1.
Spine Deform ; 5(4): 272-276, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28622903

RESUMO

STUDY DESIGN: Retrospective cohort. OBJECTIVES: To determine if the use of cell saver reduces overall blood costs in adult spinal deformity (ASD) surgery. SUMMARY OF BACKGROUND DATA: Recent studies have questioned the clinical value of cell saver during spine procedures. METHODS: ASD patients enrolled in a prospective, multicenter surgical database who had complete preoperative and surgical data were identified. Patients were stratified into (1) cell saver available during surgery, but no intraoperative autologous infusion (No Infusion group), or (2) cell saver available and received autologous infusion (Infusion group). RESULTS: There were 427 patients in the Infusion group and 153 in the No infusion group. Patients in both groups had similar demographics. Mean autologous infusion volume was 698 mL. The Infusion group had a higher percentage of EBL relative to the estimated blood volume (42.2%) than the No Infusion group (19.6%, p < .000). Allogeneic transfusion was more common in the Infusion group (255/427, 60%) than the No Infusion group (67/153, 44%, p = .001). The number of allogeneic blood units transfused was also higher in the Infusion group (2.4) than the No Infusion group (1.7, p = .009). Total blood costs ranged from $396 to $2,146 in the No Infusion group and from $1,262 to $5,088 in the Infusion group. If the cost of cell saver blood was transformed into costs of allogeneic blood, total blood costs for the Infusion group would range from $840 to $5,418. Thus, cell saver use yielded a mean cost savings ranging from $330 to $422 (allogeneic blood averted). Linear regression showed that after an EBL of 614 mL, cell saver becomes cost-efficient. CONCLUSION: Compared to transfusing allogeneic blood, cell saver autologous infusion did not reduce the proportion or the volume of allogeneic transfusion for patients undergoing surgery for adult spinal deformity. The use of cell saver becomes cost-efficient above an EBL of 614 mL, producing a cost savings of $330 to $422. LEVEL OF EVIDENCE: Level III.


Assuntos
Transfusão de Sangue Autóloga/economia , Transfusão de Sangue/economia , Anormalidades Congênitas/cirurgia , Coluna Vertebral/anormalidades , Coluna Vertebral/cirurgia , Idoso , Perda Sanguínea Cirúrgica/prevenção & controle , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Transfusão de Sangue/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Sangue Operatório/economia , Hemorragia Pós-Operatória/economia , Estudos Prospectivos , Estudos Retrospectivos , Coluna Vertebral/diagnóstico por imagem
2.
Spine (Phila Pa 1976) ; 38(4): E217-22, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23197016

RESUMO

STUDY DESIGN: Retrospective review. OBJECTIVE: To identify risk factors for cell saver transfusion in lumbar spinal surgery and determine if cell saver transfusions affected intraoperative or postoperative transfusion rates. SUMMARY OF BACKGROUND DATA: Cell saver has been used to minimize allogeneic blood transfusion in lumbar spinal surgery. Conflicting reports exist, which call into question the efficacy of cell saver use. METHODS: We reviewed medical records of randomly selected patients who underwent posterolateral fusion with or without transforaminal interbody fusion from July 2010 to June 2011. Transfusion rates and transfusion-related complications were determined. Binary logistic regression was performed to identify risk factors for use of autologous cell saver transfusion. RESULTS: There were 178 females and 107 males, with a mean age of 57.2 years. Of the 285 cases, 39 had no cell saver available, 147 had cell saver available but no autologous blood was recovered or transfused and 99 had an autologous cell saver transfusion. Patients who had cell saver transfusion had a higher rate of intraoperative allogeneic blood transfusion (52%) compared with those who did not (22%). There was no significant difference in the rate of postoperative transfusions or transfusion-related reactions between patients who did and did not have cell saver transfusion. Patient's age, smoking status, American Society of Anesthesiologists grade, use of anticoagulants preoperatively, primary or revision surgery, iliac crest bone graft harvest, anesthesiologist, or surgeon had no significant effect on cell saver infusion. Body mass index (odds ratio [OR] = 1.06), number of posterolateral fusion levels fused (OR = 2.50), and number of transforaminal interbody fusions performed (OR = 2.41) were independent risk factors for the use of autologous cell saver transfusion. CONCLUSION: Body mass index, multi-level fusion and transforaminal interbody fusion result in increased use of autologous cell saver transfusion in lumbar spinal surgery. Use of autologous cell saver transfusion did not reduce the requirement for intraoperative or postoperative allogeneic blood transfusion. LEVEL OF EVIDENCE: 2.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue Autóloga , Vértebras Lombares/cirurgia , Recuperação de Sangue Operatório/instrumentação , Fusão Vertebral , Transfusão de Sangue Autóloga/efeitos adversos , Índice de Massa Corporal , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Recuperação de Sangue Operatório/efeitos adversos , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/terapia , Estudos Retrospectivos , Fatores de Risco , Fusão Vertebral/efeitos adversos , Resultado do Tratamento