Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
ACS Appl Mater Interfaces ; 13(41): 48403-48413, 2021 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-34610742

RESUMEN

Biofilms formed from the pathogenic bacteria that attach to the surfaces of biomedical devices and implantable materials result in various persistent and chronic bacterial infections, posing serious threats to human health. Compared to the elimination of matured biofilms, prevention of the formation of biofilms is expected to be a more effective way for the treatment of biofilm-associated infections. Herein, we develop a facile method for endowing diverse substrates with long-term antibiofilm property by deposition of a hybrid film composed of tannic acid/Cu ion (TA/Cu) complex and poly(ethylene glycol) (PEG). In this system, the TA/Cu complex acts as a multifunctional building block with three different roles: (i) as a versatile "glue" with universal adherent property for substrate modification, (ii) as a photothermal biocidal agent for bacterial elimination under irradiation of near-infrared (NIR) laser, and (iii) as a potent linker for immobilization of PEG with inherent antifouling property to inhibit adhesion and accumulation of bacteria. The resulted hybrid film shows negligible cytotoxicity and good histocompatibility and could prevent biofilm formation for at least 15 days in vitro and suppress bacterial infection in vivo, showing great potential for practical applications to solve the biofilm-associated problems of biomedical materials and devices.


Asunto(s)
Antibacterianos/uso terapéutico , Biopelículas/efectos de los fármacos , Incrustaciones Biológicas/prevención & control , Materiales Biocompatibles Revestidos/uso terapéutico , Cobre/uso terapéutico , Taninos/uso terapéutico , Animales , Antibacterianos/química , Antibacterianos/efectos de la radiación , Antibacterianos/toxicidad , Adhesión Bacteriana/efectos de los fármacos , Línea Celular , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/efectos de la radiación , Materiales Biocompatibles Revestidos/toxicidad , Cobre/química , Cobre/efectos de la radiación , Cobre/toxicidad , Escherichia coli/efectos de los fármacos , Rayos Infrarrojos , Masculino , Ratones , Pruebas de Sensibilidad Microbiana , Terapia Fototérmica , Polietilenglicoles/química , Polietilenglicoles/toxicidad , Ratas Sprague-Dawley , Piel/patología , Infecciones Cutáneas Estafilocócicas/tratamiento farmacológico , Infecciones Cutáneas Estafilocócicas/patología , Staphylococcus aureus/efectos de los fármacos , Taninos/química , Taninos/efectos de la radiación , Taninos/toxicidad
2.
Int J Biol Macromol ; 164: 4499-4515, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-32898537

RESUMEN

Herein, thermo- and pH-sensitive pectin-graft-poly(dimethylaminoethyl methacrylate) copolymer-coated magnetic nanoparticles were synthesized via a green and rapid synthetic approach based on microwave irradiation. Firstly, a novel thermo- and pH-sensitive pectin-graft-poly(dimethylaminoethyl methacrylate) copolymer (Pec-g-PolyDMAEMA) was synthesized and then, Pec-g-PolyDMAEMA based magnetic nanoparticles (Pec-g-PolyDMAEMA@Fe3O4) were produced via microwave-assisted co-precipitation method. The thermo/pH/magnetic field multi-sensitive hybrid nanoparticle was characterized by techniques like TEM, VSM, FT-IR, and TGA/DSC. In vitro release studies of 5-Fluorouracil (FL) were carried out by altering the temperature (37 and 44°C), pH (5.5 and 7.4) and presence of an AMF. The FL release of Pec-g-PolyDMAEMA@Fe3O4@FL exhibited pH-sensitive behavior. They showed thermo/pH-sensitive FL release features with the greatest release of FL at 37°C (56%) than at 44°C (40%) and at pH of 7.4 (63%) than at pH of 5.5 (45%) within 48h. The FL release was also significantly increased (100%) with the presence of a 50 mT magnetic field. These results indicate that the developed Pec-g-PolyDMAEMA@Fe3O4 nanoparticles are promising in the application of multi-stimuli-sensitive delivery of drugs.


Asunto(s)
Materiales Biocompatibles Revestidos , Portadores de Fármacos , Nanopartículas de Magnetita , Metacrilatos/química , Pectinas/química , Ácidos Polimetacrílicos/química , Animales , Antimetabolitos Antineoplásicos/administración & dosificación , Antimetabolitos Antineoplásicos/farmacología , Antimetabolitos Antineoplásicos/toxicidad , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/toxicidad , Liberación de Fármacos , Ensayos de Selección de Medicamentos Antitumorales , Fibroblastos/efectos de los fármacos , Fluorouracilo/administración & dosificación , Fluorouracilo/farmacología , Fluorouracilo/toxicidad , Humanos , Concentración de Iones de Hidrógeno , Células MCF-7 , Campos Magnéticos , Nanopartículas de Magnetita/administración & dosificación , Nanopartículas de Magnetita/toxicidad , Ratones , Transición de Fase , Ácidos Polimetacrílicos/síntesis química , Ácidos Polimetacrílicos/farmacología , Ácidos Polimetacrílicos/toxicidad , Solubilidad , Espectroscopía Infrarroja por Transformada de Fourier , Temperatura
3.
Acta Biomater ; 107: 313-324, 2020 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-32126308

RESUMEN

Titanium-based endosseous implants with high antibacterial and osseointegration activities are extremely required in clinics. To achieve this line, herein the doped coatings with three kinds of Zn doses were micro-arc oxidized (MAOed) on Ti. They were examined to reveal a bilayered structure, in which the outer layer consisted completely of the amorphism comprising elements of Ti, O and Zn with Zn doped in the form of weaken Zn-O bonds, and the underlying layer was partially crystallized with nanocrystalline TiO2 and Zn2TiO4 to embed an amorphous matrix. While the Zn doped doses of the surface amorphous layers increased with elevating the MAOed voltages, the weaken Zn-O bonds in the amorphism were identified to act as both the contributor of Zn2+ controllable release and the generator of reactive oxide species (ROS) on the coatings. The enhanced HO• and O2-• formation on the elevated voltage MAOed coatings caused serious break of the cell walls and plasma membranes of S. aureus. In parallel, the enhanced Zn2+ release and extracellular H2O2 formation led to the enhanced intracellular ROS level of S. aureus, further aggravating the damage of plasma membrane, resulting in bacteria death. On contrary to the overdose of Zn doped coating, the moderate doses of Zn doped coatings did not induce additional intracellular ROS and attenuate viability and proliferation of osteoblasts in vitro, and promoted osseointegration in both S. aureus-uninfected and infected rat tibias, which ascribed to the strong antibacterial activity and un-attenuated cell function of the coatings in the infected case. STATEMENT OF SIGNIFICANCE: (1) The Zn-doped coatings revealed a bilayered structure of the surface layer comprising the Ti, O and Zn constructed amorphism with Zn in the form of weaken Zn-O bonds, and the underlying layer comprising nanocrystalline TiO2 and Zn2TiO4 to embed amorphous matrix. (2) The weaken Zn-O bonds in the amorphism were identified to act as both the contributor of Zn2+ controllable release and the generator of ROS on the coatings. (3) The enhanced Zn2+ release and ROS formation on the coatings killed S. aureus by inducing serious break of their cell walls and plasma membranes. This effect in combination of un-attenuated osteoblast proliferation endowed the moderate Zn doped coatings with enhanced osseointegration in S. aureus-infected rat tibias.


Asunto(s)
Antibacterianos/uso terapéutico , Materiales Biocompatibles Revestidos/uso terapéutico , Oseointegración/efectos de los fármacos , Tibia/microbiología , Titanio/uso terapéutico , Zinc/uso terapéutico , Animales , Antibacterianos/química , Antibacterianos/toxicidad , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/toxicidad , Escherichia coli/efectos de los fármacos , Ratones , Pruebas de Sensibilidad Microbiana , Osteoblastos/efectos de los fármacos , Células RAW 264.7 , Ratas Sprague-Dawley , Especies Reactivas de Oxígeno/metabolismo , Staphylococcus aureus/efectos de los fármacos , Titanio/química , Titanio/toxicidad , Zinc/química , Zinc/toxicidad
4.
Appl Biochem Biotechnol ; 181(2): 725-734, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27778152

RESUMEN

Nanographene- and graphene-based nanohybrids have garnered attention in the biomedical community owing to their biocompatibility, excellent aqueous processability, ease of cellular uptake, facile surface functionalization, and thermal and electrical conductivities. NiO nanoparticle-graphene nanohybrid (G-NiO) was synthesized by first depositing Ni(OH)2 onto the surface of graphene oxide (GO) sheets. The Ni(OH)2-GO hybrids were then reduced to G-NiO using date palm syrup at 85 °C. The prepared G-NiO nanohybrids were characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), Fourier transform infrared spectroscopy, and energy-dispersive X-ray spectroscopy (EDX). The NiO nanoparticles, with a diameter of approximately 20-30 nm, were uniformly dispersed over the surface of the graphene sheets. The G-NiO hybrids exhibit biocompatibility in human mesenchymal stem cells (hMSCs) up to 100 µg/mL. The nanohybrids do not cause any significant changes in cellular and nuclear morphologies in hMSCs. The as-synthesized nanohybrids show excellent biocompatibility and could be a promising material for biomedical applications.


Asunto(s)
Grafito/química , Células Madre Mesenquimatosas/efectos de los fármacos , Nanopartículas del Metal/toxicidad , Níquel/química , Níquel/toxicidad , Phoeniceae/química , Absorción Fisicoquímica , Supervivencia Celular/efectos de los fármacos , Materiales Biocompatibles Revestidos/síntesis química , Materiales Biocompatibles Revestidos/toxicidad , Grafito/toxicidad , Humanos , Ensayo de Materiales , Células Madre Mesenquimatosas/citología , Nanopartículas del Metal/química , Extractos Vegetales/química , Extractos Vegetales/toxicidad
5.
J Biomed Nanotechnol ; 12(1): 154-64, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27301181

RESUMEN

Functionalization of nanoparticles with cationic moieties, such as polyethyleneimine (PEI), enhances binding to the cell membrane; however, it also disrupts the integrity of the cell's plasma and vesicular membranes, leading to cell death. Primary fibroblasts were found to display high surface affinity for cationic iron oxide nanoparticles and greater sensitivity than their immortalized counterparts. Treatment of cells with cationic nanoparticles in the presence of incremental increases in serum led to a corresponding linear decrease in cell death. The surface potential of the nanoparticles also decreased linearly as serum increased and this was strongly and inversely correlated with cell death. While low doses of nanoparticles were rendered non-toxic in 25% serum, large doses overcame the toxic threshold. Serum did not reduce nanoparticle association with primary fibroblasts, indicating that the decrease in nanoparticle cytotoxicity was based on serum masking of the PEI surface, rather than decreased exposure. Primary endothelial cells were likewise more sensitive to the cytotoxic effects of cationic nanoparticles than their immortalized counterparts, and this held true for cellular responses to cationic microparticles despite the much lower toxicity of microparticles compared to nanoparticles.


Asunto(s)
Apoptosis/efectos de los fármacos , Fibroblastos/efectos de los fármacos , Nanocápsulas/química , Nanocápsulas/toxicidad , Polietileneimina/toxicidad , Suero/química , Animales , Apoptosis/fisiología , Cationes , Línea Celular , Materiales Biocompatibles Revestidos/síntesis química , Materiales Biocompatibles Revestidos/toxicidad , Fibroblastos/citología , Fibroblastos/fisiología , Humanos , Ratones , Polietileneimina/química , Electricidad Estática , Propiedades de Superficie
6.
Mater Sci Eng C Mater Biol Appl ; 62: 28-35, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26952394

RESUMEN

An alternative approach to improve the cardiovascular stents with less restenosis than drug eluting stents, involves an improvement in endothelialization of implants. In this study, the bio compatibility of the modified Ti-50.9 Ni alloy was investigated. At the first step, a thermo-chemical surface modification process was used to control the Ni release of the alloy. XPS and Raman analysis revealed that the surface of the alloy contains titanium dioxide after the modification process. According to the Ni release test, this surface condition has a good durability in Ringer's solution and offers a standard range to the leached Ni. At the next step, porous Ca-P films were electrodeposited on the modified surface. The results of endothelial cell culture on the coated samples revealed that the Ca-P coating, which has the highest value of Ca/P ratio shows the best result. The coating revealed a moderately wettable surface with a water contact angle of 53.3°. According to Ca content analysis of the cell culture medium, this coating has the lowest amount of Ca as a result of minimum solubility of the coating. In the other Ca-P coatings with lower Ca/P ratios, the solubility of coatings results in the detachment of the cells. Also nano-indentation and SEM studies revealed that the low stiffness in the calcium deficient coating can result in the failure of the coating as a result of the tensions created by the cells.


Asunto(s)
Aleaciones/química , Calcio/química , Materiales Biocompatibles Revestidos/química , Fósforo/química , Materiales Biocompatibles Revestidos/síntesis química , Materiales Biocompatibles Revestidos/toxicidad , Elasticidad , Galvanoplastia , Células Endoteliales de la Vena Umbilical Humana , Humanos , Microscopía Electrónica de Rastreo , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie
7.
J Appl Toxicol ; 36(4): 510-20, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26708321

RESUMEN

Tumor recurrence after the incomplete removal of a tumor mass inside brain tissue is the main reason that scientists are working to identify new strategies in brain oncologic therapy. In particular, in the treatment of the most malignant astrocytic tumor glioblastoma, the use of magnetic nanoparticles seems to be one of the most promising keys in overcoming this problem, namely by means of magnetic fluid hyperthermia (MFH) treatment. However, the major unknown issue related to the use of nanoparticles is their toxicological behavior when they are in contact with biological tissues. In the present study, we investigated the interaction of glioblastoma and other tumor cell lines with superparamagnetic iron-oxide nanoparticles covalently coated with a rhamnose derivative, using proper cytotoxic assays. In the present study, we focused our attention on different strategies of toxicity evaluation comparing different cytotoxicological approaches in order to identify the biological damages induced by the nanoparticles. The data show an intensive internalization process of rhamnose-coated iron oxide nanoparticles by the cells, suggesting that rhamnose moiety is a promising biocompatible coating in favoring cells' uptake. With regards to cytotoxicity, a 35% cell death at a maximum concentration, mainly as a result of mitochondrial damages, was found. This cytotoxic behavior, along with the high uptake ability, could facilitate the use of these rhamnose-coated iron-oxide nanoparticles for future MFH therapeutic treatments.


Asunto(s)
Carcinógenos/toxicidad , Materiales Biocompatibles Revestidos/toxicidad , Daño del ADN/efectos de los fármacos , Dextranos/toxicidad , Nanopartículas de Magnetita/toxicidad , Ramnosa/toxicidad , Animales , Carcinógenos/química , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Materiales Biocompatibles Revestidos/química , Dextranos/química , Glioblastoma/tratamiento farmacológico , Humanos , Hipertermia Inducida , Nanopartículas de Magnetita/química , Ratones , Ratones Endogámicos BALB C , Especies Reactivas de Oxígeno/metabolismo , Ramnosa/química
8.
J Biomed Nanotechnol ; 11(12): 2275-85, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26510320

RESUMEN

The surface topographies of nanoporous anodic aluminum oxide (AAO) and titanium dioxide (TiO2) membranes have been shown to modulate cell response in orthopedic and skin wound repair applications. In this study, we: (1) demonstrate an improved atomic layer deposition (ALD) method for coating the porous structures of 20, 100, and 200 nm pore diameter AAO with nanometer-thick layers of TiO2 and (2) evaluate the effects of uncoated AAO and TiO2-coated AAO on cellular responses. The TiO2 coatings were deposited on the AAO membranes without compromising the openings of the nanoscale pores. The 20 nm TiO2-coated membranes showed the highest amount of initial protein adsorption via the micro bicinchoninic acid (micro-BCA) assay; all of the TiO2-coated membranes showed slightly higher protein adsorption than the uncoated control materials. Cell viability, proliferation, and inflammatory responses on the TiO2-coated AAO membranes showed no adverse outcomes. For all of the tested surfaces, normal increases in proliferation (DNA content) of L929 fibroblasts were observed over from 4 hours to 72 hours. No increases in TNF-alpha production were seen in RAW 264.7 macrophages grown on TiO2-coated AAO membranes compared to uncoated AAO membranes and tissue culture polystyrene (TCPS) surfaces. Both uncoated AAO membranes and TiO2-coated AAO membranes showed no significant effects on cell growth and inflammatory responses. The results suggest that TiO2-coated AAO may serve as a reasonable prototype material for the development of nanostructured wound repair devices and orthopedic implants.


Asunto(s)
Óxido de Aluminio/química , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Nanoestructuras , Titanio/química , Adsorción , Animales , Línea Celular , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Materiales Biocompatibles Revestidos/toxicidad , Macrófagos/efectos de los fármacos , Macrófagos/metabolismo , Ratones , Porosidad , Factor de Necrosis Tumoral alfa/biosíntesis
9.
Biomatter ; 3(3)2013.
Artículo en Inglés | MEDLINE | ID: mdl-23881040

RESUMEN

Zinc oxide (ZnO) is a widely used commercial material that is finding use in wound healing applications due to its antimicrobial properties. Our study demonstrates a novel approach for coating ZnO with precise thickness control onto 20 nm and 100 nm pore diameter anodized aluminum oxide using atomic layer deposition (ALD). ZnO was deposited throughout the nanoporous structure of the anodized aluminum oxide membranes. An 8 nm-thick coating of ZnO, previously noted to have antimicrobial properties, was cytotoxic to cultured macrophages. After 48 h, ZnO-coated 20 nm and 100 nm pore anodized aluminum oxide significantly decreased cell viability by ≈65% and 54%, respectively, compared with cells grown on uncoated anodized aluminum oxide membranes and cells grown on tissue culture plates. Pore diameter (20-200 nm) did not influence cell viability.


Asunto(s)
Óxido de Aluminio/química , Macrófagos/efectos de los fármacos , Óxido de Zinc/toxicidad , Animales , Supervivencia Celular/efectos de los fármacos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/toxicidad , Relación Dosis-Respuesta a Droga , Humanos , Ensayo de Materiales , Membranas Artificiales , Microscopía Electrónica de Rastreo , Nanoestructuras/química , Nanoestructuras/toxicidad , Propiedades de Superficie , Óxido de Zinc/química
10.
Mater Sci Eng C Mater Biol Appl ; 33(1): 153-64, 2013 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25428057

RESUMEN

In this study, a simple and versatile synthetic approach was developed to prepare bactericidal polyurethane coatings. For this purpose, introduction of both quaternary ammonium salts (QASs), with well-known antibacterial activity, and reactive hydroxyl groups on to the backbone of soybean oil was considered. Epoxidized soybean oil was reacted with diethylamine and the intermediate tertiary amine containing polyol was reacted with two different alkylating agents, methyl iodide and benzyl chloride, to produce MQAP and BQAP, respectively. These functional polyols were reacted with different diisocyanate monomers to prepare polyurethane coatings. Depending on the structure of monomers used for the preparation of polyurethane coatings, initial modulus, tensile strength and elongation at break of samples were in the ranges of 122-339 MPa, 4.6-12.4 MPa and 8.4-46%, respectively. Polyurethane coatings based on isophorone diisocyanate showed proper mechanical properties and adhesion strength (0.41 MPa) for coating application. Study of fibroblast cells interaction with prepared polyurethanes showed promising cells viability in the range of 78-108%. Meanwhile, MQAP based samples with higher concentration of QASs showed better adhesion strength, surface hydrophilicity and antibacterial activity (about 95% bacterial reduction). Therefore, these materials can find applications as bactericidal coating for biomedical devices and implants.


Asunto(s)
Antibacterianos/síntesis química , Materiales Biocompatibles Revestidos/síntesis química , Polímeros/química , Poliuretanos/química , Compuestos de Amonio Cuaternario/química , Aceite de Soja/química , Alquilantes/química , Aminas/química , Animales , Antibacterianos/química , Antibacterianos/farmacología , Línea Celular , Supervivencia Celular/efectos de los fármacos , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/toxicidad , Elasticidad , Bacterias Gramnegativas/efectos de los fármacos , Bacterias Grampositivas/efectos de los fármacos , Dureza , Interacciones Hidrofóbicas e Hidrofílicas , Ratones , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Resistencia a la Tracción , Viscosidad
11.
Toxicol Sci ; 88(2): 514-24, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16177240

RESUMEN

Most pigment-grade titanium dioxide (TiO(2)) samples that have been tested in pulmonary toxicity tests have been of a generic variety-i.e., generally either uncoated particles or TiO(2) particles containing slightly hydrophilic surface treatments/coatings (i.e., base TiO(2)). The objectives of these studies were to assess in rats, the pulmonary toxicity of inhaled or intratracheally instilled TiO(2) particle formulations with various surface treatments, ranging from 0-6% alumina (Al(2)O(3)) or alumina and 0-11% amorphous silica (SiO(2)). The pulmonary effects induced by TiO(2) particles with different surface treatments were compared to reference base TiO(2) particles and controls. In the first study, groups of rats were exposed to high exposure (dose) concentrations of TiO(2) particle formulations for 4 weeks at aerosol concentrations ranging from 1130-1300 mg/m(3) and lung tissues were evaluated by histopathology immediately after exposure, as well as at 2 weeks and 3, 6, and 12 months postexposure. In the second study, groups of rats were intratracheally instilled with nearly identical TiO(2) particle formulations (when compared to the inhalation study) at doses of 2 and 10 mg/kg. Subsequently, the lungs of saline-instilled and TiO(2)-exposed rats were assessed using both bronchoalveolar (BAL) biomarkers and by histopathology/cell proliferation assessment of lung tissues at 24 h, 1 week, 1 and 3 months postexposure. The results from these studies demonstrated that for both inhalation and instillation, only the TiO(2) particle formulations with the largest components of both alumina and amorphous silica surface treatments produced mildly adverse pulmonary effects when compared to the base reference control particles. In summary, two major conclusions can be drawn from these studies: (1) surface treatments can influence the toxicity of TiO(2) particles in the lung; and (2) the intratracheal instillation-derived, pulmonary bioassay studies represent an effective preliminary screening tool for inhalation studies with the identical particle-types used in this study.


Asunto(s)
Administración por Inhalación , Materiales Biocompatibles Revestidos/toxicidad , Intubación Intratraqueal , Pulmón/efectos de los fármacos , Titanio/administración & dosificación , Titanio/toxicidad , Aerosoles , Óxido de Aluminio/toxicidad , Animales , Biomarcadores/análisis , Líquido del Lavado Bronquioalveolar/química , Líquido del Lavado Bronquioalveolar/citología , Relación Dosis-Respuesta a Droga , Pulmón/patología , Macrófagos Alveolares/efectos de los fármacos , Macrófagos Alveolares/patología , Masculino , Neutrófilos/efectos de los fármacos , Neutrófilos/patología , Tamaño de la Partícula , Ratas , Ratas Sprague-Dawley , Dióxido de Silicio/toxicidad
12.
J Biomed Mater Res ; 58(6): 651-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11745517

RESUMEN

Hydroxyapatite coatings have been deposited on titanium cp by plasma spray, sol-gel, and sputtering techniques for dental implant applications. The latter two techniques are of current interest, as they allow coatings of micrometer dimensions to be deposited. Coating morphology, composition, and structure have been investigated by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). All coatings were homogeneous and exhibited a rough morphology suitable for implant applications. The sputtered (after annealing), plasma spray, and sol-gel coatings all showed diffraction peaks corresponding to hydroxyapatite. The surface contaminants were observed to be different for the different coating types. The sputtered coatings were found to have a composition most similar to hydroxyapatite; the sol-gel deposits also showed a high concentration of hydroxyl ions. A discrepancy in the Ca/P ratio was observed for the plasma spray coatings, and a small concentration of carbonate ions was found in the sputter-deposited coatings. The in vitro cell-culture studies using MG63 osteoblast-like cells demonstrated the ability of cells to proliferate on the materials tested. The sol-gel coating promotes higher cell growth, greater alkaline phosphatase activity, and greater osteocalcin production compared to the sputtered and plasma-sprayed coatings.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Durapatita/química , Metalurgia/métodos , Titanio/química , Fosfatasa Alcalina/análisis , Calcio/análisis , División Celular/efectos de los fármacos , Células Cultivadas/efectos de los fármacos , Células Cultivadas/metabolismo , Materiales Biocompatibles Revestidos/toxicidad , Durapatita/toxicidad , Geles , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Osteoblastos/efectos de los fármacos , Osteocalcina/biosíntesis , Fósforo/análisis , Polvos , Análisis Espectral , Difracción de Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA