Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Medicinas Complementares
Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 98(30): e16603, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31348305

RESUMO

Neuroimaging in the context of examining atypical parkinsonian tauopathies is an evolving matter. Positron emission tomography and single photon emission computed tomography (SPECT) bring tools, which may be reasonable in supplementary examination, however, cannot be interpreted as a criterion standard for correct diagnosis. The aim of this observational study was to assess the differentiating potential of perfusion SPECT in 3 types of atypical parkinsonisms: multiple system atrophy parkinsonian type (MSA-P), corticobasal syndrome (CBS), and progressive supranuclear palsy (PSP). The study was carried out using the comparison of standard deviations of perfusion in patients from these 3 groups. Data obtained from 10 patients with clinical diagnosis MSA-P, 14 patients with CBS and 21 patients with PSP, which were analyzed using Tukey honest significant difference post-hoc test, revealed significant differences of perfusion P < .05 between MSA-P and PSP within the cerebellum and thalamus. No significant differences between CBS and PSP were observed.


Assuntos
Atrofia de Múltiplos Sistemas/diagnóstico , Paralisia Supranuclear Progressiva/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Cerebelo/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Atrofia de Múltiplos Sistemas/diagnóstico por imagem , Transtornos Parkinsonianos/diagnóstico por imagem , Paralisia Supranuclear Progressiva/diagnóstico por imagem , Tálamo/diagnóstico por imagem
2.
Cardiol J ; 25(1): 81-86, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28653315

RESUMO

BACKGROUND: The number of patients with implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy and defibrillator (CRT-D) is growing. This results in high workloads for centers performing standard controls (SC) of these systems. Medtronic CareLink Express® (MCLE) is a solution enabling remote controls (RC) of implantable devices. In cases of detecting arrhythmias or device malfunctioning, it automatically generates alarms transmitted to the controlling physician. The objective of the study was to evaluate the effectiveness of alarms generated by MCLE in identification of patients that require clinically significant intervention during SC. METHODS: A total of 119 patients (age 64 ± 14, 17 women) implanted with ICD/CRT-D were included in the trial. Device reprogramming or pharmacological treatment modifications during SC were as-sessed as significant if they were required for optimal clinical management of the patient (effectiveness of antiarrhythmic and resynchronization therapy, also patient safety). Analysis of generated alarms was then performed to assess the effectiveness (sensitivity and specificity) of MCLE in identifying patients that require changes in therapy. RESULTS: Data from 129 transmissions and 129 subsequent SCs were analyzed. 179 alarms were recorded during 96 (74%) transmissions. A total of 333 program changes of implanted devices took place during 107 (83%) SCs. Device reprogramming was considered clinically significant in 27 cases Additionaly, 13 pharmacological treatment modifications were performed. Sensitivity and specificity of alarms generated by MCLE with regards to identification of patients requiring clinically significant intervention was 87% and 31%, respectively. Finally, a statistically significant difference was observed in the number of clinically significant interventions among patients with and without MCLE alarms (33 [86.8%] vs. 5 [13.2%], p = 0.037). CONCLUSIONS: Medtronic CareLink Express® is an RC system enabling high-sensitivity supervision of patients with cardiac.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Terapia por Estimulação Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Telemetria/instrumentação , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA