Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Interv Card Electrophysiol ; 49(3): 299-306, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28643171

RESUMO

PURPOSE: Elimination of the negative component of the unipolar atrial electrogram is a reliable indicator of the creation of a transmural lesion. Contact-force (CF) sensing technology has the potential to increase the durability of pulmonary vein isolation (PVI). In the present multicenter study, we assessed the 2-year sinus rhythm (SR) maintenance rate in patients with paroxysmal atrial fibrillation (PAF) after PVI guided by these two approaches. METHODS: Two hundred fifteen consecutive PAF patients (62.1 ± 10.1 years, 65 women) were prospectively enrolled. All patients underwent PVI under CARTO guidance according to a systematic contiguous "point-by-point" approach, using radiofrequency energy, and a CF externally irrigated ablation catheter with the goal of at least 10g (ideally 20g) of force. The ablation endpoint of each individual lesion was elimination of the negative component of the unipolar atrial signal. The procedural endpoint was PVI with bidirectional block. RESULTS: All PVs were successfully isolated. After 30 min of waiting time, 35 patients (16%) had PV reconnection and in all of them, the PVs were re-isolated. Two years after a single ablation procedure, 187 patients (87%) remained arrhythmia free, without anti-arrhythmic drugs. Of the 28 patients presenting with AF recurrence, 25 had PV reconnection and underwent repeat PVI while in the remaining 3 patients, all four PVs were isolated and extra-PV triggers were identified. There were six groin hematomas and one transient ischemic attack. CONCLUSIONS: Unipolar atrial signal analysis combined with CF sensing ensures a robust 2-year SR maintenance rate in the treatment of PAF. Clinical trial registration-URL: http://www.clinicaltrials.gov . Unique identifier: NCT02520960.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Veias Pulmonares/cirurgia , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Recidiva , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
2.
Heart Rhythm ; 9(7): 1025-30, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22342863

RESUMO

BACKGROUND: Catheter ablation of persistent atrial fibrillation (AF) is associated with longer procedure times and lower long-term success rates than that of paroxysmal AF. OBJECTIVE: To test the hypothesis that restoration/maintenance of sinus rhythm (SR) preablation would facilitate AF termination and improve outcomes in patients with persistent AF. METHODS: We conducted a 2-group cohort study of consecutive patients with persistent AF and SR restored for at least 1 month prior to ablation (SR group; n = 40) and controls matched by age, sex, and AF duration (control group; n = 40). Radiofrequency stepwise catheter ablation was performed in AF for both groups (induced and spontaneous, respectively). Success was defined as freedom from atrial tachyarrhythmia without antiarrhythmic drugs beyond 1 year of follow-up. RESULTS: During the index ablation procedure, AF cycle length was longer in the SR group than in the control group (183 ± 32 ms vs 166 ± 20 ms; P = .06), suggestive of reverse remodeling. In the SR group, AF more frequently terminated during ablation (95.0% vs 77.5%; P <.05) and required less extensive ablation of complex fractionated electrograms (40.0% vs 87.5%; P <.001) and linear lesions (42.5% vs 82.5%; P <.001). Mean procedural (199.8 ± 69.8 minutes vs 283.5 ± 72.3 minutes; P <.001), fluoroscopy (51.0 ± 24.9 minutes vs 96.3 ± 32.1 minutes; P <.001), and radiofrequency energy delivery (47.5 ± 18.9 minutes vs 97.0 ± 30.6 minutes; P <.001) times were shorter in the SR group. Clinical success rates were similar between groups for first (55.0% vs 45.0%; P = .28) and last (80.0% vs 70.0%; P = .28) procedures, during similar follow-up periods (21.1 ± 9.7 months). CONCLUSIONS: Restoration of SR prior to catheter ablation for persistent AF whenever possible decreases the extent of ablation with the same high clinical efficacy.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
3.
Heart Rhythm ; 7(9): 1216-23, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20206323

RESUMO

BACKGROUND: Ablation of long-standing persistent atrial fibrillation (AF) remains challenging, with a lower success rate than paroxysmal AF. A reliable ablation endpoint has not been demonstrated yet, although AF termination during ablation may be associated with higher long-term maintenance of sinus rhythm (SR). OBJECTIVE: The purpose of this study was to determine whether the method of AF termination during ablation predicts mode of recurrence or long-term outcome. METHODS: Three hundred six patients with long-standing persistent AF, free of antiarrhythmic drugs (AADs), undergoing a first radiofrequency ablation (pulmonary vein [PV] antrum isolation and complex fractionated atrial electrograms) were prospectively included. Organized atrial tachyarrhythmias (AT) that occurred during AF ablation were targeted. AF termination mode during ablation was studied in relation to other variables (characteristics of arrhythmia recurrence, redo procedures, the use of adenosine/isoproterenol for redo, and comparison of focal versus macroreentrant ATs). Long-term maintenance of SR was assessed during the follow-up. RESULTS: During AF ablation, six of 306 patients converted directly to SR, 172 patients organized into AT (with 38 of them converting in SR with further ablation), and 128 did not organize or terminate and were cardioverted. Two hundred eleven of 306 patients (69%) maintained in long-term SR without AADs after a mean follow-up of 25 +/- 6.9 months, with no statistical difference between the various AF termination modes during ablation. Presence or absence of organization during ablation clearly predicted the predominant mode of recurrence, respectively, AT or AF (P = .022). Among the 74 redo ablation patients, 24 patients (32%) had extra PV triggers revealed by adenosine/isoproterenol. Termination of focal ATs was correlated with higher long-term success rate (24/29, 83%) than termination of macroreentrant ATs (20/35, 57%; P = .026). CONCLUSION: AF termination during ablation (conversion to AT or SR) could predict the mode of arrhythmia recurrence (AT vs. AF) but did not impact the long-term SR maintenance after one or two procedures. AT termination with further ablation did not correlate with better long-term outcome, except with focal ATs, for which termination seems critical.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Monitorização Intraoperatória/métodos , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Eur Heart J ; 24(22): 2061-9, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14613743

RESUMO

AIMS: Risk-stratification of asymptomatic Brugada Syndrome (BS) patients remains a key-issue. A typical spontaneous BS-ECG pattern and ventricular tachycardia (VT)/ventricular fibrillation (VF) inducibility are two recognized risk markers. The aim of the study was to identify additional risk markers in asymptomatic BS. METHODS AND RESULTS: We have compared Holter recordings in symptomatic and in asymptomatic patients with BS. Heart rate variability (HRV), QT-interval rate-dependence and ST-segment elevation (ST-SE) were analysed. The study population included 47 BS patients (M=36, mean age=45+/-13 years) with a malignant ventricular arrhythmia in 11 cases, an unexplained syncope in 10 cases and no symptoms in the remaining 26 cases. A typical spontaneous BS-ECG was present in 21 cases and a drug-induced BS-ECG in 26 cases. A downward trend of the time domain variables of HRV was observed. During the nocturnal period, standard deviation (SD) of the 5min averaged NN intervals (SDANN) (46+/-13 vs 57+/-18ms, P=0.02) and ultra low frequency component (3287+/-2312 vs 5030+/-3270 ms(2), P=0.04) were significantly lower in symptomatic versus asymptomatic patients. In contrast, no difference was found in QT-interval rate dependence and in ST-SE. At multivariate logistic regression, VT/VF inducibility, typical spontaneous BS-ECG and a decreased nocturnal SDANN were associated with arrhythmic events (P=0.003). CONCLUSIONS: A decreased nocturnal SDANN was an independent marker of arrhythmic events in these BS patients.


Assuntos
Bloqueio de Ramo/diagnóstico , Ritmo Circadiano , Morte Súbita Cardíaca/prevenção & controle , Adulto , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia Ambulatorial/métodos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Medição de Risco/métodos , Fatores de Risco , Processamento de Sinais Assistido por Computador , Síndrome , Fibrilação Ventricular/diagnóstico
5.
Circulation ; 108(8): 925-8, 2003 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-12925452

RESUMO

BACKGROUND: The long-QT and Brugada syndromes are important substrates of malignant ventricular arrhythmia. The feasibility of mapping and ablation of ventricular arrhythmias in these conditions has not been reported. METHODS AND RESULTS: Seven patients (4 men; age, 38+/-7 years; 4 with long-QT and 3 with Brugada syndrome) with episodes of ventricular fibrillation or polymorphic ventricular tachycardia and frequent isolated or repetitive premature beats were studied. These premature beats were observed to trigger ventricular arrhythmias and were localized by mapping the earliest endocardial activity. In 4 patients, premature beats originated from the peripheral right (1 Brugada) or left (3 long-QT) Purkinje conducting system and were associated with variable Purkinje-to-muscle conduction times (30 to 110 ms). In the remaining 3 patients, premature beats originated from the right ventricular outflow tract, being 25 to 40 ms ahead of the QRS. The accuracy of mapping was confirmed by acute elimination of premature beats after 12+/-6 minutes of radiofrequency applications. During a follow-up of 17+/-17 months using ambulatory monitoring and defibrillator memory interrogation, no patients had recurrence of symptomatic ventricular arrhythmia but 1 had persistent premature beats. CONCLUSIONS: Triggers from the Purkinje arborization or the right ventricular outflow tract have a crucial role in initiating ventricular fibrillation associated with the long-QT and Brugada syndromes. These can be eliminated by focal radiofrequency ablation.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter , Síndrome do QT Longo/diagnóstico , Fibrilação Ventricular/diagnóstico , Adulto , Arritmias Cardíacas/complicações , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/cirurgia , Masculino , Síncope/etiologia , Síndrome , Resultado do Tratamento , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA