Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.271
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
3.
J Interv Card Electrophysiol ; 67(2): 303-317, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37354370

RESUMEN

BACKGROUND: Real-time phase mapping (ExTRa™) is useful in determining the strategy of catheter ablation for non-paroxysmal atrial fibrillation (AF). This study aimed to investigate the features of drivers of AF associated with its termination during ablation. METHODS: Thirty-six patients who underwent catheter ablation for non-paroxysmal AF using online real-time phase mapping (ExTRa™) were enrolled. A significant AF driver was defined as an area with a non-passively activated ratio of ≥ 50% on mapping analysis in the left atrium (LA). All drivers were simultaneously evaluated using a low-voltage area, complex fractionated atrial electrogram (CFAE), and rotational activity by unipolar electrogram analysis. The electrical characteristics of drivers were compared between patients with and without AF termination during the procedure. RESULTS: Twelve patients achieved AF termination during the procedure. The total number of drivers detected on the mapping was significantly lower (4.4 ± 1.6 vs. 7.4 ± 3.8, p = 0.007), and the drivers were more concentrated in limited LA regions (2.8 ± 0.9 vs. 3.9 ± 1.4, p = 0.009) in the termination group than in the non-termination group. The presence of drivers 2-6 with limited (≤ 3) LA regions showed a tenfold increase in the likelihood of AF termination, with 83% specificity and 67% sensitivity. Among 231 AF drivers, the drivers related to termination exhibited a greater overlap of CFAE (56.8 ± 34.1% vs. 39.5 ± 30.4%, p = 0.004) than the non-related drivers. The termination group showed a trend toward a lower recurrence rate after ablation (p = 0.163). CONCLUSIONS: Rotors responsible for AF maintenance may be characterized in cases with concentrated regions and fewer drivers on mapping.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Resultado del Tratamiento
5.
Pacing Clin Electrophysiol ; 47(1): 28-35, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38029377

RESUMEN

BACKGROUND: Recently, a new OCTARAY® mapping catheter was commercially launched. The catheter is designed to enable high-density mapping and precise signal recording via 48 small electrodes arranged on eight radiating splines. The purpose of this study was to compare bipolar voltage and low-voltage-area size, and mapping efficacy between the OCTARAY catheter and the PENTARAY® catheter METHODS: Twelve consecutive patients who underwent initial and second ablations for persistent atrial fibrillation within 2 years were considered for enrollment. Voltage mapping was performed twice, first during the initial ablation using the PENTARY catheter and second during the second ablation using the OCTARAY Long 3-3-3-3-3 (L3) catheter. RESULTS: Mean voltage with the OCTARAY-L3 catheter (1.64 ± 0.57 mV) was 32.3% greater than that with the PENTARAY catheter (1.24 ± 0.46 mV, p < .0001) in total left atrium. Low-voltage-area (<0.50 mV) size with the OCTARAY-L3 catheter was smaller than that with the PENTARAY catheter (6.9 ± 9.7 vs. 11.4 ± 13.0 cm2 , p < .0001). The OCTARAY-L3 catheter demonstrated greater efficacy than the PENTARAY catheter in terms of shorter mapping time (606 ± 99 vs. 782 ± 211 s, p = .008) and more mapping points (3,026 ± 838 vs. 781 ± 342 points, p < .0001). CONCLUSION: The OCTARAY catheter demonstrated higher voltage recordings, narrower low-voltage areas, and a more efficacious mapping procedure than the PENTARAY catheter.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Técnicas Electrofisiológicas Cardíacas , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Catéteres
6.
J Cardiothorac Vasc Anesth ; 38(1): 148-154, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37953172

RESUMEN

OBJECTIVES: The authors report their experience of a protocol for deep sedation with ketamine in spontaneous respiration during the pulsed-field ablation (PFA) of atrial fibrillation (AF). DESIGN: Observational, prospective, nonrandomized fashion. SETTING: Single-center hospitalized patients. PARTICIPANTS: All consecutive patients undergoing PFA of AF. INTERVENTIONS: Patients undergoing deep sedation with intravenous ketamine. MEASUREMENTS AND MAIN RESULTS: The authors' sedation protocol involves the intravenous administration of fentanyl (1.5 µg/kg) and midazolam (2 mg) at low doses before local anesthesia with lidocaine. A ketamine adjunct (1 mg/kg) in 5-minute boluses was injected about 5 minutes before the first PFA delivery. The authors enrolled 117 patients (age = 59 ± 10 y, 74.4% males, body mass index = 27.6 ± 5 kg/m2, fluoroscopy time = 24 ± 14 minutes, skin-to-skin time = 80 ± 40 minutes and PFA LA dwell time = 24 ± 7 minutes). By the end of the procedure, pulmonary vein isolation had been achieved in all patients using PFA alone. The mean time under sedation was 54.9 ± 6 minutes, with 92 patients (79%) being sedated for <1 hour. A satisfactory Ramsay Sedation Scale level before ketamine administration was achieved in all patients, except one (80.3% of the patients with rank 3; 18.4% with rank 2). In all procedures, the satisfaction level was found acceptable by both the patient and the primary operator (satisfactory in 98.2% of cases). All patients achieved a Numeric Rating Scale for Pain ≤3 (none or mild). No major procedure or anesthesia-related complications were reported. CONCLUSION: The authors' standardized sedation protocol with the administration of drugs with rapid onset and pharmacologic offset at low doses was safe and effective, with an optimal degree of patient and operator satisfaction.


Asunto(s)
Fibrilación Atrial , Sedación Profunda , Ketamina , Propofol , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Estudios Prospectivos , Administración Intravenosa , Anestesia Local , Fibrilación Atrial/cirugía , Respiración
7.
J Cardiovasc Electrophysiol ; 35(2): 328-340, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38105441

RESUMEN

INTRODUCTION: The aim of the current study was to elucidated the reliable atrial fibrillation (AF) drivers identified by CARTOFINDER using OctaRay catheter. METHODS AND RESULTS: The reliability of focal and rotational activations identified by CARTOFINDER using OctaRay catheter was assessed by the sequential recordings in each site of both atrium before and after pulmonary vein isolation (PVI) in 10 persistent AF patients. The outcome measures were the reproducibility rate during the sequential recordings and the stability rate between pre- and post-PVI as reliable focal and rotational activations. The study results were compared with those under use of PentaRay catheter (N = 18). Total 68928 points of 360 sites in OctaRay group and 24 177 points of 311 sites in PentaRay were assessed. More focal activation sites were identified in OctaRay group than PentaRay group (7.9% vs. 5.7%, p < .001), although the reproducibility rate and the stability rate were significantly lower in OctaRay group (45.3% vs. 58.9%, p < .001; 11.2% vs. 28.4%, p < .001). Meanwhile, the prevalence of reproducible focal activation sites among overall points was comparable (3.6% vs. 3.3%, p = .08). Regarding rotational activation, more rotational activation sites were identified in OctaRay group (5.1% vs. 0.2%, p < .001), and the reproducibility rate and the stability rate were significantly higher in OctaRay group (45.2% and 12.5% vs. 0.0%, p < .001). Both reliable focal and rotational activation sites were characterized by significantly shorter AF-cycle length (CL) and higher repetition of focal and rotational activations during the recordings compared with the sites of non or unreliable focal and rotational activations. CONCLUSION: In CARTOFINDER, OctaRay catheter could identify reliable focal activation with high resolution and reliable rotational activation compared with PentaRay catheter. The repetitive focal and rotational activations with short AF-CL could be the potential target during ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Frecuencia Cardíaca , Reproducibilidad de los Resultados , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Catéteres , Venas Pulmonares/cirugía , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 46(11): 1357-1365, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37910563

RESUMEN

Mapping and ablation of atrial tachycardia (AT) in patients who have had prior cardiac surgery can be a challenge for clinical electrophysiologists. High density mapping (HDM) technology has been widely used in these patients because it provides a better characterization of the substrate and the mechanisms with an unprecedented high resolution. In this review, we summarize how the latest HDM technologies can reveal the mechanism of AT in different types of patients post-cardiac surgery and guide a specifically tailored ablation strategy.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Taquicardia Supraventricular , Humanos , Técnicas Electrofisiológicas Cardíacas , Ablación por Catéter/efectos adversos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Taquicardia Supraventricular/etiología , Corazón , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento , Fibrilación Atrial/cirugía
9.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37961921

RESUMEN

AIMS: The aim of our study was to analyse the response to short-coupled atrial extrastimuli to identify areas of hidden slow conduction (HSC) and their relationship with the atrial fibrillation (AF) phenotype. METHODS AND RESULTS: Twenty consecutive patients with paroxysmal AF and persistent AF (10:10) underwent the first pulmonary vein isolation procedure. Triple short-coupled extrastimuli were delivered in sinus rhythm (SR), and the evoked response was analysed: sites exhibiting double or highly fragmented electrograms (EGM) were defined as positive for HSC (HSC+). The delta of the duration of the bipolar EGM was analysed, and bipolar EGM duration maps were built. High-density maps were acquired using a multipolar catheter during AF, SR, and paced rhythm. Spatial co-localization of HSC+ and complex fractionated atrial EGMs (CFAE) during AF was evaluated. Persistent AF showed a higher number and percentage of HSC+ than paroxysmal AF (13.9% vs. 3.3%, P < 0.001). The delta of EGM duration was 53 ± 22 ms for HSC+ compared with 13 ± 11 (10) ms in sites with negative HSC (HSC-) (P < 0.001). The number and density of HSC+ were lower than CFAE during AF (19 vs. 56 per map, P < 0.001). The reproducibility and distribution of HSC+ in repeated maps were superior to CFAE (P = 0.19 vs. P < 0.001). Sites with negative and positive responses showed a similar bipolar voltage in the preceding sinus beat (1.65 ± 1.34 and 1.48 ± 1.47 mV, P = 0.12). CONCLUSION: Functional mapping identifies more discrete and reproducible abnormal substrates than mapping during AF. The HSC+ sites in response to triple extrastimuli are more frequent in persistent AF than in paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Reproducibilidad de los Resultados , Técnicas Electrofisiológicas Cardíacas/métodos , Frecuencia Cardíaca , Atrios Cardíacos
10.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37470443

RESUMEN

AIMS: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. METHODS AND RESULTS: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1-1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (<0.5 mV) >28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08-11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34-13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. CONCLUSION: Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Frecuencia Cardíaca , Resultado del Tratamiento , Técnicas Electrofisiológicas Cardíacas , Recurrencia , Factores de Tiempo , Atrios Cardíacos , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
11.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1082-1096, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37495319

RESUMEN

BACKGROUND: Dominant frequencies (DFs) or complex fractionated atrial electrograms (CFAEs), indicative of focal sources or rotational activation, are used to identify target sites for atrial fibrillation (AF) ablation in clinical studies, although the relationship among DF, CFAE, and activation patterns remains unclear. OBJECTIVES: This study sought to investigate the relationship between patterns of activation underlying DF and CFAE sites during AF. METHODS: Epicardial high-resolution mapping of the right and left atrium including Bachmann's bundle was performed in 71 participants. We identified the highest dominant frequency (DFmax) and highest degree of CFAE (CFAEmax) with the use of existing clinical criteria and classified patterns of activation as focal or rotational activation and smooth propagation, conduction block (CB), collision and remnant activity, and fibrillation potentials as single, double, or fractionated potentials containing, respectively, 1, 2, or 3 or more negative deflections. Relationships among activation patterns, DFmax, and potential types were investigated. RESULTS: DFmax were primarily located at the left atrioventricular groove and did not harbor focal activation (proportion focal waves: 0% [IQR: 0%-2%]). Compared with non-DFmax sites, DFmax were characterized by more frequent smooth propagation (22% [IQR: 7%-48%] vs 17% [IQR: 11%-24%]; P = 0.001), less frequent conduction block (69% [IQR: 51%-81%] vs 74% [IQR: 69%-78%]; P = 0.006), a higher proportion of single potentials (72% [IQR: 55%-84%] vs 6%1 [IQR: 55%-65%]; P = 0.003), and a lower proportion of fractionated potentials (4% [IQR: 1%-11%] vs 12% [IQR: 9%-15%]; P = 0.004). CFAEmax were mainly found at the pulmonary veins area, and only 1% [IQR: 0%-2%] of all CFAEmax contained focal activation. Compared with non-CFAEmax sites, CFAEmax sites were characterized by less frequent smooth propagation (1% [IQR: 0%-1%] vs 17% [IQR: 12%-24%]; P < 0.001) and more frequent remnant activity (20% [IQR: 12%-29%] vs 8% [IQR: 5%-10%]; P < 0.001), and harbored predominantly fractionated potentials (52% [IQR: 43%-66%] vs 12% [IQR: 9%-14%]; P < 0.001). CONCLUSIONS: Focal or rotational patterns of activation were not consistently detected at DFmax domains and CFAEmax sites. These findings do not support the concept of targeting DFmax or CFAEmax according to existing criteria for AF ablation.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Técnicas Electrofisiológicas Cardíacas , Mapeo Epicárdico , Nodo Atrioventricular , Bloqueo Cardíaco
12.
Altern Ther Health Med ; 29(7): 160-165, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37442191

RESUMEN

Objective: This study aimed to analyze the clinical significance of body mass index (BMI), mean platelet volume (MPV), and left atrial structure in the recurrence of atrial fibrillation (AF) after treatment with catheter radiofrequency ablation. Methods: A total of 69 patients with AF who underwent catheter radiofrequency ablation at Beijing Anzhen Hospital from January 2020 to July 2021 (research group) were compared to 75 patients who underwent physical examination during the same period (control group). MPV levels were measured before and after treatment in both groups. Additionally, height and weight measurements were used to calculate BMI, while left atrial anteroposterior diameter, left atrial volume, and left atrial volume index were recorded using cardiac ultrasonography. Results: The research group exhibited higher BMI, MPV, left atrial anteroposterior diameter, left atrial volume, and left atrial volume index compared to the control group, and these parameters decreased after treatment (P < .05). Prognostic follow-up revealed that patients with AF recurrence had higher values for these parameters than those without recurrence (P < .05). Receiver Operating Characteristic analysis indicated that all these parameters had good predictive value for prognostic recurrence of AF (P < .05). Logistic regression analysis demonstrated that all the parameters were independent risk factors for prognostic atrial fibrillation recurrence (P < .05). Conclusions: BMI, MPV, and left atrial structure are associated with the occurrence and development of atrial fibrillation. These parameters provide an excellent assessment of the prognosis for AF recurrence after catheter radiofrequency ablation treatment. Monitoring changes in BMI, MPV, and left atrial structure in atrial fibrillation patients can contribute to more reliable prognostic information in clinical settings.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Índice de Masa Corporal , Volúmen Plaquetario Medio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Recurrencia , Resultado del Tratamiento
13.
Eur Heart J ; 44(35): 3339-3353, 2023 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-37350738

RESUMEN

BACKGROUND AND AIMS: This study aimed to histologically validate atrial structural remodelling associated with atrial fibrillation. METHODS AND RESULTS: Patients undergoing atrial fibrillation ablation and endomyocardial atrial biopsy were included (n = 230; 67 ± 12 years old; 69 women). Electroanatomic mapping was performed during right atrial pacing. Voltage at the biopsy site (Vbiopsy), global left atrial voltage (VGLA), and the proportion of points with fractionated electrograms defined as ≥5 deflections in each electrogram (%Fractionated EGM) were evaluated. SCZtotal was calculated as the total width of slow conduction zones, defined as regions with a conduction velocity of <30 cm/s. Histological factors potentially associated with electroanatomic characteristics were evaluated using multiple linear regression analyses. Ultrastructural features and immune cell infiltration were evaluated by electron microscopy and immunohistochemical staining in 33 and 60 patients, respectively. Fibrosis, intercellular space, myofibrillar loss, and myocardial nuclear density were significantly associated with Vbiopsy (P = .014, P < .001, P < .001, and P = .002, respectively) and VGLA (P = .010, P < .001, P = .001, and P < .001, respectively). The intercellular space was associated with the %Fractionated EGM (P = .001). Fibrosis, intercellular space, and myofibrillar loss were associated with SCZtotal (P = .028, P < .001, and P = .015, respectively). Electron microscopy confirmed plasma components and immature collagen fibrils in the increased intercellular space and myofilament lysis in cardiomyocytes, depending on myofibrillar loss. Among the histological factors, the severity of myofibrillar loss was associated with an increase in macrophage infiltration. CONCLUSION: Histological correlates of atrial structural remodelling were fibrosis, increased intercellular space, myofibrillar loss, and decreased nuclear density. Each histological component was defined using electron microscopy and immunohistochemistry studies.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos , Frecuencia Cardíaca , Fibrosis
14.
J Cardiovasc Electrophysiol ; 34(8): 1613-1621, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37365931

RESUMEN

INTRODUCTION: Improved sinus rhythm (SR) maintenance rates have been achieved in patients with persistent atrial fibrillation (AF) undergoing pulmonary vein isolation plus additional ablation of low voltage substrate (LVS) during SR. However, voltage mapping during SR may be hindered in persistent and long-persistent AF patients by immediate AF recurrence after electrical cardioversion. We assess correlations between LVS extent and location during SR and AF, aiming to identify regional voltage thresholds for rhythm-independent delineation/detection of LVS areas. (1) Identification of voltage dissimilarities between mapping in SR and AF. (2) Identification of regional voltage thresholds that improve cross-rhythm substrate detection. (3) Comparison of LVS between SR and native versus induced AF. METHODS: Forty-one ablation-naive persistent AF patients underwent high-definition (1 mm electrodes; >1200 left atrial (LA) mapping sites per rhythm) voltage mapping in SR and AF. Global and regional voltage thresholds in AF were identified which best match LVS < 0.5 mV and <1.0 mV in SR. Additionally, the correlation between SR-LVS with induced versus native AF-LVS was assessed. RESULTS: Substantial voltage differences (median: 0.52, interquartile range: 0.33-0.69, maximum: 1.19 mV) with a predominance of the posterior/inferior LA wall exist between the rhythms. An AF threshold of 0.34 mV for the entire left atrium provides an accuracy, sensitivity and specificity of 69%, 67%, and 69% to identify SR-LVS < 0.5 mV, respectively. Lower thresholds for the posterior wall (0.27 mV) and inferior wall (0.3 mV) result in higher spatial concordance to SR-LVS (4% and 7% increase). Concordance with SR-LVS was higher for induced AF compared to native AF (area under the curve[AUC]: 0.80 vs. 0.73). AF-LVS < 0.5 mV corresponds to SR-LVS < 0.97 mV (AUC: 0.73). CONCLUSION: Although the proposed region-specific voltage thresholds during AF improve the consistency of LVS identification as determined during SR, the concordance in LVS between SR and AF remains moderate, with larger LVS detection during AF. Voltage-based substrate ablation should preferentially be performed during SR to limit the amount of ablated atrial myocardium.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/cirugía
15.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37050858

RESUMEN

AIMS: The optimal strategy for persistent atrial fibrillation (PerAF) is poorly defined. We conducted a multicentre, randomized, prospective trial to compare the outcomes of different ablation strategies for PerAF. METHODS AND RESULTS: We enrolled 450 patients and randomly assigned them in a 1:1:1 ratio to undergo pulmonary vein isolation and subsequently undergo the following three different ablation strategies: anatomical guided ablation (ANAT group, n = 150), electrogram guided ablation (EGM group, n = 150), and extensive electro-anatomical guided ablation (EXT group, n = 150). The primary endpoint was freedom from atrial fibrillation (AF) lasting longer than 30 s at 12 months after a single ablation procedure. After 12 months of follow-up, 72% (108) of patients in the EXT group were free from AF recurrence, as compared with the 64% (96) in the EGM group (P = 0.116), and 54% (81) in the ANAT group (P = 0.002). The EXT group showed less AF/atrial tachycardia recurrence than the EGM group (60% vs. 50%, P = 0.064) and the ANAT group (60% vs. 37.3%, P < 0.001). The EXT group showed the highest rate of AF termination (66.7%), followed by 56.7% in the EGM group, and 20.7% in the ANAT group. The AF termination signified less AF recurrence at 12 months compared to patients without AF termination (30.1% vs. 42.7%, P = 0.008). Safety endpoints did not differ significantly between the three groups (P = 0.924). CONCLUSIONS: Electro-anatomical guided ablation achieved the most favourable outcomes among the three ablation strategies. The AF termination is a reliable ablation endpoint.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Venas Pulmonares/cirugía , Recurrencia
16.
J Interv Card Electrophysiol ; 66(9): 2047-2054, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37014482

RESUMEN

BACKGROUND: Superimposition of farfield (FF) and nearfield (NF) bipolar voltage electrograms (BVE) complicates the confirmation of pulmonary vein (PV) isolation after catheter ablation of atrial fibrillation. Our aim was to develop an automatic algorithm based on a single-beat analysis to discriminate PV NF from atrial FF BVE from a circular mapping catheter during the cryoballoon PV isolation. METHODS: During freezing cycles in cryoablation PVI, local NF and distant FF signals were recorded, identified and labelled. BVEs were classified using four different machine learning algorithms based on four frequency domain (high-frequency power (PHF), low-frequency power (PLF), relative high power band, PHF ratio of neighbouring electrodes) and two time domain features (amplitude (Vmax), slew rate). The algorithm-based classification was compared to the true identification gained during the PVI and to a classification by cardiac electrophysiologists. RESULTS: We included 335 BVEs from 57 consecutive patients. Using a single feature, PHF with a cut-off at 150 Hz showed the best overall accuracy for classification (79.4%). By combining PHF with Vmax, overall accuracy was improved to 82.7% with a specificity of 89% and a sensitivity of 77%. The overall accuracy was highest for the right inferior PV (96.6%) and lowest for the left superior PV (76.9%). The algorithm showed comparable accuracy to the classification by the EP specialists. CONCLUSIONS: An automated farfield-nearfield discrimination based on two simple features from a single-beat BVE is feasible with a high specificity and comparable accuracy to the assessment by experienced cardiac electrophysiologists.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Electrocardiografía , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Algoritmos , Resultado del Tratamiento
17.
J Cardiovasc Electrophysiol ; 34(5): 1130-1140, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37102590

RESUMEN

INTRODUCTION: Various adjunctive approaches to pulmonary vein isolation (PVI) have been attempted for persistent atrial fibrillation (perAF) and longstanding persistent AF (ls-perAF). We aimed to identify the novel zones responsible for perpetuation of AF. METHODS: To identify novel zones acting as a source of perAF and ls-perAF after PVI/re-PVI, we performed fractionation mapping in 258 consecutive patients with perAF (n = 207) and ls-perAF (n = 51) in whom PVI/re-PVI failed to restore sinus rhythm. RESULTS: In 15 patients with perAF (5.8%: 15/258), fractionation mapping identified a small solitary zone (<1 cm2 ) with high-frequency and irregular waves, showing fractionated electrograms (EGM). We defined this zone as the small solitary atrial fractionated EGM (SAFE) zone. The small SAFE zone was surrounded characteristically by a homogeneous area showing relatively organized activation with nonrapid and nonfractionated waves. Only one small SAFE zone was detected in each patient. This characteristic electrical phenomenon was observed stably during the procedure until ablation. AF duration, (defined as the duration between initial detection of AF and the current ablation) was longer in patients with the small SAFE zone than in those without (median, [25 and 75 percentiles]; 5.0 [3.5, 7.0] vs. 1.1 [1.0, 4.0] years, p = .0008). Longer AF cycle length was observed in patients with the small SAFE zone than in those without. The ablation of the small SAFE zone terminated AF in all 15 patients without any need for other ablations. AF/atrial tachycardia-free rate at follow-up was 93% (14/15) at 6 months, 87% (13/15) at 1 year, and 60% (9/15) at 2 years. CONCLUSIONS: Using fractionation mapping, this study identified a small SAFE zone surrounded characteristically by a homogeneous, relatively organized, low-excitability EGM lesion. The ablation of the small SAFE zone terminated AF in all patients, demonstrating it as a substrate for perpetuated AF. Our findings provide novel ablation targets in perAF patients with prolonged AF duration. Further studies to confirm the present results are warranted.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Venas Pulmonares/cirugía , Recurrencia
18.
Clin Res Cardiol ; 112(6): 716-723, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37000245

RESUMEN

Progression of atrial fibrillation (AF) and outcomes of ablation therapy are strongly affected by modifiable risk factors. Although previous studies show beneficial effects of modifying single risk factors, there is lack of evidence from randomized controlled trials on the effects of integrated AF lifestyle programmes. The POP trial is designed to evaluate the clinical outcomes of a dedicated nurse-led AF lifestyle outpatient clinic in patients with symptomatic AF. This study is a prospective, 1:1 randomized, single centre, investigator-initiated clinical trial in 150 patients with paroxysmal or persistent AF referred for a first pulmonary vein isolation (PVI). Prior to the ablation, patients in the intervention group receive a personalized risk factor treatment programme in a specialized, protocolized, nurse-led outpatient clinic. Patient education and durable lifestyle management is promoted with an e-health platform. Patients in the control group receive standard care by cardiologists before ablation. The primary endpoint is the number of hospitalizations for re-ablation and cardioversion, with a follow-up of 12 months after ablation. Secondary endpoints include mortality, number of acute ischemic events, stroke or hospitalizations for heart failure, quality of life, number of ablations cancelled because of symptom reduction, and ablation success rate at 12 months. Determinants of patient and staff experience are explored and a cost-effectiveness analysis is included. The POP trial will help ascertain the efficacy and cost-effectiveness of an integrated technology-supported lifestyle therapy in patients with symptomatic AF. The trial is funded by the Netherlands Organisation for Health Research and Development [10070012010001]. Home sleep apnoea testing devices were provided by Itamar Medical, Ltd.ClinicalTrials.gov Identifier NCT05148338. AF atrial fibrillation, OSA obstructive sleep apnoea, PFA pulsed field ablation, PVI pulmonary vein isolation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Estilo de Vida , Estudios Prospectivos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Resultado del Tratamiento
19.
J Interv Card Electrophysiol ; 66(5): 1291-1301, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36725820

RESUMEN

Catheter ablation is an important therapeutic strategy for patients with atrial fibrillation (AF). While some critical steps of the procedure have traditionally relied on fluoroscopy, advances in electroanatomic mapping and the growing use of intracardiac echocardiography have made non-fluoroscopic AF ablation a reality. This hands-on review provides an overview on how to perform radiofrequency ablation of AF without the use of fluoroscopy, focusing on technical aspects, new technologies, and troubleshooting.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Flujo de Trabajo , Resultado del Tratamiento , Técnicas Electrofisiológicas Cardíacas , Ablación por Catéter/métodos , Fluoroscopía
20.
JACC Clin Electrophysiol ; 9(4): 526-540, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36669899

RESUMEN

BACKGROUND: Electrogram (EGM) morphology recurrence (EMR) mapping of persistent atrial fibrillation (AF) quantifies consistency of activation and is expected to be high and rapid near AF drivers. OBJECTIVES: The purpose of this study was to compare EMR in left atria (LA) and right atria (RA) in patients undergoing first vs redo ablation for persistent AF. METHODS: Multisite LA/RA mapping (LA: 281 ± 176 sites/patient; RA: 239 ± 166 sites/patient) before persistent AF ablation was performed in 42 patients (30 males, age 63 ± 9 years) undergoing first (Group 1, n = 32) or redo ablation (Group 2, n = 10). After cross-correlation of each automatically detected EGM with every other EGM per recording, the most recurrent electrogram morphology was identified and its frequency (Rec%) and recurrence cycle length (CLR) were computed. RESULTS: In Groups 1 and 2, minimum CLR was 172.8 ± 26.0 milliseconds (LA: 178.2 ± 37.6 milliseconds, RA: 204.4 ± 34.0 milliseconds, P = 0.0005) and 186.5 ± 28.3 milliseconds (LA: 196.1 ± 38.1 milliseconds vs RA: 199.0 ± 30.2 milliseconds, P = 0.75), with Rec% 94.7% ± 10% and 93.8% ± 9.2%. Group 2 minimum CLR was not different from Group 1 (P = 0.20). Shortest CLR was in the LA in 84% of Group 1 and 50% of Group 2 patients (P = 0.04). Only 1 of 10 patients in Group 2 had the shortest CLR in the pulmonary veins (PVs) compared with 19 of 32 in Group 1 (P = 0.01). Most sites (77.6%) had Rec% <50%. CONCLUSIONS: EMR identified the shortest CLR sites in the PVs in 59% of patients undergoing initial persistent AF ablation, consistent with reported success rates of ∼50% for PV isolation. The majority of sites have low recurrence and may reflect bystander sites not critical for maintaining AF. EMR provides a robust new method for quantifying consistency and rapidity of activation direction at multiple atrial sites.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Masculino , Humanos , Persona de Mediana Edad , Anciano , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Apéndice Atrial/cirugía , Ablación por Catéter/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA