1.
Circ Arrhythm Electrophysiol ; 15(6): e010502, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35622437

RESUMO

BACKGROUND: Surgical ablation for atrial fibrillation (AF) can be effective, yet has mixed results. It is unclear which endocardial lesions delivered as part of hybrid therapy' will best augment surgical lesion sets in individual patients. We addressed this question by systematically mapping AF endocardially after surgical ablation and relating findings to early recurrence, then performing tailored endocardial ablation as part of hybrid therapy. METHODS: We studied 81 consecutive patients undergoing epicardial surgical ablation (stage 1 hybrid), of whom 64 proceeded to endocardial catheter mapping and ablation (stage 2). Stage 2 comprised high-density mapping of pulmonary vein (PV) or posterior wall (PW) reconnections, low-voltage zones (LVZs), and potential localized AF drivers. We related findings to postsurgical recurrence of AF. RESULTS: Mapping at stage 2 revealed PW isolation reconnection in 59.4%, PV isolation reconnection in 28.1%, and LVZ in 42.2% of patients. Postsurgical recurrence of AF occurred in 36 patients (56.3%), particularly those with long-standing persistent AF (P=0.017), but had no relationship to reconnection of PVs (P=0.53) or PW isolation (P=0.75) when compared with those without postsurgical recurrence of AF. LVZs were more common in patients with postsurgical recurrence of AF (P=0.002), long-standing persistent AF (P=0.002), advanced age (P=0.03), and elevated CHA2DS2-VASc (P=0.046). AF mapping revealed 4.4±2.7 localized focal/rotational sites near and also remote from PV or PW reconnection. After ablation at patient-specific targets, arrhythmia freedom at 1 year was 81.0% including and 73.0% excluding previously ineffective antiarrhythmic medications. CONCLUSIONS: After surgical ablation, AF may recur by several modes particularly related to localized mechanisms near low voltage zones, recovery of posterior wall or pulmonary vein isolation, or other sustaining mechanisms. LVZs are more common in patients at high clinical risk for recurrence. Patient-specific targeting of these mechanisms yields excellent long-term outcomes from hybrid ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
2.
Heart Rhythm ; 16(5): 717-723, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30465902

RESUMO

BACKGROUND: The postpacing interval (PPI) minus the tachycardia cycle length (TCL) is frequently used to investigate tachycardias. However, a variety of issues (eg, failure to entrain, decremental conduction, and oscillating TCLs) can make interpretation of the PPI-TCL challenging. OBJECTIVE: The purpose of this study was to investigate a novel maneuver to confirm the PPI-TCL value without using either the ventricular PPI or the TCL interval and to assess the ability of this maneuver to identify decremental conduction and differentiate supraventricular tachycardias. METHODS: We analyzed 77 intracardiac recordings from patients (age 25 ± 20 years; 40 female) who underwent catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) or orthodromic reciprocating tachycardia (ORT) with a concealed pathway. We calculated the PPI-TCL, the AH-corrected PPI-TCL, and estimated the PPI-TCL using "dual-chamber entrainment" calculated as [PPIV - TCL = Stim(A→V) + Stim(V→A) - PPIA]. RESULTS: The PPI-TCL calculated by dual-chamber entrainment highly correlated with the observed and AH-corrected PPI-TCL (R2 = 0.79 and 0.96, respectively; P <.001]. A dual-chamber entrainment PPI-TCL value of 80 ms correctly differentiated all AVNRT from septal ORT cases, whereas the standard PPI-TCL and AH-corrected PPI-TCL methods were incorrect in 14% and 6% of cases, respectively. Dual-chamber entrainment identified 3 ± 10 ms of additional decremental conduction beyond AH prolongation, including 4 pathways with significant (>10 ms) decrement. CONCLUSION: Dual-chamber entrainment estimates the PPI-TCL value without using either the ventricular PPI or the TCL interval. This maneuver adjusts for all decremental conduction, including within concealed pathways, where a dual-chamber entrainment PPI-TCL value >80 ms favors AVNRT over ORT. This maneuver can be used to verify the observed PPI-TCL value in challenging cases.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Reciprocante , Taquicardia Supraventricular/diagnóstico , Adolescente , Adulto , Diagnóstico Diferencial , Precisão da Medição Dimensional , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Reprodutibilidade dos Testes , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/fisiopatologia