Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Medicinas Complementares
Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Neurointerv Surg ; 13(3): 207-211, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32487768

RESUMO

BACKGROUND: To date, the choice of optimal anesthetic management during endovascular therapy (EVT) of acute ischemic stroke patients remains subject to debate. We aimed to compare functional outcomes and complication rates of EVT according to the first-line anesthetic management in two comprehensive stroke centers: local anesthesia (LA) versus general anesthesia (GA). METHODS: Retrospective analysis of prospectively collected databases, identifying all consecutive EVT for strokes in the anterior circulation performed between January 1, 2018 and December 31, 2018 in two EVT-capable stroke centers. One center performed EVT under LA in the first intention, while the other center systematically used GA. Using propensity score analysis, the two groups underwent 1:1 matching, then procedural metrics, complications, and clinical outcomes were compared. Good outcome was defined as 90 days modified Rankin Scale (mRS) ≤2, and successful recanalization as modified Thrombolysis In Cerebral Ischemia (mTICI) 2b-3. RESULTS: During the study period, 219 patients were treated in the LA center and 142 in the GA center. Using the propensity score, 97 patients from each center were matched 1:1 according to the baseline characteristics. Local anesthesia was associated with a significantly lower proportion of good outcome (36.1% vs 52.0%, OR 0.53, 95% CI 0.33 to 0.87; p=0.039), lower rate of successful recanalization (70.1% vs 95.8%, OR 0.13, 95% CI 0.04 to 0.39; p<0.001), and more procedural complications (14.4% vs 3.0%, OR 3.44, 95% CI 1.09 to 14.28; p=0.018). There were no significant differences in 90-day mortality or symptomatic hemorrhagic transformation rates. CONCLUSIONS: In this study, systematic use of GA for stroke EVT was associated with better clinical outcomes, higher recanalization rates, and fewer procedural complications compared with patients treated under LA as the primary anesthetic approach.


Assuntos
Anestesia Geral/métodos , Anestesia Local/métodos , Isquemia Encefálica/terapia , Procedimentos Endovasculares/métodos , Pontuação de Propensão , Acidente Vascular Cerebral/terapia , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Sedação Consciente/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Resultado do Tratamento
2.
J Neurointerv Surg ; 11(7): 706-709, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30567844

RESUMO

BACKGROUND: Initial clinical experience with Squid shows subjectively reduced artifacts on post-embolization CT scans compared with Onyx. To further investigate these observations, we aimed to perform a comparison of artifacts between Squid and Onyx in a controlled in vitro model. MATERIALS AND METHODS: Onyx 18 and all four variants of Squid (Squid 18, Squid 18 low density (LD), Squid 12, Squid 12 LD) were each injected in dimethylsulfoxide (DMSO) compatible test tubes. The tubes containing precipitated embolic material were inserted in a CT phantom for conventional and flat panel CT acquisitions. Beam hardening artifacts were quantified using objective and subjective measurements. RESULTS: Objective evaluation of artifacts within regions of interest (ROIs) placed around the embolic material on CT and flat panel CT images demonstrated significantly lower noise and Hounsfield unit (HU) range values for all four Squid products compared with Onyx 18. On both CT and flat panel CT, LD variants of Squid 18 and Squid 12 had significantly lower noise and HU range values than their normal density counterparts on longitudinal ROIs. When using subjective measures for diagnostic value within ROIs placed around the embolic material on both CT and flat panel CT images, the number of non-diagnostic ROIs was significantly higher for Onyx 18 than for all four Squid variants. CONCLUSION: All four variants of Squid induced fewer beam hardening artifacts than Onyx 18 on CT and flat panel CT acquisitions. LD variants of Squid induced fewer artifacts than their normal density counterparts.


Assuntos
Artefatos , Imagens de Fantasmas/normas , Polivinil/normas , Tantálio/normas , Combinação de Medicamentos , Avaliação Pré-Clínica de Medicamentos/métodos , Embolização Terapêutica/métodos , Humanos , Polivinil/efeitos adversos , Tantálio/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA