Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Crit Care Med ; 47(8): 1050-1057, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31135498

RESUMO

OBJECTIVES: Accurate and timely identification of existing audible medical alarms is not adequate in clinical settings. New alarms that are easily heard, quickly identifiable, and discernable from one another are indicated. The "auditory icons" (brief sounds that serve as metaphors for the events they represent) have been proposed as a replacement to the current international standard. The objective was to identify the best performing icons based on audibility and performance in a simulated clinical environment. DESIGN: Three sets of icon alarms were designed using empirical methods. Subjects participated in a series of clinical simulation experiments that examined the audibility, identification accuracy, and response time of each of these icon alarms. A statistical model that combined the outcomes was used to rank the alarms in overall efficacy. We constructed the "best" and "worst" performing sets based on this ranking and prospectively validated these sets in a subsequent experiment with a new subject sample. SETTING: Experiments were conducted in simulated ICU settings at the University of Miami. SUBJECTS: Medical trainees were recruited from a convenience sample of nursing students and anesthesia residents at the institution. INTERVENTIONS: In Experiment 1 (formative testing), subjects were exposed to one of the three sets of alarms; identical setting and instruments were used throughout. In Experiment 2 (summative testing), subjects were exposed to one of the two sets of alarms, assembled from the best and worst performing alarms from Experiment 1. MEASUREMENTS AND MAIN RESULTS: For each alarm, we determined the minimum sound level to reach audibility threshold in the presence of background clinical noise, identification accuracy (percentage), and response time (seconds). We enrolled 123 medical trainees and professionals for participation (78 with < 6 yr of training). We identified the best performing icon alarms for each category, which matched or exceeded the other candidate alarms in identification accuracy and response time. CONCLUSIONS: We propose a set of eight auditory icon alarms that were selected through formative testing and validated through summative testing for adoption by relevant regulatory bodies and medical device manufacturers.


Assuntos
Percepção Auditiva , Alarmes Clínicos/normas , Monitorização Fisiológica/instrumentação , Som , Estimulação Acústica/métodos , Desenho de Equipamento/métodos , Falha de Equipamento , Humanos , Segurança do Paciente/normas
3.
Anesthesiology ; 129(1): 58-66, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29698253

RESUMO

BACKGROUND: Current standard audible medical alarms are difficult to learn and distinguish from one another. Auditory icons represent a new type of alarm that has been shown to be easier to learn and identify in laboratory settings by lay subjects. In this study, we test the hypothesis that icon alarms are easier to learn and identify than standard alarms by anesthesia providers in a simulated clinical setting. METHODS: Twenty anesthesia providers were assigned to standard or icon groups. Experiments were conducted in a simulated intensive care unit. After a brief group-specific alarm orientation, subjects identified patient-associated alarm sounds during the simulation and logged responses via a tablet computer. Each subject participated in the simulation twice and was exposed to 32 alarm annunciations. Primary outcome measures were response accuracy and response times. Secondary outcomes included assessments of perceived fatigue and task load. RESULTS: Overall accuracy rate in the standard alarm group was 43% (mean) and in the icon group was 88% (mean). Subjects in the icon group were 26.1 (odds ratio [98.75% CI, 8.4 to 81.5; P < 0.001]) times more likely to correctly identify an alarm. Response times in the icon group were shorter than in the standard alarm group (12 vs. 15 s, difference 3 s [98.75% CI ,1 to 5; P < 0.001]). CONCLUSIONS: Under our simulated conditions, anesthesia providers more correctly and quickly identified icon alarms than standard alarms. Subjects were more likely to perceive higher fatigue and task load when using current standard alarms than icon alarms.


Assuntos
Estimulação Acústica/normas , Alarmes Clínicos/normas , Falha de Equipamento , Unidades de Terapia Intensiva/normas , Tempo de Reação , Estimulação Acústica/métodos , Humanos , Tempo de Reação/fisiologia , Inquéritos e Questionários
4.
Q J Exp Psychol (Hove) ; 62(1): 63-83, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18609397

RESUMO

Two experiments on the internal representation of auditory stimuli compared the pairwise and grouping methodologies as means of deriving similarity judgements. A total of 45 undergraduate students participated in each experiment, judging the similarity of short auditory stimuli, using one of the methodologies. The experiments support and extend Bonebright's (1996) findings, using a further 60 stimuli. Results from both methodologies highlight the importance of category information and acoustic features, such as root mean square (RMS) power and pitch, in similarity judgements. Results showed that the grouping task is a viable alternative to the pairwise task with N > 20 sounds whilst highlighting subtle differences, such as cluster tightness, between the different task results. The grouping task is more likely to yield category information as underlying similarity judgements.


Assuntos
Percepção Auditiva/fisiologia , Discriminação Psicológica/fisiologia , Julgamento/fisiologia , Estimulação Acústica/métodos , Análise por Conglomerados , Feminino , Humanos , Masculino , Psicoacústica , Tempo de Reação/fisiologia , Som
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA