Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 21(1): 288, 2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112089

RESUMO

BACKGROUND: Atrioventricular (AV) delay could affect AV and ventricular synchrony in cardiac resynchronization therapy (CRT). Strategies to optimize AV delay according to optimal AV synchrony (AVopt-AV) or ventricular synchrony (AVopt-V) would potentially be discordant. This study aimed to explore a new AV delay optimization algorithm guided by electrograms to obtain the maximum integrative effects of AV and ventricular resynchronization (opt-AV). METHODS: Forty-nine patients with CRT were enrolled. AVopt-AV was measured through the Ritter method. AVopt-V was obtained by yielding the narrowest QRS. The opt-AV was considered to be AVopt-AV or AVopt-V when their difference was < 20 ms, and to be the AV delay with the maximal aortic velocity-time integral between AVopt-AV and AVopt-V when their difference was > 20 ms. RESULTS: The results showed that sensing/pacing AVopt-AV (SAVopt-AV/PAVopt-AV) were correlated with atrial activation time (Pend-As/Pend-Ap) (P < 0.05). Sensing/pacing AVopt-V (SAVopt-V/PAVopt-V) was correlated with the intrinsic AV conduction time (As-Vs/Ap-Vs) (P < 0.01). The percentages of patients with more than 20 ms differences between SAVopt-AV/PAVopt-AV and SAVopt-V/PAVopt-V were 62.9% and 57.1%, respectively. Among them, opt-AV was linearly correlated with SAVopt-AV/PAVopt-AV and SAVopt-V/PAVopt-V. The sensing opt-AV (opt-SAV) = 0.1 × SAVopt-AV + 0.4 × SAVopt-V + 70 ms (R2 = 0.665, P < 0.01) and the pacing opt-AV (opt-PAV) = 0.25 × PAVopt-AV + 0.5 × PAVopt-V + 30 ms (R2 = 0.560, P < 0.01). CONCLUSION: The SAVopt-AV/PAVopt-AV and SAVopt-V/PAVopt-V were correlated with the atrial activation time and the intrinsic AV conduction interval respectively. Almost half of the patients had a > 20 ms difference between SAVopt-AV/PAVopt-AV and SAVopt-V/PAVopt-V. The opt-AV could be estimated based on electrogram parameters.


Assuntos
Potenciais de Ação , Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , China , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 30(5): 642-650, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30680820

RESUMO

INTRODUCTION: Right ventricular outflow tract ventricular arrhythmias (RVOT VAs) often originate in the voltage-transitional zone. The target electrogram could be compromised by the architecture of the roving catheter. Mini-electrodes could improve the mapping resolution, especially in low-voltage areas. The aim was to assess the electrophysiological characteristics of the earliest activation site (EAS) of RVOT VAs during mapping using mini-electrodes. METHODS AND RESULTS: Twenty-seven patients with RVOT-type VAs were mapped using Orion mini-electrodes and the Rhythmia mapping system. Bipolar and unipolar electrograms were analyzed and compared with conventional ablation catheter recordings. Twenty-five patients (25 of 27) were successfully mapped and ablated at the RVOT. At the EAS, all 25 (100%) patients exhibited local sharp potentials (spiky potential) at the VAs, and 88% (22 of 25) individuals showed reverse late potentials in adjacent sinus beats on the bipolar mini-electrode recordings. Related unipolar electrograms manifested 20% "q-plateau-QS," 76% "gross QS," and 4% "late QS" patterns related to spiky potential voltages and advanced times. Compared with electrograms recorded by ablation catheter, bipolar mini-electrode recordings exhibited significantly shorter spiky potential durations (P = 0.001) and a significantly increased incidence of the reverse late potentials (P = 0.041). Unipolar mini-electrode recordings had a lower incidence ratio of "late QS" patterns (P = 0.039). CONCLUSION: Compared with ablation catheter mapping, mini-electrodes improved the mapping resolution of the EAS of RVOT VAs and exhibited shorter spiky potential durations and reduced incidence of "later QS" unipolar patterns.


Assuntos
Potenciais de Ação , Arritmias Cardíacas/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Microeletrodos , Adulto , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/cirurgia , Ablação por Cateter , Desenho de Equipamento , Feminino , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA