Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38581328

RESUMO

Objective: The measurement of the right and left axillary arteries and aortic arch and their vessels by multi-row spiral CT angiography provides the basis for clinical catheter selection and depth for axillary artery placement. This study reported the clinical experience of 7 patients who successfully underwent ultrasound-guided percutaneous axillary artery cannulation for veno-arterial extracorporeal membrane oxygenation (VA-ECMO). Methods: Patients who had CT angiography of the thoracic aorta at our institution between January 2020 and March 2022 were assessed for eligibility and included. The diameters of the cephalic trunk (D1), right common carotid artery (D2), right axillary artery (D3), left common carotid artery (D4), left axillary artery opening (D5), right axillary artery cannulation length (L1), and left axillary artery cannulation length (L2) were measured. The tangential angles α, ß, and γ of the cephalic trunk, left common carotid artery and left subclavian and aorta was measured using an automatic angle-forming tool. The decision to use a 15F cannula for ultrasound-guided percutaneous axillary artery cannulation in veno-arterial extracorporeal membrane oxygenation (VA-ECMO) aims to achieve optimal vascular access. This cannula size strikes a balance, providing sufficient blood flow rates for ECMO support while minimizing the risk of complications associated with larger cannulas. Precise measurements of arterial dimensions, including the cephalic trunk, common carotid arteries, and axillary arteries, play a crucial role in guiding catheter selection and determining the depth of axillary artery placement. These measurements allow for tailored approaches based on individual patient characteristics, enhancing the safety and efficacy of the intervention. Additionally, measuring tangential angles (α, ß, and γ) provides insights into arterial alignment, optimizing the cannula trajectory for efficient blood flow. The use of an automatic angle-forming tool enhances measurement precision, contributing to procedural accuracy, minimizing complications, and ensuring the success of ultrasound-guided percutaneous axillary artery cannulation. In summary, the choice of a 15F cannula and precise measurements are essential components of the methodology, emphasizing safety, efficacy, and personalized approaches in VA-ECMO. From March to June 2022, 7 patients (6 males and 1 female) in our intensive care medicine department underwent successful ultrasound-guided percutaneous axillary artery cannulation for VA-ECMO with 15F cannula, including 3 cases with extracorporeal cardiopulmonary resuscitation (ECPR) and 4 cases with circulatory collapse. Results: 292 patients met the study criteria, 215 males and 77 females, with a mean age of 67.2±14.2 years. The measurements showed that D1 was (13.1±2.0) mm, D2 was (8.8±2.5) mm, D3 was (6.1±1.2) mm, D4 was (8.3±3.5) mm, D5 was (6.1±1.1) mm, L1 was (114.1±17.8) mm, and L2 was (128.4±20.2) mm. The tangential angles α of the cephalic trunk left common carotid artery and left subclavian artery to the aorta were (43.8°±17.1°), ß was (50.7°±14.8°), and γ was (62.4°±19.1°). Males had significantly wider D3 and D5, longer L1 and L2, and smaller gamma angles than females (P < .05). Three ECPR cases showed no recovery of the spontaneous heartbeat with femoral artery cannulation for VA-ECMO but recovered spontaneous heartbeat after axillary artery cannulation for VA-ECMO was adopted. The measurements in this study have important implications for veno-arterial extracorporeal membrane oxygenation (VA-ECMO) procedures. They provide crucial information about arterial dimensions, including the cephalic trunk, common carotid arteries, and axillary arteries. This information guides clinicians in selecting catheters and determining the ideal depth for percutaneous axillary artery cannulation during ECMO interventions. Notable gender differences in arterial dimensions highlight the need for personalized approaches in ECMO procedures. Customizing catheter choices and cannulation depth based on individual patient characteristics, informed by these measurements, improves the safety and effectiveness of the intervention. The measured tangential angles (α, ß, and γ) offer insights into arterial alignment, crucial for optimizing cannula trajectory and ensuring proper alignment for efficient blood flow. The use of an automatic angle-forming tool enhances measurement precision, contributing to procedural accuracy and minimizing the risk of complications during ECMO procedures. In summary, these measurements directly enhance the precision and safety of VA-ECMO procedures, underscoring the importance of personalized approaches based on individual anatomical variations and improving overall intervention success and outcomes. Conclusion: Ultrasound-guided percutaneous axillary artery cannulation for VA-ECMO with a 15F cannula is clinically feasible. Axillary artery cannulation for VA-ECMO contributes to the restoration of spontaneous heartbeat in ECPR patients more than femoral artery cannulation, and the possible mechanism is a better improvement of coronary blood flow. However, the study has limitations, including a modest sample size and a single-center, retrospective design, impacting its generalizability. To validate and extend these findings, further research with larger and diverse cohorts, including prospective investigations, is necessary to ensure their applicability across various clinical settings and patient demographics in VA-ECMO.

2.
Chin J Integr Med ; 21(3): 229-33, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24142260

RESUMO

OBJECTIVE: To observe the protective effects of safflor Injection (SI) and extract of Ginkgo biloba (EGB) on lung ischemia-reperfusion injury (LIRI) and investigate its mechanism. METHODS: In vivo rabbit model of LIRI was reconstructed. Forty rabbits were randomly and equally divided into four groups: sham-operation group (sham group), ischemia-reperfusion group (model group), ischemia-reperfusion plus SI group (safflor group) and ischemia-reperfusion plus EGB injection group (EGB group). Malondialdehyde (MDA) content, superoxide dismutase (SOD) and xanthine oxidase (XO) activity in serum were measured. The wet/dry weight ratio (W/D) of the lung tissue and activity of myeloperoxidase (MPO) were also tested. Ultrastructure change of the lung tissue was observed by the electron microscope. The expression of intercellular adhesion molecule-1 (ICAM-1) was measured by immunohistochemistry (IHC). RESULTS: In the model group, MDA and XO increased and SOD decreased in serum compared with the sham group (P<0.01). The values of W/D, MPO and ICAM-1 of the model group were higher than those of the sham group (P<0.01), but those of the safflor group and EGB group were significantly lower than those of the model group (P<0.01). The IHC demonstrated that ICAM-1 expression in lung tissue of the model group was significantly higher than those of the safflor group (P<0.01). Compared with safflor group, in the EGB group MDA, XO, MPO decreased, SOD and ICAM-1 expression increased (P<0.05), but the change of W/D was not statistically significant (P>0.05). CONCLUSIONS: SI and EGB may attenuate LIRI through antioxidation, inhibition of neutrophil aggregation and down-regulation of ICAM-1 expression. But EGB had more effect on the antioxidation, while SI did better on regulating ICAM-1 expression.


Assuntos
Ginkgo biloba/química , Pulmão/irrigação sanguínea , Extratos Vegetais/uso terapêutico , Substâncias Protetoras/uso terapêutico , Traumatismo por Reperfusão/tratamento farmacológico , Óleo de Cártamo/uso terapêutico , Animais , Feminino , Imuno-Histoquímica , Injeções , Molécula 1 de Adesão Intercelular/metabolismo , Pulmão/patologia , Masculino , Malondialdeído/metabolismo , Extratos Vegetais/administração & dosagem , Extratos Vegetais/farmacologia , Substâncias Protetoras/administração & dosagem , Substâncias Protetoras/farmacologia , Coelhos , Traumatismo por Reperfusão/sangue , Óleo de Cártamo/administração & dosagem , Óleo de Cártamo/farmacologia , Superóxido Dismutase/sangue , Xantina Oxidase/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA