1.
J Neural Eng ; 14(4): 046011, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28351998

RESUMEN

OBJECTIVE: Performance of many dielectric coatings for neural electrodes degrades over time, contributing to loss of neural signals and evoked percepts. Studies using planar test substrates have found that a novel bilayer coating of atomic-layer deposited (ALD) Al2O3 and parylene C is a promising candidate for neural electrode applications, exhibiting superior stability to parylene C alone. However, initial results from bilayer encapsulation testing on non-planar devices have been less positive. Our aim was to evaluate ALD Al2O3-parylene C coatings using novel test paradigms, to rigorously evaluate dielectric coatings for neural electrode applications by incorporating neural electrode topography into test structure design. APPROACH: Five test devices incorporated three distinct topographical features common to neural electrodes, derived from the utah electrode array (UEA). Devices with bilayer (52 nm Al2O3 + 6 µm parylene C) were evaluated against parylene C controls (N ⩾ 6 per device type). Devices were aged in phosphate buffered saline at 67 °C for up to 311 d, and monitored through: (1) leakage current to evaluate encapsulation lifetimes (>1 nA during 5VDC bias indicated failure), and (2) wideband (1-105 Hz) impedance. MAIN RESULTS: Mean-times-to-failure (MTTFs) ranged from 12 to 506 d for bilayer-coated devices, versus 10 to >2310 d for controls. Statistical testing (log-rank test, α = 0.05) of failure rates gave mixed results but favored the control condition. After failure, impedance loss for bilayer devices continued for months and manifested across the entire spectrum, whereas the effect was self-limiting after several days, and restricted to frequencies <100 Hz for controls. These results correlated well with observations of UEAs encapsulated with bilayer and control films. SIGNIFICANCE: We observed encapsulation failure modes and behaviors comparable to neural electrode performance which were undetected in studies with planar test devices. We found the impact of parylene C defects to be exacerbated by ALD Al2O3, and conclude that inferior bilayer performance arises from degradation of ALD Al2O3 when directly exposed to saline. This is an important consideration, given that neural electrodes with bilayer coatings are expected to have ALD Al2O3 exposed at dielectric boundaries that delineate electrode sites. Process improvements and use of different inorganic coatings to decrease dissolution in physiological fluids may improve performance. Testing frameworks which take neural electrode complexities into account will be well suited to reliably evaluate such encapsulation schemes.


Asunto(s)
Óxido de Aluminio/normas , Materiales Biocompatibles Revestidos/normas , Electrodos Implantados/normas , Diseño de Equipo/normas , Análisis de Falla de Equipo/métodos , Polímeros/normas , Xilenos/normas , Diseño de Equipo/instrumentación , Microelectrodos/normas , Microelectrodos/tendencias , Factores de Tiempo
2.
J Electromyogr Kinesiol ; 24(6): 795-802, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25287528

RESUMEN

This review discusses the advancements that are needed to enhance the effects of electrical stimulation for restoring or assisting movement in humans with an injury/disease of the central nervous system. A complex model of the effects of electrical stimulation of peripheral systems is presented. The model indicates that both the motor and sensory systems are activated by electrical stimulation. We propose that a hierarchical hybrid controller may be suitable for functional electrical stimulation (FES) because this type of controller acts as a structural mimetic of its biological counterpart. Specific attention is given to the neural systems at the periphery with respect to the required electrodes and stimulators. Furthermore, we note that FES with surface electrodes is preferred for the therapy, although there is a definite advantage associated with implantable technology for life-long use. The last section of the review discusses the potential need to combine FES and robotic systems to provide assistance in some cases.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Terapia por Estimulación Eléctrica/tendencias , Movimiento/fisiología , Músculo Esquelético/fisiología , Animales , Estimulación Eléctrica/métodos , Electrodos/tendencias , Electrodos Implantados/tendencias , Humanos , Microelectrodos/tendencias , Corteza Motora/fisiología
3.
J Neurosci Methods ; 201(2): 368-76, 2011 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-21889539

RESUMEN

Chronic single-unit recording in subcortical brain regions is increasingly important in neurophysiological studies. However, methods for long-term, stable recording of multiple single-units in deep brain regions and in dura-surrounded ganglion have not yet been established. In the present study, we propose a bundled microwire array design which is capable of long-term recording of the trigeminal ganglion and deep-brain units. This electrode set is easy to construct from common materials and tools found in an electrophysiological laboratory. The salient features of our design include: (1) short and separated tungsten microwires for stable chronic recording; (2) the use of a 30-guage stainless steel guide tube for facilitating penetration and aiming for deep targets as well as electrical grounding; (3) the inclusion of a reference of the same microwire material inside the bundle to enhance common mode rejection of far field noises; and (4) an adjustable connector. In our case, we used a 90° backward bending connector so that implanted rats could perform the same hole-seeking behavior and their faces and the whiskers could be stimulated in the behaving state. It was demonstrated that this multi-channel electrode caused minimal tissue damage at the recording site and we were able to obtain good, stable single-unit recordings from the trigeminal ganglion and ventroposterior medial thalamus areas of freely moving rats for up to 80 days. This methodology is useful for the studies that require long term and high quality unit recording in the deep brain or in the trigeminal system.


Asunto(s)
Potenciales de Acción/fisiología , Electrodos Implantados/normas , Electrofisiología/instrumentación , Microelectrodos/normas , Tálamo/fisiología , Ganglio del Trigémino/fisiología , Animales , Conducta Animal/fisiología , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Electrodos Implantados/tendencias , Electrofisiología/métodos , Femenino , Microelectrodos/tendencias , Movimiento/fisiología , Neuronas/fisiología , Ratas , Ratas Sprague-Dawley , Tálamo/citología , Tiempo , Ganglio del Trigémino/citología
4.
Neurotoxicology ; 32(1): 158-68, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21056592

RESUMEN

Due to lack of knowledge only a few industrial chemicals have been identified as developmental neurotoxicants. Current developmental neurotoxicity (DNT) guidelines (OECD and EPA) are based entirely on in vivo studies that are both time consuming and costly. Consequently, there is a high demand to develop alternative in vitro methods for initial screening to prioritize chemicals for further DNT testing. One of the most promising tools for neurotoxicity assessment is the measurement of neuronal electrical activity using micro-electrode arrays (MEAs) that provides a functional and neuronal specific endpoint that until now has been used mainly to detect acute neurotoxicity. Here, electrical activity measurements were evaluated to be a suitable endpoint for the detection of potential developmental neurotoxicants. Initially, primary cortical neurons grown on MEA chips were characterized for different cell markers over time, using immunocytochemistry. Our results show that primary cortical neurons could be a promising in vitro model for DNT testing since some of the most critical neurodevelopment processes such as progenitor cell commitment, proliferation and differentiation of astrocytes and maturation of neurons are present. To evaluate if electrical activity could be a suitable endpoint to detect chemicals with DNT effects, our model was exposed to domoic acid (DomA), a potential developmental neurotoxicant for up to 4 weeks. Long-term exposure to a low concentration (50nM) of DomA increased the basal spontaneous electrical activity as measured by spike and burst rates. Moreover, the effect induced by the GABA(A) receptor antagonist bicuculline was significantly lower in the DomA treated cultures than in the untreated ones. The MEA measurements indicate that chronic exposure to DomA changed the spontaneous electrical activity leading to the possible neuronal mal functioning. The obtained results suggest that the MEAs could be a useful tool to identify compounds with DNT potential.


Asunto(s)
Corteza Cerebral/efectos de los fármacos , Corteza Cerebral/embriología , Ácido Kaínico/análogos & derivados , Análisis por Micromatrices/tendencias , Neuronas/efectos de los fármacos , Animales , Células Cultivadas , Corteza Cerebral/fisiología , Evaluación Preclínica de Medicamentos , Femenino , Ácido Kaínico/toxicidad , Sistemas Microelectromecánicos , Microelectrodos/tendencias , Neuronas/fisiología , Embarazo , Ratas , Ratas Wistar
5.
Neurotoxicology ; 31(4): 331-50, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20399226

RESUMEN

Microelectrode arrays (MEAs) have been in use over the past decade and a half to study multiple aspects of electrically excitable cells. In particular, MEAs have been applied to explore the pharmacological and toxicological effects of numerous compounds on spontaneous activity of neuronal and cardiac cell networks. The MEA system enables simultaneous extracellular recordings from multiple sites in the network in real time, increasing spatial resolution and thereby providing a robust measure of network activity. The simultaneous gathering of action potential and field potential data over long periods of time allows the monitoring of network functions that arise from the interaction of all cellular mechanisms responsible for spatio-temporal pattern generation. In these functional, dynamic systems, physical, chemical, and pharmacological perturbations are holistically reflected by the tissue responses. Such features make MEA technology well suited for the screening of compounds of interest, and also allow scaling to high throughput systems that can record from multiple, separate cell networks simultaneously in multi-well chips or plates. This article is designed to be useful to newcomers to this technology as well as those who are currently using MEAs in their research. It explains how MEA systems operate, summarizes what systems are available, and provides a discussion of emerging mathematical schemes that can be used for a rapid classification of drug or chemical effects. Current efforts that will expand this technology to an influential, high throughput, electrophysiological approach for reliable determinations of compound toxicity are also described and a comprehensive review of toxicological publications using MEAs is provided as an appendix to this publication. Overall, this article highlights the benefits and promise of MEA technology as a high throughput, rapid screening method for toxicity testing.


Asunto(s)
Evaluación Preclínica de Medicamentos/instrumentación , Electrofisiología/instrumentación , Ensayos Analíticos de Alto Rendimiento/instrumentación , Microelectrodos/tendencias , Pruebas de Toxicidad/instrumentación , Animales , Técnicas de Cultivo de Célula/métodos , Humanos , Red Nerviosa/efectos de los fármacos , Red Nerviosa/fisiología
6.
J Neurosci Methods ; 142(1): 45-54, 2005 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-15652616

RESUMEN

Bulk micromachining techniques of silicon have been used successfully in the past several years to microfabricate microelectrodes for monitoring single neurons in acute and chronic experiments. In this study we report for the first time a novel surface micromachining technique to microfabricate a very thin polysilicon microelectrode that can be used for monitoring single-unit activity in the central nervous system. The microelectrodes are 3 mm long and 50 microm x 3.75 microm in cross-section. Excellent signal to noise ratios in the order of 25-35 dB were obtained while recording neuronal action potentials. The microelectrodes successfully penetrated the brains after a microincision of the dura mater. Chronic implantation of the microprobe for up to 33 days produced only minor gliosis. Since the polysilicon shank acts as a conductor, additional processing steps involved in laying conductor lines on silicon substrates are avoided. Further, surface micromachining allows for fabricating extremely thin microelectrodes which could result in decreased inflammatory responses. We conclude that the polysilicon microelectrode reported here could be a complementary approach to bulk-micromachined silicon microelectrodes for chronic monitoring of single neurons in the central nervous system.


Asunto(s)
Potenciales de Acción/fisiología , Encéfalo/fisiología , Electrofisiología/instrumentación , Neuronas/fisiología , Silicio/fisiología , Animales , Artefactos , Encéfalo/anatomía & histología , Encéfalo/cirugía , Duramadre/cirugía , Electrofisiología/métodos , Encefalitis/prevención & control , Gliosis/prevención & control , Microelectrodos/normas , Microelectrodos/tendencias , Ratas , Ratas Wistar , Silicio/química , Técnicas Estereotáxicas/instrumentación