Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
2.
Card Electrophysiol Clin ; 12(4): 475-493, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33161997

RESUMEN

An accessory pathway (AP) can be apparent during sinus rhythm if it depolarizes part of the ventricles ahead of the normal wave front from the conduction system. An AP can generate an anatomic circuit able to sustain a macroreentrant atrioventricular reentrant tachycardia. This arrhythmia can engage the normal conducting system in an antegrade direction or retrogradely, generating, respectively, a narrow or a wide complex tachycardia. The combined use of a standard electrocardiogram and an esophageal recording-pacing can be particularly useful in the first approach to patients with Wolff-Parkinson-White syndrome, further stratifying patients requiring electrophysiology study and transcatheter ablation.


Asunto(s)
Fascículo Atrioventricular Accesorio , Técnicas Electrofisiológicas Cardíacas , Taquicardia , Fascículo Atrioventricular Accesorio/diagnóstico , Fascículo Atrioventricular Accesorio/fisiopatología , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Medicina de Precisión , Taquicardia/diagnóstico , Taquicardia/fisiopatología , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/fisiopatología
3.
Card Electrophysiol Clin ; 12(4): 541-553, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33162002

RESUMEN

Accessory pathways are abnormal electrical conductions between the atrial and ventricular myocardium, bypassing the atrioventricular node and as such are an important substrate for arrhythmias. Ablation is a curative treatment and should always be offered to symptomatic patients and asymptomatic patients with high risk professions. Adequate knowledge and understanding of different mapping and ablation techniques is pivotal to achieve successful outcomes.


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter/métodos , Fascículo Atrioventricular Accesorio/diagnóstico , Fascículo Atrioventricular Accesorio/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Síndrome de Wolff-Parkinson-White/fisiopatología
4.
Rev Cardiovasc Med ; 21(2): 303-307, 2020 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-32706218

RESUMEN

A 36-year-old woman with 12-week gestation visited the emergency department, complaining of palpitations. Her electrocardiography (ECG) demonstrated ventricular pre-excitation combined with atrial fibrillation. The polarity of the delta waves in leads V5, V6, I, and aVL were positive and negative in leads V1, III, and aVF, suggesting that the accessory pathway (AP) was located on the right posterior free wall. She did not want to take any medicine to prevent the tachycardia. Moreover, the shortest pre-excited RR interval during the atrial fibrillation was 200 ms, so we decided to ablate the AP without fluoroscopy. An electrophysiology study was performed with guidance of a 3-dimension (3D) navigation system and intracardiac echocardiography (ICE). We ablated the right free wall AP without fluoroscopy. A follow-up ECG no longer exhibited any delta waves. Even in the early period of pregnancy, catheter ablation might be performed safely using ICE and a 3D navigation system without fluoroscopy. Therefore, it could more often be considered as a therapeutic option in pregnant women without concern for radiation exposure.


Asunto(s)
Ablación por Catéter , Complicaciones Cardiovasculares del Embarazo/cirugía , Exposición a la Radiación/prevención & control , Síndrome de Wolff-Parkinson-White/cirugía , Potenciales de Acción , Adulto , Ecocardiografía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Embarazo , Complicaciones Cardiovasculares del Embarazo/diagnóstico , Complicaciones Cardiovasculares del Embarazo/fisiopatología , Resultado del Tratamiento , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/fisiopatología
5.
Pediatr Cardiol ; 41(6): 1212-1219, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32529357

RESUMEN

Surrogates for the shortest pre-excited R-R interval in atrial fibrillation (SPERRI) such as the accessory pathway effective refractory period (APERP) and shortest pre-excited paced cycle length (SPPCL) are flawed assessments of accessory pathway function in patients with WPW. Multi-extrastimulus pacing may have the theoretical advantage of more accurately mimicking the clinical reality of atrial fibrillation and thus may serve to better assess accessory pathway function. This cross-sectional study included 25 consecutive patients, aged ≤ 18 years, undergoing electrophysiology study for WPW. The longest S1S2, S2S3, S3S4 coupling intervals at which the antegrade AP refractoriness occurred, SPERRI, and SPPCL were recorded. Induction of atrial fibrillation was attempted in all patients and induced in 8 (32%, 4 SPERRIbaseline (265 ms ± 61 ms), 4 SPERRIIsuprel (258 ms ± 41 ms)). At baseline, the lower value of the S3ERP or S4ERP (274 ms ± 52 ms) was lower than the SPPCL (296 ms ± 54 ms, p < 0.0001) and APERP (296 ms ± 41 ms, p < 0.0001). More patients had S3ERP or S4ERP ≤ 250 ms (12/25, 48%) compared to those with APERP ≤ 250 ms (2/25 8%), p = 0.0016), SPPCL 5/24, 20%), p = 0.008 or either (6/25, 24%), p = 0.0143). With Isuprel, the lower value of the S3ERP or S4ERP (221 ms ± 36 ms) trended to be lower than the APERP (252 ms ± 36 ms, p = 0.0001) and the SPPCL (266 ms ± 57 ms, p = 0.001). With Isuprel, there was no statistical difference in the proportion of patients with S3ERP or S4ERP < 250 ms (12/16, 75%) compared to those with APERP ≤ 250 ms ((9/16, 56%), p = 0.08), SPPCL ≤ 250 ms ((9/16, 56%), p = 0.08), or either ((10/16, 63%), p = 0.16). Multi-extrastimulus pacing protocols demonstrate that accessory pathways are less refractory than as defined by single extrastimulus pacing and straight decremental pacing.


Asunto(s)
Síndrome de Wolff-Parkinson-White/fisiopatología , Fascículo Atrioventricular Accesorio/complicaciones , Fascículo Atrioventricular Accesorio/fisiopatología , Adolescente , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Niño , Estudios Transversales , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Humanos , Masculino , Periodo Refractario Electrofisiológico , Medición de Riesgo , Síndrome de Wolff-Parkinson-White/complicaciones , Síndrome de Wolff-Parkinson-White/diagnóstico
6.
Crit Pathw Cardiol ; 19(2): 94-97, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31895133

RESUMEN

BACKGROUND: To investigate the relationship between the location of accessory pathways, electrophysiologic characteristics, and ablation success in Wolfe-Parkinson-White (WPW) syndrome. METHODS: Electrophysiologic study was performed in 178 patients for a pre-excitation syndrome. Accessory pathway location, anterograde or retrograde conduction, ablation success, and recurrence rate were evaluated. RESULTS: Among 178 patients with WPW syndrome, the most frequent location of the accessory pathway was left lateral (39.3%) which had high ablation success rate (97%) and low recurrence rate (1%). A meaningful relationship exists between accessory pathway location and electrophysiologic characteristics. Ablation success rate was 89.7% and was statistically related to accessory pathway location. Recurrent occurred in 2.9% of our patients and was more frequent in right free wall and PJRT. CONCLUSIONS: The location of accessory pathways has a great impact on conductivity, ablation success, and recurrence rate in WPW syndrome.


Asunto(s)
Fascículo Atrioventricular Accesorio/fisiopatología , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Síndrome de Wolff-Parkinson-White/fisiopatología , Fascículo Atrioventricular Accesorio/cirugía , Adulto , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Síndrome de Wolff-Parkinson-White/cirugía
7.
Heart Rhythm ; 17(2): 282-286, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31521806

RESUMEN

BACKGROUND: Children with Wolff-Parkinson-White Syndrome (WPW) are at risk for sudden death. The gold standard for risk stratification in this population is the shortest pre-excited RR interval during atrial fibrillation (SPERRI). OBJECTIVE: The purpose of this study was to determine how closely measurements made in the electrophysiology laboratory in patients with WPW compared to SPERRI obtained during an episode of clinical pre-excited atrial fibrillation (Clinical-SPERRI). METHODS: This was a subgroup analysis of a multicenter study of children with WPW. Subjects in our study (N = 49) were included if they had Clinical-SPERRI measured in addition to 1 or more of 3 surrogate measurements: SPERRI obtained during electrophysiological study (EP-SPERRI), accessory pathway effective refractory period (APERP), or shortest pre-excited paced cycle length with 1:1 conduction (SPPCL). RESULTS: Seventy percent of electrophysiological measurements were made with patients under general anesthesia. Clinical-SPERRI moderately correlated with EP-SPERRI (r = 0.495; P = .012). However, 24% of our patients with Clinical-SPERRI ≤250 ms would have been misclassified as having a low-risk pathway based on EP-SPERRI >250 ms. Clinical-SPERRI did not correlate with APERP or SPPCL (r < 0.3; P >.1). Mean EP-SPERRI, APERP, and SPPCL all were greater than Clinical-SPERRI. CONCLUSION: Electrophysiology laboratory measurements of pathway characteristics made with patients under general anesthesia do not correlate well with Clinical-SPERRI. Of APERP, SPPCL, and EP-SPERRI, only EP-SPERRI had moderate correlation with Clinical-SPERRI. This study questions the predictive ability of invasive risk stratification with patients under general anesthesia, given that 24% of patients with high-risk Clinical-SPERRI (≤250 ms) had EP-SPERRI that may be considered low risk (>250 ms).


Asunto(s)
Anestesia/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Medición de Riesgo/métodos , Síndrome de Wolff-Parkinson-White/fisiopatología , Adolescente , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos
9.
J Cardiovasc Electrophysiol ; 30(10): 2125-2129, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31328337

RESUMEN

We present a case of a 16-year-old male with WPW syndrome, referred for ablation after being resuscitated from cardiac arrest. Bipolar transseptal RF ablation successfully destroyed rapidly conducting epicardial posteroseptal accessory pathway after three failed attempts of endo- and epicardial ablation.


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter , Pericardio/cirugía , Síndrome de Wolff-Parkinson-White/cirugía , Fascículo Atrioventricular Accesorio/fisiopatología , Potenciales de Acción , Adolescente , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Humanos , Masculino , Pericardio/fisiopatología , Reoperación , Factores de Tiempo , Resultado del Tratamiento , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/fisiopatología
10.
Am J Cardiol ; 124(3): 389-395, 2019 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-31204032

RESUMEN

The rising utilization of screening electrocardiograms has resulted in increased incidental identification of ventricular pre-excitation in pediatric patients. We compared accessory pathways of incidentally identified pre-excitation to Wolff-Parkinson-White Syndrome (WPW) with the aim to identify factors important in preprocedural counseling and planning. This single-center, retrospective study of patients ≤18 years without congenital heart disease identified 227 patients diagnosed with pre-excitation and referred for invasive electrophysiology study between 2008 and 2017. WPW Syndrome was diagnosed in 178 patients, while 49 patients had incidental identification of pre-excitation. Anterograde conduction of incidentally identified accessory pathways was not clinically different between the two cohorts at baseline or upon isoproterenol infusion. However, the proportion of accessory pathways meeting high-risk criteria was significantly lower than in patients diagnosed with WPW, 12% versus 28% (p < 0.05). Retrograde conduction at baseline of incidentally diagnosed accessory pathways was slower with a median block cycle length 365 milliseconds (IQR 260 to 450) versus 290 milliseconds (IQR 260 to 330, p < 0.01). In the incidentally identified cohort, right-sided, paraHisian, and fascicular pathways were more common with fewer attempted ablations (71% vs 94%, p < 0.001) and lower success rate (91% vs 97%, p < 0.001). A binomial logistic regression analysis further indicated patients incidentally identified with pre-excitation were associated with having lower rates of inducible supraventricular tachycardia, atrial fibrillation, and ablations performed, in addition, to having right-sided pathways. In conclusion, as patients with incidentally identified pre-excitation present more frequently for consideration of invasive electrophysiology study, these results impact procedural approaches, technical considerations, patient counseling, and outcome expectations.


Asunto(s)
Fascículo Atrioventricular Accesorio/diagnóstico , Técnicas Electrofisiológicas Cardíacas , Síndromes de Preexcitación/fisiopatología , Síndrome de Wolff-Parkinson-White/fisiopatología , Fascículo Atrioventricular Accesorio/fisiopatología , Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter , Niño , Preescolar , Electrocardiografía , Femenino , Humanos , Hallazgos Incidentales , Masculino , Síndromes de Preexcitación/diagnóstico , Síndromes de Preexcitación/cirugía , Estudios Retrospectivos , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirugía
11.
PLoS One ; 14(6): e0217282, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31242221

RESUMEN

BACKGROUND: In previous pilot work we demonstrated that a novel automated signal analysis tool could accurately identify successful ablation sites during Wolff-Parkinson-White (WPW) ablation at a single center. OBJECTIVE: We sought to validate and refine this signal analysis tool in a larger multi-center cohort of children with WPW. METHODS: A retrospective review was performed of signal data from children with WPW who underwent ablation at two pediatric arrhythmia centers from 2008-2015. All patients with WPW ≤ 21 years who underwent invasive electrophysiology study and ablation with ablation signals available for review were included. Signals were excluded if temperature or power delivery was inadequate or lesion time was < 5 seconds. Ablation lesions were reviewed for each patient. Signals were classified as successful if there was loss of antegrade and retrograde accessory pathway (AP) conduction or unsuccessful if ablation did not eliminate AP conduction. Custom signal analysis software analyzed intracardiac electrograms for amplitudes, high and low frequency components, integrated area, and signal timing components to create a signal score. We validated the previously published signal score threshold 3.1 in this larger, more diverse cohort and explored additional scoring options. Logistic regression with lasso regularization using Youden's index criterion and a cost-benefit criterion to identify thresholds was considered as a refinement to this score. RESULTS: 347 signals (141 successful, 206 unsuccessful) in 144 pts were analyzed [mean age 13.2 ± 3.9 years, 96 (67%) male, 66 (45%) left sided APs]. The software correctly identified the signals as successful or unsuccessful in 276/347 (80%) at a threshold of 3.1. The performance of other thresholds did not significantly improve the predictive ability. A signal score threshold of 3.1 provided the following diagnostic accuracy for distinguishing a successful from unsuccessful signal: sensitivity 83%, specificity 77%, PPV 71%, NPV 87%. CONCLUSIONS: An automated signal analysis software tool reliably distinguished successful versus unsuccessful ablation electrograms in children with WPW when validated in a large, diverse cohort. Refining the tools using an alternative threshold and statistical method did not improve the original signal score at a threshold of 3.1. This software was effective across two centers and multiple operators and may be an effective tool for ablation of WPW.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas , Procesamiento de Señales Asistido por Computador , Programas Informáticos , Síndrome de Wolff-Parkinson-White , Adolescente , Niño , Femenino , Humanos , Masculino , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Síndrome de Wolff-Parkinson-White/fisiopatología , Síndrome de Wolff-Parkinson-White/cirugía
12.
J Cardiovasc Electrophysiol ; 30(7): 1036-1041, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30938913

RESUMEN

INTRODUCTION: Adenosine challenge (AC) can be used to evaluate possible Wolff-Parkinson-White (WPW) pattern on an electrocardiogram (ECG). Despite the use of this technique, there is a paucity of studies in the pediatric population evaluating the efficacy, safety, and outcomes of this testing modality. METHODS AND RESULTS: All ACs performed from January 2009 to June 2017 were retrospectively reviewed. Patient demographics, adenosine dosing, results, adverse effects, and outcomes including results of electrophysiology studies (EPS) were reviewed. Analysis was conducted between AC positive and negative cohorts. ECG criteria of shortest PR interval, longest QRS duration, and the number of suspected pre-excited leads were evaluated for inter-rater reliability and correlation to positive AC. Fifty-six AC (n = 51) were performed (median age, 13.8; range, 0.3-20 years). Forty-one AC were pre-EPS and 15 post-EPS due to concern for recurrent WPW. Thirty-one (76%) pre-EPS AC were negative, 9 (22%) positive, and 1 (2%) equivocal. EPS was performed following seven positive AC revealing 5 (71%) left posterior and 2 (29%) right posteroseptal AP. The 15 post-EPS AC were all found to be negative. Mean effective adenosine dose was 0.2 ± 0.11 mg/kg. No adverse events were reported. Mean follow up duration after AC was 314 ± 482 days with no documented arrhythmias. CONCLUSION: Adenosine challenge is an effective and safe testing modality for subtle WPW in the pediatric population. In our population, there were no adverse events or documented arrhythmias in patients following a negative study.


Asunto(s)
Adenosina/administración & dosificación , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Síndrome de Wolff-Parkinson-White/diagnóstico , Potenciales de Acción , Adenosina/efectos adversos , Adolescente , Factores de Edad , Niño , Preescolar , Bases de Datos Factuales , Femenino , Humanos , Lactante , Masculino , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Tiempo , Síndrome de Wolff-Parkinson-White/fisiopatología , Adulto Joven
13.
Pediatr Cardiol ; 40(1): 194-197, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30203293

RESUMEN

Ablation of accessory pathways (AP) is one of the most often performed procedures in pediatric electrophysiology. In pediatric patients these procedures are mostly performed in anaesthesia or sedation. In some of these patients who are referred for electrophysiologic (EP) study, we could observe disappearance of the preexcitation, i.e. antegrade conduction of an AP during introduction of sedation. As a suppression of AP conduction capacities has been reported as negative side effect of propofol and other anaesthetics, the aim of this study was to evaluate risk factors for drug-induced suppression of AP conduction properties. Consecutive, pediatric patients with Wolff-Parkinson-White (WPW) pattern referred for EP study in the period of 2016-2017 were reviewed in retrospect. Patients with complex congenital heart disease were excluded. An entire chart review including ECG, bicycle stress testing, and periprocedural data was performed. In 4 of 37 patients included into the study, loss of preexcitation could be observed during sedation. Data analysis showed weaker conduction capacities of the AP as a risk factor (p = 0.009). Interestingly, absolute (p = 0.11) or adjusted to body weight (p = 0.92) drug doses were not a relevant risk factor. Patients with WPW and weaker conduction capacities of the AP, as implied by an early disappearance of preexcitation during exercise stress testing, seem to be more prone to drug-induced suppression of an AP.


Asunto(s)
Anestesia/efectos adversos , Sistema de Conducción Cardíaco/fisiopatología , Hipnóticos y Sedantes/efectos adversos , Propofol/efectos adversos , Síndrome de Wolff-Parkinson-White/fisiopatología , Fascículo Atrioventricular Accesorio/fisiopatología , Fascículo Atrioventricular Accesorio/cirugía , Adolescente , Niño , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Prueba de Esfuerzo , Femenino , Humanos , Hipnóticos y Sedantes/administración & dosificación , Masculino , Propofol/administración & dosificación , Estudios Retrospectivos , Factores de Riesgo , Síndrome de Wolff-Parkinson-White/etiología , Síndrome de Wolff-Parkinson-White/cirugía
16.
Turk Kardiyol Dern Ars ; 46(6): 488-493, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30204140

RESUMEN

A 31-year-old male patient presented with complaints of palpitations, dizziness, and recurrent episodes of syncope. A 12-lead electrocardiogram (ECG) revealed manifest ventricular preexcitation, which suggested Wolff Parkinson White syndrome. In addition, an incomplete right bundle branch block and a 3-mm ST segment elevation ending with inverted T-waves in V2 were consistent with coved-type (type 1) Brugada pattern. An electrophysiological study was performed, and during the mapping, the earliest ventricular activation with the shortest A-V interval was found on the mitral annulus posterolateral site. After successful radiofrequency catheter ablation of the accessory pathway, the Brugada pattern on the ECG changed, which prompted an ajmaline provocation test. A type 1 Brugada ECG pattern occurred following the administration of ajmaline. Considering the probable symptom combinations of these 2 coexisting syndromes and the presence of recurrent episodes of syncope, programmed ventricular stimulation was performed and subsequently, ventricular fibrillation was induced. An implantable cardioverter-defibrillator was implanted soon after.


Asunto(s)
Síndrome de Brugada/complicaciones , Síndrome de Wolff-Parkinson-White/complicaciones , Adulto , Ajmalina/administración & dosificación , Animales , Antiarrítmicos/administración & dosificación , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/terapia , Bloqueo de Rama , Ablación por Catéter , Desfibriladores Implantables , Mareo , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Recurrencia , Síncope , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Síndrome de Wolff-Parkinson-White/fisiopatología , Síndrome de Wolff-Parkinson-White/terapia
17.
Arch. cardiol. Méx ; 88(3): 212-218, jul.-sep. 2018. tab, graf
Artículo en Español | LILACS | ID: biblio-1088752

RESUMEN

Resumen Objetivos: Las vías accesorias (VAc) fascículo-ventriculares (FV) tienen una localización anatómica similar a las VAcanteroseptales derechas (ASD) y comparten características electrocardiográficas. El objetivo es comparar características electrocardiográficas de las VAC FV con las de las ASD en pediatría. Métodos: Se incluyeron pacientes con preexcitación manifiesta sometidos a estudio electrofisiológico. Las VAc FV se definieron por un intervalo HV ≤ 32ms y un alargamiento del AH sin modificación del HV, del grado o patrón de preexcitación ventricular durante la estimulación auricular. Tres observadores independientes y ciegos analizaron los ECG en cada grupo. Resultados: De 288 pacientes, 15 (5.2%) presentaban VAC FV y 14 VAC ASD (4.9%). El intervalo PR fue más largo en las VAc FV que en las ASD (113 ± 21 vs. 86 ± 13 ms respectivamente; p = < 0.001) y la duración del QRS fue menor (95 ± 12 vs. 137 ± 24 ms respectivamente; p = < 0.001). El ECG de las VAc FV presentó una deflexión rápida de baja amplitud previa al inicio del QRS en 13 de 15 pacientes (87%) y en 2 con VAc AV ASD (14%); (p = 0.003). Conclusiones: El intervalo PR fue más largo y el complejo QRS más angosto en la VAC FV respecto de las ASD. La presencia de una deflexión rápida de baja amplitud previa al inicio del QRS permitiría diferenciarlas de las aurículo-ventriculares ASD de manera no invasiva.


Abstract Objectives: Fasciculo-ventricular (FV) accessory pathways (AP's) and right anteroseptal (RAS) AP's share similar anatomic locations and electrocardiographic characteristics. The objective of this article is to compare these features in children. Methods: All patients with manifest pre-excitation who underwent an electrophysiological study were included. Fasciculo-ventricular AP's were defined by the presence of an HV inter- val ≤ 32 ms and a prolongation of the AH without changes in the HV interval, or the level of pre-excitation during atrial pacing. Three independent and blind observers analysed the ECG's in both groups. Results: Out of 288 patients, 15 (5.2%) had FV AP's and 14 (4.9%) right AS AP's. The PR interval was longer in FV AP's than in RAS (113 ± 21 vs 86 ± 13 ms respectively; P < .001) and the QRS was narrower (95 ± 12 vs 137 ± 24 ms respectively; P < .001). The ECG in patients with FV AP's showed a rapid low amplitude deflection at the begining of the QRS in 13 out of 15 patients (87%) and in 2 (14%) the RAS AP group (P = .003). Conclusions: The PR interval was longer and the QRS complex was narrower in patients with FV AP's. The presence of a rapid low amplitude deflection at the beginning of the QRS complex would allow to differentiate them from RAS AP's non-invasively.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Síndrome de Wolff-Parkinson-White/diagnóstico , Electrocardiografía/métodos , Tabique Interventricular/fisiopatología , Fascículo Atrioventricular Accesorio/diagnóstico , Síndrome de Wolff-Parkinson-White/fisiopatología , Estudios Retrospectivos , Técnicas Electrofisiológicas Cardíacas , Fascículo Atrioventricular Accesorio/fisiopatología
18.
Int Heart J ; 59(4): 857-861, 2018 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-29794387

RESUMEN

Although the efficacy of catheter ablation of the accessory pathway (AP) has been established, there are subgroups of APs with an intermittent conduction property, which is sometimes difficult to diagnose accurately. A 57-year-old man with a history of catheter ablation was referred to our clinic due to frequent faintness. He had undergone concealed AP ablation 8 years previously and bilateral circumferential pulmonary vein isolation (CPVI) 6 years previously. During regular electrocardiogram monitoring, it was suggested that irregular wide QRS tachycardia, which was considered to be atrial fibrillation with antegrade AP conduction, was the cause of the present symptoms. In the present electrophysiological study, we noticed a residual antegrade AP in the left lateral wall that was not observed during the previous session. We achieved abolition of overt accessory conduction, bilateral CPVI, and superior vena cava isolation with several radiofrequency applications without any recurrence. We also confirmed the absence of dormant conduction in the AP and the left atrium-PV connection with 20 mg adenosine triphosphate. This case demonstrated the possibility of sudden exposure of overt AP conduction late after catheter ablation of the concealed AP and the importance of confirming the absence of dormant conduction by means of adenosine triphosphate, which has the potential benefit of revealing latent AP conduction.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas/métodos , Complicaciones Posoperatorias , Síndrome de Wolff-Parkinson-White/cirugía , Fascículo Atrioventricular Accesorio/diagnóstico por imagen , Fascículo Atrioventricular Accesorio/cirugía , Adenosina Trifosfato/farmacología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Electrocardiografía/métodos , Humanos , Masculino , Persona de Mediana Edad , Neurotransmisores/farmacología , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Venas Pulmonares/cirugía , Reoperación/métodos , Resultado del Tratamiento , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/fisiopatología
19.
J Electrocardiol ; 51(3): 467-469, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29478804

RESUMEN

Atrioventricular reciprocating tachycardia (AVRT) and atrioventricular nodal re-entrant tachycardia (AVNRT) can coexist and present unidirectional transition (from AVRT to AVNRT, or from AVNRT to AVRT) in a single patient. Actually, such cases have already been reported previously. However, a case with spontaneous bidirectional transition of both tachycardias during supraventricular tachycardia has never been reported. This article describes a case with spontaneous, mutual, and frequent transition between AVRT and AVNRT.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirugía , Ablación por Catéter , Diagnóstico Diferencial , Ecocardiografía , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Síndrome de Wolff-Parkinson-White/fisiopatología
20.
Arch Cardiol Mex ; 88(3): 212-218, 2018.
Artículo en Español | MEDLINE | ID: mdl-28666599

RESUMEN

OBJECTIVES: Fasciculo-ventricular (FV) accessory pathways (AP's) and right anteroseptal (RAS) AP's share similar anatomic locations and electrocardiographic characteristics. The objective of this article is to compare these features in children. METHODS: All patients with manifest pre-excitation who underwent an electrophysiological study were included. Fasciculo-ventricular AP's were defined by the presence of an HV interval≤32ms and a prolongation of the AH without changes in the HV interval, or the level of pre-excitation during atrial pacing. Three independent and blind observers analysed the ECG's in both groups. RESULTS: Out of 288 patients, 15 (5.2%) had FV AP's and 14 (4.9%) right AS AP's. The PR interval was longer in FV AP's than in RAS (113±21 vs 86±13ms respectively; P<.001) and the QRS was narrower (95±12 vs 137±24ms respectively; P<.001). The ECG in patients with FV AP's showed a rapid low amplitude deflection at the begining of the QRS in 13 out of 15 patients (87%) and in 2 (14%) the RAS AP group (P=.003). CONCLUSIONS: The PR interval was longer and the QRS complex was narrower in patients with FV AP's. The presence of a rapid low amplitude deflection at the beginning of the QRS complex would allow to differentiate them from RAS AP's non-invasively.


Asunto(s)
Fascículo Atrioventricular Accesorio/diagnóstico , Electrocardiografía/métodos , Tabique Interventricular/fisiopatología , Síndrome de Wolff-Parkinson-White/diagnóstico , Fascículo Atrioventricular Accesorio/fisiopatología , Adolescente , Niño , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Estudios Retrospectivos , Síndrome de Wolff-Parkinson-White/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA