Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Biomed Mater Res B Appl Biomater ; 105(4): 707-714, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-26687460

RESUMO

Repair of degenerated intervertebral discs (IVD) might be established via intradiscal delivery of biologic therapies. Polyester amide polymers (PEA) were evaluated for in vitro cytotoxicity and in vivo biocompatibility, and thereafter intradiscal application of PEA microspheres (PEAMs) in a canine model predisposed to IVD degeneration at long-term (6 months) follow-up. PEA extracts did not induce cytotoxicity in mouse fibroblast cells (microscopy and XTT assay), while a slight foreign body reaction was demonstrated by histopathology after intramuscular implantation in rabbits. Intradiscal injection of a volume of 40 µL through 26 and 27G needles induced no degenerative changes in acanine model susceptible to IVD disease. Although sham-injected IVDs showed increased CAV1 expression compared with noninjected IVDs, which may indicate increased cell senescence, these findings were not supported by immunohistochemistry, biomolecular analysis of genes related to apoptosis, biochemical and histopathological results. PEAM-injected IVDs showed significantly higher BAX/BCL2 ratio vs sham-injected IVDs suggestive of an anti-apoptotic effect of the PEAMs. These findings were not supported by other analyses (clinical signs, disc height index, T2 values, biomolecular and biochemical analyses, and IVD histopathology). PEAs showed a good cytocompatibility and biocompatibility. PEAMs are considered safe sustained release systems for intradiscal delivery of biological treatments. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 707-714, 2017.


Assuntos
Degeneração do Disco Intervertebral/terapia , Teste de Materiais , Microesferas , Poliésteres/farmacologia , Animais , Apoptose/efeitos dos fármacos , Modelos Animais de Doenças , Cães , Avaliação Pré-Clínica de Medicamentos , Regulação da Expressão Gênica/efeitos dos fármacos , Degeneração do Disco Intervertebral/metabolismo , Degeneração do Disco Intervertebral/patologia , Camundongos , Poliésteres/efeitos adversos , Coelhos , Proteína X Associada a bcl-2/biossíntese
2.
J Control Release ; 130(1): 15-21, 2008 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-18554743

RESUMO

The purpose of this study was to develop and validate a screening method based on scintillation probes for the simultaneous evaluation of in vivo growth factor release profiles of multiple implants in the same animal. First, we characterized the scintillation probes in a series of in vitro experiments to optimize the accuracy of the measurement setup. The scintillation probes were found to have a strong geometric dependence and experience saturation effects at high activities. In vitro simulation of 4 subcutaneous limb implants in a rat showed minimal interference of surrounding implants on local measurements at close to parallel positioning of the probes. These characteristics were taken into consideration for the design of the probe setup and in vivo experiment. The measurement setup was then validated in a rat subcutaneous implantation model using 4 different sustained release carriers loaded with (125)I-BMP-2 per animal. The implants were removed after 42 or 84 days of implantation, for comparison of the non-invasive method to ex vivo radioisotope counting. The non-invasive method demonstrated a good correlation with the ex vivo counting method at both time-points of all 4 carriers. Overall, this study showed that scintillation probes could be successfully used for paired measurement of 4 release profiles with minimal interference of the surrounding implants, and may find use as non-invasive screening tools for various drug delivery applications.


Assuntos
Implantes Absorvíveis , Proteínas Morfogenéticas Ósseas , Sistemas de Liberação de Medicamentos/métodos , Fêmur , Fator de Crescimento Transformador beta , Animais , Materiais Biocompatíveis/química , Proteína Morfogenética Óssea 2 , Proteínas Morfogenéticas Ósseas/química , Proteínas Morfogenéticas Ósseas/farmacocinética , Proteínas Morfogenéticas Ósseas/farmacologia , Preparações de Ação Retardada , Avaliação Pré-Clínica de Medicamentos/instrumentação , Avaliação Pré-Clínica de Medicamentos/métodos , Fêmur/efeitos dos fármacos , Fêmur/metabolismo , Câmaras gama , Humanos , Radioisótopos do Iodo , Masculino , Ratos , Ratos Endogâmicos , Proteínas Recombinantes/química , Proteínas Recombinantes/farmacocinética , Proteínas Recombinantes/farmacologia , Distribuição Tecidual , Fator de Crescimento Transformador beta/química , Fator de Crescimento Transformador beta/farmacocinética , Fator de Crescimento Transformador beta/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA