Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros

Medicinas Complementárias
Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Med J Malaysia ; 76(3): 438-440, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-34031350

RESUMEN

Venous thrombosis is a potentially life-threatening condition with varied aetiology. First described in 1912 as a complication of peritonsillar abscess, internal jugular vein (IJV) thrombosis is a rare entity in children with very few cases reported until now. Among the leading causes of this condition are prolonged use of IJV for venous access and central venous catheterisation, acute mastoiditis and Lemierre's syndrome.1 IJV thrombosis can also occur as a complication of head and neck infections, but rarely appears as its first presentation. The clinical manifestations are often vague and ambiguous, thus requiring a high index of suspicion to diagnose IJV thrombosis. We describe here a case of internal jugular vein thrombosis (IJVT) and the management of this rare condition in an otherwise healthy 8- year-old boy. The patient was investigated thoroughly to rule out possible pathological causes of IJV thrombosis and managed holistically with a multidisciplinary team approach. Although the occurrence is rare, it should be recognised as a complication of deep neck infections in order to initiate prompt and accurate therapy.


Asunto(s)
Venas Yugulares , Trombosis de la Vena , Niño , Humanos , Venas Yugulares/diagnóstico por imagen , Masculino , Cuello , Síndrome , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología
2.
Aerosp Med Hum Perform ; 88(5): 457-462, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28417833

RESUMEN

BACKGROUND: The objective was to determine if short term exposure to dry immersion (DI) results in a cephalic fluid shift similar to what has been observed with spaceflight. METHODS: Data were collected from 10 individuals at rest and during the first 2 h of dry immersion. Jugular vein (JV), portal vein (PV), and thyroid volume were measured using 3D echography. Middle cerebral vein velocity (MCVv) was determined using transcranial Doppler ultrasound. The cochlear response to audio stimulation was used to derive an estimate of intracranial pressure (dICP). RESULTS: After 2 h of DI, there was a significant increase (mean ± SD) in JV (2.21 ± 1.10 mL), PV (1.05 ± 0.48 mL), and thyroid (0.428 ± 0.313 mL) volume. MCVv was also significantly increased with DI (3.90 ± 5.03 cm · s-1). There was no change in dICP with DI in part due to large individual variability. The range of dICP changes appeared to be related to MCVv, with participants with the largest increase in MCVv also showing increased dICP. DISCUSSION: The results suggest that DI induces a significant cephalic fluid shift similar to what is observed with spaceflight. The increased thyroid volume suggests that cerebral tissue may also be subjected to similar fluid filtration, with implications for changes in intracranial pressure. However, despite all participants having an increase in JV and thyroid volume, only half showed an increase in dICP, suggesting that increased venous pooling alone is not sufficient to cause increased intracranial pressure.Arbeille P, Avan P, Treffel L, Zuj K, Normand H, Denise P. Jugular and portal vein volume, middle cerebral vein velocity, and intracranial pressure in dry immersion. Aerosp Med Hum Perform. 2017; 88(5):457-462.


Asunto(s)
Venas Cerebrales/diagnóstico por imagen , Transferencias de Fluidos Corporales , Presión Intracraneal/fisiología , Venas Yugulares/diagnóstico por imagen , Vena Porta/diagnóstico por imagen , Simulación de Ingravidez , Estimulación Acústica , Adulto , Medicina Aeroespacial , Velocidad del Flujo Sanguíneo , Cóclea/fisiología , Voluntarios Sanos , Humanos , Imagenología Tridimensional , Venas Yugulares/anatomía & histología , Masculino , Tamaño de los Órganos , Vena Porta/anatomía & histología , Vuelo Espacial , Ultrasonografía Doppler Transcraneal
3.
PLoS One ; 10(10): e0141513, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26506095

RESUMEN

BACKGROUND AND PURPOSE: Thalamostriate vein (TSV) is an important tributary of the internal cerebral vein, which mainly drains the basal ganglia and deep medulla. The purpose of this study was to explore the anatomic variation and quality of TSV and its smaller tributaries using susceptibility-weighted imaging (SWI). METHODS: We acquired SWI images in 40 volunteers on a 3.0T MR system using an 8-channel high-resolution phased array coil. The frequencies of the TSV and its tributaries were evaluated. We classified TSV into types I (forming a venous angle) and II (forming a false venous angle). We classified anterior caudate vein (ACV)into types 1 (1 trunk) and 2 (2 trunks) as well as into types A (joiningTSV), B (joining anterior septal vein), and C (joining the angle of both veins). RESULTS: The TSV drains the areas of caudate nucleus, internal capsule,lentiform nucleus, external capsule, claustrum, extreme capsule and the white matter of the frontoparietal lobes,except thalamus. The frequencies of the TSV, ACV and transverse caudate vein (ACV) were 92.5%, 87.5% and 63.8%, respectively. We found TSV types I and II in 79.7%, and 20.3% with significantly different constitution ratios (P< 0.05). The most common types of ACV were type 1 (90.0%) and type A (64.3%). CONCLUSION: The complex three-dimensional (3D) venous architecture of TSV and its small tributaries manifests great variation, with significant and practical implications for neurosurgery.


Asunto(s)
Variación Anatómica , Venas Cerebrales/anatomía & histología , Diagnóstico por Imagen , Imagen por Resonancia Magnética , Adulto , Núcleo Caudado/anatomía & histología , Núcleo Caudado/diagnóstico por imagen , Corteza Cerebral/irrigación sanguínea , Venas Cerebrales/diagnóstico por imagen , Femenino , Humanos , Venas Yugulares/anatomía & histología , Venas Yugulares/diagnóstico por imagen , Masculino , Radiografía , Tálamo/irrigación sanguínea
4.
J Vasc Access ; 16(5): 431-3, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26109543

RESUMEN

INTRODUCTION: Central venous catheters are often required in oncologic patients for long-term safe administration of chemotherapeutic agents, antibiotics, and parenteral nutrition. Rupture of these devices and intracardiac migration is a rare complication. METHODS: We report one spontaneous rupture and embolization of a totally implantable vascular access device (TIVAD) in an asymptomatic patient. RESULTS: A 50-year-old woman received a TIVAD silicone catheter 8 FR for adjuvant chemotherapy. After 3 years of port time in situ, during a follow-up control, a catheter malfunction was found and radiologic investigations showed a rupture and migration of the catheter to the right ventricle. The attempt to remove the fragment under fluoroscopic control using the femoral route was unsuccessful. We did not try a surgical approach because of the complete absence of symptomatology and hemodynamic impairment. CONCLUSIONS: The catheter rupture and intracardiac embolization is a rare complication associated with totally implantable or tunneled central venous catheters. When such an event happens, the patient should be managed by expert hemodynamists or interventional radiologists making an effort to remove the fragment without surgical measures. When the intravascular percutaneous route fails, the possibility to leave the fragmented catheter in heart chambers should be evaluated, being surgery questionable in asymptomatic patients.


Asunto(s)
Antineoplásicos/administración & dosificación , Cateterismo Venoso Central/instrumentación , Catéteres Venosos Centrales , Remoción de Dispositivos , Embolia/terapia , Migración de Cuerpo Extraño/terapia , Venas Yugulares , Administración Intravenosa , Cateterismo Venoso Central/efectos adversos , Quimioterapia Adyuvante , Embolia/diagnóstico , Embolia/etiología , Diseño de Equipo , Falla de Equipo , Femenino , Migración de Cuerpo Extraño/diagnóstico , Migración de Cuerpo Extraño/etiología , Ventrículos Cardíacos , Humanos , Venas Yugulares/diagnóstico por imagen , Persona de Mediana Edad , Flebografía/métodos , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
Ann Vasc Surg ; 29(4): 650-3, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25752987

RESUMEN

BACKGROUND: We present 7 cases of pulsatile tinnitus (PT) of venous origin in younger women seen over a period of 24 years and treated by Internal Jugular Bulb ligation. METHODS: All patients had a pulsatile bruit in one side of the neck that disappeared when gentle pressure over the internal jugular vein (IJV) caused it to collapse as seen in a duplex scan. Their computed tomography showed a dominant venous system with a high jugular bulb on the side of the bruit. RESULTS: The IJV was ligated under local anesthesia. Five patients in whom the ligation was done above the facial vein were cured. Two patients in whom the ligation was done below the facial vein experienced a decrease but not disappearance of the PT. CONCLUSIONS: Once other possible causes for PT have been discarded, ligation of the IJV above the facial vein cures this condition.


Asunto(s)
Venas Yugulares/cirugía , Flujo Pulsátil , Acúfeno/cirugía , Adulto , Factores de Edad , Anestesia Local , Femenino , Humanos , Venas Yugulares/diagnóstico por imagen , Venas Yugulares/fisiopatología , Ligadura , Persona de Mediana Edad , Flebografía/métodos , Flujo Sanguíneo Regional , Inducción de Remisión , Estudios Retrospectivos , Factores Sexuales , Factores de Tiempo , Acúfeno/diagnóstico , Acúfeno/fisiopatología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Adulto Joven
6.
Sci Rep ; 4: 6540, 2014 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-25286775

RESUMEN

It has been recently demonstrated that the internal jugular vein may exhibit abnormalities classified as truncular venous malformations (TVMs). The investigation of possible morphological and biochemical anomalies at jugular tissue level could help to better understand the link between brain venous drainage and neurodegenerative disorders, recently found associated with jugular TVMs. To this end we performed sequential X-ray Fluorescence (XRF) analyses on jugular tissue samples from two TVM patients and two control subjects, using complementary energies at three different synchrotrons. This investigation, coupled with conventional histological analyses, revealed anomalous micro-formations in the pathological tissues and allowed the determination of their elemental composition. Rapid XRF analyses on large tissue areas at 12.74 keV showed an increased Ca presence in the pathological samples, mainly localized in tunica adventitia microvessels. Investigations at lower energy demonstrated that the high Ca level corresponded to micro-calcifications, also containing P and Mg. We suggest that advanced synchrotron XRF micro-spectroscopy is an important analytical tool in revealing biochemical changes, which cannot be accessed by conventional investigations. Further research on a larger number of samples is needed to understand the pathogenic significance of Ca micro-depositions detected on the intramural vessels of vein walls affected by TVMs.


Asunto(s)
Calcio/aislamiento & purificación , Venas Yugulares/diagnóstico por imagen , Microvasos/diagnóstico por imagen , Imagen Óptica , Adulto , Calcio/metabolismo , Femenino , Humanos , Venas Yugulares/metabolismo , Venas Yugulares/patología , Masculino , Microvasos/metabolismo , Microvasos/patología , Persona de Mediana Edad , Radiografía , Sincrotrones , Rayos X
7.
Nephrology (Carlton) ; 17(7): 603-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22715902

RESUMEN

AIM: Internal jugular vein (IJV) catheterization is often required to gain access for haemodialysis. Use of ultrasound guidance has reduced the complication rates of this procedure. We hypothesized that nephrologists may perform IJV cannulation with a high technical success and low immediate complication rates under real-time ultrasound guidance. METHODS: We prospectively analyzed 323 patients (186 male, 137 female) who underwent IJV cannulation with real-time ultrasound guidance. The number of needle punctures, technical success, the time between injection of local anaesthetic and entry into the IJV, and immediate complications were recorded. Patients with a history of multiple catheter insertions, previous difficulties during catheterization, poor compliance, obesity, impaired consciousness, skeletal deformity, disorder of haemostasis were regarded as high-risk group. RESULTS: Cannulation of IJV was achieved in all patients. Of the 323 catheters, 125 (38.7%) were placed in high-risk patients. Average number of puncture was 1.26 (range, 1-4). IJV was entered on the first attempt in 261 (80.8%) patients. Only ten complications (10/323, 3.2%) developed; five (2.5%) in the normal-risk group, and five (4.0%) in the high-risk group. Cannulation of IJV took a longer time in the high-risk group than in the normal-risk group. The number of needle punctures, percent of successful cannulation on the first attempt, and the frequency of complications were similar between the high- and normal-risk groups. CONCLUSIONS: Cannulation of IJV under real-time ultrasound guidance is very safe with high technical success rates. Nephrologists can use this technique with ease and with minimal complications in normal- and high-risk patients.


Asunto(s)
Cateterismo Venoso Central/métodos , Venas Yugulares/diagnóstico por imagen , Nefrología , Ultrasonografía Intervencional , Anciano , Anestesia Local , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/instrumentación , Catéteres Venosos Centrales , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Estudios Prospectivos , Punciones , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Turquía
8.
Europace ; 13(4): 539-42, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21252193

RESUMEN

AIMS: To evaluate and compare operator radiation exposure during the catheter placement in the coronary sinus via the femoral vein with a steerable catheter or the jugular vein with a fixed curve catheter. METHODS AND RESULTS: A total of 156 patients undergoing electrophysiological study or radiofrequency catheter ablation were prospectively assigned in a random fashion to either the femoral vein access (FVA) with a steerable curve deca-polar catheter (n= 80) or the jugular vein access (JVA) with a fixed curve deca-polar catheter (n = 76). All the catheterization procedures were performed by the same operator who had extensive experience in both accesses. Operator radiation exposure was measured with an electronic radiation dosimeter attached to the breast pocket of the operator on the outside of the lead apron and estimates of the ambient dose equivalent were derived. The operator radiation exposure was reduced significantly by using the FVA compared with the JVA (1.8 ± 1.3 vs. 8.6 ± 6.5 µSv; P < 0.001). The fluoroscopy time (62.7 ± 45.8 vs. 61.9 ± 46.5 s; P = NS) and dose-area product (3.2 ± 2.3 vs. 3.1 ± 2.1 Gy cm(2); P = NS) were not statistically different. CONCLUSION: Operator radiation exposure can be significantly reduced by using the FVA approach with a steerable curve catheter compared with the JVA approach with a fixed curve catheter, without increasing the fluoroscopy time and dose-area product.


Asunto(s)
Cateterismo Cardíaco/métodos , Seno Coronario/diagnóstico por imagen , Vena Femoral/diagnóstico por imagen , Fluoroscopía/efectos adversos , Venas Yugulares/diagnóstico por imagen , Cuerpo Médico , Dosis de Radiación , Adulto , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Exposición Profesional/prevención & control , Radiometría , Factores de Riesgo
9.
J Vasc Access ; 10(1): 27-32, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19340796

RESUMEN

PURPOSE: Evaluation of pain perception and patient satisfaction after implantation of a central venous port catheter system under local anesthesia. METHODS: A total of 100 consecutive patients (25 outpatients, 75 inpatients) who underwent successful implantation of a port catheter into the internal jugular vein from May through August 2007 were given an 8-item questionnaire. The extent of information about the implantation, the pain perception during implantation and the friendliness of the physician and nurse were evaluated. Furthermore, the patients were asked to assess their degree of anxiety and the pain they experienced during the intervention and to give an appraisal of whether local anesthesia was adequate. Each question was assessed on a 10-point scale (10 = very true to 1 = not at all true). In addition, the overall duration of the intervention (including patient preparation, implantation, patient aftercare, disinfection of the room) was documented. RESULTS: Patients felt highly satisfied with the way they were informed (mean score of 9.65) and considered the treating physician (9.89) and nurse (9.9) extremely friendly. Local anesthesia was rated as nearly completely adequate (9.56) and the degree of pain experienced was low (9.05; 10 = no pain). The average anxiety score was 8.56 (10 = not afraid at all). Overall satisfaction with the treatment was very high (9.62; outpatients: 9.72) and patients would recommend port catheter implantation at our department to others (9.77). The mean overall duration of the intervention was 76 min (range 40-120 min). CONCLUSION: Positive patient reactions indicate that radiologic port catheter implantation under local anesthesia is a minimally invasive intervention with high patient satisfaction that can be performed on an outpatient basis and is a valid alternative to surgical implantation.


Asunto(s)
Anestesia Local , Ansiedad/prevención & control , Cateterismo Venoso Central/instrumentación , Catéteres de Permanencia , Venas Yugulares , Dolor/prevención & control , Satisfacción del Paciente , Ansiedad/etiología , Actitud del Personal de Salud , Cateterismo Venoso Central/efectos adversos , Conocimientos, Actitudes y Práctica en Salud , Humanos , Pacientes Internos , Venas Yugulares/diagnóstico por imagen , Relaciones Enfermero-Paciente , Pacientes Ambulatorios , Dolor/etiología , Dimensión del Dolor , Educación del Paciente como Asunto , Relaciones Médico-Paciente , Radiografía Intervencional , Encuestas y Cuestionarios
10.
Undersea Hyperb Med ; 30(2): 87-91, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12964852

RESUMEN

In 1936 Lemierre described an aggressive neck infection with a high mortality rate. In the original characterization, he describes a pharyngotonsillitis and/or peritonsillar infection followed by unilateral swelling and tenderness along the sternocleidomastoid muscle owing to septic thrombophlebitis of the internal jugular vein. Subsequent to invasion and thrombophlebitis of the internal jugular vein, Fusobacterium necrophorum septicemia occurs, with rigors, high fever, and septic thromboembolism to peripheral sites, especially the lungs and bones. This entity became known as Lemierre Syndrome. Hyperbaric Oxygen (HBO2) has been described as adjunctive treatment in two cases of postanginal septicemia. This case describes the combined approach to a case of Lemierre Syndrome in which HBO2 was added as an adjunct to the treatment, with a favorable and rapid improvement in the patient's condition.


Asunto(s)
Infecciones por Fusobacterium/terapia , Fusobacterium necrophorum , Oxigenoterapia Hiperbárica/métodos , Enfermedades Pulmonares/terapia , Faringitis/terapia , Tonsilitis/terapia , Adolescente , Infecciones por Fusobacterium/diagnóstico por imagen , Infecciones por Fusobacterium/microbiología , Humanos , Venas Yugulares/diagnóstico por imagen , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Pulmonares/microbiología , Masculino , Cuello , Faringitis/diagnóstico por imagen , Faringitis/microbiología , Radiografía , Síndrome , Tromboembolia/diagnóstico por imagen , Tromboembolia/terapia , Tonsilitis/diagnóstico por imagen , Tonsilitis/microbiología
11.
Nucl Med Biol ; 30(1): 61-72, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12493544

RESUMEN

Two DNA aptamers directed against two separate exosites on human alpha-thrombin were evaluated for thrombus-imaging potential. Aptamer ODN 1 is directed to the thrombin substrate binding site (exosite 1). Our finding that ODN 1 competes with fibrin for binding to exosite 1 on thrombin suggests that ODN 1 will not be useful for thrombus imaging. Aptamer ODN 2 is directed against the thrombin heparin binding site (exosite 2). ODN 2 bound to model thrombi that were formed either by clotting purified fibrinogen with thrombin, or by recalcifying citrated plasma. As the thrombin content of thrombi was increased the rate of ODN 2 uptake into preformed thrombi increased, whereas the rate of release of ODN 2 out of preformed thrombi decreased. This in vitro data suggested that ODN 2 might be useful for thrombus imaging because it can bind to exosite 2 on fibrin-bound thrombin. However, in a rabbit jugular vein model using thrombus supplemented with human thrombin, ODN 2 uptake was equal to the ovalbumin control, and did not reflect thrombin content. While the in vitro results with ODN 2 were consistent with thrombus imaging, the rapid clearance of ODN 2 from circulation, combined with slow mass transfer in the clot, seem to work against in vivo thrombin-dependent imaging or washout analysis.


Asunto(s)
Radioisótopos de Yodo/farmacocinética , Oligonucleótidos/farmacocinética , Trombina/metabolismo , Trombosis/diagnóstico por imagen , Trombosis/metabolismo , Animales , Anticoagulantes/sangre , Anticoagulantes/farmacocinética , Secuencia de Bases , Sitios de Unión/genética , ADN/sangre , ADN/farmacocinética , Endotelio Vascular/diagnóstico por imagen , Endotelio Vascular/lesiones , Endotelio Vascular/metabolismo , Femenino , Fibrinógeno/metabolismo , Fluoroscopía/métodos , Humanos , Radioisótopos de Yodo/sangre , Marcaje Isotópico/métodos , Venas Yugulares/diagnóstico por imagen , Venas Yugulares/metabolismo , Ligandos , Datos de Secuencia Molecular , Oligonucleótidos/sangre , Oligonucleótidos/clasificación , Plasma/diagnóstico por imagen , Plasma/metabolismo , Unión Proteica , Conejos , Cintigrafía , Radiofármacos/sangre , Radiofármacos/farmacocinética , Serina Endopeptidasas/farmacología
12.
Ultraschall Med ; 12(6): 301-3, 1991 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-1796292

RESUMEN

To reduce the rate of complications and failures in central venous catheterisation a technique for ultrasonically controlled puncture of the internal jugular vein was standardised. The puncture procedure, including the application of local anaesthesia, is continuously observed and guided by real-time ultrasound. Imaging, control and practising of the puncture are described and discussed.


Asunto(s)
Cateterismo Venoso Central/instrumentación , Venas Yugulares/diagnóstico por imagen , Anestesia Local , Humanos , Venas Yugulares/cirugía , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA