RESUMO
: Nonischemic-dilated cardiomyopathy (NIDCM) is an entity that gathers extremely heterogeneous diseases. This awareness, although leading to continuous improvement in survival, has increased the complexity of NIDCM patients' management. Even though the endorsed 'red-flags' approach helps clinicians in pursuing an accurate etiological definition in clinical practice, it is not clear when and how peripheral centers should interact with referral centers with specific expertise in challenging scenarios (e.g. postmyocarditis and genetically determined dilated cardiomyopathy) and with easier access to second-line diagnostic tools and therapies. This position paper will summarize each step in NIDCM management, highlighting the multiple interactions between peripheral and referral centers, from first-line diagnostic workup and therapy to advanced heart failure management and long-term follow-up.
Assuntos
Cardiologia/normas , Cardiomiopatia Dilatada/terapia , Prestação Integrada de Cuidados de Saúde/normas , Técnicas de Imagem Cardíaca/normas , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/etiologia , Cardiomiopatia Dilatada/fisiopatologia , Tomada de Decisão Clínica , Consenso , Comportamento Cooperativo , Testes de Função Cardíaca/normas , Humanos , Comunicação Interdisciplinar , Equipe de Assistência ao Paciente/normas , Valor Preditivo dos Testes , Prognóstico , Encaminhamento e Consulta/normas , Fatores de Risco , Fatores de TempoRESUMO
BACKGROUND: High-risk hypertrophic cardiomyopathy (HCM) patients benefit from the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) may provide comparable protection while avoiding the shortcomings of transvenous (TV) leads. We assessed S-ICD eligibility according to surface ECG screening test in a cohort of high-risk HCM patients. METHODS AND RESULTS: 47 HCM patients (3 S-ICD candidates; 41 TV-ICD patients without pacing indication; and 3 pacemaker-dependent TV-ICD patients) underwent 4 screening protocols: standard (n = 44); exercise (n = 33); continuous pacing (n = 44); alternating paced/spontaneous QRS (n = 41). Of the 44 patients in the standard screening group, 41 (93%) were eligible. Max LV thickness was inversely related to the number of qualifying leads (3 leads: 21 ± 4 mm; 2 leads: 22 ± 6 mm; 1 lead: 25 ± 6 mm; no leads: 28 ± 11 mm; P = 0.07). Of the 33 patients in the exercise group, 5 were ineligible (3 after exercise). Of these, 2 became eligible after moving sternal electrodes from the left to the right parasternal line (eligibility rate: 30/33; 91%). Of the 44 patients in the continuous pacing group, 28 (64%) were eligible, 8 of which with right parasternal electrodes. In the paced/spontaneous QRS group (n = 41), 21 patients (51%) had at least 1 eligible lead during pacing and retained compatibility on the same lead during spontaneous rhythm, 5 of which with right parasternal electrodes. CONCLUSIONS: S-ICD screening failure is low in HCM, provided that patients with severe hypertrophy are carefully evaluated. Exercise test should be performed and right parasternal leads tested. Pacemaker patients display lower eligibility rate.