Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
PLoS One ; 12(3): e0175094, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28362859

RESUMO

BACKGROUND: The blood to anticoagulant ratio is standardized according to the physiological calcium concentration in blood samples conventionally used for hemostasis testing. Specifically, one fixed volume of 0.109 mmol/L sodium citrate is added to 9 volumes of blood. Since little is known about the impact of hypercalcemia on the calcium-binding capacity of citrate, this study was planned to investigate the effect of experimental hypercalcemia on routine hemostasis testing. METHODS: Fifteen pooled citrated plasmas with matching lithium-heparin pooled plasma from patients with different values of prothrombin time (PT) were divided in three aliquots of 0.6mL each. The first paired aliquots of both citrate and lithium-heparin plasma were supplemented with 60µL of saline, the second paired aliquots with 30µL of saline and 30µL of calcium chloride and the third paired aliquots with 60µL of calcium chloride. Total and ionized calcium was measured in all aliquots of citrate and lithium-heparin plasma, whereas PT, activated partial thromboplastin time (APTT) and fibrinogen were measured in citrate plasma aliquots. RESULTS: Total calcium concentration gradually increased in both lithium-heparin and citrate plasma aliquots 2 and 3 compared to baseline aliquot 1. The concentration of ionized calcium also gradually increased in lithium-heparin plasma aliquots 2 and 3, whereas it remained immeasurable (i.e., <0.10 mmol/L) in all citrate plasma aliquots. No significant differences were observed for values of PT, APTT and fibrinogen in citrate plasma aliquots 2 and 3 compared to the baseline aliquot 1, with a mean bias was always comprised within the desirable quality specifications derived from biological variability data. CONCLUSION: Hypercalcemia, up to severe hypercalcemia does not generate significant bias in results of first-line coagulations tests, so that hypothetical consideration of adjusting citrate-blood ratio is unjustified in hypercalcemic patients.


Assuntos
Hemostasia , Hipercalcemia/sangue , Anticoagulantes/sangue , Coagulação Sanguínea/fisiologia , Ácido Cítrico/sangue , Feminino , Fibrinogênio/metabolismo , Heparina/sangue , Humanos , Lítio/sangue , Masculino , Tempo de Tromboplastina Parcial , Tempo de Protrombina
2.
Clin Chem Lab Med ; 51(12): 2281-5, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23846149

RESUMO

BACKGROUND: The potential for cross-contamination of additives among evacuated blood tubes has led to the development of the order of draw. This practice, however, is mainly based on scarce, anecdotal, and mostly outdated literature data. Therefore, the goal of this investigation was to definitely establish whether or not the indication of a specific order of draw is still justified. METHODS: The study population consisted of 57 outpatients referred to the outpatient oral anticoagulant (OA) clinic of the Academic Hospital of Verona and 58 healthy volunteers enrolled from the laboratory personnel. In OA outpatients, one serum tube was collected immediately after needle insertion, followed by a buffered sodium citrate tube and another serum tube. In the healthy volunteers, one serum tube was collected immediately after needle insertion, followed by a potassium-ethylenediaminetetraacetic acid (K2-EDTA) tube and another serum tube. After separation, the serum was tested for potassium, sodium, calcium, magnesium, and phosphorus in the first and second serum tubes. RESULTS: No significant difference could be observed between the first and the second serum tubes for any of the parameters. The bias calculated with Bland-Altman plots did not achieve statistical significance when the serum tube was collected after either a K2-EDTA or a sodium citrate tube. CONCLUSIONS: According to our data, revision of national and supranational recommendations on blood collection by venipuncture should consider that the order of draw exerts a negligible effect on sample quality, and this aspect should no longer be considered a quality criterion when evaluating the performance of phlebotomists.


Assuntos
Anticoagulantes/sangue , Flebotomia/métodos , Cálcio/sangue , Humanos , Magnésio/sangue , Flebotomia/normas , Fósforo/sangue , Potássio/sangue , Sódio/sangue , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA