Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Electrophysiol ; 31(4): 805-812, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31976602

RESUMEN

INTRODUCTION: His bundle pacing (HBP) is the most physiological pacing. The standard technique based on fluoroscopic approach might be challenging and fluoro consuming. Targeting the His guided exclusively by the electrical signals could enable a precise lead implant, thus reducing fluoroscopy time (FT) and X-ray dose, desirable both for patients and operators. The aim of the study is to evaluate the feasibility, efficacy, and safety both acutely and at 30 days of the electrogram (EGM)-guided HBP with minimal or no fluoroscopy. METHODS AND RESULTS: Between October and December 2018, 41 consecutive patients underwent EGM-guided HBP. Successful HBP was obtained in 39 (95%) patients, (30 males, 78 ± 10 years). Selective HBP (S-HBP) was achieved in 23 (59%), nonselective HBP (NS-HBP) in 16 (41%) patients. The final HBP lead position was reached in 31 (79.4%) patients without fluoroscopy, only guided by electrical signals. In eight patients a minimal fluoroscopy (mean, 8 seconds) has been required. The sheath's cutting and the slack of the lead were routinely performed under fluoroscopy. No difference was observed in FT for HBP lead placement in S-HBP and NS-HBP (mean, 8.1 ± 25 vs 7.5 ± 20 seconds, P = .8; median value 0 vs 0 seconds). No differences were observed in FT for the entire procedure, total dose area product and total procedural time in S-HBP and NS-HBP. Lead dislodgement occurred in one (2.6%) patient 1 day after the procedure. CONCLUSIONS: HBP could be performed safely and efficiently using the EGMs, with minimal or no fluoroscopy. Fluoroscopy was required during sheath removal and atrial lead placement.


Asunto(s)
Potenciales de Acción , Arritmias Cardíacas/terapia , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Marcapaso Artificial , Radiografía Intervencional , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Fascículo Atrioventricular/diagnóstico por imagen , Estimulación Cardíaca Artificial/efectos adversos , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiografía Intervencional/efectos adversos , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Europace ; 20(suppl_3): iii77-iii86, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30476054

RESUMEN

AIMS: The aim of this study was to investigate the influence of the activation sequence on voltage amplitudes by evaluating regional voltage differences during a left bundle branch block (LBBB) activation sequence vs. a normal synchronous activation sequence and by evaluating pacing-induced voltage differences. METHODS AND RESULTS: Twenty-one patients and three computer models without scar were studied. Regional voltage amplitudes were evaluated in nine LBBB patients who underwent endocardial electro-anatomic mapping (EAM). Pacing-induced voltage differences were evaluated in 12 patients who underwent epicardial EAM during intrinsic rhythm and right ventricular (RV) pacing. Three computer models customized for LBBB patients were created. Changes in voltage amplitudes after an LBBB (intrinsic), a normal synchronous, an RV pacing, and a left ventricular pacing activation sequence were assessed in the computer models. Unipolar voltage amplitudes in patients were approximately 4.5 mV (4.4-4.7 mV, ∼33%) lower in the septum when compared with other segments. A normal synchronous activation sequence in the computer models normalized voltage amplitudes in the septum. Pacing-induced differences were larger in electrograms with higher voltage amplitudes during intrinsic rhythm and furthermore larger and more variable at the epicardium [mean absolute difference: 3.6-6.2 mV, 40-53% of intrinsic value; interquartile range (IQR) differences: 53-63% of intrinsic value] compared to the endocardium (mean absolute difference: 3.3-3.8 mV, 28-30% of intrinsic value; IQR differences: 37-40% of intrinsic value). CONCLUSION: In patients and computer models without scar, lower septal unipolar voltage amplitudes are exclusively associated with an LBBB activation sequence. Pacing substantially affects voltage amplitudes, particularly at the epicardium.


Asunto(s)
Potenciales de Acción , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Simulación por Computador , Frecuencia Cardíaca , Modelos Cardiovasculares , Adulto , Anciano , Anciano de 80 o más Años , Fascículo Atrioventricular/diagnóstico por imagen , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA