Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Métodos Terapêuticos e Terapias MTCI
Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Refract Surg ; 34(12): 799-808, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30540362

RESUMO

PURPOSE: To report the outcomes of laser in situ keratomileusis (LASIK) for hyperopia using the Triple-A ablation profile with the MEL 90 excimer laser (Carl Zeiss Meditec, Jena, Germany). METHODS: This retrospective analysis included 1,383 eyes treated by LASIK for hyperopia using the Triple-A ablation profile with the MEL 90 at London Vision Clinic, London, United Kingdom, between September 2013 and December 2016. Inclusion criteria were attempted hyperopic correction of +0.25 diopters (D) or higher and corrected distance visual acuity (CDVA) of 20/40 or better. Patients were observed for 1 year after surgery. Standard outcomes analysis was performed. RESULTS: One-year data were available for 1,350 (97%) eyes. Mean attempted spherical equivalent refraction (SEQ) was +2.77 ± 1.34 D (range: +0.13 to +6.50 D) and mean cylinder was -0.67 ± 0.66 D (range: 0.00 to -5.00 D). Mean age was 54 ± 11 years (range: 21 to 75 years), and 57% were female. Postoperative spherical equivalent was ±0.50 D in 73% and ±1.00 D in 93% of eyes. Uncorrected distance visual acuity was 20/20 or better in 75% of eyes, relative to 93% with preoperative CDVA of 20/20 or better. One line of CDVA was lost in 17% of eyes and two lines were lost in 0.6% of eyes. There was a clinically insignificant but statistically significant increase (P < .01) in contrast sensitivity at 3 and 6 cycles per degree (cpd) and no change for 12 and 18 cpd. CONCLUSIONS: LASIK for hyperopia with the MEL 90 excimer laser was found to satisfy accepted criteria for safety, efficacy, and stability. [J Refract Surg. 2018;34(12):799-808.].


Assuntos
Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Adulto , Idoso , Córnea/fisiopatologia , Feminino , Humanos , Hiperopia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
2.
J Refract Surg ; 34(10): 672-680, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30296328

RESUMO

PURPOSE: To report the outcomes of LASIK for mixed cylinder using the Triple-A ablation profile with the MEL 90 excimer laser (Carl Zeiss Meditec, Jena, Germany). METHODS: This was a retrospective analysis of all eyes treated by LASIK for mixed cylinder using the Triple-A ablation profile with the MEL 90 laser between July 2013 and October 2016. Patients were observed for 1 year after surgery. Standard outcomes analysis and vector analysis by the Alpins method were performed. RESULTS: The database review identified 105 eyes (82 patients) treated by LASIK for mixed cylinder using the MEL 90 laser. Mean age was 40 ± 11 years (range: 18 to 65 years). Mean attempted spherical equivalent was +0.30 ± 0.90 diopters (D) (range: -2.30 to +1.75 D). Mean cylinder was -2.93 ± 1.47 D (range: -0.75 to -7.00 D). Preoperative corrected distance visual acuity (CDVA) was 20/20 or better in 81% of eyes. Postoperative uncorrected distance visual acuity was 20/20 or better in 69% and 20/25 or better in 86% of eyes. Mean postoperative spherical equivalent relative to the intended target was -0.21 ± 0.38 D (range: -1.25 to +1.13 D), with 83% within ±0.50 D. Mean postoperative cylinder was -0.57 ± 0.41 D (range: 0.00 to -1.75 D). Geometric mean was 1.12 for the correction index and 0.25 for the index of success. For angle of error, the arithmetic mean was -0.6° ± 4.2° (range: -13.5° to 9.5°) and the absolute mean was 2.9° ± 3.0° (range: 0.0° to 13.5°). There was loss of one line of CDVA in 3% of eyes and no eyes lost two or more lines CDVA. There was a small increase in contrast sensitivity after surgery at 3, 6, 12, and 18 cycles per degree (P < .05). CONCLUSIONS: One-year outcomes of LASIK using the MEL 90 laser for mixed cylinder up to -7.00 D demonstrated excellent efficacy, safety, and predictability. Vector analysis found a 12% overcorrection in magnitude of refractive cylinder. Given the high accuracy for angle of error, a nomogram could be applied to reduce the over-correction and further improve the uncorrected distance visual acuity outcomes. [J Refract Surg. 2018;34(10):672-680.].


Assuntos
Astigmatismo/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Adolescente , Adulto , Idoso , Astigmatismo/fisiopatologia , Sensibilidades de Contraste/fisiologia , Topografia da Córnea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Refração Ocular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA