1.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37410906

RESUMO

Interventional electrophysiology offers a great variety of treatment options to patients suffering from symptomatic cardiac arrhythmia. Catheter ablation of supraventricular and ventricular tachycardia has globally evolved a cornerstone in modern arrhythmia management. Complex interventional electrophysiological procedures engaging multiple ablation tools have been developed over the past decades. Fluoroscopy enabled interventional electrophysiologist throughout the years to gain profound knowledge on intracardiac anatomy and catheter movement inside the cardiac cavities and hence develop specific ablation approaches. However, the application of X-ray technologies imposes serious health risks to patients and operators. To reduce the use of fluoroscopy during interventional electrophysiological procedures to the possibly lowest degree and to establish an optimal protection of patients and operators in cases of fluoroscopy is the main goal of modern radiation management. The present manuscript gives an overview of possible strategies of fluoroscopy reduction and specific radiation protection strategies.


Assuntos
Ablação por Cateter , Exposição à Radiação , Humanos , Arritmias Cardíacas/terapia , Eletrofisiologia Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Fluoroscopia/métodos , Doses de Radiação , Exposição à Radiação/efeitos adversos
2.
Pacing Clin Electrophysiol ; 45(2): 219-228, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34919281

RESUMO

INTRODUCTION: Electrogram (EGM) fractionation is often associated with diseased atrial tissue; however, mechanisms for fractionation occurring above an established threshold of 0.5 mV have never been characterized. We sought to investigate during sinus rhythm (SR) the mechanisms underlying bipolar EGM fractionation with high-density mapping in patients with atrial fibrillation (AF). METHODS: Forty-five patients undergoing AF ablation (73% paroxysmal, 27% persistent) were mapped at high density (18562 ± 2551 points) during SR (Rhythmia). Only bipolar EGMs with voltages above 0.5 mV were considered for analysis. When fractionation (> 40 ms and >4 deflections) was detected, we classified the mechanisms as slow conduction, wave-front collision, or a pivot point. The relationship between EGM duration and amplitude, and tissue anisotropy and slow conduction, was then studied using a computational model. RESULTS: Of the 45 left atria analyzed, 133 sites of EGM fragmentation were identified with voltages above 0.5 mV. The most frequent mechanism (64%) was slow conduction (velocity 0.45 m/s ± 0.2) with mean EGM voltage of 1.1 ± 0.5 mV and duration of 54.9 ± 9.4 ms. Wavefront collision was the second most frequent (19%), characterized by higher voltage (1.6 ± 0.9 mV) and shorter duration (51.3 ± 11.3 ms). Pivot points (9%) were associated with the highest degree of fractionation with 70.7 ± 6.6 ms and 1.8 ± 1 mV. In 10 sites (8%) fractionation was unexplained. The EGM duration was significantly different among the 3 mechanisms (p = .0351). CONCLUSION: In patients with a history of AF, EGM fractionation can occur at amplitudes > 0.5 mV when in SR in areas often considered not to be diseased tissue. The main mechanism of EGM fractionation is slow conduction, followed by wavefront collision and pivot sites.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Idoso , Simulação por Computador , Mapeamento Epicárdico , Feminino , Humanos , Itália , Masculino
3.
Heart Rhythm ; 19(1): 102-112, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34534699

RESUMO

BACKGROUND: Detailed effects of electrode size on electrograms (EGMs) have not been systematically examined. OBJECTIVES: We aimed to elucidate the effect of electrode size on EGMs and investigate an optimal configuration of electrode size and interelectrode spacing for gap detection and far-field reduction. METHODS: This study included 8 sheep in which probes with different electrode size and interelectrode spacing were epicardially placed on healthy, fatty, and lesion tissues for measurements. Between 3 electrode sizes (0.1 mm/0.2 mm/0.5 mm) with 3 mm spacing. As indices of capability in gap detection and far-field reduction, in different electrode sizes (0.1 mm/0.2 mm/0.5 mm) and interelectrode spacing (0.1 mm/0.2 mm/0.3 mm/0.5 mm/3 mm) and the optimized electrode size and interelectrode spacing were determined. Compared between PentaRay and the optimal probe determined in study 2. RESULTS: Study 1 demonstrated that unipolar voltage and the duration of EGMs increased as the electrode size increased in any tissue (P < .001). Bipolar EGMs had the same tendency in healthy/fat tissues, but not in lesions. Study 2 showed that significantly higher gap to lesion volume ratio and healthy to fat tissue voltage ratio were provided by a smaller electrode (0.2 mm or 0.3 mm electrode) and smaller spacing (0.1 mm spacing), but 0.3 mm electrode/0.1 mm spacing provided a larger bipolar voltage (P < .05). Study 3 demonstrated that 0.3 mm electrode/0.1 mm spacing provided less deflection with more discrete EGMs (P < .0001) with longer and more reproducible AF cycle length (P < .0001) compared to PentaRay. CONCLUSION: Electrode size affects both unipolar and bipolar EGMs. Catheters with microelectrodes and very small interelectrode spacing may be superior in gap detection and far-field reduction. Importantly, this electrode configuration could dramatically reduce artifactual complex fractionated atrial electrograms and may open a new era for AF mapping.


Assuntos
Eletrodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Animais , Ablação por Cateter , Modelos Animais de Doenças , Desenho de Equipamento , Feminino , Carneiro Doméstico
4.
Herzschrittmacherther Elektrophysiol ; 32(2): 274-284, 2021 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-34009451

RESUMO

Due to good results, increasing standardization and lack of equivalent alternatives, catheter ablation has been established as an increasingly common procedure in clinical routine. This article describes common and necessary puncture techniques in catheter ablation (puncture of the groin vessels, transseptal puncture, pericardial puncture) and represents a practical instruction for the catheter laboratory. This article is part of a series of manuscripts presenting topics of interventional electrophysiology in the course of electrophysiology training.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Eletrofisiologia Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Humanos , Punções
5.
Heart Rhythm ; 18(7): 1115-1121, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33812085

RESUMO

BACKGROUND: Little is known about persistent atrial fibrillation (AF) ablation in patients with cardiac laminopathy (CLMNA). OBJECTIVES: We aimed to characterize atrial electrophysiological properties and to assess the long-term outcomes of persistent AF ablation in patients with CLMNA. METHODS: All patients with CLMNA referred in our center for persistent AF ablation were retrospectively included. Left atrial (LA) volume, left atrial appendage (LAA) cycle length, interatrial conduction delay, and LA voltage amplitude were analyzed during the ablation procedure. Sinus rhythm maintenance and LA contractile function were assessed during long-term follow-up. RESULTS: From 2011 to 2020, 8 patients were included. The mean age was 47 ± 14 years, and 3 patients (38%) were women. The LA volume was 205.8 ± 43.7 mL; the LAA AF cycle length was 250.7 ± 85.6 ms; and the interatrial conduction delay was 296.5 ± 110.1 ms. Large low-voltage areas (>50% of the LA surface; <0.5 mV electrogram) were recorded in all 8 patients. Two patients had inadvertent LAA disconnection during ablation. All A waves recorded by pulsed Doppler in sinus rhythm were <30 cm/s before and after AF ablation. Early arrhythmia recurrence was recorded in 7 patients (87%) (time to recurrence 4 ± 4 months; 1.5 procedures per patient). After a mean follow-up of 4.4 ± 3.2 years, 4 patients underwent implantable cardioverter-defibrillator therapy for life-threatening ventricular arrhythmia and 3 patients finally underwent heart transplantation. CONCLUSION: Patients with persistent AF afflicted by CLMNA exhibit severe LA impairment because of large low-voltage areas, prolonged conduction velocity, and reduced contractile function. Ablation procedures have a limited effect with a high recurrence rate.


Assuntos
Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo/fisiologia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos
6.
J Cardiovasc Electrophysiol ; 31(7): 1640-1648, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32437007

RESUMO

BACKGROUND: No study to date has used high-density mapping to investigate the relationship between prior radiofrequency (RF) lesions for persistent atrial fibrillation (PsAF) ablation and subsequent atrial tachycardias (ATs). METHODS: From 41 consecutive patients who underwent AT ablation at a second procedure using an ultrahigh-density mapping system, 22 patients (38 ATs) were included as they also had complete maps with a multipolar catheter and three-dimensional (3D) mapping system at the time of the first PsAF ablation procedure. We, therefore, compared voltage maps from the first AF ablation procedure to those from the subsequent AT ablation procedure, as well as the lesion sets used for AF ablation vs the activation patterns in AT during the second procedure. RESULTS: In the 38 ATs, 211 of 285 analyzed atrial areas displayed low voltage area (LVA) (74%). Eighteen percent (38/211) existed before the index ablation for AF while 82% (173/211) were newly identified as LVA during the second procedure. Ninety-nine percent (172/173) of the newly developed LVA colocalized with RF lesions delivered for PsAF. Of the 38 ATs, 89.5% (34/38) AT circuits were associated with newly developed LVA due to RF lesions whilst 10.5% (4/38) AT circuits were associated with pre-existing LVA observed at the index procedure. No AT circuit was completely independent from index RF lesions in this series. CONCLUSIONS: Analysis of detailed 3D electroanatomical mapping demonstrates that most ATs after PsAF ablation are involving LVAs due to index RF lesions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
7.
JACC Clin Electrophysiol ; 5(12): 1459-1472, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31857047

RESUMO

OBJECTIVES: A new electroanatomic mapping system (Rhythmia, Boston Scientific, Marlborough, Massachusetts) using a 64-electrode mapping basket is now available; we systematically assessed its use in complex congenital heart disease (CHD). BACKGROUND: The incidence of atrial arrhythmias post-surgery for CHD is high. Catheter ablation has emerged as an effective treatment, but is hampered by limitations in the mapping system's ability to accurately define the tachycardia circuit. METHODS: Mapping and ablation data of 61 patients with CHD (35 males, age 45 ± 14 years) from 8 tertiary centers were reviewed. RESULTS: Causes were as follows: Transposition of Great Arteries (atrial switch) (n = 7); univentricular physiology (Fontans) (n = 8); Tetralogy of Fallot (n = 10); atrial septal defect (ASD) repair (n = 15); tricuspid valve (TV) anomalies (n = 10); and other (n = 11). The total number of atrial arrhythmias was 86. Circuits were predominantly around the tricuspid valve (n = 37), atriotomy scar (n = 10), or ASD patch (n = 4). Although the majority of peri-tricuspid circuits were cavo-tricuspid-isthmus dependent (n = 30), they could follow a complex route between the annulus and septal resection, ASD patch, coronary sinus, or atriotomy. Immediate ablation success was achieved in all but 2 cases; with follow-up of 12 ± 8 months, 7 patients had recurrence. CONCLUSIONS: We demonstrate the feasibility of the basket catheter for mapping complex CHD arrhythmias, including with transbaffle and transhepatic access. Although the circuits often involve predictable anatomic landmarks, the precise critical isthmus is often difficult to predict empirically. Ultra-high-density mapping enables elucidation of circuits in this complex anatomy and allows successful treatment at the isthmus with a minimal lesion set.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Cardiopatias Congênitas , Taquicardia , Adulto , Idoso , Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Desenho de Equipamento , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia/diagnóstico por imagem , Taquicardia/etiologia , Taquicardia/fisiopatologia
8.
J Am Heart Assoc ; 8(15): e012482, 2019 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-31378121

RESUMO

Background Fat deposition (FD) is part of the healing process after myocardial infarction. The characteristics of FD and its impact on the outcome in patients undergoing ventricular tachycardia (VT) ablation have not been thoroughly studied. Methods and Results We studied consecutive patients undergoing post-myocardial infarction VT ablation with pre-procedural cardiac computed tomography. FD was defined as intra-myocardial attenuation ≤ -30 HU on computed tomography. Clinical, anatomical, and post-procedural outcome was assessed in the overall population. Electrophysiological characteristics were assessed is a subgroup of patients with high-density electro-anatomical maps. Sixty-nine patients were included (66±12 years). FD was detected in 44 (64%) patients. The presence of FD related to scar age (odds ratio [OR]: 1.14 per year; P=0.001) and scar extent (OR: 1.27 per segment; P=0.02). On electro-anatomical maps, FD was characterized by lower bipolar amplitude (P<0.001) and prolonged electrogram duration (P<0.001). Although the proportion of local abnormal ventricular activation was similar (P=0.22), local abnormal ventricular activation showed lower amplitude (P<0.001) and were more delayed (P<0.001) in scars with FD. After a mean follow-up of 26 months, patients with FD experienced a worse outcome including all-cause mortality and VT recurrence (70% versus 28%, P log rank=0.009). On multivariate analysis, FD (hazard ratio=2.69; 95% CI, 1.12-6.46; P=0.027) and left ventricular systolic dysfunction (hazard ratio=2.57; 95% CI, 1.13-5.85; P=0.024) were independent predictors of adverse outcomes. Conclusions FD in patients with post-myocardial infarction VT undergoing catheter ablation relates to scar age and size and may be a marker of adverse outcomes including all-cause mortality and VT recurrence.


Assuntos
Tecido Adiposo , Ablação por Cateter , Cicatriz/etiologia , Cicatriz/fisiopatologia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Tecido Adiposo/patologia , Idoso , Cicatriz/patologia , Técnicas Eletrofisiológicas Cardíacas , Fenômenos Eletrofisiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Prognóstico , Resultado do Tratamento
9.
Card Electrophysiol Clin ; 11(3): 459-471, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31400870

RESUMO

Electrocardiographic imaging is a mapping technique aiming to noninvasively characterize cardiac electrical activity using signals collected from the torso to reconstruct epicardial potentials. Its efficacy has been demonstrated clinically, from mapping premature ventricular complexes and accessory pathways to of complex arrhythmias. Electrocardiographic imaging uses a standardized workflow. Signals should be checked manually to avoid automatic processing errors. Reentry is confirmed in the presence of local activation covering the arrhythmia cycle length. Focal breakthroughs demonstrate a QS pattern associated with centrifugal activation. Electrocardiographic imaging offers a unique opportunity to better understand the mechanism of cardiac arrhythmias and guide ablation.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Humanos
10.
J Cardiovasc Electrophysiol ; 30(9): 1644-1651, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31347223

RESUMO

BACKGROUND: Radiofrequency (RF) ablation is an established treatment for ventricular tachycardia (VT). However, the inability of current RF catheters to address deep or large substrate may explain most of the clinical failures. OBJECTIVES: The aim of this study is to assess the efficacy and safety of ablation in the left ventricle (LV) in sheep using a novel 8-Fr deflectable ablation catheter (Sphere-9; Affera, Inc) with a 9-mm expandable spherical monopolar irrigated RF tip vs a standard RF irrigated catheter (Biosense Webster, Diamond Bar, CA). The impact on tissue was assessed on local bipolar electrograms (from nine uniformly distributed mini surface electrodes and an internal central reference electrode), as well as on direct lesion measurement post mortem. METHODS AND RESULTS: Eleven sheep underwent LV endocardial ablation in healthy tissue using the Sphere-9 catheter (n = 6), or a conventional irrigated RF catheter (n = 5). Twenty lesions were created with the Sphere-9 (current limit: 2.7 A; temp. limit: 60°C; irrigation: 30 mL/min; and duration: 60-120 seconds). Local bipolar electrograms at the surface of the catheter disappeared during RF delivery in 17 of 20 (85%) lesions. The mean lesion volume was 1707 ± 771 mm 3 (length: 15.8 ± 3.3 mm; width: 11.6 ± 4.2 mm; and depth: 10.3 ± 2.9 mm). Twenty-five lesions were created with a standard RF irrigated catheter (power control 35 W; irrigation: 30 mL/min; duration: 60 seconds; volume 537 ± 398 mm 3 ; length: 8.2 ± 2.3 mm; width: 5.2 ± 1.8 mm; and depth: 5.5 ± 2.4 mm). The novel spherical RF catheter created significantly larger lesions ( P < .001 for measurements in all dimensions). There were no steam pops with the novel ablation catheter vs one with the conventional catheter. CONCLUSIONS: This novel spherical monopolar irrigated RF catheter creates lesions that are twice as large and deep as a standard irrigated RF catheter.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Ventrículos do Coração/cirurgia , Irrigação Terapêutica/instrumentação , Potenciais de Ação , Animais , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Modelos Animais , Carneiro Doméstico , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo
11.
Heart Rhythm ; 16(11): 1661-1668, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31207315

RESUMO

BACKGROUND: Wall thickness (WT) in post-myocardial infarction scar is heterogenous, with channels of relatively preserved thickness bordered by thinner scar. OBJECTIVE: This study sought to determine whether 3-dimensionally-reconstructed computed tomography (CT) channels correlate with electrophysiological isthmuses during ventricular tachycardia (VT). METHODS: We retrospectively studied 9 postinfarction patients (aged 57 ± 15 years, 1 female) with 10 complete VT activation maps (cycle length 429 ± 77ms) created using high-resolution mapping. Three-dimensionally-reconstructed WT maps from CT were merged with the activation map during sinus rhythm (SR) and VT. The relationship between WT and electrophysiological characteristics was analyzed. RESULTS: A total of 41 CT channels were identified (median 4 per patient), of median (range) length 21.2 mm (17.3-36.8 mm), width 9.0 mm (6.7-16.5 mm), and area 1.49 cm2(1.00-1.75 cm2). WT in the channel was significantly thicker in the center than in the edge (median 2.4 mm vs 1.5 mm, P < .0001). Of 3163 (2493-5960) mapping points in SR, 382 (191-1115) local abnormal ventricular activities (LAVAs) were identified. One patient had a maximal proportion of LAVAs in 3-4 mm, 3 patients in 2-3 mm, 2 in 1-2 mm, and 2 in 0-1 mm. The VT isthmuses of all 10 VTs corresponded with 1-4 CT channels. Twenty-one of the 41 CT channels (51.2%) corresponded to a VT isthmus (entrance, mid, or exit). Electrophysiological VT isthmuses were more likely to be associated with CT channels that were longer (P = .04, odds ratio [OR] 1.05/mm), thinner (but not less than 1 mm) (P = .03, OR 0.36/mm), or parallel to the mitral annulus (P = .07, OR 3.93). CONCLUSION: VT isthmuses were always found in CT channels (100% sensitivity), and half of CT channels hosted VT isthmuses (positive predictive value 51%). Longer and thinner (but >1 mm) CT channels were significantly associated with VT isthmuses.


Assuntos
Infarto do Miocárdio/complicações , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Tomografia Computadorizada por Raios X/métodos , Cicatriz/fisiopatologia , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
Circ Arrhythm Electrophysiol ; 12(6): e007293, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31122054

RESUMO

Background Catheter ablation of ventricular tachycardia (VT) in structural heart disease is challenging because of noninducibility or hemodynamic compromise. Ablation often depends on elimination of local abnormal ventricular activities (LAVAs) but which may be hidden in far-field signal. We investigated whether altering activation wavefront affects activation timing and LAVA characterization and allows a better understanding of isthmus anatomy. Methods Patients with ischemic cardiomyopathy underwent mapping using the ultra-high density Rhythmia system (Boston Scientific). Maps were generated for all stable VTs and with pacing from the atrium, right ventricular apex, and an left ventricular branch of the coronary sinus. Results Fifty-six paced maps and 23 VT circuits were mapped in 22 patients. In 79% of activation maps, there was ≥1 line of block in the paced conduction wavefront, with 93% having fixed block and 32% showing functional partial block. Bipolar scar was larger with atrial than right ventricular (31.7±18.5 versus 27.6±16.3 cm2, P=0.003) or left ventricular pacing (31.7±18.5 versus 27.0±19.2 cm2, P=0.009); LAVA areas were smaller with atrial than right ventricular (12.3±10.5 versus 18.4±11.0 cm2, P<0.001) or left ventricular pacing (12.3±10.5 versus 17.1±10.7 cm2, P<0.001). LAVA areas were larger with wavefront propagation perpendicular versus parallel to the line of block along isthmus boundaries (19.3±7.1 versus 13.6±7.4 cm2, P=0.01). All patients had successful VT isthmus ablation. In 11±8 months follow-up, 2 patients had a recurrence. Conclusions Wavefronts of conduction slowing/block may aid identification of critical isthmuses in unmappable VTs. Altering the activation wavefront leads to significant differences in conduction properties of myocardial tissue, along with scar and LAVA characterization. In patients where few LAVAs are identified during substrate mapping, using an alternate activation wavefront running perpendicular to the VT isthmus may increase sensitivity to detect arrhythmogenic substrate and critical sites for reentry.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Idoso , Estimulação Cardíaca Artificial , Ablação por Cateter/efeitos adversos , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
13.
Heart Rhythm ; 16(11): 1652-1660, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31004777

RESUMO

BACKGROUND: A novel "LUMIPOINT" software in the Rhythmia system (Boston Scientific) displays a histogram of activated area over the entire atrial tachycardia (AT) cycle length (CL) with a normalized score. OBJECTIVE: The purpose of this study was to examine whether the pattern of this global activation histogram (GAH) identified reentrant vs focal AT and whether a decrease in atrial activation area, shown as valleys in the GAH, identifies isthmuses. METHODS: One hundred eight activation maps of ATs (17 focal, 57 macroreentrant, 21 localized, 13 multiple loop) in 67 patients were reviewed retrospectively with the LUMIPOINT software. The ACTIVATION SEARCH feature highlighted the activated area in a given time period irrespective of the activation map. A 30-ms unit time interval was set, and the GAH patterns and electrophysiological properties of highlighted areas were examined. RESULTS: Focal ATs systematically displayed a plateau with GAH-Score <0.1 for at least 30% of the CL. Most reentrant ATs (90/91 [98.9%]) lacked this plateau and displayed activity covering the entire CL, with 2 [1-2] GAH-Valleys per tachycardia. Each GAH-Valley highlighted 1 [1-2] areas in the map. Among 264 highlighted areas, 198 (75.0%) represented slow conduction, 19 (7.2%) lines of block, 27 (10.2%) wavefront collision, 3 (1.1%) unknown, and 17 (6.4%) absence of activation in focal ATs. Practical ablation sites all matched one of the highlighted areas based on GAH-Valleys, and they corresponded better with areas highlighted by GAH-Score ≤0.2 (P <.0001). CONCLUSION: GAH shows focal vs reentrant mechanisms at first glance. Decrease in activated areas (displayed by GAH-Valleys) is mostly due to slow conduction and highlights areas of special interest, with 100% sensitivity for isthmus identification.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/fisiopatologia , Algoritmos , Ablação por Cateter , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software , Taquicardia Supraventricular/cirurgia
14.
JACC Clin Electrophysiol ; 5(4): 470-479, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-31000101

RESUMO

OBJECTIVES: This study reports the use of a novel "Lumipoint" algorithm in ventricular tachycardia (VT) ablation. BACKGROUND: Automatic mapping systems aid rapid acquisition of activation maps. However, they may annotate farfield rather than nearfield signal in low voltage areas, making maps difficult to interpret. The Lumipoint algorithm analyzes the complete electrogram tracing and therefore includes nearfield signals in its analysis. METHODS: Twenty-two patients with ischemic cardiomyopathy and 5 with dilated cardiomyopathy underwent mapping using the ultra-high density Rhythmia system. Lumipoint algorithms were applied retrospectively. RESULTS: In all left ventricular substrate maps, changing the window of interest to the post-QRS phase automatically identified late potentials. In 25 of 27 left ventricular VT activation maps, a minimum spatial window of interest correctly identified the VT isthmus as seen by the manually annotated map, entrainment, and response to ablation. In 6 maps, the algorithm identified the isthmus where the standard automatically annotated map did not. CONCLUSIONS: The Lumipoint algorithm automatically highlights areas with electrograms having specific characteristics or timings. This can identify late and fractionated potentials and regions that exhibit discontinuous activation, as well as the isthmus of a VT circuit. These features may enhance human interpretation of the electrogram signals during a case, particularly where the circuit lies in partial scar with low amplitude nearfield signals and potentially allow a more targeted ablation strategy.


Assuntos
Algoritmos , Técnicas Eletrofisiológicas Cardíacas/métodos , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/diagnóstico , Idoso , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia
15.
Europace ; 21(Supplement_1): i27-i33, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30801128

RESUMO

Successful mapping and ablation of ventricular tachycardias remains a challenging clinical task. Whereas conventional entrainment and activation mapping was for many years the gold standard to identify reentrant circuits in ischaemic ventricular tachycardia ablation procedures, substrate mapping has become the cornerstone of ventricular tachycardia ablation. In the last decade, technology has dramatically improved. In parallel to high-density automated mapping, cardiac imaging and image integration tools are increasingly used to assess the structural ventricular tachycardia substrate. The aim of this review is to describe the technologies underlying these new mapping systems and to discuss their possible role in providing new insights into identification and visualization of reentrant tachycardia mechanisms.


Assuntos
Técnicas de Imagem Cardíaca , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/anatomia & histologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Humanos
16.
Heart Rhythm ; 16(4): 553-561, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30389441

RESUMO

BACKGROUND: Ablation of complex atrial tachycardias (ATs) is difficult. OBJECTIVE: The purpose of this study was to elucidate a mechanism underlying the behavior of ATs during ablation and to create an algorithm to predict it. METHODS: An algorithm predicting termination/conversion of AT and the second AT circuit associated with the ablation site was developed from 52 index reentrant AT high-resolution activation maps in 45 patients (retrospective phase). First, the wavefront collision site was identified. Then, the N or N-1 beat was defined for each collision associated with the ablation site. When the AT involved wavefront collision solely between N-1/N-1 (N/N) beats, the AT would terminate during ablation. Conversely, when the AT included wavefront collision between N/N-1 beats, the index AT would convert to a second AT. The algorithm was then prospectively tested in 172 patients with 194 ATs (127 anatomic macroreentrant ATs [AMATs], 44 non-AMATs, 23 multiple-loop ATs). RESULTS: Accuracy in predicting AT termination/conversion and the second AT circuit was 95.9% overall, 96.1% in AMATs, 95.5% in non-AMATs, and 95.7% in multiple-loop ATs. Median (25th-75th percentile) absolute variation between predicted and actually observed cycle length of the second AT was 6 (4-9) ms. Prediction failure occurred in 8 ATs; either the second AT used an unmapped chamber or structure in the index map (n = 7) or a line of block was misinterpreted as very slow conduction in the index map (n = 1). CONCLUSION: A simple mechanism underlies the behavior of ATs during ablation, even in complex ATs. With a simple algorithm using high-resolution mapping, AT termination/conversion and the second AT circuit and cycle length may be predicted from the index activation map.


Assuntos
Ablação por Cateter , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/classificação
17.
Int J Comput Assist Radiol Surg ; 14(2): 291-300, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30370499

RESUMO

PURPOSE: Clinical cardiac electrophysiology (EP) is concerned with diagnosis and treatment of cardiac arrhythmia describing abnormality or perturbation in the normal activation sequence of the myocardium. With the recent introduction of lowest dose X-ray imaging protocol for EP procedures, interventional image enhancement has gained crucial importance for the well-being of patients as well as medical staff. METHODS: In this paper, we introduce a novel method to detect and track different EP catheter electrodes in lowest dose fluoroscopic sequences based on [Formula: see text]-sparse coding and online robust PCA (ORPCA). Besides being able to work on real lowest dose sequences, the underlying methodology achieves simultaneous detection and tracking of three main EP catheters used during ablation procedures. RESULTS: We have validated our algorithm on 16 lowest dose fluoroscopic sequences acquired during real cardiac ablation procedures. In addition to expert labels for 2 sequences, we have employed a crowdsourcing strategy to obtain ground truth labels for the remaining 14 sequences. In order to validate the effect of different training data, we have employed a leave-one-out cross-validation scheme yielding an average detection rate of [Formula: see text]. CONCLUSION: Besides these promising quantitative results, our medical partners also expressed their high satisfaction. Being based on [Formula: see text]-sparse coding and online robust PCA (ORPCA), our method advances previous approaches by being able to detect and track electrodes attached to multiple different catheters.


Assuntos
Arritmias Cardíacas/diagnóstico , Cateteres Cardíacos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Algoritmos , Cateterismo , Fluoroscopia/métodos , Humanos
18.
J Cardiovasc Electrophysiol ; 30(2): 195-204, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30288836

RESUMO

BACKGROUND: The relationship between the local electrograms (EGMs) and wall thickness (WT) heterogeneity within infarct scars has not been thoroughly described. The relationship between WT and voltages and substrates for ventricular tachycardia (VT) was examined. METHODS: In 12 consecutive patients with myocardial infarction and VT, WT, defined by a multidetector computed tomography, and voltage were compared. In multicomponent EGMs, amplitudes of both far- and near-field components were manually measured, and the performance of the three-dimensional-mapping system automatic voltage measurement was assessed. RESULTS: Of 15 748 points acquired, 2677 points within 5 mm of the endocardial surface were analyzed. In total, 909 (34.0%) multicomponent EGMs were identified; 785 (86.4%) and 883 (97.1%) were distributed in the WT less than 4 and 5 mm, respectively. Far-field EGM voltages increased linearly from 0.14 mV (0.08-0.28 mV) in the WT: 0 to 1 mm to 0.70 mV (0.43-2.62 mV) in the WT: 4 to 5 mm (ρ = 0.430; P < 0.001), and a significant difference was demonstrated between any two WT-groups (P ≤ 0.001). In contrast, near-field EGM voltages varied from 0.27 mV (0.11-0.44 mV) in the WT: 0 to 1 mm to 0.29 mV (0.17-0.53 mV) in the WT: 4 to 5 mm with a poorer correlation (ρ = 0.062, P = 0.04). The proportion of points where the system automatically measured the voltage on near-field EGMs increased from less than 10% in areas of WT: 4 to 5 mm to 50% in areas less than 2 mm. Of 21 VTs observed, seven hemodynamically stable VTs were mapped and terminated in WT: 1 to 4 mm area. CONCLUSIONS: Although far-field voltages gradually increase with the WT, near-field does not. The three-dimensional-mapping system preferentially annotates the near-field components in thinner areas (center of the scar) and the far-field component in thicker areas when building a voltage map. Critical sites of VT are distributed in WT: 1 to 4 mm areas.


Assuntos
Potenciais de Ação , Cicatriz/diagnóstico por imagem , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Infarto do Miocárdio/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Cicatriz/complicações , Cicatriz/fisiopatologia , Feminino , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia
19.
J Cardiovasc Electrophysiol ; 28(6): 636-641, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28316148

RESUMO

BACKGROUND: For persistent atrial fibrillation (AF) ablation, different strategies including complex fractionated atrial electrograms (CFAE) ablation and linear lesions (LL) have been used in addition to pulmonary vein isolation (PVI). However, it is still a matter of debate if extended substrate modification improves long-term outcome. The aim of this study was to determine the benefit of LL in addition to PVI and CFAE ablation regarding freedom from arrhythmia recurrence in patients with persistent AF. METHODS: The study was a prospective randomized trial including 90 patients with persistent and longstanding persistent AF. All patients underwent PVI and CFAE ablation. If AF did not terminate to atrial tachycardia (AT) or sinus rhythm, patients were randomized to direct current cardioversion (Group 1; n = 45) or LL (Group 2; n = 45). Primary endpoint was freedom from any atrial arrhythmia off antiarrhythmic drugs at 12 months. (NCT02059369) RESULTS: Baseline characteristics were similar between the two groups with more than half of the patients having structural heart disease. The primary endpoint was reached in 37% in Group 1 (G1) and 16% in Group 2 (G2; P = 0.03). After a total number of 1.4 ± 0.5 (G1) versus 1.7 ± 0.4 (G2; P = 0.01) procedures, freedom from any arrhythmia was reached in 54% in G1 and 65% in G2 (P = 0.35). CONCLUSION: In persistent AF ablation, LL in addition to PVI and CFAE show a significantly lower success rate after a single procedure compared to PVI and CFAE. Following LL, significantly more patients needed a reablation to reach a similar success rate during a 12-month follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Intervalo Livre de Doença , Feminino , Alemanha , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 28(1): 109-114, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27653802

RESUMO

BACKGROUND: Contact-force (CF) sensing catheters are increasingly used in electrophysiological procedures due to their efficacy and safety profile. As data about the accuracy of fiberoptic CF technology are scarce, we sought to quantify it using in vitro experiments. METHODS AND RESULTS: A force sensor was built with a flexible membrane to allow exact reference force measurements for each set of experiments. A TactiCath Quartz (TCQ) ablation catheter was brought in contact with the force sensor membrane in order to compare the TCQ force measurements to sensor reference force measurements. Measurements were performed at different tip angles (0°/perpendicular contact, 45°, 90°/parallel contact), with fluid irrigation, different degrees of catheter deflection, and using a sheath. The accuracy of the TCQ force measurements was 0.9 ± 0.9 g (0°), 0.8 ± 0.8 g (45°) and 1.2 ± 1.3 g (90°), 0.8 ± 0.7 g (irrigation), 0.8 ± 0.8 g (deflection), and 0.8 ± 0.9 g (sheath); this was not significantly different among all experimental conditions. The precision was ≤3.8%. CONCLUSION: CF measurements using a fiberoptic sensing technology show a high level of accuracy and precision, without being significantly influenced by tip angle, fluid irrigation, catheter deflection or use of a sheath.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Tecnologia de Fibra Óptica/instrumentação , Transdutores de Pressão , Calibragem , Cateterismo Cardíaco/normas , Cateteres Cardíacos/normas , Técnicas Eletrofisiológicas Cardíacas/normas , Desenho de Equipamento , Tecnologia de Fibra Óptica/normas , Teste de Materiais , Padrões de Referência , Reprodutibilidade dos Testes , Irrigação Terapêutica , Transdutores de Pressão/normas