Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Mod Pathol ; 36(9): 100219, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37201685

RESUMEN

Stimulated Raman histology (SRH) is an ex vivo optical imaging method that enables microscopic examination of fresh tissue intraoperatively. The conventional intraoperative method uses frozen section analysis, which is labor and time intensive, introduces artifacts that limit diagnostic accuracy, and consumes tissue. SRH imaging allows rapid microscopic imaging of fresh tissue, avoids tissue loss, and enables remote telepathology review. This improves access to expert neuropathology consultation in both low- and high-resource practices. We clinically validated SRH by performing a blinded, retrospective two-arm telepathology study to clinically validate SRH for telepathology at our institution. Using surgical specimens from 47 subjects, we generated a data set composed of 47 SRH images and 47 matched whole slide images (WSIs) of formalin-fixed, paraffin-embedded tissue stained with hematoxylin and eosin, with associated intraoperative clinicoradiologic information and structured diagnostic questions. We compared diagnostic concordance between WSI and SRH-rendered diagnoses. Also, we compared the 1-year median turnaround time (TAT) of intraoperative conventional neuropathology frozen sections with prospectively rendered SRH-telepathology TAT. All SRH images were of sufficient quality for diagnostic review. A review of SRH images showed high accuracy in distinguishing glial from nonglial tumors (96.5% SRH vs 98% WSIs) and predicting final diagnosis (85.9% SRH vs 93.1% WSIs). SRH-based diagnosis and WSI-permanent section diagnosis had high concordance (κ = 0.76). The median TAT for prospectively SRH-rendered diagnosis was 3.7 minutes, approximately 10-fold shorter than the median frozen section TAT (31 minutes). The SRH-imaging procedure did not affect ancillary studies. SRH generates diagnostic virtual histologic images with accuracy comparable to conventional hematoxylin and eosin-based methods in a rapid manner. Our study represents the largest and most rigorous clinical validation of SRH to date. It supports the feasibility of implementing SRH as a rapid method for intraoperative diagnosis complementary to conventional pathology laboratory methods.


Asunto(s)
Neoplasias del Sistema Nervioso Central , Telepatología , Humanos , Neoplasias del Sistema Nervioso Central/diagnóstico , Eosina Amarillenta-(YS) , Secciones por Congelación/métodos , Hematoxilina , Microscopía , Estudios Retrospectivos , Telepatología/métodos
2.
Chest ; 159(3): 1265-1272, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33197404

RESUMEN

BACKGROUND: Our previous study revealed that intraoperative frozen section (FS) analysis could differentiate invasive lung adenocarcinoma (LUAD) accurately from preinvasive lesions. However, few articles have analyzed the clinical impact of FS errors such as underestimation of invasive adenocarcinomas (IACs), and whether complementary therapy is needed remains controversial. RESEARCH QUESTION: What is the prognosis of patients undergoing limited resection for invasive LUAD misdiagnosed as atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), or minimally invasive adenocarcinoma (MIA) by intraoperative FS analysis? STUDY DESIGN AND METHODS: From 2012 through 2018, data on 3031 patients undergoing sublobar resection of AAH, AIS, or MIA diagnosed by FS analysis were collected. The concordance rate between FS analysis and final pathologic results was evaluated. To assess the clinical significance of a discrepancy between FS and final pathologic results, patients with final pathologic results of IAC were identified for prognostic evaluation. RESULTS: When AAH, AIS, and MIA were classified together as a group, the overall concordance rate between FS and final pathologic results was 93.7%, and 192 patients (6.3%) received an upgraded diagnosis from the final pathologic results. Misdiagnosed IACs consisted of 94 patients (48.9%) with lepidic-predominant adenocarcinoma, 77 patients (40.1%) with acinar predominant adenocarcinoma, 19 patients (9.9%) with papillary predominant adenocarcinoma, one patient with solid predominant adenocarcinoma, and one patient with invasive mucinous adenocarcinoma. Among these patients, no positive N1 or N2 lymph node findings were observed. Moreover, the 5-year recurrence-free survival was still 100%, although the final pathologic results turned out to be IAC. INTERPRETATION: Patients undergoing limited resection of invasive LUAD misdiagnosed as AAH, AIS, or MIA by FS analysis showed excellent prognoses. Sublobar resection guided by FS diagnosis would be adequate for these underestimated cases of invasive LUAD.


Asunto(s)
Adenocarcinoma del Pulmón , Secciones por Congelación/métodos , Cuidados Intraoperatorios/métodos , Neoplasias Pulmonares , Neumonectomía , Lesiones Precancerosas/diagnóstico , Adenocarcinoma in Situ/diagnóstico , Adenocarcinoma del Pulmón/diagnóstico , Adenocarcinoma del Pulmón/patología , Adenocarcinoma del Pulmón/cirugía , Adenomatosis Pulmonar/diagnóstico , China/epidemiología , Errores Diagnósticos/estadística & datos numéricos , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Neumonectomía/métodos , Neumonectomía/estadística & datos numéricos , Pronóstico , Tomografía Computarizada por Rayos X/métodos
3.
Rapid Commun Mass Spectrom ; 34(9): e8729, 2020 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-31951673

RESUMEN

RATIONALE: A recently developed matrix-free laser desorption/ionization method, DIUTHAME (desorption ionization using through-hole alumina membrane), was examined for the feasibility of mass spectrometry imaging (MSI) applied to frozen tissue sections. The permeation behavior of DIUTHAME is potentially useful for MSI as positional information may not be distorted during the extraction of analytes from a sample. METHODS: The through-hole porous alumina membranes used in the DIUTHAME chips were fabricated by wet anodization, were 5 µm thick, and had the desired values of 200 nm through-hole diameter and 50% open aperture ratio. Mouse brain frozen tissue sections on indium tin oxide (ITO)-coated slides were covered using the DIUTHAME chips and were subjected to MSI experiments in commercial time-of-flight mass spectrometers equipped with solid-state UV lasers after thawing and drying without matrix application. RESULT: Mass spectra and mass images were successfully obtained from the frozen tissue sections using DIUTHAME as the ionization method. The mass spectra contained rich peaks in the phospholipid mass range free from the chemical background owing to there being no matrix-derived peaks in that range. DIUTHAME-MSI delivered high-quality mass images that reflected the anatomy of the brain tissue. CONCLUSIONS: Analytes can be extracted from frozen tissue by capillary action of the through-holes in DIUTHAME and moisture contained in the tissue without distorting positional information of the analytes. The sample preparation for frozen tissue sections in DIUTHAME-MSI is simple, requiring no specialized skills or dedicated apparatus for matrix application. DIUTHAME can facilitate MSI at a low mass, as there is no interference from matrix-derived peaks, and should provide high-quality, reproducible mass images more easily than MALDI-MSI.


Asunto(s)
Química Encefálica , Secciones por Congelación/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Óxido de Aluminio/química , Animales , Secciones por Congelación/instrumentación , Membranas Artificiales , Ratones , Porosidad
4.
Int J Gynecol Cancer ; 30(3): 358-363, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31911532

RESUMEN

INTRODUCTION: Sentinel lymph node (SLN) detection has been shown to be accurate in detecting lymph node involvement in early-stage cervical cancer. The objective of this study was to evaluate the accuracy of frozen section examination in the assessment of SLN status, with the aim of adequately driving the intra-operative decision. METHODS: We designed a retrospective study including patients from two comprehensive cancer centers between January 2001 and December 2018 with early-stage cervical cancer (IA1-IB2 according to International Federation of Gynecology and Obstetrics (FIGO) 2018) undergoing SLN dissection. The SLN procedure was performed using a cervical injection with technetium-99m combined with blue dye or indocyanine green in most cases. RESULTS: A total of 176 patients fulfilled inclusion criteria. Bilateral mapping was detected in 153 (86.7%) of them. Nineteen of these patients (12.4%) had SLN involvement: 13 with macrometastases, three with micrometastases and three with isolated tumor cells (ITC). Macrometastatic disease was missed on frozen section in 3/13 FIGO 2018 stage IIIC patients. The three patients with ITC were also missed by frozen section examination.Considering only macrometastases as lymph node involvement, frozen section sensitivity was 76.9% (95% CI 49.7 to 91.8) and negative predictive value (NPV) was 97.9% (95% CI 94.0 to 99.3) in patients with bilateral detection. Including micrometastases, sensitivity was 81.2% (95% CI 57.0 to 93.4) and NPV remained at 97.9% (95% CI 93.9 to 99.3). CONCLUSIONS: With a prevalence of final-stage IIIC in patients with pre-operative early-stage cervical cancer of the order of 10% in this series, the NPV of frozen section examination of SLN is very high, with an inferior limit of the CI superior to 94%. Diagnostic accuracy remains acceptable even if micrometastases are considered. The impact of missed ITC has not been established. Frozen section examination can be incorporated in the intra-operative decision algorithm.


Asunto(s)
Secciones por Congelación/métodos , Ganglio Linfático Centinela/patología , Neoplasias del Cuello Uterino/patología , Neoplasias del Cuello Uterino/cirugía , Adulto , Algoritmos , Toma de Decisiones , Femenino , Humanos , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía , Metástasis Linfática , Estadificación de Neoplasias , Estudios Retrospectivos , Ganglio Linfático Centinela/cirugía , Biopsia del Ganglio Linfático Centinela/métodos
5.
BMC Cancer ; 11: 157, 2011 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-21529381

RESUMEN

BACKGROUND: The purpose of this study was to assess the feasibility and accuracy of sentinel lymph nodes (SLNs) detection using 99mTc phytate in predicting pelvic lymph nodes status for radical abdominal trachelectomy (RAT) in patients with early stage cervical cancer. METHODS: Sixty-eight women with stage IA2-IB1 cervical cancer and scheduled to undergo fertility-sparing surgery enrolled in this study. 99mTc-labeled phytate was injected before surgery. Intraoperatively, SLNs were identified, excised, and submitted to fast frozen section. Systematic bilateral pelvic lymphadenectomy and/or para-aortic lymph node dissection was performed. Then RAT was performed in patients with negative SLNs. All nodes were sent for routine pathological examination and immunostained with anti-cytokeratin antibody to detect micrometastases. Outcomes of follow up and fertility were observed. RESULTS: SLNs were identified in 64 of 68 patients (94.1%). Of these, SLNs of 8 patients (11.8%) were positive on frozen sections and proved to be metastasis by final pathologic examination. The sensitivity, accuracy, and false negative rates were 100%, 100%, and 0%, respectively. All 60 patients with negative SLN underwent RAT successfully. Two relapses occurred and no one died of tumor progression during follow-up. Five of the 15 patients with procreative desire conceived 8 pregnancies (3 term delivery, 2 premature birth, 1 spontaneous abortion, and 2 were still in the duration of pregnancy) after surgery. CONCLUSIONS: The identification of SLN using 99mTc-labeled phytate is accurate and safe to assess pelvic nodes status in patients with early cervical cancer. SLNs biopsy guided RAT is feasible for patients who desire to have fertility preservation.


Asunto(s)
Ganglios Linfáticos/cirugía , Biopsia del Ganglio Linfático Centinela/métodos , Neoplasias del Cuello Uterino/cirugía , Adulto , Quimioterapia Adyuvante , Femenino , Secciones por Congelación/métodos , Humanos , Escisión del Ganglio Linfático/métodos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Metástasis Linfática , Estadificación de Neoplasias , Compuestos de Organotecnecio , Pelvis/patología , Pelvis/cirugía , Ácido Fítico , Cintigrafía , Radiofármacos , Resultado del Tratamiento , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/tratamiento farmacológico , Neoplasias del Cuello Uterino/patología
6.
J Struct Biol ; 110(3): 244-55, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8373705

RESUMEN

Freeze-dried, ultrathin cryosections of directly frozen mouse liver and brain have been prepared and characterized by low-dose dark-field scanning transmission electron microscopy (STEM). These improved cryosections gave images comparable to those from conventional plastic sections. They were thin enough (< < 1.0 elastic mean free path) to use established dark-field techniques, modified for thickness-dependent nonlinearities, to measure the dry mass fraction of individual organelles, and hence to deduce their water content. Digital STEM imaging in combination with electron and X-ray spectroscopy has important biological applications, as illustrated by studies on calcium regulation in Purkinje neurons. Calcium concentrations per unit dry weight of dendritic compartments were determined by the peak/continuum method of energy-dispersive X-ray spectroscopy (EDXS), which necessarily overstates elemental concentrations because of beam-induced mass loss. The dry mass content of organelles at low dose and the percentage of dry mass retained after analysis at high dose were as follows: mitochondria (46.0 g dry mass/100 g hydrated mass, 67% mass retained); endoplasmic reticulum (27.9 g/100 g, 57%); and cytoplasm (16.3 g/100 g, 41%). These values were used to correct elemental concentrations for mass loss. Results indicated that the major calcium storage organelle in Purkinje cell dendrites is the endoplasmic reticulum, of which there are two types distinguished by their levels of calcium. Parallel electron energy loss spectroscopy of dendritic organelles corroborated EDXS measurements, with an improved sensitivity that indicates the feasibility of quantitative calcium mapping.


Asunto(s)
Corteza Cerebelosa/ultraestructura , Secciones por Congelación/métodos , Hígado/ultraestructura , Microscopía Electrónica de Transmisión de Rastreo/métodos , Animales , Calcio/análisis , Corteza Cerebelosa/química , Estudios de Evaluación como Asunto , Hígado/química , Ratones , Ratones Endogámicos C57BL , Orgánulos/química , Orgánulos/ultraestructura , Células de Purkinje/química , Células de Purkinje/ultraestructura , Fracciones Subcelulares/química , Fracciones Subcelulares/ultraestructura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA