Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 22(9): 1072-1082, 2021 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-33709096

RESUMO

AIMS: To investigate the change in atherosclerotic plaque volume in patients with chronic kidney disease (CKD) and declining renal function, using coronary computed tomography angiography (CCTA). METHODS AND RESULTS: In total, 891 participants with analysable serial CCTA and available glomerular filtration rate (GFR, derived using Cockcroft-Gault formulae) at baseline (CCTA 1) and follow-up (CCTA 2) were included. CKD was defined as GFR <60 mL/min/1.73 m2. Declining renal function was defined as ≥10% drop in GFR from the baseline. Quantitative assessment of plaque volume and composition were performed on both scans. There were 203 participants with CKD and 688 without CKD. CKD was associated with higher baseline total plaque volume, but similar plaque progression, measured by crude (57.5 ± 3.4 vs. 65.9 ± 7.7 mm3/year, P = 0.28) or annualized (17.3 ± 1.0 vs. 19.9 ± 2.0 mm3/year, P = 0.25) change in total plaque volume. There were 709 participants with stable GFR and 182 with declining GFR. Declining renal function was independently associated with plaque progression, with higher crude (54.1 ± 3.2 vs. 80.2 ± 9.0 mm3/year, P < 0.01) or annualized (16.4 ± 0.9 vs. 23.9 ± 2.6 mm3/year, P < 0.01) increase in total plaque volume. In CKD, plaque progression was driven by calcified plaques whereas in patients with declining renal function, it was driven by non-calcified plaques. CONCLUSION: Decline in renal function was associated with more rapid plaque progression, whereas the presence of CKD was not.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Insuficiência Renal Crônica , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Progressão da Doença , Humanos , Rim/fisiologia , Placa Aterosclerótica/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico por imagem
2.
Catheter Cardiovasc Interv ; 95(1): 45-53, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31038290

RESUMO

OBJECTIVES: To demonstrate safety, feasibility and short-term clinical outcomes after transcatheter aortic valve-in-valve (ViV) implantation under local anesthesia without contrast aortography or echocardiographic guidance. BACKGROUND: Transcatheter ViV implantation is an emerging treatment modality for patients with degenerative surgical bioprostheses. Given the radiopaque properties of the surgical aortic valve (SAV) frame, ViV procedures can often be performed with fluoroscopic guidance alone. METHODS: ViV implantation was performed in 37 patients with SAV failure under local anesthesia without contrast aortography. Clinical and echocardiographic data were obtained at baseline, discharge, and 30 days. RESULTS: Mean age was 74 ± 10 years and STS predicted risk of mortality was 5.6 ± 2.4%. Mean transaortic gradient decreased from 39.4 ± 15.5 mmHg to 13 ± 6.3 mmHg at discharge (p < .001), and 20 ± 7.5 mmHg at 30 days (p < .001 compared to baseline), aortic valve area increased from 0.9 ± 0.3 cm2 to 1.2 ± 0.4 cm2 at 30 days (p = .007). No patient had more than mild aortic regurgitation. Hospital discharge occurred at a median of 2.6 ± 4.4 days. At 30-day follow-up there were no deaths, myocardial infarctions, strokes, repeat hospital admissions for heart failure, or renal failure. One patient (2.7%) required a new pacemaker. 93% of the patients were in New York Heart Association functional class I or II. CONCLUSIONS: Transcatheter aortic ViV implantation for selected patients with degenerative surgical bioprostheses under local anesthesia without aortography or echocardiographic guidance is feasible and safe.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Anestesia Local , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
3.
J Cardiovasc Comput Tomogr ; 12(3): 231-237, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29802032

RESUMO

BACKGROUND: The aim of the study is examine the impact of non-obstructive (<50%stenosis) left main (LM) disease on the natural history of coronary artery disease using serial coronary computed tomography angiography (CTA). METHODS: CTAs from the PARADIGM (Progression of atherosclerotic plaque determined by computed tomographic angiography imaging) study, a prospective multinational registry of patients who underwent serial CTA at a ≥2 year interval were analyzed. Those without evidence of CAD on their baseline scan were excluded, as were those with obstructive left main disease. Coronary artery vessels and their branches underwent quantification of: plaque volume and composition; diameter stenosis; presence of high-risk plaque. RESULTS: Of 944 (62 ±â€¯9 years, 60% male) who had evidence of CAD at baseline, 444 (47%) had LM disease. Those with LM disease had a higher baseline plaque volume (194.8 ±â€¯221mm3 versus 72.9 ±â€¯84.3mm3, p < 0.001) and a higher prevalence of high-risk plaque (17.5% versus 13%, p < 0.001) than those without LM disease. On multivariable general linear model, patients with LM disease had greater annual rates of progression of total (26.5 ±â€¯31.4mm3/yr versus 14.9 ±â€¯20.1mm3/yr, p < 0.001) and calcified plaque volume (17 ±â€¯24mm3/yr versus 7 ±â€¯11mm3/yr, p < 0.001), with no difference in fibrous, fibrofatty or necrotic core plaque components. CONCLUSION: The presence of non-obstructive LM disease is associated with greater rates of plaque progression and a higher prevalence of high-risk plaque throughout the entire coronary artery tree compared to CAD without LM involvement. Our data suggests that non-obstructive LM disease may be a marker for an aggressive phenotype of CAD that may benefit from more intensive treatment strategies.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Idoso , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/patologia , Estenose Coronária/epidemiologia , Estenose Coronária/patologia , Vasos Coronários/patologia , Progressão da Doença , Feminino , Fibrose , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Necrose , Placa Aterosclerótica , Valor Preditivo dos Testes , Prevalência , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/epidemiologia , Calcificação Vascular/patologia
4.
Circ Cardiovasc Qual Outcomes ; 9(3): 312-21, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27116975

RESUMO

We describe the development, implementation, and evaluation of a standardized clinical pathway to facilitate safe discharge home at the earliest time after transfemoral transcatheter aortic valve replacement. Between May 2012 and October 2014, the Heart Team developed a clinical pathway suited to the unique requirements of transfemoral transcatheter aortic valve replacement in contemporary practice. The components included risk-stratified minimalist periprocedure approach, standardized postprocedure care with early mobilization and reconditioning, and criteria-driven discharge home. Our aim was to reduce variation in care, identify a subgroup of patients suitable for early discharge (≤48 hours), and decrease length of stay for all patients. We addressed barriers related to historical practices, complex multidisciplinary stakeholder engagement, and adoption of length of stay as a quality indicator. We retrospectively reviewed the experiences of 393 consecutive patients; 150 (38.2%) were discharged early. At baseline, early discharge patients had experienced less previous balloon aortic valvuloplasty, had higher left ventricular ejection fraction, better cognitive function, and were less frail than the standard discharge group (>48 hours). Early discharge was associated with the use of local anesthesia, implantation of balloon expandable device, avoidance of urinary catheter, and early removal of temporary pacemaker. Median length of stay was 1 day for early discharge and 3 days for other patients; 97.7% were discharged home. There were no differences in 30-day mortality (1.3%), disabling stroke (0.8%), or readmission (10.7%). The implementation of a transcatheter aortic valve replacement clinical pathway shifted the program's approach to combine standardized processes and individual risk stratification. The Vancouver transcatheter aortic valve replacement clinical pathway requires a rigorous assessment to determine its efficacy, safety, and reproducibility.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Procedimentos Clínicos/organização & administração , Prestação Integrada de Cuidados de Saúde/organização & administração , Tempo de Internação , Alta do Paciente , Avaliação de Processos em Cuidados de Saúde/organização & administração , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Colúmbia Britânica , Difusão de Inovações , Próteses Valvulares Cardíacas , Humanos , Modelos Organizacionais , Segurança do Paciente , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Avaliação de Programas e Projetos de Saúde , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA