Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Med Biol ; 68(6)2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36821866

RESUMO

Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets.Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with publishedin silicobiophysical models to elucidate the potential biological effects of collimated and uncollimated fields.Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keVµm-1in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keVµm-1. Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction.Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.


Assuntos
Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Método de Monte Carlo
2.
J Radiol Prot ; 40(3): 848-860, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32575092

RESUMO

Collimating apertures are used in proton therapy to laterally conform treatment fields to the target volume. While this is a standard technique in passive spreading treatment heads, patient-specific apertures can supplement pencil-beam scanning (PBS) techniques to sharpen the lateral dose fall-off. A radiation protection issue is that proton-induced nuclear reactions can lead to the formation of radionuclides in the apertures. In the experiments of the current study, cylindrical, thick brass targets were irradiated with quasi-monoenergetic proton fields of 100.0 MeV and of 226.7 MeV in PBS mode. The radioactivation of these two brass samples was characterised with a low-level gamma-ray spectrometer. The activation products were scored in a Monte Carlo simulation, too, and compared with the experimental activities. For the high-energy field, 63Zn, 60Cu, and 61Cu were the most important short-lived isotopes regarding the measured specific activity. After irradiation with the 100.0 MeV field, 62Cu, 63Zn, and 60Cu had the highest activity. Regarding long-lived isotopes, which determine the storage time of the used apertures, the isotopes 57Co, 65Zn, 54Mn, 56Co had the largest contribution to the activity. The relative difference of activities between simulation and experiment was typically between 10%-20% for short-lived nuclides and were up to a factor of five larger for long-lived nuclides. Summarising experiments and simulations for both incident proton energies, 62Cu was the most important detected residual nucleus regardless if specific activity or equivalent dose is considered.


Assuntos
Cobre/química , Terapia com Prótons/métodos , Proteção Radiológica/métodos , Zinco/química , Radioisótopos de Cobre , Humanos , Método de Monte Carlo , Radiometria/instrumentação , Dosagem Radioterapêutica , Espectrometria gama , Radioisótopos de Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA