Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Thorac Cardiovasc Surg ; 69(5): 461-465, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33075824

RESUMEN

As part of an institutionally driven holistic concept, named the "360-degree approach," all established surgical access routes -full sternotomy, partial upper sternotomy, and right anterolateral thoracotomy using the second interspace-are supported. The surgical toolbox now is completed by adding a further approach: through a 5- to7-cm skin incision in the right anterior axillary line, the third interspace is used for a minimally invasive aortic valve surgery providing striking exposition of the aortic valve and resulting in superior cosmetics with nearly no visible scars. The choice for the one or other method is institutionally driven and based on risk profiles, as well as anatomical and physiognomic considerations.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cicatriz/prevención & control , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Cicatriz/etiología , Toma de Decisiones Clínicas , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Selección de Paciente , Resultado del Tratamiento
2.
Pak J Biol Sci ; 23(11): 1487-1491, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33274879

RESUMEN

BACKGROUND AND OBJECTIVE: Khat is a plant that contains the alkaloids cathine and cathinone which have some amphetamine-like properties. It is cultivated and it's leaves chewed for their euphoric effect. This study intended to elucidate the effect of khat chewing on blood coagulation by using the International Normalized Ratio (INR) value as a calculable benchmark. MATERIALS AND METHODS: In this cohort study, 146 patients with Mechanical Heart Valves (MHV) were assessed for two consecutive visits at one-month intervals. For each visit, the date of surgery, the patient's compliance, the dose of warfarin and the INR reading were assessed by the researcher. RESULTS: Out of 146 patients with MHV, the mean age was 33.72±12.43 years (range, 14-65 years); 82 (56.2%) were female and 64 (43.8%) were male. The results revealed that the mean of absolute INR readings was lower in khat-chewers than non-chewers by average 0.2 on the first and second visits (p = 0.038 and 0.002, respectively). CONCLUSION: Khat chewing has a significant coagulant effect. There was a significant decrease in the value of INR for khat chewers patients with MHV when compared to non-khat chewers.


Asunto(s)
Anticoagulantes/uso terapéutico , Coagulación Sanguínea/efectos de los fármacos , Catha/efectos adversos , Monitoreo de Drogas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Relación Normalizada Internacional , Warfarina/uso terapéutico , Adolescente , Adulto , Anciano , Anticoagulantes/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Interacciones de Hierba-Droga , Humanos , Masculino , Masticación , Persona de Mediana Edad , Hojas de la Planta/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Warfarina/efectos adversos , Adulto Joven
4.
Asian Cardiovasc Thorac Ann ; 28(7): 366-370, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32436717

RESUMEN

Rheumatic mitral valve disease remains a challenge for cardiac surgeons. Valve repair has several advantages over valve replacement but is technically demanding for good results. To improve rheumatic mitral valve repair, surgeons need to have a deep understand of the mitral valve complex and its dynamics. The goal of repair is to restore normal diastolic and systolic function. The current approach is to perform a holistic repair of the entire mitral complex. Each part of the complex is thoroughly explored to define the problem. Several innovative techniques have been introduced to correct valve dysfunction and provide gratifying results. The details of these techniques will be described, based on an understanding of the relationship of the mitral valve complex and dynamics. With this approach, rheumatic mitral valve repair is becoming more successful, reproducible, and safe. Long-term follow-up is mandatory.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Cardiopatía Reumática/cirugía , Válvula Aórtica/fisiopatología , Fibrilación Atrial/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemodinámica , Humanos , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/fisiopatología , Recuperación de la Función , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/fisiopatología , Resultado del Tratamiento , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/fisiopatología
5.
J Am Heart Assoc ; 9(7): e014874, 2020 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-32248763

RESUMEN

Background There has been uncertainty regarding the effect of transcatheter mitral valve repair (TMVr) with MitraClip on cardiac surgical practice. Our aim was to examine the impact of the commercial introduction of TMVr to a comprehensive mitral program. Methods and Results We evaluated 875 patients (aged 69±14 years; 58% men) who underwent transcatheter or mitral surgical procedures over a 6-year period at our institution. Main outcomes were changes in surgical procedural volume after TMVr introduction and short-term mortality for surgical and TMVr procedures. The numbers of patients treated with MitraClip, isolated mitral repair, and any mitral surgery were 249, 292, and 626 patients, respectively. Compared with surgery, patients with MitraClip were older (aged 82±8 versus 64±12 years; P<0.001) and had more severe morbidity. Following the introduction of MitraClip, surgical volumes steadily increased to a rate of 10 (95% CI, 3-7) procedures per year for isolated mitral procedures and 17 (95% CI, 13-20) procedures per year for all mitral surgeries. Both MitraClip and surgical volumes increased at the same rate (P=0.42). In-hospital mortality was 3.2% for MitraClip and 2.1% for all mitral surgeries (P=0.33). At 30 days, survival free of all mortality (P=0.17) and freedom from heart failure rehospitalization (P=0.75) were similar for transcatheter and surgical procedures. Conclusions The commercial introduction of TMVr may be associated with growth in cardiac surgery, without detracting from other therapies, and favorable clinical outcomes for all treated mitral regurgitation patients. These findings demonstrate the potential benefits of complementary therapies in the treatment of patients with mitral regurgitation.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Readmisión del Paciente , Complicaciones Posoperatorias/etiología , Evaluación de Programas y Proyectos de Salud , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
6.
BMC Cardiovasc Disord ; 20(1): 104, 2020 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-32126966

RESUMEN

BACKGROUND: Intractable, mechanical hemolytic anemia (IMHA) is a rare catastrophic complication following mitral valve surgery. We analyzed patient characteristics and IMHA management by reoperations after mitral valve surgery. METHODS: We collected medical records from mitral valve patients requiring reoperation due to IMHA. INCLUSION CRITERIA: hemoglobin < 100 g/L; positive hemolysis tests and echocardiography results; and exclusion of other hemolysis causes. RESULTS: Data from 25 IMHA cases included 10 (40%) early onset (1.3 (0.3,3.0) months) and 15 (60%) late onset (120 (24,204) months) cases. Early IMHA etiologies included surgical defects (6, 60%), uncontrolled infection (3, 30%) and Bechet's disease (1, 10%). Late IMHA etiologies included degeneration (13, 87%), new infection (1, 7%) and trauma (1, 7%). There were more mechanical valves (15, 88%) than bio-valves (2, 12%); the main valvular dysfunction was paravalvular leak (16, 64%). IMHA manifestations included jaundice (18, 72%), dark urine (21, 84%), heart failure (16, 64%), acute kidney injury (11, 44%), hepatomegaly (15, 60%), splenomegaly (15, 60%) and pancreatitis (1, 4%). Laboratory results showed decreased hemoglobin (70 ± 14 g/L) and increased bilirubin (72 ± 57 µmol/L), lactate dehydrogenase (2607 ± 2142 IU/L) and creatinine (136 ± 101 µmol/L) levels. Creatinine level negatively correlated with hemoglobin level (B = -3.33, S.E. B = 1.31, Exp(B) = 368.15, P = 0.018). Preoperative medications included iron supplements (20, 80%), erythropoietin (16, 64%) and beta-blocker (22, 88%). Two patients died of cardiac causes before reoperation. The other 23 underwent reoperation with long surgical times (aortic cross clamp 124 ± 50 min, cardiopulmonary bypass 182 ± 69 min) and blood transfusions (red blood cells 6 (6, 8) units, plasma 600 (400,800) ml, platelet 1(0,2) units). Postoperative complications included cardiac dysfunction (5, 22%), arrhythmia (10, 43%), sepsis (6, 26%), pulmonary infection (5, 22%), gastrointestinal bleeding (3, 13%), cerebral hemorrhage (2, 9%), chronic renal dysfunction (1, 4%) and surgical hemorrhage (1, 4%). Five (33%) patients died after reoperation from cardiac dysfunction (3, 60%), septic shock (1, 20%) and self-discharge (1, 20%). CONCLUSIONS: IMHA induces severe multi-organ dysfunction, contributing to high mortality. Perioperative management should focus on etiological treatment, organ protection, and blood management.


Asunto(s)
Anemia Hemolítica/etiología , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemólisis , Válvula Mitral/cirugía , Adulto , Anciano , Anemia Hemolítica/diagnóstico , Anemia Hemolítica/mortalidad , Anemia Hemolítica/cirugía , Beijing , Biomarcadores/sangre , Bioprótesis , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/mortalidad , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemoglobinas/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Reoperación , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 95(1): 45-53, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31038290

RESUMEN

OBJECTIVES: To demonstrate safety, feasibility and short-term clinical outcomes after transcatheter aortic valve-in-valve (ViV) implantation under local anesthesia without contrast aortography or echocardiographic guidance. BACKGROUND: Transcatheter ViV implantation is an emerging treatment modality for patients with degenerative surgical bioprostheses. Given the radiopaque properties of the surgical aortic valve (SAV) frame, ViV procedures can often be performed with fluoroscopic guidance alone. METHODS: ViV implantation was performed in 37 patients with SAV failure under local anesthesia without contrast aortography. Clinical and echocardiographic data were obtained at baseline, discharge, and 30 days. RESULTS: Mean age was 74 ± 10 years and STS predicted risk of mortality was 5.6 ± 2.4%. Mean transaortic gradient decreased from 39.4 ± 15.5 mmHg to 13 ± 6.3 mmHg at discharge (p < .001), and 20 ± 7.5 mmHg at 30 days (p < .001 compared to baseline), aortic valve area increased from 0.9 ± 0.3 cm2 to 1.2 ± 0.4 cm2 at 30 days (p = .007). No patient had more than mild aortic regurgitation. Hospital discharge occurred at a median of 2.6 ± 4.4 days. At 30-day follow-up there were no deaths, myocardial infarctions, strokes, repeat hospital admissions for heart failure, or renal failure. One patient (2.7%) required a new pacemaker. 93% of the patients were in New York Heart Association functional class I or II. CONCLUSIONS: Transcatheter aortic ViV implantation for selected patients with degenerative surgical bioprostheses under local anesthesia without aortography or echocardiographic guidance is feasible and safe.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Anestesia Local , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
10.
Interv Cardiol Clin ; 8(3): 295-300, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31078185

RESUMEN

Mitral regurgitation is the most commonly occurring valvular heart disease in developed countries. Transcatheter mitral valve replacement (TMVR) has emerged as a novel potential therapy for patients with severe mitral valve disease who are unsuitable candidates for conventional surgery or transcatheter edge-to-edge mitral repair. TMVR with the Tendyne prosthesis has shown potential at short-term follow-up to be an effective and safe treatment alternative for high-risk patients with severe mitral valve disease.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Aleaciones , Cateterismo Cardíaco/métodos , Ensayos Clínicos como Asunto , Ecocardiografía Transesofágica/métodos , Estudios de Factibilidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/anatomía & histología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/patología , Imagen Multimodal/métodos , Ensayos Clínicos Controlados no Aleatorios como Asunto , Estudios Prospectivos , Diseño de Prótesis/tendencias , Calidad de Vida , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología
11.
Catheter Cardiovasc Interv ; 94(1): 3-26, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31002751
13.
Cardiovasc Revasc Med ; 19(5 Pt A): 536-539, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29352701

RESUMEN

Trancatheter heart valve (THV) thrombosis is effectively treated with anticoagulation but alternative therapies are required when a faster gradient reduction is needed. Open heart surgery has been rarely performed due to the high perioperative mortality and only five cases have been described so far. Here we describe a case of emergent surgical explantation for THV thrombosis after a valve-in-valve. A 67years old man underwent transcatheter aortic valve implantation for a failed surgical bioprosthesis Epic 21mm (St. Jude Medical; St. Paul, Minnesota, US). A CoreValve 23mm (Medtronic, Minneapolis, Minnesota, US) was implanted through femoral access under conscious sedation without complications. Mean transvalvular gradient was effectively reduced (33mmHg vs 16mmHg) with no more than mild residual aortic regurgitation. After 8days the patient was discharged on dual antiplatelet therapy but was readmitted to the intensive care unit for pulmonary oedema 13days later. Echocardiography showed a raised transvalvular mean gradient (mean gradient change from discharge=15mmHg) without aortic regurgitation. Heart Team decided for emergent open heart surgery for the hemodynamic instability. On direct inspection THV was well positioned inside the surgical bioprosthesis but two cusps were covered by thrombus which markedly restricted their mobility. The THV and the former surgical valve were explanted and a new larger stented bioprosthesis was implanted. Thrombosis of the THV was confirmed on microscopic examination which showed no signs of inflammation or degeneration. The patient was discharged after 1month and the 3month follow up showed stable transvalvular gradients.


Asunto(s)
Anticoagulantes/administración & dosificación , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Remoción de Dispositivos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Trombosis/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Biopsia , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Trombosis/diagnóstico por imagen , Trombosis/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 92(2): E135-E138, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-28296026

RESUMEN

The development of paravalvular leak (PVL) following surgical replacement of an aortic or mitral valve is an uncommon complication with significant morbidity and mortality. Surgical or percutaneous repair of PVL can be technically challenging. We describe the application of intracardiac echocardiography guided 3-dimensional electroanatomic mapping to facilitate PVL closure in a symptomatic patient with a previously placed bioprosthetic mitral valve. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Bioprótesis , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Técnicas Electrofisiológicas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Falla de Prótesis , Cateterismo Cardíaco/instrumentación , Ecocardiografía Doppler en Color , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Diseño de Prótesis , Resultado del Tratamiento
15.
Methodist Debakey Cardiovasc J ; 13(2): 73-75, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28740586

RESUMEN

This is a case of a 54-year-old female with a history of mechanical aortic valve replacement who presented in cardiogenic shock. Her primary care provider started her on rivaroxaban for anticoagulation therapy. An urgent transesophageal echocardiogram revealed a significant gradient and thrombosis on one leaflet of the valve that was immobile. Given that she was not a surgical candidate, she underwent thrombolysis. However, she later died due to complications from the thrombotic valve. The utility of target-specific oral anticoagulants has yet to be established in clinical practice.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Inhibidores del Factor Xa/uso terapéutico , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Rivaroxabán/uso terapéutico , Trombosis/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Resultado Fatal , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Uso Fuera de lo Indicado , Terapia Trombolítica , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Resultado del Tratamiento
16.
Artículo en Inglés | MEDLINE | ID: mdl-28630170

RESUMEN

BACKGROUND: Premature ventricular contractions originating in the left ventricle outflow tract represent a significant subgroup of patients referred for catheter ablation. Mechanical artifacts from aortic valve leaflet motion may be observed during mapping, although the incidence and characteristics have not been reported. METHODS AND RESULTS: Twenty-eight consecutive patients with left ventricle outflow tract premature ventricular contraction were included. Electric signals recorded on the ablation catheter not coincident with atrial or ventricular depolarization were analyzed on the recording system. Correlation with invasive hemodynamic aortic pressure tracings was performed. Additionally, 4 patients with mechanical aortic valves, who underwent scar-related ventricular tachycardia ablation, were analyzed to correlate the timing of the observed artifacts with native aortic valves. Aortic valve artifact was observed while mapping within the coronary cusps in 11 patients (39%; 73% men; age, 41±25 years; left ventricular ejection fraction 49±16%) with high incidence from the left coronary cusp. This artifact was consistently observed with timing coincident with the terminal portion of the T wave. The average interval between the end of the T wave and the aortic valve artifact was 19±37 ms. The duration of the aortic valve artifact was 39±8 ms with amplitude of 0.12±0.07 mV (range, 0.06-0.36 mV). CONCLUSIONS: In patients referred for left ventricle outflow tract premature ventricular contraction ablation, an aortic valve closure artifact is observed in up to one third of cases during mapping within the aortic cusps. The timing of this artifact correlates with invasive hemodynamics and mechanical aortic valve artifacts. Recognition of this physiological phenomenon is useful when assigning near-field activation.


Asunto(s)
Válvula Aórtica/fisiopatología , Artefactos , Técnicas Electrofisiológicas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Taquicardia Ventricular/diagnóstico , Complejos Prematuros Ventriculares/diagnóstico , Potenciales de Acción , Adolescente , Anciano , Válvula Aórtica/cirugía , Ablación por Catéter , Niño , Electrocardiografía , Femenino , Frecuencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/cirugía , Factores de Tiempo , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía , Adulto Joven
17.
J Cardiovasc Electrophysiol ; 28(5): 523-530, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28185355

RESUMEN

INTRODUCTION: Patients with mitral regurgitation are increasingly treated by percutaneous implantation of a MitraClip device (Abbott Park, IL, USA). We investigate the feasibility and safety of the transmitral catheter route for catheter ablation of ventricular tachycardia (VT) in these patients. METHODS: The mitral valve with the MitraClip in situ was crossed under transesophageal 3-dimensional echocardiographic and fluoroscopic guidance using a steerable sheath for ablation of the left ventricle. RESULTS: Five patients (all males, median age 74.0 ± 16.0 years) who had previously a MitraClip implanted were referred for catheter ablation of VT. The left ventricular ejection fraction was 29.0% ± 24.0%. One patient had both an atrial septal defect and a left atrial appendage occluder device in addition to a MitraClip. The duration between MitraClip implantation and ablation was 1019.0 ± 783.0 days. After transseptal puncture, ablation catheter was successfully steered through the mitral valve with the use of fluoroscopy. A complete high-density map of the substrate in sinus rhythm could be obtained in all patients using multipolar mapping catheters. In 1 patient, mapping was carried out using a mini-basket catheter. Procedural endpoints, noninducibility of all VTs, and abolition of all late potentials were achieved in all patients. Procedure time was 255.0 ± 52.5 minute, fluoroscopy time was 23.0 ± 7.3, and the radiation dose was 61.0 ± 37.5 Gycm2 . No mitral insufficiency or worsening of regurgitation was documented after the procedure. CONCLUSIONS: This is the first report demonstrating the feasibility and safety of VT ablation in patients with a MitraClip device using the anterograde transmitral catheter route.


Asunto(s)
Ablación por Catéter , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Taquicardia Ventricular/cirugía , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Ablación por Catéter/efectos adversos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Técnicas Electrofisiológicas Cardíacas , Estudios de Factibilidad , Femenino , Fluoroscopía , Frecuencia Cardíaca , Humanos , Italia , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Radiografía Intervencional/métodos , Sistema de Registros , Suiza , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
19.
Ann Biomed Eng ; 45(2): 332-359, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27234818

RESUMEN

Mitral regurgitation is a common cardiac valve lesion, developing from primary lesions of the mitral valve or secondary to cardiomyopathies. Moderate or higher severity of mitral regurgitation imposes significant volume overload on the left ventricle, causing permanent structural and functional deterioration of the myocardium and heart failure. Timely correction of regurgitation is essential to preserve cardiac function, but surgical mitral valve repair is often delayed due to the risks of open heart surgery. Since correction of mitral regurgitation can provide symptomatic relief and halt progressive cardiac dysfunction, transcatheter mitral valve repair technologies are emerging as alternative therapies. In this approach, the mitral valve is repaired either with sutures or implants that are delivered to the native valve on catheters introduced into the cardiovascular system under image guidance, through small vascular or ventricular ports. Several transcatheter mitral valve technologies are in development, but limited clinical success has been achieved. In this review, we present a historical perspective of mitral valve repair, review the transcatheter technologies emerging from surgical concepts, the challenges they face in achieving successful clinical application, and the increasing rigor of safety and durability standards for new transcatheter valve technologies.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Animales , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA