Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

Medicinas Complementárias
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Zhonghua Yan Ke Za Zhi ; 60(4): 330-336, 2024 Apr 11.
Artículo en Chino | MEDLINE | ID: mdl-38583056

RESUMEN

Objective: To investigate the influence of corneal e-value on the effectiveness of orthokeratology in controlling myopia in children and adolescents. Methods: A retrospective cohort study was conducted, involving the data from 1 563 myopic patients (1 563 eyes) who underwent orthokeratology at the Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine from June 2015 to August 2021 and adhered to lens wear for at least 2 years. The cohort consisted of 737 males and 826 females with an average age of (10.84±2.13) years. Based on corneal e-value parameters obtained from corneal topography, patients were categorized into a low e-value group (n=425) and a high e-value group (n=1 138). Data on gender, age, parental myopia history, and baseline measures such as spherical equivalent (SE), axial length, and corneal e-value were collected. Differences in axial length change and corneal fluorescein staining rates were compared between the two groups at 1 and 2 years after the start of lens wear. A generalized linear mixed model was established with axial length change as the dependent variable to analyze the correlation between axial length change and baseline corneal e-value. Results: The initial age of the 1 563 myopic patients was (10.84±2.13) years, with a baseline SE of (-3.05±1.30) D. After 1 year of lens wear, the axial length change was (0.20±0.19) mm in the low e-value group and (0.24±0.20) mm in the high e-value group. After 2 years, the changes were (0.38±0.25) mm and (0.43±0.27) mm, respectively, with statistically significant differences (all P<0.05). The incidence of corneal staining after 1 year of lens wear was 9.2% (39/425) in the low e-value group and 14.1% (160/1 138) in the high e-value group. After 2 years, the rates were 15.8% (67/425) and 21.8% (248/1 138), respectively, with statistically significant differences (all P<0.05). After adjusting for parental myopia history, age, SE, and baseline axial length, the baseline corneal e-value was positively correlated with axial length change at 1 and 2 years after lens wear (all P<0.05). Conclusions: Corneal e-value is an independent factor influencing the effectiveness of orthokeratology in controlling myopia. A smaller corneal e-value is associated with slower axial length growth after orthokeratology, indicating better control of myopia in treated eyes.


Asunto(s)
Lentes de Contacto , Miopía , Procedimientos de Ortoqueratología , Masculino , Femenino , Niño , Humanos , Adolescente , Estudios Retrospectivos , Longitud Axial del Ojo , Miopía/terapia , Topografía de la Córnea , Refracción Ocular
2.
J Cataract Refract Surg ; 50(3): 209-216, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38381615

RESUMEN

PURPOSE: To investigate the effects of customized topography-guided epithelium-on crosslinking (epi-on CXL) with oxygen supplementation on procedural efficacy and corrected distance visual acuity (CDVA) in patients with progressive keratoconus (KC) at 1 year. SETTING: Private eye clinic, Brisbane, Australia. DESIGN: Retrospective, single-center, nonrandomized case series. METHODS: Topography-guided epi-on CXL using the Mosaic system was performed on patients with progressive KC. Oxygen goggles; transepithelial riboflavin; and pulsed, high UV-A irradiance (1 second on, 1 second off; 30 mW/cm2) were applied to enhance oxygen kinetics and bioavailabilities of riboflavin and UV-A. Guided by baseline topography, a higher UV-A dose (15 J/cm2) was applied to the area of steepest anterior curvature with decreasing fluence (as low as 7.2 J/cm2) toward the outer 9 mm. Postoperative CDVA and maximum keratometry (Kmax) were evaluated. RESULTS: 102 eyes (80 patients) were followed for 11.5 ± 4.8 months. At the latest follow-up, mean CDVA (logMAR), mean K, and Kmax (diopters [D]) improved from 0.18 ± 0.28, 46.2 ± 3.8, and 53.0 ± 5.67 at baseline to 0.07 ± 0.18, 45.8 ± 3.7, and 51.9 ± 5.56, respectively (P < .001). 3 eyes (3%) lost more than 1 CDVA line, and another 3 eyes (3%) had increased Kmax greater than 2 D. 43 eyes were followed for at least 12 months (n = 43): mean CDVA, mean K, and Kmax improved from 0.19 ± 0.33 logMAR, 46.5 ± 3.5 D, and 53.6 ± 5.67 D to 0.07 ± 0.17 logMAR, 46.0 ± 3.5 D, and 52.33 ± 5.49 D, respectively (P ≤ .002). No complications were observed. CONCLUSIONS: Tailoring oxygen-supplemented epi-on CXL with differential UV-A energy distributions, guided by baseline topography, in patients with KC seems to be safe and effective. At 1 year, study reports sustained improved CDVA and corneal stabilization.


Asunto(s)
Queratocono , Fotoquimioterapia , Humanos , Queratocono/tratamiento farmacológico , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Retrospectivos , Rayos Ultravioleta , Sustancia Propia , Topografía de la Córnea , Estudios de Seguimiento , Paquimetría Corneal , Reactivos de Enlaces Cruzados/uso terapéutico , Riboflavina/uso terapéutico , Epitelio
3.
Am J Ophthalmol ; 256: 175-185, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37669730

RESUMEN

PURPOSE: To define the external scleral sulcus (ESS) on a Scheimpflug image and use it for a morphometric analysis of corneal diameter (CD). DESIGN: Retrospective, cross-sectional study of pediatric Asian-Indian eyes. METHODS: One random eye of 353 subjects between 5 and 18 years underwent 25-scan Pentacam HR imaging. For all scans, densitometry values along the anterior corneal edge were recorded and differentiated. The peaks on the differentiated curve were chosen as the ESS points, and this distance between them was called CD. Vertical (vCD), maximum (maxCD), minimum (minCD) CD and their meridians were defined. Multiple regression models (MRMs) with CD and other Pentacam parameters were built to predict astigmatism and its axis, mean keratometry (Kmean), and Belin/Ambrósio enhanced ectasia display deviation (BAD-D). MRMs were validated using intraclass correlation coefficient (ICC). Estimated horizontal CD (hCD) was validated against digital caliper measurement using ICC. RESULTS: The ICC (95% CI) between caliper and hCD was 0.96 (0.93, 0.97). MRM predictions (P < .001) used CD parameters, anterior chamber depth, corneal volume and distance from the corneal thinnest location to apex. These predictions achieved an ICC of 0.34 (0.18, 0.46), 0.82 (0.78, 0.86), 0.87 (0.84, 0.89), and 0.81 (0.76, 0.84), respectively. The astigmatism axis prediction depended on the minCD and maxCD meridians. Its within-subject SD (4.97°) was less than 2 consecutive Pentacam scan angles (7.2°). CONCLUSIONS: The CD metric strongly correlated with the astigmatism axis, keratometry, and BAD-D. Its spatial description may be significant in corneal treatment planning and disease diagnoses.


Asunto(s)
Astigmatismo , Meridianos , Humanos , Niño , Topografía de la Córnea/métodos , Estudios Retrospectivos , Astigmatismo/diagnóstico , Estudios Transversales , Córnea/diagnóstico por imagen
4.
Int Ophthalmol ; 43(10): 3733-3745, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37389763

RESUMEN

PURPOSE: To evaluate the efficacy and safety of transepithelial accelerated crosslinking (TE-ACXL) using pulsed light and supplemental oxygen. METHODS: Thirty eyes of 30 consecutive patients with progressive keratoconus or post-LASIK ectasia were enrolled in a prospective non-comparative study conducted at the Magrabi Eye Center (Jeddah, Saudi Arabia). All eyes underwent TE-ACXL with supplemental oxygen. Primary outcome measures were the mean change in corrected distance visual acuity (CDVA) (logMAR) and maximum keratometry (max K) from preoperatively to 12 months postoperatively. Secondary outcome measures included change in manifest refractive spherical equivalent (MRSE), refractive cylinder, keratometry, symmetry index (SI), center-surrounding index (CSI) and ectasia index (EI) of the anterior and posterior corneal surfaces, corneal and epithelial thickness at corneal vertex and thinnest location, corneal densitometry, corneal high order aberrations (HOA) and endothelial cell density (ECD). RESULTS: Mean age was 29.6 ± 8.2 years. At 1 year, the follow up rate was 93.3%. CDVA improved statistically significantly at 12 months (p = 0.027). Measures of corneal keratometry or pachymetry did not change significantly (p < 0.05). Postoperatively, a demarcation line was documented in 78.6% eyes at 1 month, and in 12 (42.9%) eyes at 12 months. The mean depth of the demarcation line was 341.9 ± 49.4 µm. Corneal densitometry increased significantly at 1- and 3-months (p < 0.05) and returned to normal levels at 6- and 12-months postoperatively. CONCLUSION: TE-ACXL with oxygen supplement is effective at halting the progression of corneal ectasia for at least 1 year and can be a refractive neutral procedure.


Asunto(s)
Queratocono , Fármacos Fotosensibilizantes , Humanos , Adulto Joven , Adulto , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Dilatación Patológica/metabolismo , Estudios Prospectivos , Sustancia Propia/metabolismo , Rayos Ultravioleta , Topografía de la Córnea , Paquimetría Corneal , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Reactivos de Enlaces Cruzados/uso terapéutico
5.
Acta Ophthalmol ; 101(3): e315-e326, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36245315

RESUMEN

PURPOSE: The purpose of the study was to assess the efficacy of electroacupuncture on dry eye (DE). METHODS: Eighty-four DE patients were randomly assigned to receive electroacupuncture (EAG) three times a week or 0.1% sodium hyaluronate artificial tears (ATG) four times per day for 4 weeks. The primary outcomes were non-invasive tear film breakup time (NIBUT) and tear meniscus height (TMH). The secondary outcomes included the ocular surface disease index (OSDI), Schirmer I test (SIT), corneal sodium fluorescein staining (CFS) score, corneal topography descriptors surface asymmetry index (SAI) and surface regularity index (SRI), corneal sensitivity, 36-item Short-form Health Survey (SF-36) score and Hospital Anxiety and Depression Scale (HADS) score. All outcomes were assessed at Week 0 (baseline), Week 4 (after-treatment) and Week 8 (follow-up). RESULTS: Between-group comparisons showed significant differences in the changes in NIBUT (Week 4, p = 0.003; Week 8, p = 0.008), TMH (Week 4, p = 0.014; Week 8, p = 0.009), OSDI (Week 4, p = 0.029; Week 8, p = 0.022), CFS score (Week 8, p = 0.036) and SF-36 role-physical score (Week 4, p = 0.010), favouring EAG. Mean changes in SIT, SAI, SRI, corneal sensitivity and HADS scores were statistically equal between the two groups (all p > 0.05). Treatment with electroacupuncture was well-tolerated and showed minimal adverse events. CONCLUSIONS: Compared with artificial tears, electroacupuncture shows superior efficacy in improving tear film stability and symptoms of DE.


Asunto(s)
Síndromes de Ojo Seco , Electroacupuntura , Humanos , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/terapia , Gotas Lubricantes para Ojos , Proyectos Piloto , Topografía de la Córnea
6.
Rev. bras. oftalmol ; 82: e0016, 2023. graf
Artículo en Portugués | LILACS | ID: biblio-1431669

RESUMEN

RESUMO Objetivo: Analisar retrospectivamente as alterações na ceratometria e no astigmatismo corneano obtidas após cirurgia de implante de anel intraestromal, comparando o uso de um segmento de arco longo versus o implante de dois segmentos de comprimento de arco tradicional. Métodos: A partir de um estudo transversal, obtivemos os dados de 94 olhos de pacientes diagnosticados com ceratocone, que foram submetidos ao implante de anel corneano. Eles foram divididos em dois grupos, dependendo do tipo de implante recebido: Grupo A, um segmento de arco longo; Grupo B, dois segmentos tradicionais. Todos os segmentos implantados possuíam 250µ de espessura. Os dados do pré-operatório dos dois grupos foram comparados, para garantir que as amostras eram similares (as diferenças encontradas entre os dois grupos não eram estatisticamente significativas). As variáveis analisadas no pré e no pós-operatório foram acuidade visual com correção, ceratometria, astigmatismo corneano e refração. Resultados: A amostra que recebeu apenas um segmento de arco longo (Grupo A) obteve redução da ceratometria média de 4,42D (8,7%) e do astigmatismo corneano de 2,43D (40,4%). Já na amostra dos olhos que receberam dois segmentos de arco tradicional (Grupo B), houve redução média de 2,66D (5,1%) em relação à ceratometria média e redução média de 2,11D (34,8%) em relação ao astigmatismo corneano. A redução obtida na ceratometria média no Grupo A foi maior que a obtida no Grupo B (diferença estatisticamente significativa). A redução obtida no astigmatismo do Grupo A não foi estatisticamente significante, se comparada com o resultado obtido no Grupo B (considerando p≤0,05). Conclusão: Foi demonstrado que o uso de um segmento de arco longo possui maior capacidade de aplanação corneana, se comparado com o uso de dois segmentos com comprimento de arco tradicional. Em relação à redução do astigmatismo, os dois grupos mostraram resultados equivalentes.


ABSTRACT Purpose: To retrospectively analyze the changes in corneal keratometry and astigmatism after intrastromal ring surgery, comparing the use of one long arch segment versus two traditional arc length segments. Methods: A cross-sectional study obtained data from 94 eyes of patients diagnosed with keratoconus that underwent surgical treatment with corneal ring implant. They were divided into two groups according to the type of implant received: one long-arch segment (Group A) or two traditional segments (Group B), both 250 microns thick. Preoperative data from the two groups were compared to ensure that the samples were similar (the differences between the two groups were not statistically significant). The variables (pre and post-operatively) analyzed were: best corrected visual acuity, keratometry, corneal astigmatism and refraction. Results: Group A, which received one long arch segment, showed a Km decrease of 4.42D (8.7%) and a corneal astigmatism reduction of 2.43D (40.4%). Group B, where the eyes acquired two traditional arch segments, showed an average Km decrease of 2.66D (5.1%) and corneal astigmatism reduction of 2.11D (34.8%). The mean keratometry (Km) reduction obtained was statistically significant (p≤0.05) when comparing both groups (A and B). The mean corneal astigmatism reduction was not statistically significant (p≤0.05) when comparing both groups (A and B). Conclusions: One long-arch segment has been demonstrated to have a greater capacity to reduce corneal curvature when compared to the use of two traditional-sized arch segments. No significant differences were found regarding the reduction of corneal astigmatism after comparing the results obtained in both groups.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Adulto , Persona de Mediana Edad , Prótesis e Implantes , Sustancia Propia/cirugía , Implantación de Prótesis/métodos , Queratocono/cirugía , Refracción Ocular , Astigmatismo , Agudeza Visual , Estudios Transversales , Resultado del Tratamiento , Topografía de la Córnea , Paquimetría Corneal
7.
Transl Vis Sci Technol ; 11(12): 16, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36580321

RESUMEN

Purpose: To evaluate the impact of vitamin D (Vit D) supplementation on systemic biomarkers of collagen degradation, inflammation, oxidative stress, and copper metabolism in adolescent patients with keratoconus (KC). Methods: This was a prospective observational pilot study. Twenty patients (age range, 16-19 years) presenting KC and Vit D insufficiency (<30 ng/mL) were included. Vit D supplementation was prescribed by their general practitioner as per the standard of care. Patients were followed up for 12 months. At each visit, best spectacle-corrected visual acuity (BSCVA), maximal keratometry (Kmax), and thinnest corneal thickness (TCT) were evaluated. The primary outcome of the study was the proportion of patients with Kmax progression of less than 1 D throughout the 12-month follow-up time. Blood samples were collected at different time points to evaluate Vit D levels and systemic markers of collagen degradation, inflammation, oxidative stress, and copper metabolism by ELISA or RT-PCR. Results: Lower Vit D levels in the plasma were correlated with higher levels of systemic biomarkers of collagen degradation. Vit D supplementation increased the cell availability of copper. Moreover, stabilization of KC progression was found in 60% of patients (72% of eyes) after 12 months with Vit D supplementation. BSCVA, Kmax, and TCT rates remained stable during the observation period. Conclusions: Our findings support that Vit D administration could affect ocular and systemic biomarkers in KC and illuminate a possible mechanism that can be used to develop new treatment alternatives. Translational Relevance: Although KC therapy currently relies exclusively on surgical procedures, Vit D supplementation may offer a non-invasive and inexpensive alternative with minimal associated side effects.


Asunto(s)
Queratocono , Fotoquimioterapia , Adolescente , Humanos , Adulto Joven , Adulto , Queratocono/tratamiento farmacológico , Queratocono/metabolismo , Fármacos Fotosensibilizantes , Fotoquimioterapia/métodos , Cobre/uso terapéutico , Agudeza Visual , Rayos Ultravioleta , Riboflavina , Estudios Prospectivos , Estudios de Seguimiento , Topografía de la Córnea , Colágeno , Inflamación , Vitamina D/uso terapéutico , Suplementos Dietéticos
8.
J Cataract Refract Surg ; 48(10): 1175-1182, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35383648

RESUMEN

PURPOSE: To investigate the effects of combining oxygen supplementation with enhanced UV-A light and increased riboflavin permeability in improving the efficacy of epithelium-on crosslinking (epi-on CXL). SETTING: Private eye clinic in Brisbane, Queensland, Australia. DESIGN: Retrospective single-center nonrandomized uncontrolled longitudinal cohort case series. METHODS: Transepithelial CXL was performed on keratoconic eyes. Applications of an oxygen goggle and pulsed UV-A irradiation (1 second on, 1 second off) were used to enhance oxygen kinetics during epi-on CXL. Additional procedural modifications included the use of benzalkonium chloride and high UV-A irradiance level (30 mW/cm 2 ) to improve the stromal bioavailability of riboflavin and UV-A. The main efficacy outcomes were the changes in mean corrected distance visual acuity (CDVA) and safety over 12 months. Additional refractive and keratometry (K) outcomes were also observed. RESULTS: 53 eyes (38 patients) were included in this study. 12 months postoperatively, mean CDVA improved from a mean of 0.18 ± 0.2 at baseline to 0.07 ± 0.1 logMAR ( P < .0001). No statistically significant change was observed in maximum K (Kmax) and mean K, which were respectively 51.7 ± 5.8 diopters (D) and 46.4 ± 3.85 D at baseline and 51.2 ± 5.7 D ( P = .152) and 46.0 ± 3.84 D ( P = .06) 12 months postoperatively. Only 3 eyes experienced an increase of more than 2 D in Kmax; however, none of these eyes experienced a CDVA loss. There were no reported infections, corneal scarring, or other severe adverse effects. CONCLUSIONS: Performing supplemental oxygen epi-on CXL with accelerated, pulsed UV-A irradiation in conjunction with riboflavin permeability enhancers resulted in improved CDVA ( P < .0001) and stable keratometry up to 12 months postoperatively with a good safety profile.


Asunto(s)
Queratocono , Fotoquimioterapia , Compuestos de Benzalconio/uso terapéutico , Colágeno/uso terapéutico , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Queratocono/tratamiento farmacológico , Oxígeno/uso terapéutico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Estudios Retrospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta
10.
Middle East Afr J Ophthalmol ; 29(4): 190-195, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-38162570

RESUMEN

PURPOSE: To compare efficacy and safety between the two modes of energy delivery-pulsed and continuous, in accelerated corneal collagen cross-linking (KXL) to stop the keratoconus advancement through topographical, visual, and refractive endpoints. METHODS: It was a prospective, comparative, randomized, interventional trial. Patients with bilateral progressive keratoconus were subjected to pulsed mode KXL (P-KXL) in the right and continuous mode KXL (C-KXL) treatment in the left eye. In both methods, additional supplemental oxygen was delivered to corneal surface using a nasal cannula connected to an oxygen supply. Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity, posttreatment manifest spherical equivalent and astigmatism, and corneal topography were studied. The deformation amplitude index (DAI) was measured by Corvis-ST. Postoperative follow-up was done. RESULTS: One hundred eyes of 50 patients underwent P-KXL in the right eye and C-KXL in the left eye. The average follow-up was 12.1 ± 1.2 months. At 1 year posttreatment, the UDVA had a mean change of 0.11 ± 0.14 logMAR in P-KXL and 0.18 ± 0.14 logMAR in C-KXL groups. The line of demarcation was observed at 251.13 ± 18.28 µ and 245.28 ± 28.26 µ deep, respectively, in P-KXL- and C-KXL-treated eyes at 6 months' follow-up. The DAI as measured by Corvis-ST showed a significant decrease from pretreatment values of 1.12 ± 0.13 mm to 0.84 ± 0.14 mm (P < 0.01) in P-KXL eyes and from 1.04 ± 0.14 mm to 0.85 ± 0.15 mm (P = 0.03) in C-KXL eyes. Both the groups did not show any statistically significant endothelial cell loss posttreatment. CONCLUSION: C-KXL can give similar functional outcomes as P-KXL with the help of supplemental oxygen delivery with the added advantage of a shortened procedure time in comparison to pulsed mode.


Asunto(s)
Queratocono , Humanos , Reticulación Corneal , Sustancia Propia , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Oxígeno/uso terapéutico , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta
11.
BMC Ophthalmol ; 21(1): 373, 2021 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-34666720

RESUMEN

BACKGROUND: This study aimed to compare surgically induced astigmatism (SIA) on the anterior and total cornea during cataract surgery through a 2.2 mm steep meridian incision. METHODS: The study included 69 left eyes of 69 patients who had undergone cataract surgery. The 69 eyes were classified into three subgroups according to the preoperative steep meridian. Following phacoemulsification, an intraocular lens was inserted into the bag. The keratometric measurements were taken 12 months postoperatively, on the anterior cornea (automated keratometer and anterior keratometry [K] from a rotating Scheimpflug camera) and total cornea (equivalent K reading [EKR] 3.0 mm, EKR 4.5 mm, total corneal refractive power (TCRP) 2.0 mm ring, TCRP 3.0 mm zone, TCRP 4.0 mm zone). The SIA was analyzed for each parameter. RESULTS: On the double-angle polar plot, the summated vector mean values of SIA determined by the automated keratometer and Scheimpflug anterior K were 0.28 diopter (axis: 177°) and 0.37 diopter (axis: 175°) in with-the-rule (WTR) astigmatism; 0.03 diopter (axis: 156°) and 0.18 diopter (axis: 177°) in oblique astigmatism; 0.15 diopter (axis: 96°) and 0.17 diopter (axis: 73°) in against-the-rule (ATR) astigmatism. The mean SIAs on the total cornea ranged from 0.31 to 0.42 diopter in WTR astigmatism; from 0.16 to 0.27 diopter in oblique astigmatism; from 0.04 to 0.11 diopter in ATR astigmatism. Mean magnitude SIA ranged from 0.41 to 0.46 diopter on anterior corneal surface and 0.50 to 0.62 diopter on total cornea. J0 and J45 of the posterior cornea showed no significant changes after cataract surgery, and the changes in J0 and J45 did not show any statistical differences between the anterior and total cornea (all p > 0.05). CONCLUSIONS: There were no differences in the summed vector mean values of SIA between the anterior cornea and the total cornea.


Asunto(s)
Astigmatismo , Catarata , Meridianos , Facoemulsificación , Astigmatismo/etiología , Córnea/cirugía , Topografía de la Córnea , Humanos , Implantación de Lentes Intraoculares , Facoemulsificación/efectos adversos , Refracción Ocular
12.
Int Ophthalmol ; 41(9): 2993-3005, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33876334

RESUMEN

PURPOSE: To investigate the impact of oxygen delivery on the clinical outcomes of accelerated transepithelial corneal cross-linking (A-TE CXL). METHODS: Fifty-seven eyes of 44 progressive keratoconus (KCN) patients were randomly separated into two age-sex-matched groups. Twenty-nine eyes of 23 KCN patients that underwent oxygen-supplemented A-TE CXL formed the study group and 28 eyes of 21 patients treated with the same procedure but under room air conditions formed the control group. All patients were examined preoperatively, one, six and twelve months after the procedure. The logMAR spectacle-corrected distance visual acuity (CDVA), maximum keratometry (Kmax), mean keratometry, apical posterior keratometry, cylindrical power, minimum central corneal thickness, keratoconus vertex front and back, ocular aberrations, endothelial cell density (ECD), demarcation line depth (DLD) and proportion measures were recorded for statistical analysis. RESULTS: The preoperative, 1st, 6th and 12th months mean Kmax values of the study group were 55.14 ± 3.99D, 54.85 ± 3.82D, 54.37 ± 3.84D and 54.40 ± 3.86, respectively, and 54.47 ± 3.17D, 54.52 ± 2.97D, 54.25 ± 2.95D and 54.20 ± 2.97 in the control group. The mean Kmax value was decreased significantly more in the oxygen-supplemented group after 12 months compared to the control group (p = 0.019). The mean DLD was also significantly deeper in the study group (320 ± 17 µm) compared to the control group (269 ± 19 µm). There was no significant difference between the two groups in terms of ECD alterations at any of the time intervals (p > 0.05). CONCLUSION: Keratoconus progression was significantly halted in both groups 12 months after the treatment. In addition, oxygen supplementation during A-TE CXL further significantly increased clinical outcomes compared to room air conditions without any significant change in ECD measures.


Asunto(s)
Queratocono , Fotoquimioterapia , Colágeno/uso terapéutico , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Queratocono/tratamiento farmacológico , Oxígeno/uso terapéutico , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Rayos Ultravioleta
13.
Cornea ; 40(3): 303-310, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33543874

RESUMEN

PURPOSE: To evaluate the long-term (5 years) results of 360 degrees intracorneal ring (ICR) implantation with and without corneal crosslinking (CXL) in patients with progressive keratoconus (KCN). METHOD: This historical cohort study was performed on 35 eyes with progressive KCN, which was randomly divided into 2 groups. Fourteen patients were implanted only with ICR, and 21 patients with KCN were treated with ICR plus CXL simultaneously. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), and refractive components were collected from patients' medical records. The biomechanical properties of patients were measured using the Corvis ST (Oculus, Inc, Weltzar, Germany). Corneal topography and aberrometry parameters were also recorded from the Pentacam HR device (Oculus). RESULTS: Both UCVA and CDVA increased in both groups after ICR implantation; however, this improvement was more significant in the ICR plus CXL group (P = 0.002 and P = 0.001, respectively). The mean improvement of CDVA in patients with ICR implantation with and without CXL was 0.56 ± 0.67 and 0.33 ± 0.61, respectively. A comparison of the long-term postoperative Tomographic and Biomechanical Index between 2 groups showed a better result in the ICR plus CXL group (P = 0.012). Topographic findings of the anterior corneal surface (flat-K, steep-K, mean-K, and astigmatism) after surgery were significantly better than before surgery in both groups (P < 0.05). CONCLUSIONS: Although ICR implantation alone might halt the KCN progression with acceptable visual, topographic, and biomechanical outcomes, the combination of ICR and CXL has an adjuvant and synergistic effect, especially in long-term follow-up.


Asunto(s)
Sustancia Propia/cirugía , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Queratocono/terapia , Fotoquimioterapia , Implantación de Prótesis , Agudeza Visual/fisiología , Adulto , Fenómenos Biomecánicos , Colágeno/metabolismo , Terapia Combinada , Córnea/fisiología , Sustancia Propia/metabolismo , Femenino , Estudios de Seguimiento , Humanos , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/cirugía , Masculino , Fármacos Fotosensibilizantes/uso terapéutico , Prótesis e Implantes , Riboflavina/uso terapéutico , Rayos Ultravioleta , Adulto Joven
14.
J Refract Surg ; 37(1): 42-48, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33432994

RESUMEN

PURPOSE: To evaluate the efficacy and safety of transepithelial corneal cross-linking (CXL) with supplemental oxygen. METHODS: This was a prospective, non-comparative, pilot cohort study conducted at the National Reference Center for Keratoconus (Toulouse, France) on patients with progressive keratoconus. Transepithelial, pulsed, accelerated CXL was performed in an oxygen-rich atmosphere. Oxygen goggles were applied to the eyes to maintain a high level of oxygen during treatment. The main efficacy outcome was the mean change from baseline in maximum keratometry (Kmax) and the secondary outcomes were the mean changes in flat keratometry (K1), steep keratometry (K2), mean keratometry (Km), corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), and demarcation line depth. The safety outcomes were the incidence of adverse events, the mean change in pachymetry, and endothelial cell count. RESULTS: Thirty-four eyes of 34 patients were included. At 12 months postoperatively, the Kmax decreased by 1.56 ± 1.71 diopters (D) (P < .0001) and CDVA improved by 0.093 ± 0.193 logMAR (P < .02). The K2 and Km decreased by 0.51 ± 1.03 D (P < .02) and 0.40 ± 0.78 D (P < .01), respectively. There was no change in K1 and UDVA. The most frequent adverse event was corneal haze (64.78%). There were neither cases of infectious keratitis or loss of more than two lines in CDVA nor changes in pachymetry or endothelial cell count. CONCLUSIONS: Transepithelial CXL performed in an oxygen-rich atmosphere results in improved Kmax and CDVA with good safety. These promising findings suggest that this procedure could be safe and capable of halting the progression of keratoconus. [J Refract Surg. 2021;37(1):42-48.].


Asunto(s)
Queratocono , Fotoquimioterapia , Colágeno/uso terapéutico , Paquimetría Corneal , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Queratocono/tratamiento farmacológico , Oxígeno , Fármacos Fotosensibilizantes/uso terapéutico , Proyectos Piloto , Estudios Prospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta
15.
Cornea ; 40(2): 251-253, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32858542

RESUMEN

ABSTRACT: We report on a 13-year-old girl undergoing changes in the refraction of her OS associated with eye rubbing. Corneal topography showed a corneal deformation in OS, classified as stage 1 keratoconus according to the Krumeich classification. A significant reduction in eye rubbing led to a normal corneal shape at the 1-year follow-up. Transient and fully reversible corneal ectasia can be caused by eye rubbing in pediatric age. This may have implications when counseling very young patients with eye rubbing.


Asunto(s)
Córnea/patología , Topografía de la Córnea , Queratocono/diagnóstico , Masaje/efectos adversos , Adolescente , Dilatación Patológica , Femenino , Estudios de Seguimiento , Humanos , Queratocono/etiología , Queratocono/fisiopatología , Refracción Ocular/fisiología , Agudeza Visual/fisiología
16.
Cont Lens Anterior Eye ; 44(3): 101330, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32418872

RESUMEN

PURPOSE: Return zone depth (RZD) and landing zone angle (LZA) are important parameters of corneal refractive therapy (CRT) lenses. A new machine learning algorithm is proposed for prescribing CRT lens parameters in Chinese adolescents with myopia. METHODS: This is a retrospective study. In total, 1037 Chinese adolescents with myopia (1037 right eyes) were enrolled. A calculation model based on corneal elevation maps was constructed to calculate RZD and LZA for the four quadrants. Furthermore, multiple linear regression and optimized machine learning models were established to predict RZD and LZA values for different combinations of age, sex, and ocular parameters. The four methods (sliding card, linear regression, calculation and optimized machine learning) were then compared to the parameters of the final ordered lens. RESULTS: The optimized machine learning pipeline achieved the best performance. Age, sex, horizontal visible iris diameter (HVID), spherical equivalent refraction degree (SER), eccentricity (e), keratometric (K) readings, corneal astigmatism (CA), axial length (AL), AL/corneal curvature ratio (AL/MK), and anterior chamber depth (ACD) were significant to the machine learning model. The R values for the nasal, temporal, superior and inferior LZA based on machine learning were 0.843, 0.693, 0.866 and 0.762, respectively, and those for the RZD were 0.970, 0.964, 0.975 and 0.964, respectively. CONCLUSIONS: The feasibility and efficiency of an optimized machine learning method to predict LZA and RZD parameters has been demonstrated. The advantage of the proposed method is that it is more accurate, easier to use and faster to implement than the traditional sliding card method.


Asunto(s)
Miopía , Adolescente , China , Córnea/diagnóstico por imagen , Topografía de la Córnea , Humanos , Aprendizaje Automático , Miopía/diagnóstico , Miopía/terapia , Refracción Ocular , Estudios Retrospectivos
17.
J Cataract Refract Surg ; 47(6): 773-779, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33252568

RESUMEN

PURPOSE: To investigate the potential additive effect of systemic supplemental oxygen administered during accelerated corneal crosslinking (CXL) for progressive keratoconus (KC). SETTING: Academic center. DESIGN: Randomized clinical trial. METHODS: Eyes with progressive KC randomized to 3 different CXL protocols were included. The first group (OA-CXL) included 19 eyes that underwent an accelerated CXL protocol (9 mW/cm2 for 10 minutes) while receiving systemic oxygen at a rate of 5 L/min for 10 minutes. The second group consisted of 14 eyes undergoing the same accelerated CXL protocol without supplemental oxygen therapy (A-CXL). The third group (C-CXL) comprised 14 eyes undergoing conventional CXL according to the Dresden protocol. All subjects were followed up for at least 6 months. Visual acuity, keratometry and corneal biomechanical parameters including corneal hysteresis and corneal resistance factor (CRF) were measured preoperatively and 6 months postoperatively. RESULTS: Reduction in maximum keratometry (Kmax) was significantly greater in the OA-CXL group (P = .01). At baseline, the mean Kmax was 54.31 ± 3.64 diopters (D) in the OA-CXL group, 54.66 ± 4.99 D in the A-CXL group, and 56.03 ± 5.28 D in the C-CXL group (P = .58), which reached 53.58 ± 3.24 D, 54.59 ± 4.65 D, and 55.87 ± 4.73 D at 6 months in the 3 study groups, respectively (P = .115). The mean CRF increased significantly only in the OA-CXL group from a baseline value of 6.32 ± 2.12 mm Hg to 7.38 ± 1.88 mm Hg at 6 months (P = .009). CONCLUSIONS: This study suggests superior efficacy of an accelerated CXL protocol coupled with systemic oxygen supplementation when compared with the accelerated CXL protocol and the conventional protocol in eyes with progressive KC. In addition to greater reduction in Kmax as the primary outcome, improvement in corneal biomechanics was also observed at 6 months.


Asunto(s)
Queratocono , Fotoquimioterapia , Colágeno/uso terapéutico , Córnea , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Queratocono/tratamiento farmacológico , Oxígeno/uso terapéutico , Terapia por Inhalación de Oxígeno , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Rayos Ultravioleta
18.
Rom J Ophthalmol ; 64(3): 313-321, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33367168

RESUMEN

Objective. The aim of the article was to present the rare association of retinitis pigmentosa and bilateral keratoconus in two brothers, one of whom developed corneal hydrops bilaterally, within a short period of time. Methods. A 29-year-old man presented to our service with corneal hydrops in the right eye, complaining of ocular pain and photophobia. He had a history of retinitis pigmentosa, having been diagnosed as an infant. He also had a younger brother carrying the same diagnosis. Slit lamp examination revealed bilateral keratoconus with corneal hydrops in the right eye, posterior subcapsular cataract, macular atrophy and the characteristic retinal signs of retinitis pigmentosa. The patient's brother was also examined, with the same findings being noted, apart from the corneal hydrops. We documented the changes using a slit lamp biomicroscope, a fundus camera, a corneal topography, Anterior Segment Optical Coherence Tomography and visual field testing. Right hydrops regressed in one month after hyperosmolar 5% sodium chloride treatment. However, 4 weeks later, the patient presented with the same corneal findings in the left eye. The same treatment was prescribed for the left eye. Results. Corneal hydrops regressed in both eyes with remaining paracentral corneal scars. However, no other treatment for keratoconus was suitable in the case of this patient. Discussion: Retinitis pigmentosa is currently not amenable to any form of treatment, from vitamin supplementation, medical therapy, gene transfer-based therapy, stem cell-based therapy to retinal implantation. However, molecular genetics may someday provide new therapeutic prospects, that could modify the course of RP. Conclusions. The association of retinitis pigmentosa with keratoconus is a fairly rare finding, worth taking into consideration. Also, presentation with keratoconus in such an advanced state is uncommon and, in our case, it was presumably due to the patient's reduced visual function since childhood, secondary to retinitis pigmentosa, that has prevented him from perceiving any visual modifications caused by keratoconus.


Asunto(s)
Córnea/patología , Queratocono/complicaciones , Retinitis Pigmentosa/complicaciones , Hermanos , Agudeza Visual , Adulto , Topografía de la Córnea , Humanos , Queratocono/diagnóstico , Masculino , Retinitis Pigmentosa/diagnóstico , Lámpara de Hendidura , Tomografía de Coherencia Óptica/métodos
19.
J Cataract Refract Surg ; 46(12): 1582-1587, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32858580

RESUMEN

PURPOSE: To evaluate the outcomes of customized corneal crosslinking (CXL) for treatment of progressive keratoconus (KC) using a transepithelial approach with supplemental oxygen. SETTING: Siena Crosslinking Center, Siena, Italy. DESIGN: Prospective interventional case series. METHODS: Twenty-seven eyes of 24 patients (mean age 29.3 ± 7.3 years) with progressive KC underwent customized corneal CXL using a transepithelial approach with supplemental oxygen. Ultraviolet (UV)-A irradiation of 365 nm wavelength was delivered in an accelerated (30 mW/cm) pulsed-light UV light exposure in a 2-zone elliptical pattern. A total dose of 10 J/cm was delivered at the KC apex, surrounded by a broadbeam spot of 7.2 J/cm. After 0.25% riboflavin corneal soaking, the UV-A irradiation was initiated in the presence of additional oxygen (≥90% concentration) delivered through special goggles connected to an oxygen delivery system (flow-rate 2.5 liters per minute). Key outcome measures included corrected distance visual acuity (CDVA), keratometry (AK, K1, K2, and K-average), corneal higher-order aberrations, topographic and manifest cylinder, corneal optical coherence tomography (OCT) demarcation line, and endothelial cell count. RESULTS: Of the 27 eyes studied, a significant improvement of CDVA was recorded at 6-month follow-up visits, from baseline 0.19 ± 0.06 logarithm of the minimum angle of resolution (logMAR) to 0.11 ± 0.04 logMAR (P < .05). Significant flattening of steep keratometry (K2) was reported with mean change of -1.9 diopters (D) (P < .05), and coma values improved from 0.47 ± 0.28 µm to 0.28 ± 0.16 µm (P < .05). OCT revealed 2 demarcation lines at mean depths of 218.23 ± 43.32 µm and 325.71 ± 39.70 µm. CONCLUSIONS: In this series, customized CXL using a transepithelial approach with intraoperative supplemental oxygen resulted in clinically meaningful improvements in corneal curvature and CDVA without significant adverse events.


Asunto(s)
Queratocono , Adulto , Colágeno , Sustancia Propia , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Italia , Queratocono/tratamiento farmacológico , Oxígeno , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Riboflavina/uso terapéutico , Tomografía de Coherencia Óptica , Rayos Ultravioleta , Adulto Joven
20.
J Int Med Res ; 48(6): 300060520926411, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32589855

RESUMEN

OBJECTIVE: To evaluate the clinical efficacy of corneal collagen cross-linking (CXL) in the treatment of infectious corneal diseases. METHODS: This study retrospectively analyzed the clinical efficacy of CXL in 65 eyes with infectious keratitis in Jinan Second People's Hospital from December 2016 to June 2018. During 6 months of follow-up after CXL treatment, the results of confocal microscopy and anterior segment optical coherence tomography, as well as visual acuity and corneal biomechanical parameters, were recorded in detail. RESULTS: In general, the overall cure rate was 93.85%; no corneal endothelial dysfunction was encountered in any patients. After 6 months of follow-up, the visual acuity of cured patients was significantly enhanced, while corneal thickness was significantly reduced. Hyphae growth of patients with fungal keratitis was completely inhibited at 1 month postoperatively. Furthermore, corneal biomechanical parameters (i.e., central corneal thickness, deformation amplitude, and pachymetry intraocular pressure) were significantly improved after surgery, compared with baseline measurements. CONCLUSION: Accelerated CXL may be an effective adjuvant treatment for infectious keratitis.


Asunto(s)
Queratitis , Queratocono , Fotoquimioterapia , Colágeno , Paquimetría Corneal , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Queratitis/tratamiento farmacológico , Queratocono/tratamiento farmacológico , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Retrospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA