Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37428890

RESUMO

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia , Átrios do Coração , Resultado do Tratamento
2.
Heart Rhythm ; 19(1): 102-112, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34534699

RESUMO

BACKGROUND: Detailed effects of electrode size on electrograms (EGMs) have not been systematically examined. OBJECTIVES: We aimed to elucidate the effect of electrode size on EGMs and investigate an optimal configuration of electrode size and interelectrode spacing for gap detection and far-field reduction. METHODS: This study included 8 sheep in which probes with different electrode size and interelectrode spacing were epicardially placed on healthy, fatty, and lesion tissues for measurements. Between 3 electrode sizes (0.1 mm/0.2 mm/0.5 mm) with 3 mm spacing. As indices of capability in gap detection and far-field reduction, in different electrode sizes (0.1 mm/0.2 mm/0.5 mm) and interelectrode spacing (0.1 mm/0.2 mm/0.3 mm/0.5 mm/3 mm) and the optimized electrode size and interelectrode spacing were determined. Compared between PentaRay and the optimal probe determined in study 2. RESULTS: Study 1 demonstrated that unipolar voltage and the duration of EGMs increased as the electrode size increased in any tissue (P < .001). Bipolar EGMs had the same tendency in healthy/fat tissues, but not in lesions. Study 2 showed that significantly higher gap to lesion volume ratio and healthy to fat tissue voltage ratio were provided by a smaller electrode (0.2 mm or 0.3 mm electrode) and smaller spacing (0.1 mm spacing), but 0.3 mm electrode/0.1 mm spacing provided a larger bipolar voltage (P < .05). Study 3 demonstrated that 0.3 mm electrode/0.1 mm spacing provided less deflection with more discrete EGMs (P < .0001) with longer and more reproducible AF cycle length (P < .0001) compared to PentaRay. CONCLUSION: Electrode size affects both unipolar and bipolar EGMs. Catheters with microelectrodes and very small interelectrode spacing may be superior in gap detection and far-field reduction. Importantly, this electrode configuration could dramatically reduce artifactual complex fractionated atrial electrograms and may open a new era for AF mapping.


Assuntos
Eletrodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Animais , Ablação por Cateter , Modelos Animais de Doenças , Desenho de Equipamento , Feminino , Carneiro Doméstico
3.
Pacing Clin Electrophysiol ; 44(6): 1075-1084, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33932234

RESUMO

BACKGROUND: Conventional bipolar electrodes (CBE) may be suboptimal to detect local abnormal ventricular activities (LAVAs). Microelectrodes (ME) may improve the detection of LAVAs. This study sought to elucidate the detectability of LAVAs using ME compared with CBE in patients with scar-related ventricular tachycardia (VT). METHODS: We included consecutive patients with structural heart disease who underwent radiofrequency catheter ablation for scar-related VT using either of the following catheters equipped with ME: QDOTTM or IntellaTip MIFITM. Detection field of LAVA potentials were classified as three types: Type 1 (both CBE and ME detected LAVA), Type 2 (CBE did not detect LAVA while ME did), and Type 3 (CBE detected LAVA while ME did not). RESULTS: In 16 patients (68 ± 16 years; 14 males), 260 LAVAs electrograms (QDOT = 72; MIFI = 188) were analyzed. Type 1, type 2, and type 3 detections were 70.8% (QDOT, 69.4%; MIFI, 71.3%), 20.0% (QDOT, 23.6%; MIFI, 18.6%) and 9.2% (QDOT, 6.9%; MIFI, 10.1%), respectively. The LAVAs amplitudes detected by ME were higher than those detected by CBE in both catheters (QDOT: ME 0.79 ± 0.50 mV vs. CBE 0.41 ± 0.42 mV, p = .001; MIFI: ME 0.73 ± 0.64 mV vs. CBE 0.38 ± 0.36 mV, p < .001). CONCLUSIONS: ME allow to identify 20% of LAVAs missed by CBE. ME showed higher amplitude LAVAs than CBE. However, 9.2% of LAVAs can still be missed by ME.


Assuntos
Cicatriz/fisiopatologia , Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Idoso , Ablação por Cateter , Feminino , Humanos , Masculino , Microeletrodos , Estudos Retrospectivos , Taquicardia Ventricular/cirurgia
4.
J Cardiovasc Electrophysiol ; 31(7): 1640-1648, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32437007

RESUMO

BACKGROUND: No study to date has used high-density mapping to investigate the relationship between prior radiofrequency (RF) lesions for persistent atrial fibrillation (PsAF) ablation and subsequent atrial tachycardias (ATs). METHODS: From 41 consecutive patients who underwent AT ablation at a second procedure using an ultrahigh-density mapping system, 22 patients (38 ATs) were included as they also had complete maps with a multipolar catheter and three-dimensional (3D) mapping system at the time of the first PsAF ablation procedure. We, therefore, compared voltage maps from the first AF ablation procedure to those from the subsequent AT ablation procedure, as well as the lesion sets used for AF ablation vs the activation patterns in AT during the second procedure. RESULTS: In the 38 ATs, 211 of 285 analyzed atrial areas displayed low voltage area (LVA) (74%). Eighteen percent (38/211) existed before the index ablation for AF while 82% (173/211) were newly identified as LVA during the second procedure. Ninety-nine percent (172/173) of the newly developed LVA colocalized with RF lesions delivered for PsAF. Of the 38 ATs, 89.5% (34/38) AT circuits were associated with newly developed LVA due to RF lesions whilst 10.5% (4/38) AT circuits were associated with pre-existing LVA observed at the index procedure. No AT circuit was completely independent from index RF lesions in this series. CONCLUSIONS: Analysis of detailed 3D electroanatomical mapping demonstrates that most ATs after PsAF ablation are involving LVAs due to index RF lesions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
5.
JACC Clin Electrophysiol ; 6(4): 448-460, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32327079

RESUMO

OBJECTIVES: The goal of this study was to assess the value of a stepwise, image-guided ablation approach in patients with cardiomyopathy and predominantly intramural scar. BACKGROUND: Few reports have focused on catheter-based ventricular tachycardia (VT) ablation strategies in patients with predominantly intramural scar. METHODS: The study included patients with predominantly intramural scar undergoing VT ablation. A stepwise strategy was performed consisting of a localized ablation guided by conventional mapping criteria followed by a more extensive ablation if VT remained inducible. The extensive ablation was guided by the location and extent of intramural scarring on delayed enhanced-cardiac magnetic resonance imaging. A historical cohort who did not undergo additional extensive ablation was identified for comparison. A novel measurement, the scar depth index (SDI), indicating the percent area of the scar at a given depth, was correlated with outcomes. RESULTS: Forty-two patients who underwent stepwise ablation (median age 61 years [interquartile range: 55 to 69 years], 35 male patients, median left ventricular ejection fraction 36.0% [25.0% to 55.0%], ischemic [n = 4] or nonischemic cardiomyopathy [n = 38]) were followed up for a median of 17 months (8 to 36 months). A stepwise approach resulted in a 1-year freedom from VT, death, or cardiac transplantation of 76% (32 of 42). Patients who underwent additional extensive ablation had a lower risk of events than a clinically similar historical cohort (N = 19) (hazard ratio: 0.30; 95% CI: 0.13 to 0.68; p < 0.004). SDI>5mm was associated with worse long-term outcomes (hazard ratio: 1.03; 95% CI: 1.01 to 1.06%; p = 0.03), SDI>5mm >16.5% was associated with failed ablation (area under the curve: 0.84; 95% CI: 0.71 to 0.97). CONCLUSIONS: Stepwise ablation using delayed enhanced-cardiac magnetic resonance guidance is a novel approach to VT ablation in patients with predominantly intramural scarring. The SDI correlates with immediate procedural and long-term outcomes.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Cicatriz/patologia , Cicatriz/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Taquicardia Ventricular/cirurgia , Função Ventricular Esquerda
6.
JACC Clin Electrophysiol ; 5(12): 1459-1472, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31857047

RESUMO

OBJECTIVES: A new electroanatomic mapping system (Rhythmia, Boston Scientific, Marlborough, Massachusetts) using a 64-electrode mapping basket is now available; we systematically assessed its use in complex congenital heart disease (CHD). BACKGROUND: The incidence of atrial arrhythmias post-surgery for CHD is high. Catheter ablation has emerged as an effective treatment, but is hampered by limitations in the mapping system's ability to accurately define the tachycardia circuit. METHODS: Mapping and ablation data of 61 patients with CHD (35 males, age 45 ± 14 years) from 8 tertiary centers were reviewed. RESULTS: Causes were as follows: Transposition of Great Arteries (atrial switch) (n = 7); univentricular physiology (Fontans) (n = 8); Tetralogy of Fallot (n = 10); atrial septal defect (ASD) repair (n = 15); tricuspid valve (TV) anomalies (n = 10); and other (n = 11). The total number of atrial arrhythmias was 86. Circuits were predominantly around the tricuspid valve (n = 37), atriotomy scar (n = 10), or ASD patch (n = 4). Although the majority of peri-tricuspid circuits were cavo-tricuspid-isthmus dependent (n = 30), they could follow a complex route between the annulus and septal resection, ASD patch, coronary sinus, or atriotomy. Immediate ablation success was achieved in all but 2 cases; with follow-up of 12 ± 8 months, 7 patients had recurrence. CONCLUSIONS: We demonstrate the feasibility of the basket catheter for mapping complex CHD arrhythmias, including with transbaffle and transhepatic access. Although the circuits often involve predictable anatomic landmarks, the precise critical isthmus is often difficult to predict empirically. Ultra-high-density mapping enables elucidation of circuits in this complex anatomy and allows successful treatment at the isthmus with a minimal lesion set.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Cardiopatias Congênitas , Taquicardia , Adulto , Idoso , Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Desenho de Equipamento , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia/diagnóstico por imagem , Taquicardia/etiologia , Taquicardia/fisiopatologia
7.
J Am Heart Assoc ; 8(15): e012482, 2019 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-31378121

RESUMO

Background Fat deposition (FD) is part of the healing process after myocardial infarction. The characteristics of FD and its impact on the outcome in patients undergoing ventricular tachycardia (VT) ablation have not been thoroughly studied. Methods and Results We studied consecutive patients undergoing post-myocardial infarction VT ablation with pre-procedural cardiac computed tomography. FD was defined as intra-myocardial attenuation ≤ -30 HU on computed tomography. Clinical, anatomical, and post-procedural outcome was assessed in the overall population. Electrophysiological characteristics were assessed is a subgroup of patients with high-density electro-anatomical maps. Sixty-nine patients were included (66±12 years). FD was detected in 44 (64%) patients. The presence of FD related to scar age (odds ratio [OR]: 1.14 per year; P=0.001) and scar extent (OR: 1.27 per segment; P=0.02). On electro-anatomical maps, FD was characterized by lower bipolar amplitude (P<0.001) and prolonged electrogram duration (P<0.001). Although the proportion of local abnormal ventricular activation was similar (P=0.22), local abnormal ventricular activation showed lower amplitude (P<0.001) and were more delayed (P<0.001) in scars with FD. After a mean follow-up of 26 months, patients with FD experienced a worse outcome including all-cause mortality and VT recurrence (70% versus 28%, P log rank=0.009). On multivariate analysis, FD (hazard ratio=2.69; 95% CI, 1.12-6.46; P=0.027) and left ventricular systolic dysfunction (hazard ratio=2.57; 95% CI, 1.13-5.85; P=0.024) were independent predictors of adverse outcomes. Conclusions FD in patients with post-myocardial infarction VT undergoing catheter ablation relates to scar age and size and may be a marker of adverse outcomes including all-cause mortality and VT recurrence.


Assuntos
Tecido Adiposo , Ablação por Cateter , Cicatriz/etiologia , Cicatriz/fisiopatologia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Tecido Adiposo/patologia , Idoso , Cicatriz/patologia , Técnicas Eletrofisiológicas Cardíacas , Fenômenos Eletrofisiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Prognóstico , Resultado do Tratamento
8.
Card Electrophysiol Clin ; 11(3): 459-471, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31400870

RESUMO

Electrocardiographic imaging is a mapping technique aiming to noninvasively characterize cardiac electrical activity using signals collected from the torso to reconstruct epicardial potentials. Its efficacy has been demonstrated clinically, from mapping premature ventricular complexes and accessory pathways to of complex arrhythmias. Electrocardiographic imaging uses a standardized workflow. Signals should be checked manually to avoid automatic processing errors. Reentry is confirmed in the presence of local activation covering the arrhythmia cycle length. Focal breakthroughs demonstrate a QS pattern associated with centrifugal activation. Electrocardiographic imaging offers a unique opportunity to better understand the mechanism of cardiac arrhythmias and guide ablation.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Humanos
9.
Europace ; 21(10): 1484-1493, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31280323

RESUMO

AIMS: Atrial fibrosis contributes to arrhythmogenesis in atrial fibrillation and can be detected by MRI or electrophysiological mapping. The current study compares the spatial correlation between delayed enhancement (DE) areas to low-voltage areas (LVAs) and to arrhythmogenic areas with spatio-temporal dispersion (ST-Disp) or continuous activity (CA) in atrial fibrillation (AF). METHODS AND RESULTS: Sixteen patients with persistent AF (nine long-standing) underwent DE-magnetic resonance imaging (1.25 mm × 1.25 mm × 2.5 mm) prior to pulmonary vein isolation. Left atrial (LA) voltage mapping was acquired in AF and the regional activation patterns of 7680 AF wavelets were analysed. Sites with ST-Disp or CA were characterized (voltage, duration) and their spatial relationship to DE areas and LVAs <0.5 mV was assessed. Delayed enhancement areas and LVAs covered 55% and 24% (P < 0.01) of total LA surface, respectively. Delayed enhancement area was present at 61% of LVAs, whereas low voltage was present at 28% of DE areas. Most DE areas (72%) overlapped with atrial high-voltage areas (>0.5 mV). Spatio-temporal dispersion and CA more frequently co-localized with LVAs than with DE areas (78% vs. 63%, P = 0.02). Regional bipolar voltage of ST-Disp vs. CA was 0.64 ± 0.47 mV vs. 0.58 ± 0.51 mV. All 28 ST-Disp and 56 CA areas contained electrograms with prolonged duration (115 ± 14 ms) displaying low voltage (0.34 ± 0.11 mV). CONCLUSION: A small portion of DE areas and LVAs harbour the arrhythmogenic areas displaying ST-Disp or CA. Most arrhythmogenic activities co-localized with LVAs, while there was less co-localization with DE areas. There is an important mismatch between DE areas and LVAs which needs to be considered when used as target for catheter ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo/fisiologia , Átrios do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Meglumina/farmacologia , Miocárdio/patologia , Compostos Organometálicos/farmacologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Meios de Contraste/farmacologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Fibrose/patologia , Gadolínio , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
10.
J Cardiovasc Electrophysiol ; 30(9): 1644-1651, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31347223

RESUMO

BACKGROUND: Radiofrequency (RF) ablation is an established treatment for ventricular tachycardia (VT). However, the inability of current RF catheters to address deep or large substrate may explain most of the clinical failures. OBJECTIVES: The aim of this study is to assess the efficacy and safety of ablation in the left ventricle (LV) in sheep using a novel 8-Fr deflectable ablation catheter (Sphere-9; Affera, Inc) with a 9-mm expandable spherical monopolar irrigated RF tip vs a standard RF irrigated catheter (Biosense Webster, Diamond Bar, CA). The impact on tissue was assessed on local bipolar electrograms (from nine uniformly distributed mini surface electrodes and an internal central reference electrode), as well as on direct lesion measurement post mortem. METHODS AND RESULTS: Eleven sheep underwent LV endocardial ablation in healthy tissue using the Sphere-9 catheter (n = 6), or a conventional irrigated RF catheter (n = 5). Twenty lesions were created with the Sphere-9 (current limit: 2.7 A; temp. limit: 60°C; irrigation: 30 mL/min; and duration: 60-120 seconds). Local bipolar electrograms at the surface of the catheter disappeared during RF delivery in 17 of 20 (85%) lesions. The mean lesion volume was 1707 ± 771 mm 3 (length: 15.8 ± 3.3 mm; width: 11.6 ± 4.2 mm; and depth: 10.3 ± 2.9 mm). Twenty-five lesions were created with a standard RF irrigated catheter (power control 35 W; irrigation: 30 mL/min; duration: 60 seconds; volume 537 ± 398 mm 3 ; length: 8.2 ± 2.3 mm; width: 5.2 ± 1.8 mm; and depth: 5.5 ± 2.4 mm). The novel spherical RF catheter created significantly larger lesions ( P < .001 for measurements in all dimensions). There were no steam pops with the novel ablation catheter vs one with the conventional catheter. CONCLUSIONS: This novel spherical monopolar irrigated RF catheter creates lesions that are twice as large and deep as a standard irrigated RF catheter.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Ventrículos do Coração/cirurgia , Irrigação Terapêutica/instrumentação , Potenciais de Ação , Animais , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Modelos Animais , Carneiro Doméstico , Irrigação Terapêutica/efeitos adversos , Fatores de Tempo
11.
Heart Rhythm ; 16(11): 1661-1668, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31207315

RESUMO

BACKGROUND: Wall thickness (WT) in post-myocardial infarction scar is heterogenous, with channels of relatively preserved thickness bordered by thinner scar. OBJECTIVE: This study sought to determine whether 3-dimensionally-reconstructed computed tomography (CT) channels correlate with electrophysiological isthmuses during ventricular tachycardia (VT). METHODS: We retrospectively studied 9 postinfarction patients (aged 57 ± 15 years, 1 female) with 10 complete VT activation maps (cycle length 429 ± 77ms) created using high-resolution mapping. Three-dimensionally-reconstructed WT maps from CT were merged with the activation map during sinus rhythm (SR) and VT. The relationship between WT and electrophysiological characteristics was analyzed. RESULTS: A total of 41 CT channels were identified (median 4 per patient), of median (range) length 21.2 mm (17.3-36.8 mm), width 9.0 mm (6.7-16.5 mm), and area 1.49 cm2(1.00-1.75 cm2). WT in the channel was significantly thicker in the center than in the edge (median 2.4 mm vs 1.5 mm, P < .0001). Of 3163 (2493-5960) mapping points in SR, 382 (191-1115) local abnormal ventricular activities (LAVAs) were identified. One patient had a maximal proportion of LAVAs in 3-4 mm, 3 patients in 2-3 mm, 2 in 1-2 mm, and 2 in 0-1 mm. The VT isthmuses of all 10 VTs corresponded with 1-4 CT channels. Twenty-one of the 41 CT channels (51.2%) corresponded to a VT isthmus (entrance, mid, or exit). Electrophysiological VT isthmuses were more likely to be associated with CT channels that were longer (P = .04, odds ratio [OR] 1.05/mm), thinner (but not less than 1 mm) (P = .03, OR 0.36/mm), or parallel to the mitral annulus (P = .07, OR 3.93). CONCLUSION: VT isthmuses were always found in CT channels (100% sensitivity), and half of CT channels hosted VT isthmuses (positive predictive value 51%). Longer and thinner (but >1 mm) CT channels were significantly associated with VT isthmuses.


Assuntos
Infarto do Miocárdio/complicações , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Tomografia Computadorizada por Raios X/métodos , Cicatriz/fisiopatologia , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
Heart Rhythm ; 16(11): 1652-1660, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31004777

RESUMO

BACKGROUND: A novel "LUMIPOINT" software in the Rhythmia system (Boston Scientific) displays a histogram of activated area over the entire atrial tachycardia (AT) cycle length (CL) with a normalized score. OBJECTIVE: The purpose of this study was to examine whether the pattern of this global activation histogram (GAH) identified reentrant vs focal AT and whether a decrease in atrial activation area, shown as valleys in the GAH, identifies isthmuses. METHODS: One hundred eight activation maps of ATs (17 focal, 57 macroreentrant, 21 localized, 13 multiple loop) in 67 patients were reviewed retrospectively with the LUMIPOINT software. The ACTIVATION SEARCH feature highlighted the activated area in a given time period irrespective of the activation map. A 30-ms unit time interval was set, and the GAH patterns and electrophysiological properties of highlighted areas were examined. RESULTS: Focal ATs systematically displayed a plateau with GAH-Score <0.1 for at least 30% of the CL. Most reentrant ATs (90/91 [98.9%]) lacked this plateau and displayed activity covering the entire CL, with 2 [1-2] GAH-Valleys per tachycardia. Each GAH-Valley highlighted 1 [1-2] areas in the map. Among 264 highlighted areas, 198 (75.0%) represented slow conduction, 19 (7.2%) lines of block, 27 (10.2%) wavefront collision, 3 (1.1%) unknown, and 17 (6.4%) absence of activation in focal ATs. Practical ablation sites all matched one of the highlighted areas based on GAH-Valleys, and they corresponded better with areas highlighted by GAH-Score ≤0.2 (P <.0001). CONCLUSION: GAH shows focal vs reentrant mechanisms at first glance. Decrease in activated areas (displayed by GAH-Valleys) is mostly due to slow conduction and highlights areas of special interest, with 100% sensitivity for isthmus identification.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/fisiopatologia , Algoritmos , Ablação por Cateter , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software , Taquicardia Supraventricular/cirurgia
14.
J Cardiovasc Electrophysiol ; 30(5): 727-740, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30847990

RESUMO

INTRODUCTION: Pulmonary vein (PV) reconnection is frequent in patients showing atrial fibrillation (AF) recurrence after PV isolation (PVI). Its detection with cardiac magnetic resonance (CMR) may help predict outcome and guide redo procedures. We assessed the relationship between scar on CMR and PV reconnection after catheter ablation for paroxysmal AF. METHODS AND RESULTS: Fifty-one patients with paroxysmal AF underwent CMR before PVI using either a conventional single-electrode catheter (N = 28) or a circular multielectrode catheter (N = 23). At 3 months, a second CMR study was performed, followed by a systematic electrophysiological procedure to look for PV reconnection, regardless of AF recurrence. Preablation fibrosis and postablation scar were quantified and mapped from late gadolinium-enhanced CMR. CMR results were compared to the distribution and extent of PV reconnection. CMR and electrophysiological findings were compared between catheter types. Three months after successful PVI, scar gaps were found in 39 (76%) patients, and 78 (39%) veins. Electrical PV reconnection was detected in 45 (88%) patients, and 99 (50%) veins. The extent of PV reconnection related closely to the number of gaps (R = 0.55; P < .001), and to scar burden (R = -0.63; P < .001). However, the agreement was only fair for the localization of PV reconnection (k = 0.37; P < .001), scar gaps particularly lacking sensitivity in areas of pre-existing fibrosis. The circular catheter was associated with shorter procedures (P < .001), more scar (P = .01), less gaps (P = .01), and less reconnected veins (P = .03). CONCLUSION: PV reconnection is extremely frequent after PVI. CMR scar imaging accurately predicts its extent, but poorly predicts its location. Multielectrode circular catheters induce more complete ablation.


Assuntos
Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
Europace ; 21(Supplement_1): i27-i33, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30801128

RESUMO

Successful mapping and ablation of ventricular tachycardias remains a challenging clinical task. Whereas conventional entrainment and activation mapping was for many years the gold standard to identify reentrant circuits in ischaemic ventricular tachycardia ablation procedures, substrate mapping has become the cornerstone of ventricular tachycardia ablation. In the last decade, technology has dramatically improved. In parallel to high-density automated mapping, cardiac imaging and image integration tools are increasingly used to assess the structural ventricular tachycardia substrate. The aim of this review is to describe the technologies underlying these new mapping systems and to discuss their possible role in providing new insights into identification and visualization of reentrant tachycardia mechanisms.


Assuntos
Técnicas de Imagem Cardíaca , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/anatomia & histologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Humanos
16.
Heart Rhythm ; 16(4): 553-561, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30389441

RESUMO

BACKGROUND: Ablation of complex atrial tachycardias (ATs) is difficult. OBJECTIVE: The purpose of this study was to elucidate a mechanism underlying the behavior of ATs during ablation and to create an algorithm to predict it. METHODS: An algorithm predicting termination/conversion of AT and the second AT circuit associated with the ablation site was developed from 52 index reentrant AT high-resolution activation maps in 45 patients (retrospective phase). First, the wavefront collision site was identified. Then, the N or N-1 beat was defined for each collision associated with the ablation site. When the AT involved wavefront collision solely between N-1/N-1 (N/N) beats, the AT would terminate during ablation. Conversely, when the AT included wavefront collision between N/N-1 beats, the index AT would convert to a second AT. The algorithm was then prospectively tested in 172 patients with 194 ATs (127 anatomic macroreentrant ATs [AMATs], 44 non-AMATs, 23 multiple-loop ATs). RESULTS: Accuracy in predicting AT termination/conversion and the second AT circuit was 95.9% overall, 96.1% in AMATs, 95.5% in non-AMATs, and 95.7% in multiple-loop ATs. Median (25th-75th percentile) absolute variation between predicted and actually observed cycle length of the second AT was 6 (4-9) ms. Prediction failure occurred in 8 ATs; either the second AT used an unmapped chamber or structure in the index map (n = 7) or a line of block was misinterpreted as very slow conduction in the index map (n = 1). CONCLUSION: A simple mechanism underlies the behavior of ATs during ablation, even in complex ATs. With a simple algorithm using high-resolution mapping, AT termination/conversion and the second AT circuit and cycle length may be predicted from the index activation map.


Assuntos
Ablação por Cateter , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/classificação
17.
J Cardiovasc Electrophysiol ; 30(2): 195-204, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30288836

RESUMO

BACKGROUND: The relationship between the local electrograms (EGMs) and wall thickness (WT) heterogeneity within infarct scars has not been thoroughly described. The relationship between WT and voltages and substrates for ventricular tachycardia (VT) was examined. METHODS: In 12 consecutive patients with myocardial infarction and VT, WT, defined by a multidetector computed tomography, and voltage were compared. In multicomponent EGMs, amplitudes of both far- and near-field components were manually measured, and the performance of the three-dimensional-mapping system automatic voltage measurement was assessed. RESULTS: Of 15 748 points acquired, 2677 points within 5 mm of the endocardial surface were analyzed. In total, 909 (34.0%) multicomponent EGMs were identified; 785 (86.4%) and 883 (97.1%) were distributed in the WT less than 4 and 5 mm, respectively. Far-field EGM voltages increased linearly from 0.14 mV (0.08-0.28 mV) in the WT: 0 to 1 mm to 0.70 mV (0.43-2.62 mV) in the WT: 4 to 5 mm (ρ = 0.430; P < 0.001), and a significant difference was demonstrated between any two WT-groups (P ≤ 0.001). In contrast, near-field EGM voltages varied from 0.27 mV (0.11-0.44 mV) in the WT: 0 to 1 mm to 0.29 mV (0.17-0.53 mV) in the WT: 4 to 5 mm with a poorer correlation (ρ = 0.062, P = 0.04). The proportion of points where the system automatically measured the voltage on near-field EGMs increased from less than 10% in areas of WT: 4 to 5 mm to 50% in areas less than 2 mm. Of 21 VTs observed, seven hemodynamically stable VTs were mapped and terminated in WT: 1 to 4 mm area. CONCLUSIONS: Although far-field voltages gradually increase with the WT, near-field does not. The three-dimensional-mapping system preferentially annotates the near-field components in thinner areas (center of the scar) and the far-field component in thicker areas when building a voltage map. Critical sites of VT are distributed in WT: 1 to 4 mm areas.


Assuntos
Potenciais de Ação , Cicatriz/diagnóstico por imagem , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Infarto do Miocárdio/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Cicatriz/complicações , Cicatriz/fisiopatologia , Feminino , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia
18.
Europace ; 20(suppl_3): iii94-iii101, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30476056

RESUMO

AIMS: Clinical application of patient-specific cardiac computer models requires fast and robust processing pipelines that can be seamlessly integrated into clinical workflows. We aim at building such a pipeline from computed tomography (CT) images to personalized cardiac electrophysiology (EP) model. The simulation output could be useful in the context of post-infarct ventricular tachycardia (VT) radiofrequency ablation (RFA) planning for pre-operative targets prediction. METHODS AND RESULTS: The support for model personalization is a patient-specific virtual three-dimensional heart obtained from CT images. Here, the scar is identified as thinning of the myocardial wall on automatically computed thickness maps. We then use an Eikonal model of wave front propagation with reduced velocity in the damaged areas. An image-based vessel enhancement algorithm can automatically identify VT isthmuses. The personalized model is used for virtual pacing. We obtained a very fast pipeline that enables simulations in only a few minutes. It is fully automated starting from the semi-automated image segmentation phase. The computational time frame is compatible with the construction of a virtual pacing tool. In this tool, onset points and an optional directional block could be interactively selected. The directional block is a simple way to model tissue refractoriness. Output activation maps are compared with EP data acquired pre-operatively. We show that this framework allows the reproduction of recorded re-entrant VT activation patterns. CONCLUSION: Our simulation framework has an application in VT RFA intervention planning. It could be used to guide EP explorations and even predict ablation targets pre-operatively. This could reduce intervention duration and improve success rate.


Assuntos
Ablação por Cateter , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Modelos Cardiovasculares , Tomografia Computadorizada Multidetectores , Modelagem Computacional Específica para o Paciente , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Tomada de Decisão Clínica , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Seleção de Pacientes , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Fluxo de Trabalho
20.
Circ Arrhythm Electrophysiol ; 11(7): e006120, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30002064

RESUMO

BACKGROUND: Sudden cardiac death because of ventricular fibrillation (VF) is commonly unexplained in younger victims. Detailed electrophysiological mapping in such patients has not been reported. METHODS: We evaluated 24 patients (29±13 years) who survived idiopathic VF. First, we used multielectrode body surface recordings to identify the drivers maintaining VF. Then, we analyzed electrograms in the driver regions using endocardial and epicardial catheter mapping during sinus rhythm. Established electrogram criteria were used to identify the presence of structural alterations. RESULTS: VF occurred spontaneously in 3 patients and was induced in 16, whereas VF was noninducible in 5. VF mapping demonstrated reentrant and focal activities (87% versus 13%, respectively) in all. The activities were dominant in one ventricle in 9 patients, whereas they had biventricular distribution in others. During sinus rhythm areas of abnormal electrograms were identified in 15/24 patients (62.5%) revealing localized structural alterations: in the right ventricle in 11, the left ventricle in 1, and both in 3. They covered a limited surface (13±6 cm2) representing 5±3% of the total surface and were recorded predominantly on the epicardium. Seventy-six percent of these areas were colocated with VF drivers (P<0.001). In the 9 patients without structural alteration, we observed a high incidence of Purkinje triggers (7/9 versus 4/15, P=0.033). Catheter ablation resulted in arrhythmia-free outcome in 15/18 patients at 17±11 months follow-up. CONCLUSIONS: This study shows that localized structural alterations underlie a significant subset of previously unexplained sudden cardiac death. In the other subset, Purkinje electrical pathology seems as a dominant mechanism.


Assuntos
Potenciais de Ação , Morte Súbita Cardíaca/etiologia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Ramos Subendocárdicos/fisiopatologia , Fibrilação Ventricular/diagnóstico , Adolescente , Adulto , Estimulação Cardíaca Artificial , Ablação por Cateter , Causas de Morte , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Intervalo Livre de Progressão , Ramos Subendocárdicos/cirurgia , Fatores de Risco , Fatores de Tempo , Fibrilação Ventricular/complicações , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/prevenção & controle , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA