Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Psychophysiol ; 15(3): 181-95, 1993 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8166843

RESUMO

Using 133Xe regional cerebral blood flow (CBF) imaging, two male groups having high and low hypnotic susceptibility were compared in waking and after hypnotic induction, while at rest and while experiencing ischemic pain to both arms under two conditions: attend to pain and suggested analgesia. Differences between low and highly-hypnotizable persons were observed during all hypnosis conditions: only highly-hypnotizable persons showed a significant increase in overall CBF, suggesting that hypnosis requires cognitive effort. As anticipated, ischemic pain produced CBF increases in the somatosensory region. Of major theoretical interest is a highly-significant bilateral CBF activation of the orbito-frontal cortex in the highly-hypnotizable group only during hypnotic analgesia. During hypnotic analgesia, highly-hypnotizable persons showed CBF increase over the somatosensory cortex, while low-hypnotizable persons showed decreases. Research is supportive of a neuropsychophysiological model of hypnosis (Crawford, 1991; Crawford and Gruzelier, 1992) and suggests that hypnotic analgesia involves the supervisory, attentional control system of the far-frontal cortex in a topographically specific inhibitory feedback circuit that cooperates in the regulation of thalamocortical activities.


Assuntos
Circulação Cerebrovascular/fisiologia , Hipnose Anestésica , Dor/fisiopatologia , Adulto , Braço/irrigação sanguínea , Humanos , Isquemia/fisiopatologia , Masculino , Medição da Dor , Fluxo Sanguíneo Regional/fisiologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-2236584

RESUMO

1. A portable, head-mounted device was developed for administration of light therapy. A randomized crossover protocol was used to test the therapeutic efficacy of this device, compared to a standard light box, for treatment of winter depression. 2. Depressive symptoms were significantly reduced by both the head-mounted device and the light box. 3. Therapeutic efficacy of the two devices was not significantly different. 4. The head-mounted device was rated by patients as significantly more convenient than the conventional light box; this may be important in improving patient compliance.


Assuntos
Transtorno Depressivo/terapia , Fototerapia/instrumentação , Adulto , Transtorno Depressivo/psicologia , Feminino , Humanos , Masculino , Escalas de Graduação Psiquiátrica , Estações do Ano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA