Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Heart Rhythm ; 16(12): 1883-1889, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31255845

RESUMO

BACKGROUND: Catheter navigation and 3-dimensional (3D) cardiac mapping are essential components of minimally invasive electrophysiological procedures. OBJECTIVE: The purpose of this study was to develop a novel 3D mapping system (KODEX - EPD, EPD Solutions, Best, The Netherlands) that measures changing electric field gradients induced on intracardiac electrodes to enable catheter localization and real-time 3D cardiac mapping. METHODS: We first validated the accuracy of the system's measurement and localization capabilities by comparing known and KODEX - EPD-measured distances and locations at 12 anatomical landmarks in both the atria and ventricles of 4 swine. Next, in vivo images of 3D porcine cardiac anatomy generated by KODEX - EPD and widely used CARTO 3 system (Biosense Webster, Inc., Diamond Bar, CA) were compared with gold standard computed tomography images acquired from the same animals. Finally, 3D maps of atrial anatomy were created for 22 patients with paroxysmal atrial fibrillation (Dielectric Unravelling of Radiofrequency ABLation Effectiveness trial). RESULTS: First, the mean error between known and measured distances was 1.08 ± 0.11 mm (P < .01) and the overall standard deviation between known and measured locations in 12 areas of the porcine heart was 0.35 mm (P < .01). Second, an expert comparison of 3D image quality revealed that KODEX - EPD is noninferior to CARTO 3. Third, the system enabled 3D imaging of atrial anatomy in humans, provided real-time images of atrioventricular valves, and detected important anatomical variations in a subset of patients. CONCLUSION: The KODEX - EPD system is a novel 3D mapping system that accurately detects catheter location and can generate high-resolution images without the need for preacquired imaging, specialty catheters, or a point-by-point mapping procedure.


Assuntos
Fibrilação Atrial , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Cirurgia Assistida por Computador , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Precisão da Medição Dimensional , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Avaliação de Resultados em Cuidados de Saúde , Ajuste de Prótese/instrumentação , Ajuste de Prótese/métodos , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Suínos
2.
J Cardiovasc Electrophysiol ; 15(4): 418-27, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15089990

RESUMO

INTRODUCTION: Conventional electrical therapies for heart failure (HF) encompass defibrillation and ventricular resynchronization for patients at high risk for lethal arrhythmias and/or with inhomogeneous ventricular contraction. Cardiac contractility modulation (CCM) by means of nonexcitatory electrical currents delivered during the action potential plateau has been shown to acutely enhance systolic function in humans with HF. The aim of this multicenter study was to assess the chronic safety and preliminary efficacy of an implantable device delivering this novel form of electrical therapy. METHODS AND RESULTS: Thirteen patients with drug-resistant HF (New York Heart Association [NYHA] class III) were consecutively implanted with a device (OPTIMIZER II) delivering CCM biphasic square-wave pulses (20 ms, 5.8-7.7 V, 30 ms after detection of local activation) through two right ventricular leads screwed into the right aspect of the interventricular septum. CCM signals were delivered 3 hours daily over 8 weeks (3-hour phase) and 7 hours daily over the next 24 weeks (7-hour phase). Safety and feasibility of this novel therapy were regarded as primary endpoints. Preliminary clinical efficacy, -as expressed by changes in ejection fraction (EF), NYHA class, 6-minute walking test (6-MWT), peak O(2) uptake (peak VO(2)), and Minnesota Living with HF Questionnaire (MLWHFQ), was assessed at baseline and at the end of each phase. At the end of follow-up (8.8 +/- 0.2 months), all patients were alive, without heart transplantation or need for left ventricular assist device. Serial 24-hour Holter analysis revealed no proarrhythmic effect. No devices malfunctioned or failed for any reason other than end-of-battery life. Throughout the two study phases, EF improved from 22.7 +/- 7% to 28.7 +/- 7% and 37 +/- 13% (P = 0.004), 6-MWT from 418 +/- 99 m to 477 +/- 96 m and 510 +/- 107 m (P = 0.002), MLWHFQ from 36 +/- 21 to 18 +/- 12 and 7 +/- 6 (P = 0.002), peak VO(2) from 13.7 +/- 1.1 to 14.9 +/- 1.9 to 16.2 +/- 2.4 (P = 0.037), and NYHA class from 3 to 1.8 +/- 0.4 to 1.5 +/- 0.7 (P < 0.001). CONCLUSION: CCM therapy appears to be safe and feasible. Proarrhythmic effects of this novel therapy seem unlikely. Preliminary data indicate that CCM gradually and significantly improves systolic performance, symptoms, and functional status. CCM therapy for 7 hours per day is associated with greater dispersion near the mean, emphasizing the need to individually tailor CCM delivery duration. The technique appears to be attractive as an additive treatment for severe HF. Controlled randomized studies are needed to validate this novel concept.


Assuntos
Desfibriladores Implantáveis , Terapia por Estimulação Elétrica/métodos , Insuficiência Cardíaca/terapia , Contração Miocárdica/fisiologia , Sístole/fisiologia , Doença Crônica/terapia , Resistência a Medicamentos , Terapia por Estimulação Elétrica/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Segurança , Inquéritos e Questionários , Resultado do Tratamento
3.
Am J Cardiol ; 90(12): 1307-13, 2002 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-12480039

RESUMO

We assessed the feasibility of cardiac contractility modulation (CCM) by electric currents applied during the refractory period in patients with heart failure (HF). Extracellular electric currents modulating action potential and calcium transients have been shown to potentiate myocardial contractility in vitro and in animal models of chronic HF. CCM signals were biphasic square-wave pulses with adjustable amplitude, duration, and time delay from sensing of local electric activity. Signals were applied to the left ventricle through an epicardial vein (in 12 patients) or to the right ventricular (RV) aspect of the septum endocardially (in 6 patients). Simultaneous left ventricular (LV) and aortic pressure measurements were performed using a Millar catheter (Millar Instruments, Houston, Texas). Hemodynamics during RV temporary dual-chamber pacing was regarded as the control condition. Both LV and RV CCM stimulation increased dP/dt(max) to a similar degree (9.1 +/- 4.5% and 7.1 +/- 0.8%, respectively; p <0.01 vs controls), with associated aortic pulse pressure changes of 10.3 +/- 7.2% and 10.8 +/- 1.1% (p <0.01 vs controls). Regional systolic wall motion assessed quantitatively by color kinesis echocardiography was markedly enhanced near the CCM electrode, and the area of increased contractility involved 4.6 +/- 1.2 segments per patient. In 6 patients with HF with left bundle branch block, CCM signals delivered during biventricular pacing (BVP) produced an additional 16.1 +/- 3.7% increase in dP/dt(max) and a 17.0 +/- 7.5% increase in pulse pressure compared with BVP alone (p <0.01). CCM stimulation in patients with HF enhanced regional and global measures of LV systolic function, regardless of the varied delivery chamber or whether modulation was performed during RV pacing or BVP.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiomiopatia Dilatada/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Função Ventricular , Aorta/fisiologia , Pressão Sanguínea/fisiologia , Bloqueio de Ramo/fisiopatologia , Cardiomiopatia Dilatada/complicações , Ecocardiografia Doppler em Cores , Condutividade Elétrica , Estimulação Elétrica/métodos , Eletrocardiografia , Eletrodos , Estudos de Viabilidade , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA