Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
BMC Geriatr ; 23(1): 592, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37743501

RESUMEN

BACKGROUND: For the older person living with end-stage hip or knee osteoarthritis, a hip or knee replacement can be a traumatic event, influencing the physical, physiological, psychological, social and economic facets of daily living. This interpretative phenomenological study aimed to reveal and interpret the daily lived experiences of the older person before, during and after a primary total hip or knee replacement surgery in a fast-track programme in South Africa. METHODS: A qualitative interpretive phenomenological study, collecting data through solicited diaries and reflexive member validation interviews from seven participants aged 65-75 years, who underwent a primary elective hip or knee replacement surgery. The surgical fast-track process and data collection process happened simultaneously. Data collection from the solicited diary started before surgery, continued during the surgery process and finished six weeks after surgery and this was followed with reflexive member validation interviews. Interpretative phenomenological analysis was used throughout the three phases of the fast-track programme. RESULTS: Three superordinate themes developed during the three phases of surgery: "The holistic impact of pain on daily quality of life", "Finding ways to cope", and "Transition between independence and dependence and back". Although former research confirms the physical impact of osteoarthritis on the older person and the success of fast-track programmes for subsequent hip and knee replacements, this study contributes to the holistic impact of the surgery on participants' daily lives. The diarized journey of individuals through the psychological, psychosocial, physical, professional, and spiritual experience are described and interpreted in this study. CONCLUSIONS: Across the solicited diaries, it was clear that pain as catalyst impacted the daily activities of the individual physically, psychologically, and psychosocially. Pain was subjectively present at different intensities during all the phases of the replacement surgery, impairing mobilization and triggering roller-coaster emotions. In order to cope with physical and emotional difficulties while preparing and adjusting to the environment, participants reflected on social support, physical and professional support, and spirituality. Throughout the preparation, hospitalization and the recovery process, the transition between independence, dependence, and back to independence was significant, reinforcing the individual's determination to recover.


Asunto(s)
Osteoartritis de la Cadera , Osteoartritis de la Rodilla , Humanos , Anciano , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/cirugía , Calidad de Vida , Recolección de Datos , Dolor
2.
J Arthroplasty ; 38(12): 2541-2548, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37595769

RESUMEN

BACKGROUND: Utilization of total joint arthroplasty (TJA) is affected by differences linked to sex, race, and socioeconomic status; there is little information about how geographic variation contributes to these differences. We sought to determine whether discrepancies in TJA utilization exist in patients diagnosed with osteoarthritis (OA) based upon urban-rural designation in a universal coverage system. METHODS: We conducted a cohort study using data from a US-integrated healthcare system (2015 to 2019). Patients aged ≥50 years who had a diagnosis of hip or knee OA were included. Total hip arthroplasty and total knee arthroplasty utilization (in respective OA cohorts) was evaluated by urban-rural designation (urban, mid, and rural). Incidence rate ratios (IRRs) for urban-rural regions were modeled using multivariable Poisson regressions. RESULTS: The study cohort included 93,642 patients who have hip OA and 275,967 patients who had knee OA. In adjusted analysis, utilization of primary total hip arthroplasty was lower in patients living in urban areas (IRR = 0.87, 95% confidence interval = 0.81 to 0.94) compared to patients in rural regions. Similarly, total knee arthroplasty was used at a lower rate in urban areas (IRR = 0.88, 95% confidence interval = 0.82 to 0.95) compared with rural regions. We found no differences in the hip and knee groups within the mid-region. CONCLUSIONS: In hip and knee OA patients enrolled in a universal coverage system, we found patients living in urban areas had lower TJA utilization compared to patients living in rural areas. Further research is needed to determine how patient location contributes to differences in elective TJA utilization. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Cadera , Osteoartritis de la Rodilla , Humanos , Estudios de Cohortes , Cobertura Universal del Seguro de Salud , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Cadera/cirugía
3.
J Am Acad Orthop Surg ; 30(20): e1348-e1357, 2022 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-36044283

RESUMEN

INTRODUCTION: Previous studies have documented racial and ethnic disparities in total joint arthroplasty (TJA) utilization in the United States. A potential mediator of healthcare disparities is unequal access to care, and studies have suggested that disparities may be ameliorated in systems of universal access. The purpose of this study was to assess whether racial/ethnic disparities in TJA utilization persist in a universally insured population of patients enrolled in a managed healthcare system. METHODS: This retrospective cohort study used data from a US integrated healthcare system (2015 to 2019). Patients aged 50 years and older with a diagnosis of hip or knee osteoarthritis were included. The outcome of interest was utilization of primary total hip arthroplasty and/or total knee arthroplasty, and the exposure of interest was race/ethnicity. Incidence rate ratios (IRRs) were modeled using multivariable Poisson regression controlling for confounders. RESULTS: There were 99,548 patients in the hip analysis and 290,324 in the knee analysis. Overall, 10.2% of the patients were Black, 20.5% were Hispanic, 9.6% were Asian, and 59.7% were White. In the multivariable analysis, utilization of primary total hip arthroplasty was significantly lower for all minority groups including Black (IRR, 0.55, 95% confidence interval [CI], 0.52-0.57, P < 0.0001), Hispanic (IRR, 0.63, 95% CI, 0.60-0.66, P < 0.0001), and Asian (IRR, 0.64, 95% CI, 0.61-0.68, P < 0.0001). Similarly, utilization of primary total knee arthroplasty was significantly lower for all minority groups including Black (IRR, 0.52, 95% CI, 0.49-0.54, P < 0.0001), Hispanic (IRR, 0.72, 95% CI, 0.70-0.75, P < 0.0001), and Asian (IRR, 0.60, 95% CI, 0.57-0.63, P < 0.0001) (all in comparison with White as reference). CONCLUSIONS: In this study of TJA utilization in a universally insured population of patients enrolled in a managed healthcare system, disparities on the basis of race and ethnicity persisted. Additional research is required to determine the reasons for this finding and to identify interventions which could ameliorate these disparities.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Cadera , Osteoartritis de la Rodilla , Anciano , Etnicidad , Humanos , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Estados Unidos/epidemiología
4.
Holist Nurs Pract ; 36(6): 356-362, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33741758

RESUMEN

The use of complementary and alternative medicine (CAM) practices was common among patients with osteoarthritis (OA) since the patients experienced severe problems. The aim of this study was to determine the prevalence of CAM use and quality of life in pre-arthroplasty patients. This study was designed as a descriptive, consecutive survey of pre-arthroplasty patients due to hip and knee OA. Data were collected by the Personal Information Form, Western Ontario and McMaster Universities (WOMAC) Index, and EQ-5D-5L quality-of-life scale. Logistic regression was used to determine the risk factors of CAM usage; 74.4% of the patients used CAM methods. The most frequently used methods of CAM were biologically based herbal therapies. All patients indicated that they did not disclose CAM methods they used to their physicians. The median EQ-5D-5L index value of the patients was 0.08 and the median WOMAC score was 96.8. Furthermore, patients with right knee OA were found to have a higher risk of using CAM. This study demonstrated that communication between patients and health care professionals is generally poor, and there is an urgent need to develop patient education to minimize the risks and maximize the benefits of using CAM.


Asunto(s)
Terapias Complementarias , Osteoartritis de la Cadera , Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/terapia , Calidad de Vida , Osteoartritis de la Cadera/cirugía , Encuestas y Cuestionarios
5.
J Med Internet Res ; 23(9): e28320, 2021 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-34473068

RESUMEN

BACKGROUND: Osteoarthritis is a disabling condition that is often associated with other comorbidities. Total hip or knee arthroplasty is an effective surgical treatment for osteoarthritis when indicated, but comorbidities can impair their results by increasing complications and social and economic costs. Integrated care (IC) models supported by eHealth can increase efficiency through defragmentation of care and promote patient-centeredness. OBJECTIVE: This study aims to assess the effectiveness and cost-effectiveness of implementing a mobile health (mHealth)-enabled IC model for complex chronic patients undergoing primary total hip or knee arthroplasty. METHODS: As part of the Horizon 2020 Personalized Connected Care for Complex Chronic Patients (CONNECARE) project, a prospective, pragmatic, two-arm, parallel implementation trial was conducted in the rural region of Lleida, Catalonia, Spain. For 3 months, complex chronic patients undergoing total hip or knee arthroplasty and their caregivers received the combined benefits of the CONNECARE organizational IC model and the eHealth platform supporting it, consisting of a patient self-management app, a set of integrated sensors, and a web-based platform connecting professionals from different settings, or usual care (UC). We assessed changes in health status (12-item short-form survey [SF-12]), unplanned visits and admissions during a 6-month follow-up, and the incremental cost-effectiveness ratio. RESULTS: A total of 29 patients were recruited for the mHealth-enabled IC arm, and 30 patients were recruited for the UC arm. Both groups were statistically comparable for baseline characteristics, such as age; sex; type of arthroplasty; and Charlson index, American Society of Anesthesiologists classification, Barthel index, Hospital Anxiety and Depression scale, Western Ontario and McMaster Universities Osteoarthritis Index, and Pfeiffer mental status questionnaire scores. Patients in both groups had significant increases in the SF-12 physical domain and total SF-12 score, but differences in differences between the groups were not statistically significant. IC patients had 50% fewer unplanned visits (P=.006). Only 1 hospital admission was recorded during the follow-up (UC arm). The IC program generated savings in different cost scenarios, and the incremental cost-effectiveness ratio demonstrated cost-effectiveness. CONCLUSIONS: Chronic patients undergoing hip or knee arthroplasty can benefit from the implementation of patient-centered mHealth-enabled IC models aimed at empowering patients and facilitating transitions from specialized hospital care to primary care. Such models can reduce unplanned contacts with the health system and reduce overall health costs, proving to be cost-effective. Overall, our findings support the notion of system-wide cross-organizational care pathways supported by mHealth as a successful way to implement IC for patients undergoing elective surgery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prestación Integrada de Atención de Salud , Osteoartritis de la Cadera , Osteoartritis de la Rodilla , Osteoartritis , Telemedicina , Humanos , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Resultado del Tratamiento
6.
BMC Musculoskelet Disord ; 22(1): 376, 2021 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-33888114

RESUMEN

BACKGROUND: Osteopoikilosis (OPK) is a rare benign sclerosing bone dysplasia and is often incidentally found on plain radiography. OPK generally does not require treatment. Nevertheless, osteonecrosis or degenerative joint disease can occur in the setting of OPK, and little is known with regard to the longevity of arthroplasty prostheses implanted into OPK-bearing bones. CASE PRESENTATION: A 55-year-old male presented with progressive right hip pain in 2012. He was diagnosed with coexisting osteopoikilosis and developmental dysplasia of the right hip with advanced osteoarthritis after a series of imaging studies including radiographs, magnetic resonance imaging (MRI), and bone scan. A cementless total hip arthroplasty was performed to treat his right hip pain. Radiographs at eight-year follow-up showed the prosthetic components were well-fixed. Harris hip score of the patient's right hip was 93. The patient can walk without assistance and work as a construction worker. CONCLUSION: Cementless arthroplasty can be considered in patients with hip arthropathies and co-existing osteopoikilosis. Continued follow-up is required to establish the long-term results.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación Congénita de la Cadera , Luxación de la Cadera , Prótesis de Cadera , Osteoartritis de la Cadera , Osteopoiquilosis , Estudios de Seguimiento , Luxación Congénita de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/etiología , Osteoartritis de la Cadera/cirugía , Resultado del Tratamiento
7.
Arch Phys Med Rehabil ; 101(8): 1447-1461, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32437689

RESUMEN

OBJECTIVE: To determine the effectiveness of mental simulation practice (MSP) on measures of physical function recovery in patients who have undergone a joint replacement surgery of lower limbs. DATA SOURCES: A systematic review was conducted using CINAHL, PubMed/MEDLINE, Embase, SPORTDiscus, PEDro, Cochrane Register of Controlled Trials, and Google Scholar from the earliest record until August 16, 2019. STUDY SELECTION: The following inclusion criteria were used to determine eligibility for studies: (1) randomized and matched controlled trials recruiting men and women who underwent primary unilateral joint arthroplasty; (2) the study examined the effects of MSP intervention on measures of physical function recovery (both performance-based and patient self-reported); and (3) measures of interest were compared between MSP and control groups. A total of 8 papers (7 studies) met the inclusion criteria and were included. DATA EXTRACTION: Data were extracted by 1 reviewer and checked by a second reviewer, independently. DATA SYNTHESIS: When compared with standard physical therapy (SPT), MSP showed an effect on physical function in general (effect size [ES], 0.67; 95% confidence interval [CI], 0.38-0.96; n=7), maximal voluntary strength of knee extensor muscles of the affected leg (ES, 1.41; 95% CI, 0.64-2.18; n=2), brisk walking speed (ES, 1.20; 95% CI, 0.58-1.83; n=2), brisk walking speed with dual task (ES, 1.02; 95% CI, 0.41-1.63; n=2), timed up-to go test (ES, 0.96; 95% CI, 0.15-1.77; n=3), and active flexion of the affected leg (ES, 0.70; 95% CI, 0.29-1.11; n=4). Finally, meta-regression analysis revealed that the effects of MSP were significantly predicted only by total number of training sessions per study. CONCLUSIONS: The present meta-analysis demonstrated that MSP intervention has multiple positive effects on measures of physical function recovery in patients who have undergone total knee or hip replacement surgery in comparison with SPT. Thus, MSP can be applied as an effective complementary therapy to SPT in physical rehabilitation of this specific population, especially in the early postacute and acute phase.


Asunto(s)
Artroplastia de Reemplazo de Cadera/rehabilitación , Artroplastia de Reemplazo de Rodilla/rehabilitación , Terapia Conductista/métodos , Modalidades de Fisioterapia , Prueba de Esfuerzo , Humanos , Fuerza Muscular , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/cirugía , Músculo Cuádriceps/fisiopatología , Recuperación de la Función , Velocidad al Caminar
8.
Arch Orthop Trauma Surg ; 140(12): 1859-1866, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32048017

RESUMEN

BACKGROUND: Progressive oxidation of highly cross-linked ultra-high molecular weight (UHMPWE-X) liners is considered to be a risk factor for material failure in THA. Antioxidants such as vitamin E (alpha-tocopherol) (UHMWPE-XE) were supplemented into the latest generation of polyethylene liners. To prevent inhomogenous vitamin E distribution within the polymer, blending was established as an alternative manufacturing process to diffusion. The purpose of the present study was to investigate the in vivo wear behavior of UHMWPE-XE in comparison with conventional UHMWPE-X liners using virtual CAD-based radiographs. METHODS: Until now, 94 patients from a prospective, randomized, controlled, multicenter study were reviewed at 5-year follow-up. Of these, 51 (54%) received UHMWPE-XE and 43 (46%) UHMWPE-X liners. Anteroposterior pelvic radiographs were made immediately after surgery and at 1 and 5 years postoperatively. The radiographs were analyzed using the observer-independent analysis software RayMatch® (Raylytic GmbH, Leipzig, Germany). RESULTS: The mean wear rate was measured to be 23.6 µm/year (SD 13.7; range 0.7-71.8 µm). There were no significant differences between the two cohorts (UHMWPE-X: 23.2 µm/year vs. UHMWPE-XE: 24.0 µm/year, p = 0.73). Cup anteversion significantly changed within the 1st year after implantation independent from the type of polyethylene liner [UHMWPE-X: 18.2-23.9° (p = 0.0001); UHMWPE-XE: 21.0-25.5° (p = 0.002)]. No further significant changes of cup anteversion in both groups were found between year 1 and 5 after implantation [UHMWPE-X (p = 0.46); UHMWPE-XE (p = 0.56)]. CONCLUSION: The present study demonstrates that the addition of vitamin E does not adversely affect the midterm wear behavior of UHMWPE-X. The antioxidative benefit of vitamin E is expected to become evident in long-term follow-up. Cup anteversion increment by 5° within the 1st year is likely a result of the released hip flexion contracture resulting in an enhanced posterior pelvic tilt. Therefore, a reassessment of target values in acetabular cup placement might be considered.


Asunto(s)
Antioxidantes , Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Polietilenos , Diseño de Prótesis , Vitamina E , Acetábulo/cirugía , Adulto , Anciano , Diseño Asistido por Computadora , Femenino , Estudios de Seguimiento , Alemania , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Falla de Prótesis , Radiografía
9.
BMC Musculoskelet Disord ; 20(1): 172, 2019 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-30992064

RESUMEN

BACKGROUND: Hip resurfacing arthroplasty (HRA) and in particular, Birmingham hip resurfacing (BHR), is commonly employed as an alternative to total hip arthroplasty (THA) in young patients, as it allows for preservation of femoral bone stock and resumption of physical activity. The aim of our study was to investigate 5-year survival and functional outcomes of BHR arthroplasty in young Spanish osteoarthritis (OA) patients. METHODS: This is an observational, prospective, cohort study of patients who underwent BHR between June 2005 and December 2009 at a Spanish public hospital with a minimum follow-up of 5 years. All surgeries were performed by a single surgeon (RLM). Survival was analyzed using the Kaplan-Meier method. Functional outcomes and return to work and physical activities were also assessed. RESULTS: Five-year survival rate of the prosthesis was 95.74% (95% CI: 95.77-98.07), and estimated 10-year survival was 92.92% (95% CI: 85.07-96.72). Harris hip score significantly increased from 41.13 to 97.63 (p < 0.001) at 5-year follow-up. Average time for returning to work and sporting activities was 3.89 (SD: 2.39) and 3.47 (SD: 1.18) months respectively. Failure occurred in 14 patients, 8 of whom experienced femoral neck fractures. CONCLUSIONS: Our data support the short and mid-term efficacy of BHR arthroplasty in young OA patients, indicating good implant survival, improvement in patients' functionality and a swift return to work and physical activities after surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Osteoartritis de la Cadera/cirugía , Falla de Prótesis , Adulto , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Estudios de Seguimiento , Articulación de la Cadera/fisiología , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Rango del Movimiento Articular , Recuperación de la Función , Reoperación/estadística & datos numéricos , Reinserción al Trabajo/estadística & datos numéricos , España , Factores de Tiempo , Resultado del Tratamiento
10.
JMIR Mhealth Uhealth ; 7(1): e10342, 2019 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-30702438

RESUMEN

BACKGROUND: Recent developments in technology are promising for providing home-based exercise programs. OBJECTIVE: The objective of this study was to evaluate the feasibility and patient experience of a home-based rehabilitation program after total hip arthroplasty (THA) delivered using videos on a tablet personal computer (PC) and a necklace-worn motion sensor to continuously monitor mobility-related activities. METHODS: We enrolled 30 independently living patients aged 18-75 years who had undergone THA as a treatment for primary or secondary osteoarthritis (OA) between December 2015 and February 2017. Patients followed a 12-week exercise program with video instructions on a tablet PC and daily physical activity registration through a motion sensor. Patients were asked to do strengthening and walking exercises at least 5 days a week. There was weekly phone contact with a physiotherapist. Adherence and technical problems were recorded during the intervention. User evaluation was done in week 4 (T1) and at the end of the program (T2). RESULTS: Overall, 26 patients completed the program. Average adherence for exercising 5 times a week was 92%. Reasons mentioned most often for nonadherence were vacation or a day or weekend off 25% (33/134) and work 15% (20/134). The total number of technical issues was 8. The average score on the user evaluation questionnaire (range 0-5) was 4.6 at T1 and 4.5 at T2. The highest score was for the subscale "coaching" and the lowest for the subscale "sensor." CONCLUSIONS: A home-based rehabilitation program driven by a tablet app and mobility monitoring seems feasible for THA patients. Adherence was good and patient experience was positive. The novel technology was well accepted. When the home-based rehabilitation program proves to be effective, it could be used as an alternative to formal physiotherapy. However, further research on its effectiveness is needed.


Asunto(s)
Artroplastia de Reemplazo de Cadera/rehabilitación , Ejercicio Físico/psicología , Satisfacción del Paciente , Rehabilitación/instrumentación , Anciano , Estudios de Cohortes , Computadoras de Mano/normas , Computadoras de Mano/estadística & datos numéricos , Estudios de Factibilidad , Femenino , Servicios de Atención de Salud a Domicilio/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Osteoartritis de la Cadera/complicaciones , Osteoartritis de la Cadera/psicología , Osteoartritis de la Cadera/cirugía , Pacientes/psicología , Pacientes/estadística & datos numéricos , Estudios Prospectivos , Rehabilitación/métodos , Rehabilitación/psicología , Cumplimiento y Adherencia al Tratamiento/psicología , Resultado del Tratamiento
11.
Acta Orthop ; 89(3): 272-277, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29493328

RESUMEN

Background and purpose - The use of local infiltration anesthesia (LIA) has become one of the cornerstones of rapid recovery protocols in total knee arthroplasty patients during the past decade. In total hip arthroplasty (THR), however, the study results are more variable and LIA has therefore not yet been generally accepted. There is no consensus on which structure should be infiltrated and the cutaneous nerves are generally neglected. Hence, we hypothesized a pain-reducing effect of specifically blocking these nerves. Patients and methods - We performed a single-center randomized placebo-controlled trial in 162 subjects to evaluate the infiltration of the lateral cutaneous femoral and subcostal nerve with ropivacaine in patients undergoing total hip arthroplasty via a straight lateral approach. The primary endpoint was pain at rest after 24 hours. Patients were followed up to 6 weeks postoperatively. Results - After correction for multiple testing, no statistically significant differences in pain scores were found between the ropivacaine compared with the placebo group after surgery. In addition, no differences were observed in the use of escape pain medication, complications, and the length of hospital stay. Interpretation - We found no clinically meaningful differences in pain scores between placebo and ropivacaine patients in the postoperative period after THA performed via a straight lateral approach under spinal anesthesia and a multimodal pain regimen. Moreover, our primary endpoint, pain reduction after 24 hours, was not met. Further research should focus on the composition and volume of the LIA suspension, the optimal localization of the infiltration, and should be evaluated for every surgical approach separately.


Asunto(s)
Anestésicos Locales/uso terapéutico , Artroplastia de Reemplazo de Cadera/efectos adversos , Bloqueo Nervioso/métodos , Osteoartritis de la Cadera/cirugía , Dolor Postoperatorio/prevención & control , Ropivacaína/uso terapéutico , Anciano , Anestesia Local , Anestesia Raquidea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología
12.
Hip Int ; 28(2_suppl): 10-14, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30755120

RESUMEN

BACKGROUND:: Ceramic-on-ceramic (CoC) is currently a viable bearing combination in primary total hip arthroplasty (THA) and, due to its mechanical properties, it can be used in young patients requiring a long-lasting implant. The aim of this study is to report the results of a series of CoC THAs at a minimum 20 years follow-up. METHODS:: A retrospective study was conducted on the 1st 100 consecutive alumina-on-alumina arthroplasties performed by a single surgeon on 51 females and 40 males with an average age of 60.7 years. The mean preoperative Harris Hip Score was 35. The press-fit cup consisted of a pure titanium core with a titanium alloy mesh. Both the inlay and the head were made of dense polycrystalline surgical-grade alumina. The 32-mm femoral head was anchored on 3 different femoral components. RESULTS:: 19 patients with 22 THAs were died or lost, 2 anatomic cementless stems were revised due to sinking, 1 THA was revised for periprosthetic infection. 2 patients sustained a Vancouver B1 periprosthetic femoral fracture. None of the 78 THAs eligible for this study were revised for wear, breakage, noise of the ceramic components. None of the cups, none of the cemented stems, none of the cementless straight stems failed. HHS raised up to a mean value of 95. CONCLUSIONS:: The present report demonstrates that CoC coupling offers minimal wear at a long-term follow-up. Further studies are needed to evaluate whether the modern ceramic composites will confirm such excellent results in total hip replacement.


Asunto(s)
Óxido de Aluminio , Artroplastia de Reemplazo de Cadera/métodos , Predicción , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Fracturas Periprotésicas/cirugía , Cirujanos/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico , Fracturas Periprotésicas/diagnóstico , Diseño de Prótesis , Radiografía , Reoperación , Estudios Retrospectivos
13.
Trials ; 18(1): 514, 2017 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-29096686

RESUMEN

BACKGROUND: Vitamin D deficiency has been linked to poor outcomes after total hip replacement (THR) or total knee replacement (TKR), including lower patient-reported outcome measures (PROMs), peri-prosthetic infection and longer hospital stay. We present a randomised feasibility trial protocol designed to prospectively investigate the influence of vitamin D testing, and subsequent supplementation for deficiency, prior to THR/TKR. METHODS/DESIGN: One hundred adult patients undergoing primary THR/TKR for osteoarthritis at two NHS hospital trusts in North East England will be recruited. Exclusion criteria include lack of mental capacity, revision surgery, participants already taking vitamin D/calcium supplements, or a known contraindication to vitamin D treatment. Participants will be ineligible for the trial if they have an estimated glomerular filtration rate < 30 ml/minute. We will measure patients' vitamin D levels at baseline, and those identified as deficient (vitamin D < 50 nmol/L) will be randomised to receive either vitamin D supplementation or no supplementation prior to, and for 6 months following, surgery. Patients with a normal vitamin D level (≥50 nmol/L) will receive no supplementation. Vitamin D levels will be rechecked on the day of surgery and again at 6 months. Patients will also complete a lifestyle questionnaire, as well as the Oxford hip or knee and EQ-5D-3 L PROM questionnaires, at baseline and at 6 months following surgery. The aims are to determine the feasibility of the methodology and to gather data to inform the conduct of a future, larger trial to investigate if supplementation with vitamin D, in those who are deficient, prior to THR/TKR improves outcomes as measured by PROM scores. DISCUSSION: Previous reports have measured vitamin D levels and correlated this to outcome, but we can find no randomised trial in which researchers investigated the effect of supplementation. The aim of this trial is to determine if vitamin D deficiency is a modifiable risk factor for poor outcome after THR/TKR. TRIAL REGISTRATION: ISRCTN Registry, ISRCTN14533082 . Registered on 3 April 2017.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Colecalciferol/administración & dosificación , Suplementos Dietéticos , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/cirugía , Deficiencia de Vitamina D/tratamiento farmacológico , Colecalciferol/efectos adversos , Protocolos Clínicos , Suplementos Dietéticos/efectos adversos , Inglaterra , Estudios de Factibilidad , Humanos , Osteoartritis de la Cadera/complicaciones , Osteoartritis de la Cadera/diagnóstico , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/diagnóstico , Medición de Resultados Informados por el Paciente , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Proyectos de Investigación , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Vitamina D/análogos & derivados , Vitamina D/sangre , Deficiencia de Vitamina D/sangre , Deficiencia de Vitamina D/complicaciones , Deficiencia de Vitamina D/diagnóstico
14.
Folia Med (Plovdiv) ; 59(2): 217-221, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28704193

RESUMEN

BACKGROUND: Hip joint replacement (endoprosthesis, alloplasty) has become one of the most frequent surgery interventions of the 20th century. AIM: To conduct rehabilitation therapy in the late post-surgery period of hospital rehabilitation (45 days after surgery), to track patients' progress and measure the results. MATERIALS AND METHODS: One hundred and fifty-two patients with hip joint endoprosthesis were included in the study. All underwent surgery and rehabilitation at the Department of Clinical Rehabilitation of the Physical and Rehabilitation Medicine Clinic at Doctor G. Stranski University Hospital, Pleven. Kinesitherapy included therapeutic massage, isometric exercises for gluteal and hip muscles, isotonic exercises for the hip and the knee joint, breathing exercises, analytical gymnastics, exercises for balance and posture stability; gait control, exercises with gym equipment; occupational exercises included all activities of daily living (ADL) that were practiced at home; treatment with performed physical factors included applying magnetic field, interferential current therapy, electrostimulation of the m. quadriceps femoris and the gluteal muscles. RESULTS: The scores from the pain visual analog scale (VAS), the muscle strength test and the test for the movement volume of the hip joint were obtained at the beginning and at the end of the rehabilitation process and stored in an individual file for each patient. CONCLUSION: The results of the present study suggest that the complex rehabilitation program (kinesitherapy, performed physical factors and occupational therapy) can result in a considerably faster recovery and ensures that patients reach optimal functional results.


Asunto(s)
Artroplastia de Reemplazo de Cadera/rehabilitación , Terapia por Ejercicio/métodos , Fracturas del Cuello Femoral/cirugía , Osteoartritis de la Cadera/cirugía , Actividades Cotidianas , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Bulgaria , Estudios de Cohortes , Continuidad de la Atención al Paciente , Femenino , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/rehabilitación , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/rehabilitación , Dimensión del Dolor , Rango del Movimiento Articular/fisiología , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Factores de Tiempo , Resultado del Tratamiento
15.
J Rheumatol ; 44(7): 1066-1070, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28507182

RESUMEN

OBJECTIVE: The aim of this prospective cohort study was to determine whether dairy product consumption was associated with the incidence of total hip arthroplasty for osteoarthritis (OA). METHODS: There were 38,924 participants from the Melbourne Collaborative Cohort Study who had dairy product consumption recorded in 1990-1994. The incidence of total hip arthroplasty for OA during 2001-2013 was determined by linking cohort records to the Australian Orthopaedic Association National Joint Replacement Registry. RESULTS: Over an average of 11.8 years of followup, 1505 total hip arthroplasties for OA were identified (524 in men, 981 in women). In men, a 1 SD increase in dairy product consumption was associated with a 21% increased incidence of total hip arthroplasty for OA (HR 1.21, 95% CI 1.10-1.33), with a dose-response relationship observed for quartiles of dairy product consumption (p for trend = 0.001). These results were independent of age, body mass index, country of birth, education, smoking status, vigorous physical activity, calcium supplementation, energy consumption, circulating 25-hydroxy vitamin D, hypertension, and diabetes. No significant association was observed for women (HR 1.02, 95% CI 0.95-1.09). CONCLUSION: Increasing dairy product consumption was associated with an increased risk of total hip arthroplasty for men with OA, with no significant association observed for women. Understanding the mechanisms may help identify strategies to prevent hip OA, particularly for men.


Asunto(s)
Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Osteoartritis de la Cadera/cirugía , Anciano , Australia , Índice de Masa Corporal , Estudios de Cohortes , Productos Lácteos , Dieta , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Riesgo , Factores Sexuales
16.
Hip Int ; 27(1): 96-103, 2017 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-27834460

RESUMEN

PURPOSE: To compare 4 different bearings in total hip arthroplasty (THA) in a randomised controlled clinical study on clinical performance. METHODS: 393 patients with osteoarthritis of the hip or avascular necrosis were included and allocated to 1 of the head-and-cup couples zirconia-on-polyethylene (group A), metal-on-metal (group B), zirconia-on-polyethylene with the liner moulded into the shell (group C), or alumina-on-alumina (group D). In the individual case the surgeon could choose other implants if indicated. RESULTS: 299 patients were operated with the allocated prosthesis. The estimated cumulated prosthesis survival percentages and 95% confidence interval after 10 years were: group A 84.6 (75.8-93.4); group B 95.0 (89.5-100); group C 93.2 (86.7-99.7); group D 66.1 (54.5-77.7). The patients' physical function was significantly improved and remained equally good in all 4 groups, however slightly declining with ageing. The luxation rate was initially high, and equal between the groups, but was reduced by improving the surgical procedure introducing capsule repair by reinsertion of the short external hip rotators. CONCLUSIONS: The metal-on-metal or zirconia-on-polyethylene prostheses had high 10-year survival percentages. The longevity of these bearing couples by themselves was not related to the combination of materials. The zirconia-on-polyethylene prosthesis with the liner mounted peroperatively possibly exhibited cases of backside wear which the corresponding bearing couple with moulded polyethylene (Asian) did not. The alumina-on-alumina bearing performed poorly - it was redesigned after our study initiation and later withdrawn from the market.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Diseño de Prótesis/métodos , Falla de Prótesis , Anciano , Óxido de Aluminio/química , Análisis de Varianza , Artroplastia de Reemplazo de Cadera/métodos , Aleaciones de Cromo/química , Femenino , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Pronóstico , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Circonio/química
17.
Hip Int ; 27(1): 8-13, 2017 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-27791244

RESUMEN

INTRODUCTION: Ceramic-on-ceramic (CoC) couplings are alternative bearings surfaces that have been reported to reduce osteolysis, wear debris and aseptic loosening compared to the use of polyethylene. Early experiences with ceramics had poor results, but they have led to many improvements in the manufacture and design of subsequent implants. METHODS: We analysed medical files of 300 CoC total hip arthroplasty (THA) with a modular neck performed during period 1995-2000 by a single surgeon for a minimum follow-up of 13 years, evaluating clinical and radiological outcome. RESULTS: The mean clinical Merle d'Aubigne and Postel hip score at the final follow-up is 17.4, against a preoperative value of 11.4. Overall survivorship with an endpoint of revision is 93.2% (95% CI, 89.0%-97.3%) at 15 years, while considering only prosthesis failures related to aseptic loosening and ceramic breakage, survival rate at 15 years is 97.2% (95% CI, 94.8%-100%). We observed complications that led to revision surgery in 11 patients (4%) (periprosthetic fractures, liner ruptures, septic loosening of the implant, aseptic loosening of the cup, aseptic loosening of the stem). The occurrence of squeaking is low (1.6%, 4 cases) and we analysed the characteristics of these patients. DISCUSSION: Our study shows an excellent long term survivorship of third generation alumina CoC THA. We reiterate the importance to have a stable implant to maximise the advantage of ceramic and to avoid complications.


Asunto(s)
Óxido de Aluminio/química , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Diseño de Prótesis , Adulto , Factores de Edad , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Cohortes , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Falla de Prótesis , Reoperación/métodos , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Factores de Tiempo , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
18.
Med Sci Monit ; 22: 4406-4414, 2016 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-27853130

RESUMEN

BACKGROUND Osteoarthritis (OA) progressively produces symptoms and disability that may significantly reduce health-related quality of life (HRQoL). Total hip arthroplasty (THA) is an important treatment for symptomatic OA. An alternative to standard-stem THA for younger patients is short-stem THA. The aim of this study was to investigate potential HRQoL and functional outcome differences between these patient groups to provide additional data that will be clinically useful in the decision making between the types of prosthesis. MATERIAL AND METHODS In an 18-month follow-up longitudinal cohort study, we conducted Harris Hip Score (HHS) evaluations and SF-36 questionnaires in a study group and a control group undergoing short-stem and standard-stem THA preoperatively and during follow-up at 1, 3, 6, 12, and 18 months. Effect size was calculated to estimate the size of changes in scores during follow-up between chosen time intervals. RESULTS A total of 168 patients were included in the study. The total HHS score was significantly increased postoperatively from 46.9 to 87.0 in the standard-stem group, and from 42.7 to 85.1 in the short-stem group. All SF-36 scores improved after THA in both groups. No HRQoL or functional differences were found in the use of either surgical option in the HHS or SF-36 score results (all p>0.05). CONCLUSIONS As there were no differences in HRQoL in the two groups, we strongly recommend considering short-stem THA, especially in younger patients, due to the benefit of future revision options and a minimally invasive approach.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Osteoartritis de la Cadera/cirugía , Adulto , Estudios de Casos y Controles , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Encuestas y Cuestionarios , Resultado del Tratamiento
19.
J Arthroplasty ; 31(12): 2800-2804, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27378639

RESUMEN

BACKGROUND: The purpose of this retrospective study was to determine the clinical and radiographic results, prevalence of polyethylene wear and osteolysis, and fracture of alumina delta ceramic femoral head or highly crosslinked, remelted polyethylene (HXLPE) liner associated with the use of alumina delta ceramic femoral head-on-HXLPE bearing in cementless total hip arthroplasty in patients younger than 50 years. METHODS: We reviewed the cases of 119 patients (130 hips) who underwent a cementless total hip arthroplasty using alumina delta ceramic-on-HXLPE bearing when they were 50 years or younger at the time of surgery. The most common diagnoses were osteonecrosis (51%) and osteoarthritis secondary to developmental dysplastic hip (39%). Osteolysis and polyethylene wear rates were evaluated with use of radiography and computed tomography. In addition, prevalence of fracture of alumina delta ceramic head and polyethylene line was documented. The mean follow-up was 8.3 years (range, 7-9 years). RESULTS: The mean Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 94 points, 14 points, and 8.1 points, respectively, at the final follow-up. No patient had thigh pain. All acetabular components and all but one femoral components were well fixed. The mean annual penetration rate of femoral head was 0.022 ± 0.003 mm/year. No hip had osteolysis or ceramic head or HXLPE liner fracture. CONCLUSION: Our average 8.3-year results with the use of alumina delta ceramic-on-HXLPE bearing in the patients younger than 50 years suggest that cementless acetabular and femoral components provide a high survival rate without evidence of osteolysis or ceramic head or AXLPE liner fracture.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/estadística & datos numéricos , Diseño de Prótesis , Acetábulo/cirugía , Adulto , Óxido de Aluminio , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Cerámica , Femenino , Cabeza Femoral/cirugía , Necrosis de la Cabeza Femoral/cirugía , Estudios de Seguimiento , Luxación Congénita de la Cadera/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/etiología , Osteoartritis de la Cadera/cirugía , Osteólisis/diagnóstico por imagen , Osteólisis/epidemiología , Osteólisis/etiología , Polietileno , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , República de Corea/epidemiología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Adulto Joven
20.
J Arthroplasty ; 31(10): 2209-14, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27067468

RESUMEN

BACKGROUND: There are limited studies to evaluate long-term clinical and radiographic outcomes of alumina delta ceramic-on-ceramic bearings in cementless total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiographic results, prevalence of osteolysis, squeaking, and fracture of ceramic material associated with the use of the alumina delta ceramic-on-alumina delta ceramic bearing in cementless THA in patients aged <50 years. METHODS: We reviewed the cases of 277 patients (334 hips) who underwent a cementless THA using alumina delta ceramic-on-alumina delta ceramic when they were 50 years or younger at the time of surgery. Demographic data; Harris Hip Score; Western Ontario McMaster Universities Osteoarthritis Index; and University of California, Los Angeles activity score were recorded. Radiographic and computerized tomographic evaluations were used to evaluate implant fixation and osteolysis. Squeaking sound and ceramic fracture were documented. The mean follow-up was 13.1 years (range, 10-14). RESULTS: The mean postoperative Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 93 points, 15 points, and 8.6 points, respectively. Two patients had thigh pain (grade 7 points). All acetabular components and all but 2 femoral components were well fixed. Thirty-three hips (10%) exhibited clicking sound, and 2 hips (0.6%) exhibited squeaking sound. No hip had osteolysis or ceramic head or liner fracture. CONCLUSION: Our minimum 10-year follow-up results with the use of alumina delta ceramic-on-alumina delta ceramic bearings in patients aged <50 years suggest that cementless THA provides a high rate of survivorship without evidence of osteolysis or fracture of ceramic material.


Asunto(s)
Óxido de Aluminio , Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Osteólisis/epidemiología , Acetábulo/cirugía , Adulto , Enfermedades Óseas/cirugía , Cerámica , Femenino , Necrosis de la Cabeza Femoral/cirugía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Osteólisis/etiología , Diseño de Prótesis , República de Corea/epidemiología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA