval 249 ± 59 ms, LVEF 33 ± 9%. Neither peak oxygen uptake (+0.25 ml/kg/min, 95% confidence interval [CI] -0.23 to +0.73, p = 0.3) nor LVEF (+0.5%, 95% CI -0.7 to 1.6, p = 0.4) changed with pacing but Minnesota Living with Heart Failure quality of life improved significantly (-3.7, 95% CI -7.1 to -0.3, p = 0.03). Seventy-six percent of patients preferred His bundle pacing-on and 24% pacing-off (p < 0.0001). CONCLUSION: His bundle pacing did not increase peak oxygen uptake but, under double-blind conditions, significantly improved quality of life and was symptomatically preferred by the clear majority of patients. Ventricular pacing delivered via the His bundle did not adversely impact ventricular function during the 6 months.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Masculino , Humanos , Femenino , Fascículo Atrioventricular , Estudios Cruzados , Volumen Sistólico , Calidad de Vida , Tolerancia al Ejercicio , Función Ventricular Izquierda , Oxígeno , Resultado del Tratamiento , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos
6.
Med Eng Phys ; 107: 103847, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36068029

RESUMEN

His bundle pacing (HBP) has emerged as a feasible alternative to right (RVP) and biventricular pacing (BVP) for Cardiac Resynchronization Therapy (CRT). This study sought to assess, in ex-vivo experimental models, the optimal setup for HBP in terms of electrode placement and pacing protocol to achieve superior electrical synchrony in the case of complete His-Purkinje block and left bundle branch block (LBBB). We developed a 3D model of His bundle and bundle branches, embedded in a patient-specific biventricular heart model reconstructed from CT images. A monodomain reaction-diffusion model was adopted to describe the propagation of cardiac action potential, and a custom procedure was developed to compute pseudo-ECGs. Experimental measurements of tip electrode potential waveforms have been performed on ex-vivo swine myocardium to determine the appropriate boundary condition for delivering the electrical stimulus in the numerical model. An extended parametric analysis, investigating the effect of the electrode orientation and helix length, pacing protocol, and atrioventricular delay, allowed us to determine the optimal setup for HBP therapy. Both selective (S-HBP) and non-selective (NS-HBP) His bundle pacing were tested, as the variable anatomical location of the His bundle can result in the activation of the surrounding myocardium. Our study indicates a perpendicular placement of the electrode as the most advantageous for restoring the physiological function of the His-Purkinje system. We found that higher-energy protocols can compensate for the effects of an angled placement though concurring to potential tip fibrosis. Promisingly, we also revealed that an increased electrode helix length can provide optimal resynchronization even with low-energy pacing protocols. Our results provide informative guidance for implant procedure and therapy optimization, which will hopefully have clinical implications further improving the procedural success rates and patients' quality of life, due to reduced incidence of lead revision and onset of complications.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Animales , Fascículo Atrioventricular , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía , Calidad de Vida , Porcinos , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Curr Opin Pediatr ; 34(5): 476-483, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36000387

RESUMEN

PURPOSE OF REVIEW: The purpose of this review is to explore the historical and serendipitous events that led to the creation of modern-day pacemakers. In addition, this review will explore how contemporary conduction site-specific pacing has overcome some of the deleterious effects from historical chronic right ventricular apical pacing. RECENT FINDINGS: Recently, there have been tremendous advances in not just the lead design but the tools required to promote more physiologic pacing. Although cardiac resynchronization pacing has been around for nearly 2 decades, this review also introduces and discusses the early results of His-bundle pacing and left bundle branch pacing and some of the potential applicability of this technology for our children. SUMMARY: Pacemakers have evolved significantly in the last 30 years through collaborative partnerships between physicians and engineers. The future of cardiac pacing is bright compared to the field of electrotherapy 50 years ago. Future iterations of pacemakers must consider unusual anatomy and growing children. Pediatric patients contribute to a small percentage of the overall device volume, but the majority of these patients will have a pacemaker for life. We need to be proactive and consider what are the best short and long-term solutions for this cohort.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Estimulación Cardíaca Artificial/métodos , Niño , Electrocardiografía/métodos , Predicción , Humanos , Resultado del Tratamiento
8.
BMC Cardiovasc Disord ; 22(1): 274, 2022 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-35715722

RESUMEN

BACKGROUND: Left bundle branch pacing (LBBP) has become a hot topic in the field of physiological pacing. However, only a few studies have described the characteristics of the intrinsic intracardiac electrogram (EGM) while placing the left bundle branch (LBB) lead. CASE PRESENTATION: Herein, we reported a case with atrial premature contractions to the ventricle during the LBBP procedure. Paced and intrinsic (supraventricular) EGMs were recorded and analyzed. CONCLUSIONS: The myocardium of the interventricular septum could be divided into four regions based on electrophysiology: the right septal area, the left septal area, the endocardium of the left ventricular septum, and the LBB area. This might guide the electrophysiological localization of the LBB lead in the septum.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Tabique Interventricular , Fascículo Atrioventricular , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Humanos , Tabique Interventricular/diagnóstico por imagen
9.
Kardiol Pol ; 80(6): 664-671, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35380007

RESUMEN

BACKGROUND: The present study aimed to evaluate the feasibility and safety of the novel left bundle branch pacing (LBBP) procedure that uses isoelectric interval as an endpoint for lead implantation. METHODS: A total of 41 patients with indications for pacing were enrolled. All patients underwent a novel LBBP procedure guided by recording an isoelectric interval as an endpoint for lead implantation. The procedural details and electrophysiological characteristics were then analyzed. RESULTS: A total of 38/41 (92.7%) cases were confirmed of left bundle branch (LBB) capture. An isoelectric interval was observed in 36/41 cases (87.8%). A total of 36/41 (87.8%) cases with LBB potential were observed. The mean unipolar LBBP threshold at the implant was 0.5 ± 0.2 V. The mean sensed amplitude of the R wave and the pacing impedance at the implant were 12.9 ± 5.0 mV and 723.5 ± 117.1 Ω. During the final threshold testing, a transition from non-selective to selective LBBP (S-LBBP) was demonstrated in 26 patients. A transition from non-selective LBBP (NS-LBBP) to left ventricular septal myocardial capture was observed in 12 patients. CONCLUSION: Using an isoelectric interval as an endpoint to guide the LBBP was feasible in a high proportion of captured LBB cases.


Asunto(s)
Fascículo Atrioventricular , Técnicas Electrofisiológicas Cardíacas , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial , Electrocardiografía/métodos , Humanos
10.
Hellenic J Cardiol ; 64: 77-86, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34843996

RESUMEN

His bundle pacing (HBP) is proven to be a safe and effective alternative pacing modality that, in addition, avoids pacemaker-induced cardiomyopathy (PICM) by achieving a "physiological" ventricular stimulation, via the native conduction system. Indications include various causes of bradycardia requiring anti-bradycardic pacing, inadequately controlled atrial fibrillation requiring AV node ablation and established PICM. In addition, HBP may also be used as an alternative therapy for patients with heart failure (HF) and an indication for cardiac resynchronization therapy (CRT). Available data show several advantages of HBP with regard to preservation or restoration of intra- and inter-ventricular synchronization; improvement in left ventricular ejection fraction, functional status and quality of life; decrease in atrial fibrillation incidence and improvement in HF hospitalization rates, compared with conventional pacing. Nevertheless, superiority in terms of mortality rates has not been consistently demonstrated, and the long-term efficacy and safety of HBP remain to be proven. In the present manuscript, we review the status of HBP and present our current experience with this novel pacing modality.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Fibrilación Atrial/terapia , Bradicardia/terapia , Fascículo Atrioventricular , Estimulación Cardíaca Artificial/efectos adversos , Electrocardiografía , Insuficiencia Cardíaca/terapia , Humanos , Calidad de Vida , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
11.
J Electrocardiol ; 70: 4-6, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34801837

RESUMEN

A 38-year-old woman with a structurally normal heart was referred for catheter ablation due to symptomatic, monomorphic, high burden (12%) premature ventricular complexes (PVC) refractory to medical therapy. The PVC's ECG morphology suggested an origin in the proximal left anterior fascicle (LAF). During procedure PVCs were mechanically suppressed. Consequently, selection of the ablation target site was based on pace-mapping. This case illustrates how ablation from the right coronary cusp (RCC) for PVC arising from the proximal LAF could be accurately guided by pace-mapping. At this location, pacing can result in both a selective and a non-selective capture of the proximal LAF.


Asunto(s)
Mapeo del Potencial de Superficie Corporal , Fascículo Atrioventricular , Ablación por Catéter , Complejos Prematuros Ventriculares , Adulto , Válvula Aórtica/cirugía , Fascículo Atrioventricular/fisiopatología , Fascículo Atrioventricular/cirugía , Ablación por Catéter/métodos , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
12.
J Cardiovasc Electrophysiol ; 32(12): 3195-3202, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34665491

RESUMEN

INTRODUCTION: His bundle pacing (HBP) and left bundle branch area pacing (LBBAP) have emerged as attractive alternatives to traditional biventricular pacing to achieve cardiac resynchronization therapy. Early reported results have been inconsistent, particularly amongst patients in whom initial placement with traditional approaches has been unsuccessful or those with complex anatomy or congenital abnormalities. In this report, we describe the use of three-dimensional electroanatomic mapping (EAM) in five selected cases. METHODS: Five patients from multiple clinical sites underwent EAM-guided HBP or LBBAP by highly trained electrophysiologists with significant experience with conduction system pacing. Each patient in this series underwent EAM-guided conduction system pacing due to complex anatomy and/or prior failed lead implantation. RESULTS: EAM-guided lead implantation was successful in all five cases. Capture thresholds were relatively low and patients continued to have evidence of successful lead implantation with minimum 1-month follow-up. The fluoroscopy time varied, likely owing to the variable complexity of the cases. CONCLUSIONS: The use of EAM, in combination with traditional intracardiac electrograms with or without fluoroscopy, allows more targeted and precise placement of leads for HBP and LBBAP pacing. Further investigation is needed to determine this strategy's long-term performance and to optimize patient selection.


Asunto(s)
Fascículo Atrioventricular , Terapia de Resincronización Cardíaca , Estimulación Cardíaca Artificial/métodos , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco , Humanos , Resultado del Tratamiento
14.
Pacing Clin Electrophysiol ; 44(11): 1907-1917, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34520042

RESUMEN

BACKGROUND: Permanent His-bundle pacing (HBP) is effective and safe; however, the success rate of HBP is low, especially in patients with infranodal block. This study aimed to assess the efficacy and feasibility of HBP implantation using an electrophysiological guided approach targeting a distal His-bundle electrogram (HBE) in patients with atrioventricular block (AVB). METHODS: Thirty-four consecutive patients with AVB (infranodal block in 28 patients) who underwent HBP were enrolled. During implantation, we attempted to target the distal part of the HBE (distal HBE) beyond the block site based on unipolar mapping. The His-capture threshold was evaluated for 1 year after implantation. RESULTS: HBP was achieved in 26 patients and in 21 patients (75%) with infranodal block. Detection of distal HBE was significantly higher in the successful HBP group than in the HBP failure group (65.4% vs. 0%, p = .001). Among 15 patients with intra-Hisian block, 14 patients (93%) successfully achieved HBP with distal HBE detection. During the 1-year follow-up period, an increase in His-capture threshold by ≥1.0 V at 1.0 ms occurred in five (19.2%) of 26 patients. The increased His-capture threshold group exhibited significantly less detection of distal HBE (20% vs. 76.2%; odds ratio 0.078, 95% confidence interval 0.07-0.87, p = .038) and a higher His-capture threshold at implantation (2.0 ± 1.1 V vs. 1.1 ± 0.9 V; odds ratio 1.702, 95% confidence interval 1.025-2.825, p = 0.04) than the non-increased His-capture threshold group. CONCLUSION: HBP implantation guided by distal HBE approach may be feasible with subsequent stable pacing in patients with intra-Hisian and atrioventricular nodal block.


Asunto(s)
Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Técnicas Electrofisiológicas Cardíacas , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino
15.
Ann Biomed Eng ; 49(12): 3143-3153, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34431016

RESUMEN

Personalized models of cardiac electrophysiology (EP) that match clinical observation with high fidelity, referred to as cardiac digital twins (CDTs), show promise as a tool for tailoring cardiac precision therapies. Building CDTs of cardiac EP relies on the ability of models to replicate the ventricular activation sequence under a broad range of conditions. Of pivotal importance is the His-Purkinje system (HPS) within the ventricles. Workflows for the generation and incorporation of HPS models are needed for use in cardiac digital twinning pipelines that aim to minimize the misfit between model predictions and clinical data such as the 12 lead electrocardiogram (ECG). We thus develop an automated two stage approach for HPS personalization. A fascicular-based model is first introduced that modulates the endocardial Purkinje network. Only emergent features of sites of earliest activation within the ventricular myocardium and a fast-conducting sub-endocardial layer are accounted for. It is then replaced by a topologically realistic Purkinje-based representation of the HPS. Feasibility of the approach is demonstrated. Equivalence between both HPS model representations is investigated by comparing activation patterns and 12 lead ECGs under both sinus rhythm and right-ventricular apical pacing. Predominant ECG morphology is preserved by both HPS models under sinus conditions, but elucidates differences during pacing.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Modelos Cardiovasculares , Medicina de Precisión , Algoritmos , Fascículo Atrioventricular/fisiopatología , Electrocardiografía , Humanos , Imagen por Resonancia Magnética , Ramos Subendocárdicos/fisiopatología
17.
J Cardiovasc Electrophysiol ; 32(8): 2329-2332, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34164865

RESUMEN

Parallel connection of an electrophysiology recording system (EP system) to equipment for conduction system pacing (CSP) has been widely used for fine monitoring of intracardiac electrograms and pacing evaluation. We experienced a case showing unexpected pacing threshold exacerbation under specific conditions when the EP system was connected in parallel. We evaluated the underlying mechanism using an ex vivo model. An ex vivo pacing and intracardiac electrogram monitoring model was generated using an oscilloscope, pacing system analyzer (PSA), EP system, and simulated heart. The discrepancy between expected output at the PSA and the actual measured output value at the simulated heart was measured under various conditions and using various combinations of pacing equipment. Parallel connection of the EP system was associated with reduced electrical output from the PSA as recorded at the simulated heart. The unexpected adverse effects were particularly noticeable when using an RMC-5000 EP system with the pacing function on. The trouble is completely resolved by simply turning off the pacing function of the system. There is a possibility that the EP system might increase the pacing threshold in CSP when the PSA and EP system is are deployed in parallel. The issue may provoke pseudo failure of CSP due to the high pacing threshold. When the RMC-5000 is used for conduction system pacing in parallel with a PSA for the pacing test, the pacing function of RMC-5000 should be turned off.


Asunto(s)
Fascículo Atrioventricular , Técnicas Electrofisiológicas Cardíacas , Estimulación Cardíaca Artificial , Electrocardiografía , Sistema de Conducción Cardíaco , Humanos
19.
Am J Case Rep ; 22: e929353, 2021 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-33839732

RESUMEN

BACKGROUND Bundle branch reentrant ventricular tachycardia (BBRVT) is a rarely encountered ventricular tachycardia (VT) and is classically associated with advanced heart diseases. Importantly, the tachycardia is readily curable with catheter ablation. Without suspicion of BBRVT and recording of the His-Purkinje system, it is hard to diagnose accurately. Myotonic dystrophy (MD) is the most common neuromuscular disease in adults and is known to have a risk of development of BBRVT. Here, we report a case of BBRVT in an MD patient with normal cardiac configuration with typical clinical and electrophysiological features. CASE REPORT A 40-year-old man presented with chest discomfort and weakness at the Emergency Department with unstable vital conditions. Electrocardiography showed wide QRS tachycardia with right bundle branch block pattern. The patient had been diagnosed with MD (type I) 3 years ago and had typical clinical features of MD. Transthoracic echocardiography showed normal left ventricular systolic function and no significant structural abnormalities. In the electrophysiologic study, VTs with left and right bundle branch block pattern were induced and diagnosed with BBRVT. Considering the risk of sudden death, implantation of an implantable cardioverter-defibrillator (ICD) was performed. One month later, VT had recurred and was successfully treated with ablation of the right bundle branch. CONCLUSIONS We present a case of 2 different morphologies of BBRVT in a patient with MD and normal ventricular function. Catheter ablation is a curative method for BBRVT and can be a tool for reducing ICD shock.


Asunto(s)
Ablación por Catéter , Distrofia Miotónica , Taquicardia Ventricular , Adulto , Fascículo Atrioventricular/cirugía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Distrofia Miotónica/complicaciones , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
20.
Am J Physiol Heart Circ Physiol ; 320(1): H13-H22, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33124884

RESUMEN

His bundle pacing utilizes the His-Purkinje system to produce more physiological activation compared with traditional pacing therapies, but differences in electrical activation between pacing techniques are not yet quantified in terms of activation pattern. Furthermore, clinicians distinguish between selective and nonselective His pacing, but measurable differences in electrical activation remain to be seen. Hearts isolated from seven dogs were perfused using the Langendorff method. Electrograms were recorded using two 64-electrode basket catheters in the ventricles and a 128-electrode sock situated around the ventricles during sinus rhythm (right atrial pacing), right ventricular (RV) pacing, biventricular cardiac resynchronization therapy (biV-CRT), selective His pacing (selective capture of the His bundle), and nonselective His pacing (capture of nearby myocardium and His bundle). Activation maps were generated from these electrograms. Total activation time (TAT) was measured from the activation maps, and QRS duration was measured from a one-lead pseudo-ECG. Results showed that TAT, QRS duration, and activation sequence were most similar between sinus, selective, and nonselective His pacing. Bland-Altman analyses showed highest levels of similarity between all combinations of sinus, selective, and nonselective His pacing. RV and biV-CRT activation patterns were distinct from sinus and had significantly longer TAT and QRS duration. Cumulative activation graphs were most similar between sinus, selective, and nonselective His pacing. In conclusion, selective pacing and nonselective His bundle pacing are more similar to sinus compared with RV and biV-CRT pacing. Furthermore, selective pacing and nonselective His bundle pacing are not significantly different electrically.NEW & NOTEWORTHY Our high-density epicardial and endocardial electrical mapping study demonstrated that selective pacing and nonselective His bundle pacing are more electrically similar to sinus rhythm compared with right ventricular and biventricular cardiac resynchronization therapy pacing. Furthermore, small differences between selective and nonselective His bundle pacing, specifically a wider QRS in nonselective His pacing, do not translate into significant differences in the global activation pattern.


Asunto(s)
Potenciales de Acción , Fascículo Atrioventricular/fisiología , Estimulación Cardíaca Artificial/métodos , Frecuencia Cardíaca , Ramos Subendocárdicos/fisiología , Animales , Función del Atrio Derecho , Dispositivos de Terapia de Resincronización Cardíaca , Perros , Técnicas Electrofisiológicas Cardíacas , Preparación de Corazón Aislado , Masculino , Factores de Tiempo , Función Ventricular Izquierda , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA