Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Amino Acids ; 41(2): 311-20, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20552382

RESUMO

It is hypothesized that metal ion-mediated adsorption of phosphorylated peptides on stationary phases of LC-columns is the major cause for their frequently observed poor detection efficiency in LC-MS. To study this phenomenon in more detail, sample solutions spiked with metal ion-mobilizing additives were analyzed by reversed phase µLC-ICP-MS or nanoLC-ESI-MS. Using µLC-ICP-MS, metal ions were analyzed directly as atomic ions. Using electrospray ionization, either metal ion chelates or phosphopeptide standard mixtures injected in subpicomole amounts were analyzed. Deferoxamine, imidazole, ascorbate, citrate, EDTA, and the tetrapeptide pSpSpSpS were tested as sample additives for the interlinked purposes of metal ion-mobilization and improvement of phosphopeptide recovery. Iron probably represents the major metal ion contamination of reversed phase columns. Based on the certified iron level in LC-grade solvents, a daily metal ion load of >10 pmol was estimated for typical nanoLC flow rates. In addition, phosphopeptide fractions from IMAC columns were identified as source for metal ion contamination of the LC column, as demonstrated for Ga(3+)-IMAC. The three metal ion-chelating additives, EDTA, citrate and pSpSpSpS, were found to perform best for improving the LC recovery of multiply phosphorylated peptides injected at subpicomole amounts. The benefits of metal ion-mobilizing LC (mimLC) characterized by metal ion complexing sample additives is demonstrated for three different instrumental setups comprising (a) a nanoUPLC-system with direct injection on the analytical column, (b) a nanoLC system with inclusion of a trapping column, and (c) the use of a HPLC-Chip system with integrated trapping and analytical column.


Assuntos
Cromatografia de Fase Reversa/métodos , Complexos de Coordenação/química , Fragmentos de Peptídeos/química , Fosfoproteínas/química , Adsorção , Alumínio/química , Sequência de Aminoácidos , Ácido Ascórbico/química , Cromatografia de Fase Reversa/instrumentação , Cromatografia de Fase Reversa/normas , Desferroxamina/química , Imidazóis/química , Ferro/química , Dados de Sequência Molecular , Nanotecnologia/métodos , Nanotecnologia/normas , Fragmentos de Peptídeos/normas , Fosfoproteínas/normas , Fósforo/química , Padrões de Referência , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA