Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Phys Med ; 32(4): 557-61, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27012541

RESUMO

PURPOSE: Image-guided radiotherapy (IGRT) based on bone matching can produce large target-positioning errors because of expiration breath-hold reproducibility during stereotactic body radiation therapy (SBRT) for liver tumors. Therefore, the feasibility of diaphragm-based 3D image matching between planning computed tomography (CT) and pretreatment cone-beam CT was investigated. METHODS: In 59 liver SBRT cases, Lipiodol uptake after transarterial chemoembolization was defined as a tumor marker. Further, the relative isocenter coordinate that was obtained by Lipiodol matching was defined as the reference coordinate. The distance between the relative isocenter coordinate and reference coordinate, which was obtained from diaphragm matching and bone matching techniques, was defined as the target positioning error. Furthermore, the target positioning error between liver matching and Lipiodol matching was evaluated. RESULTS: The positioning errors in all directions by the diaphragm matching were significantly smaller than those obtained by using by the bone matching technique (p < 0.05). Further, the positioning errors in the A-P and C-C directions that were obtained by using liver matching were significantly smaller than those obtained by using bone matching (p < 0.05). The estimated PTV margins calculated by the formula proposed by van Herk for diaphragm matching, liver matching, and bone matching were 5.0 mm, 5.0 mm, and 11.6 mm in the C-C direction; 3.6 mm, 2.4 mm, and 6.9 mm in the A-P direction; and 2.6 mm, 4.1 mm, and 4.6 mm in the L-R direction, respectively. CONCLUSIONS: Diaphragm matching-based IGRT may be an alternative image matching technique for determining liver tumor positions in patients.


Assuntos
Carcinoma Hepatocelular/radioterapia , Diafragma/fisiologia , Neoplasias Hepáticas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/metabolismo , Quimioembolização Terapêutica/métodos , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Diafragma/anatomia & histologia , Diafragma/diagnóstico por imagem , Óleo Etiodado/administração & dosagem , Óleo Etiodado/farmacocinética , Humanos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Pessoa de Meia-Idade , Mecânica Respiratória/fisiologia
2.
Artigo em Japonês | MEDLINE | ID: mdl-24464064

RESUMO

PURPOSE: Liver image guided radiation therapy (IGRT) based on bone matching risks generating serious target positioning errors for reasons of lack of reproducibility of expiration breath hold. We therefore investigated the feasibility of 3D image matching between planning CT images and pretreatment cone-beam computed tomography (CBCT) images based on diaphragm surface matching. METHOD: 27 liver stereotactic body radiotherapy (SBRT) cases in whom trancecatheter arterial chemoembolization (TACE) had been performed in advance of radiotherapy were manually image-matched based on contrast, Lipiodol used in the TACE as the marker of the tumor, and the relative coordinates of the isocenter obtained by contrast matching, defined as the reference coordinate. The target positioning difference between diaphragm matching and bone matching were evaluated by using relative coordinates of the isocenter from the reference obtained for each matching technique. RESULTS: The target positioning error using diaphragm matching and bone matching was 1.31±0.83 and 3.10±2.80 mm in the cranial-caudal (C-C) direction, 1.04±0.95 and 1.62±1.02 mm in the anterior-posterior (A-P) direction, and 0.93±1.19 and 1.12±0.94 mm in the left-right (L-R) direction, respectively. The positioning error due to diaphragm matching was significantly smaller than for bone matching in the C-C direction (p<0.05). CONCLUSION: IGRT based on diaphragm matching has potential as an alternative image matching technique for the positioning of liver patients.


Assuntos
Suspensão da Respiração , Diafragma , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/radioterapia , Posicionamento do Paciente/métodos , Radiocirurgia/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada de Feixe Cônico , Meios de Contraste , Óleo Etiodado , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA