Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Photodiagnosis Photodyn Ther ; 35: 102362, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34062305

RESUMO

AIM: The study aimed to assess the effect of in-vitro chlorhexidine and antimicrobial photodynamic therapy (aPDT) disinfection protocols against acrylic resin specimens colonized with S. mutans, S. aureus, E. coli, and C. albicans. MATERIAL AND METHODS: Reference strains of S. mutans, S. aureus, E. coli, and C. albicans were tested. Sixteen blocks of acrylic specimens were prepared by heat-cure acrylic resin and contaminated by in-vitro biofilm growth. Specimens in group 1, group 2 and group 3 were treated with Rose Bengal (RB), methylene blue (MB) 500 mg/L and porphyrin derivative (PD) 5 ml respectively, for the sensitization of biofilms. All photosensitizers (PS) were activated by LED at different wavelength. CHX was prepared in sterile distilled water and applied for 60 s. Each contaminated specimen was sprayed on all its surfaces with the aforementioned photosensitizers and control CHX. One-way analysis of variance (ANOVA) model was used to test the effect of the treatments and Tukey multiple comparison tests to compare means OF CFU/mL (log10) for exposed E. coli, C. albicans, S aureus, and S. mutans RESULTS: Specimens treated with 0.12% CHX (control) demonstrated a significant reduction in CFU/mL (log10) for exposed E. coli; 2.04±0.07 CFU/mL, C. albicans; 2.09±0.85 CFU/mL, S aureus; 3.04±0.11 CFU/mL, and S. mutans; 2.54±0.91 CFU/mL. The intragroup comparison revealed E.coli did not exhibit a decrease in reduction CFU/mL (log10) when acrylic resin irradiated with RB 5 µm. Whereas, CFU/mL (log10) values of S.aureus; 3.62±0.68 and S.mutans; 3.41±0.13 plummeted (p<0.05). Intergroup comparison showed E.coli values to display comparable reduction when disinfected with MB 500 mg/L and 0.12% CHX; 3.16±0.34 and 2.04±0.07 CFU/mL (log10) (p<0.05). CONCLUSION: Photosensitizers (RB, MB, PD) are selective in reducing bacterial count on acrylic resin blocks. CHX was found to be effective against all bacteria E.coli, C.albicans, S.aureus, and S.mutans at a concentration of 0.12%.


Assuntos
Fotoquimioterapia , Porfirinas , Resinas Acrílicas , Biofilmes , Dentaduras , Desinfecção , Escherichia coli , Azul de Metileno/farmacologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Polímeros , Rosa Bengala/farmacologia , Staphylococcus aureus , Streptococcus mutans
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA