Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Surgery ; 164(5): 965-971, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30054014

RESUMEN

BACKGROUND: Neck discomfort and voice change are common complications after thyroidectomy. These symptoms might be due to damaged laryngeal nerves, intrinsic structures, or extralaryngeal muscles. They can also occur without injury to any structure as with wound adhesion after thyroidectomy. The objective of this study was to determine causes of neck discomfort and voice change after thyroidectomy and to evaluate the effect of wound massage on symptom relief. METHODS: Forty-five female patients who underwent total thyroidectomy were included (21 in the experimental group and 24 in the control group). Wound massage was used as an intervention to release surgical adhesion. After wound massage education, participants in the experimental group received wound massage from 4 to 12 weeks after thyroidectomy. Analysis was performed for both groups. RESULTS: No laryngeal pathology was found after thyroidectomy. The experimental group had significantly better recovery from surgical adhesion and subjective visual analog scale, voice impairment score, and swallowing impairment score (all P < .01) compared with the control group. Voice analysis results associated with laryngeal movement (speaking fundamental frequency, voice range profile maximum, voice range profile range) also indicated significant recovery (P < .01) in the experimental group. These results indicate that local adhesion after thyroidectomy might affect general movement of the larynx and that wound massage could help patients recover normal general movement of the larynx. CONCLUSION: Neck discomfort and voice change after thyroidectomy are related to local wound adhesion, possibly associated with impairment of laryngeal vertical movement. Release of wound adhesion could help patients recover from neck discomfort and voice changes after thyroidectomy.


Asunto(s)
Traumatismos del Nervio Laríngeo/terapia , Masaje/métodos , Complicaciones Posoperatorias/terapia , Herida Quirúrgica/terapia , Neoplasias de la Tiroides/cirugía , Tiroidectomía/efectos adversos , Estudios de Casos y Controles , Femenino , Humanos , Traumatismos del Nervio Laríngeo/etiología , Traumatismos del Nervio Laríngeo/fisiopatología , Laringoscopía/instrumentación , Laringoscopía/métodos , Persona de Mediana Edad , Cuello/fisiopatología , Cuello/cirugía , Cooperación del Paciente/estadística & datos numéricos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Autocuidado/métodos , Herida Quirúrgica/complicaciones , Herida Quirúrgica/fisiopatología , Tiroidectomía/instrumentación , Tiroidectomía/métodos , Adherencias Tisulares/etiología , Adherencias Tisulares/terapia , Resultado del Tratamiento , Pliegues Vocales/diagnóstico por imagen , Pliegues Vocales/fisiopatología , Voz/fisiología
2.
Int J Surg ; 48: 155-159, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29100907

RESUMEN

BACKGROUND: Recently, several energy-based devices (EBDs) have been developed and applied in the context of thyroid surgery. EBDs can reduce operation time, blood loss, and postoperative pain. Compared to conventional electrocautery, EBDs operate at a relatively lower temperature and produce minimal lateral tissue damage. Yet, during device operation, the tip of the EBD is hot enough to cause thermal nerve damage, increasing the need for surgeons to be cautious about EBD application. To increase the safety of EBDs, we attached nerve stimulators to the tips of two EBDs and compared them to conventional monopolar nerve stimulation using a porcine model. METHODS: Three piglets (30-40 kg) underwent total thyroidectomy after orotracheal intubation with a nerve integrity monitor (NIM) electromyography (EMG) endotracheal tube. Nerve stimulators were attached to two EBDs (Harmonic Focus®+ and LigaSure™). After dissection and identification of six recurrent laryngeal nerves in the three piglets, both of the EBDs with attached nerve stimulators and a conventional monopolar nerve stimulator were applied near the nerve and EMG parameters were recorded using the NIM 3.0 system. The stimulus intensity was varied from 5 mA to 1 mA and the maximum distance and amplitude at which nerve detection was achieved were measured. RESULTS: There were no statistically significant differences between the maximum distance or mean amplitude obtained from nerve stimulators attached to EBDs and those obtained from the conventional nerve stimulator. Additionally, there were no adverse EMG events related to the use of nerve stimulators attached to EBDs. CONCLUSIONS: Attachment of a nerve stimulator to an EBD for nerve detection during thyroidectomy was as safe and effective as attachment of a conventional nerve stimulator. Use of a nerve stimulator attachment may reduce the likelihood of EBD-associated nerve damage during thyroid surgery.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Electromiografía/métodos , Intubación Intratraqueal/instrumentación , Monitoreo Intraoperatorio/instrumentación , Tiroidectomía/instrumentación , Animales , Disección , Terapia por Estimulación Eléctrica/métodos , Diseño de Equipo , Estudios de Factibilidad , Complicaciones Intraoperatorias/etiología , Complicaciones Intraoperatorias/prevención & control , Monitoreo Intraoperatorio/métodos , Monitoreo Fisiológico , Nervio Laríngeo Recurrente/fisiología , Nervio Laríngeo Recurrente/cirugía , Traumatismos del Nervio Laríngeo Recurrente/etiología , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Porcinos , Glándula Tiroides/cirugía , Tiroidectomía/efectos adversos , Tiroidectomía/métodos
3.
Otolaryngol Head Neck Surg ; 150(6): 943-8, 2014 06.
Artículo en Inglés | MEDLINE | ID: mdl-24671461

RESUMEN

OBJECTIVES: LigaSure Small Jaw(®) (LSJ) was recently developed and applied to thyroid surgery along with Harmonic Focus(®) (HF). We compared the 2 devices in open total thyroidectomy for papillary thyroid carcinoma (PTC). STUDY DESIGN: A prospective, randomized study. SETTING: Tertiary care center. METHODS: This prospective, randomized study included 126 patients enrolled between December 2011 and June 2012. The numbers of patients in the LSJ group and the HF group were 64 and 62, respectively. Operative times, drain output, parathyroid status, complications, laboratory data, hospital stay, and analgesia requirements were analyzed. RESULTS: Operation time, parathyroid status, postoperative complications including hypocalcemia, oral calcium supplement, calcium, parathyroid hormone, usage count of painkiller, and hospital stay were not different among the 2 groups. Ionized calcium on postoperative days 1, 2, and 10 was higher in the LSJ group (P = .04, P = .04, P = .01), and drain output was lower in the LSJ group (106.8 vs 123.6 mL, P = .01). CONCLUSIONS: Open thyroidectomy for PTC using the HF or the LSJ was safe and effective and was not associated with any increase in complications. Surgical outcomes and operative morbidity were equivalent between the 2 groups.


Asunto(s)
Hemostasis Quirúrgica/instrumentación , Neoplasias de la Tiroides/cirugía , Tiroidectomía/instrumentación , Procedimientos Quirúrgicos Ultrasónicos/instrumentación , Femenino , Humanos , Tiempo de Internación , Ligadura/instrumentación , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Resultado del Tratamiento
4.
Head Neck ; 35(4): 562-7, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22715020

RESUMEN

BACKGROUND: Options for controlling hemostasis during thyroidectomy include bipolar vessel sealing system and ultrasonic technology. The purpose of this study was to compare these energy-based devices on the performance of open thyroidectomy for benign disease with emphasis given to postoperative parathyroid function. METHODS: Among the available energy-based devices, the LigaSure Precise (LP; Valleylab, Boulder, CO) and FOCUS Shears (FS; Ethicon Endo-Surgery, Cincinnati, OH) were evaluated. One hundred ninety-nine consecutive patients scheduled for open thyroidectomy were prospectively randomized into 2 similar-sized groups. Operative time, morbidity, incision length, postoperative pain, and hospital stay were analyzed. Postoperative hypoparathyroidism was monitored with serial determinations of intact parathyroid hormone (iPTH) and serum calcium. RESULTS: Early postoperative measurement of iPTH plasma level, although within the reference range, was significantly lower in the FS group (p < .001). Oral calcium supplementation was significantly higher and prolonged in the FS group. CONCLUSION: The present study demonstrates a significant difference of the rates for postoperative parathyroid malfunction when using different energy-based devices.


Asunto(s)
Hemostasis Quirúrgica/instrumentación , Hipoparatiroidismo/etiología , Glándulas Paratiroides/cirugía , Hormona Paratiroidea/sangre , Complicaciones Posoperatorias/etiología , Tiroidectomía/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Pérdida de Sangre Quirúrgica , Calcio/sangre , Femenino , Humanos , Hipoparatiroidismo/epidemiología , Ligadura/instrumentación , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Resultado del Tratamiento , Adulto Joven
5.
Langenbecks Arch Surg ; 397(5): 817-23, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22230963

RESUMEN

PURPOSE: The options for haemostasis and dissection during modern thyroid surgery include the use of a bipolar vessel sealing system and ultrasonic technology. The aim of this study was to compare these energy-based devices (EBDs) with respect to their use in open thyroidectomy. METHODS: The FOCUS Shear (F) and LigaSure LF1212 (L) were evaluated. A total of 182 consecutive patients scheduled for open thyroidectomy were prospectively randomised into two similarly sized groups. The parameters of operative time, morbidity, incision length, postoperative pain and hospital stay were analysed. RESULTS: The main clinically primary endpoints of the two devices were identical in the study as the rate of nerve lesions, bleeding, drainage, operative time and postoperative calcium concentration with no significant differences with respect to the instrument utilised. The mean length of the incision was greater in the F group (p < 0.05). Patients in the F group were more likely to complain of pain while swallowing (p < 0.001). Early postoperative measurements of intact parathyroid hormone plasma levels revealed that although the levels were within the reference range, they were significantly lower in the F group (p < 0.001). Oral calcium supplementation was significantly higher and more prolonged in the F group. CONCLUSIONS: The present study demonstrated no significant difference in the rates of postoperative morbidity associated with these two different EBDs used. Differences in clinically less significant were founded and focused on.


Asunto(s)
Pérdida de Sangre Quirúrgica/prevención & control , Hemostasis Quirúrgica/instrumentación , Instrumentos Quirúrgicos , Neoplasias de la Tiroides/cirugía , Tiroidectomía/instrumentación , Adulto , Anciano , Diseño de Equipo , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Humanos , Ligadura/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Neoplasias de la Tiroides/mortalidad , Neoplasias de la Tiroides/patología , Tiroidectomía/métodos , Resultado del Tratamiento , Adulto Joven
6.
J Laparoendosc Adv Surg Tech A ; 15(6): 647-52, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16366877

RESUMEN

PURPOSE: To demonstrate the utility of robotically assisted approaches in head and neck surgery. MATERIALS AND METHODS: Two teenage patients, one with a solitary thyroid nodule who was scheduled for a right thyroid lobectomy and the other with intractable seizures who was scheduled for placement of a vagal nerve stimulator were offered the option of a robotically assisted technique using a transaxillary endoscopic approach. RESULTS: Both procedures were completed successfully using the da Vinci surgical system (Intuitive Surgical, Sunnyvale, California). A 12 mm telescope and 5 mm instruments were used. There was sufficient mobility of the robotic arms despite the small working space. There were no complications, minimal pain in the axillary incisions, and patient satisfaction was high. Operative times were 4.5 and 4.2 hours, respectively. CONCLUSION: Transaxillary, endoscopic, robotically assisted approaches to the head and neck are feasible. The addition of robotics improves surgical dexterity in a difficult-to-reach anatomic region. Patient satisfaction appears high because of the avoidance of a cervical incision.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Robótica/instrumentación , Convulsiones/terapia , Tiroidectomía/instrumentación , Nervio Vago , Adolescente , Adulto , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA