Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Am Acad Dermatol ; 90(4): 767-774, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38086517

RESUMO

BACKGROUND: People with Neurofibromatosis Type 1 (NF1) suffer disfigurement and pain when hundreds to thousands of cutaneous neurofibromas (cNFs) appear and grow throughout life. Surgical removal of cNFs under anesthesia is the only standard therapy, leaving surgical scars. OBJECTIVE: Effective, minimally-invasive, safe, rapid, tolerable treatment(s) of small cNFs that may prevent tumor progression. METHODS: Safety, tolerability, and efficacy of 4 different treatments were compared in 309, 2-4 mm cNFs across 19 adults with Fitzpatrick skin types (FST) I-IV: radiofrequency (RF) needle coagulation, 755 nm alexandrite laser with suction, 980 nm diode laser, and intratumoral injection of 10 mg/mL deoxycholate. Regional pain, clinical responses, tumor height and volume (by 3D photography) were assessed before, 3 and 6 months post-treatment. Biopsies were obtained electively at 3 months. RESULTS: There was no scarring or adverse events > grade 2. Each modality significantly (P < .05) reduced or cleared cNFs, with large variation between tumors and participants. Alexandrite laser and deoxycholate were fast and least painful; 980 nm laser was most painful. Growth of cNFs was not stimulated by treatment(s) based on height and volume values at 3 and 6 months compared to baseline. LIMITATIONS: Intervention was a single treatment session; dosimetry has not been optimized. CONCLUSIONS: Small cNFs can be rapidly and safely treated without surgery.


Assuntos
Neurofibroma , Neurofibromatose 1 , Neuroma , Neoplasias Cutâneas , Adulto , Humanos , Estudos Prospectivos , Neurofibroma/cirurgia , Resultado do Tratamento , Neoplasias Cutâneas/cirurgia , Neurofibromatose 1/complicações , Neurofibromatose 1/terapia , Cicatriz , Dor , Ácido Desoxicólico
2.
PLoS One ; 18(8): e0290347, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37624860

RESUMO

Antimicrobial blue light (aBL) is an attractive option for managing biofilm burden at the skin-implant interface of percutaneous osseointegrated (OI) implants. However, marketed aBL devices have both structural and optical limitations that prevent them from being used in an OI implant environment. They must be handheld, preventing even irradiation of the entire skin-implant interface, and the devices do not offer sufficient optical power outputs required to kill biofilms. We present the developmental process of a unique aBL device that overcomes these limitations. Four prototypes are detailed, each being a progressive improvement from the previous iteration as we move from proof-of-concept to in vivo application. Design features focused on a cooling system, LED orientation, modularity, and "sheep-proofing". The final prototype was tested in an in vivo OI implant sheep model, demonstrating that it was structurally and optically adequate to address biofilm burdens at the skin-implant of percutaneous OI implants. The device made it possible to test aBL in the unique OI implant environment and compare its efficacy to clinical antibiotics-data which had not before been achievable. It has provided insight into whether or not continued pursual of light therapy research for OI implants, and other percutaneous devices, is worthwhile. However, the device has drawbacks concerning the cooling system, complexity, and size if it is to be translated to human clinical trials. Overall, we successfully developed a device to test aBL therapy for patients with OI implants and helped progress understanding in the field of infection management strategies.


Assuntos
Anti-Infecciosos , Prótese Ancorada no Osso , Humanos , Animais , Ovinos , Próteses e Implantes , Luz , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico
3.
J Photochem Photobiol B ; 244: 112720, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37186990

RESUMO

Cutaneous bacterial wound infections typically involve gram-positive cocci such as Staphylococcus aureus (SA) and usually become biofilm infections. Bacteria in biofilms may be 100-1000-fold more resistant to an antibiotic than the clinical laboratory minimal inhibitory concentration (MIC) for that antibiotic, contributing to antimicrobial resistance (AMR). AMR is a growing global threat to humanity. One pathogen-antibiotic resistant combination, methicillin-resistant SA (MRSA) caused more deaths globally than any other such combination in a recent worldwide statistical review. Many wound infections are accessible to light. Antimicrobial phototherapy, and particularly antimicrobial blue light therapy (aBL) is an innovative non-antibiotic approach often overlooked as a possible alternative or adjunctive therapy to reduce antibiotic use. We therefore focused on aBL treatment of biofilm infections, especially MRSA, focusing on in vitro and ex vivo porcine skin models of bacterial biofilm infections. Since aBL is microbicidal through the generation of reactive oxygen species (ROS), we hypothesized that menadione (Vitamin K3), a multifunctional ROS generator, might enhance aBL. Our studies suggest that menadione can synergize with aBL to increase both ROS and microbicidal effects, acting as a photosensitizer as well as an ROS recycler in the treatment of biofilm infections. Vitamin K3/menadione has been given orally and intravenously worldwide to thousands of patients. We conclude that menadione/Vitamin K3 can be used as an adjunct to antimicrobial blue light therapy, increasing the effectiveness of this modality in the treatment of biofilm infections, thereby presenting a potential alternative to antibiotic therapy, to which biofilm infections are so resistant.


Assuntos
Anti-Infecciosos , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Infecção dos Ferimentos , Humanos , Vitamina K 3/farmacologia , Vitamina K 3/uso terapêutico , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/uso terapêutico , Espécies Reativas de Oxigênio/farmacologia , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Anti-Infecciosos/farmacologia , Biofilmes , Infecções Estafilocócicas/tratamento farmacológico , Testes de Sensibilidade Microbiana
4.
Lasers Surg Med ; 55(4): 390-404, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36883985

RESUMO

BACKGROUND: Extracorporeal membrane oxygenators (ECMO) are currently utilized to mechanically ventilate blood when lung or lung and heart function are impaired, like in cases of acute respiratory distress syndrome (ARDS). ARDS can be caused by severe cases of carbon monoxide (CO) inhalation, which is the leading cause of poison-related deaths in the United States. ECMOs can be further optimized for severe CO inhalation using visible light to photo-dissociate CO from hemoglobin (Hb). In previous studies, we combined phototherapy with an ECMO to design a photo-ECMO device, which significantly increased CO elimination and improved survival in CO-poisoned animal models using light at 460, 523, and 620 nm wavelengths. Light at 620 nm was the most effective in removing CO. OBJECTIVE: The aim of this study is to analyze the light propagation at 460, 523, and 620 nm wavelengths and the 3D blood flow and heating distribution within the photo-ECMO device that increased CO elimination in CO-poisoned animal models. METHODS: Light propagation, blood flow dynamics, and heat diffusion were modeled using the Monte Carlo method and the laminar Navier-Stokes and heat diffusion equations, respectively. RESULTS: Light at 620 nm propagated through the device blood compartment (4 mm), while light at 460 and 523 nm only penetrated 48% to 50% (~2 mm). The blood flow velocity in the blood compartment varied with regions of high (5 mm/s) and low (1 mm/s) velocity, including stagnant flow. The blood temperatures at the device outlet for 460, 523, and 620 nm wavelengths were approximately 26.7°C, 27.4°C, and 20°C, respectively. However, the maximum temperatures within the blood treatment compartment rose to approximately 71°C, 77°C, and 21°C, respectively. CONCLUSIONS: As the extent of light propagation correlates with efficiency in photodissociation, the light at 620 nm is the optimal wavelength for removing CO from Hb while maintaining blood temperatures below thermal damage. Measuring the inlet and outlet blood temperatures is not enough to avoid unintentional thermal damage by light irradiation. Computational models can help eliminate risks of excessive heating and improve device development by analyzing design modifications that improve blood flow, like suppressing stagnant flow, further increasing the rate of CO elimination.


Assuntos
Intoxicação por Monóxido de Carbono , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Animais , Intoxicação por Monóxido de Carbono/terapia , Oxigenadores de Membrana , Oxigenação por Membrana Extracorpórea/métodos , Fototerapia/métodos , Síndrome do Desconforto Respiratório/terapia
5.
Lasers Surg Med ; 54(10): 1288-1297, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35593006

RESUMO

INTRODUCTION: The ability of ablative fractional lasers (AFL) to enhance topical drug uptake is well established. After AFL delivery, however, drug clearance by local vasculature is poorly understood. Modifications in vascular clearance may enhance AFL-assisted drug concentrations and prolong drug dwell time in the skin. Aiming to assess the role and modifiability of vascular clearance after AFL-assisted delivery, this study examined the impact of vasoregulative interventions on AFL-assisted 5-fluorouracil (5-FU) concentrations in in vivo skin. METHODS: 5-FU uptake was assessed in intact and AFL-exposed skin in a live pig model. After fractional CO2 laser exposure (15 mJ/microbeam, 5% density), vasoregulative intervention using topical brimonidine cream, epinephrine solution, or pulsed dye laser (PDL) was performed in designated treatment areas, followed by a single 5% 5-FU cream application. At 0, 1, 4, 48, and 72 h, 5-FU concentrations were measured in 500 and 1500 µm skin layers by mass spectrometry (n = 6). A supplemental assessment of blood flow following AFL ± vasoregulation was performed using optical coherence tomography (OCT) in a human volunteer. RESULTS: Compared to intact skin, AFL facilitated a prompt peak in 5-FU delivery that remained elevated up to 4 hours (1500 µm: 1.5 vs. 31.8 ng/ml [1 hour, p = 0.002]; 5.3 vs. 14.5 ng/ml [4 hours, p = 0.039]). However, AFL's impact was transient, with 5-FU concentrations comparable to intact skin at later time points. Overall, vasoregulative intervention with brimonidine or PDL led to significantly higher peak 5-FU concentrations, prolonging the drug's dwell time in the skin versus AFL delivery alone. As such, brimonidine and PDL led to twofold higher 5-FU concentrations than AFL alone in both skin layers by 1 hour (e.g., 500 µm: 107 ng/ml [brimonidine]; 96.9 ng/ml [PDL], 46.6 ng/ml [AFL alone], p ≤ 0.024), and remained significantly elevated at 4 hours (p ≤ 0.024). A similar pattern was observed for epinephrine, although trends remained nonsignificant (p ≥ 0.09). Prolonged 5-FU delivery was provided by PDL, resulting in sustained drug deposition compared to AFL alone at both 48 and 72 hours in the superficial skin layer (p ≤ 0.024). Supporting drug delivery findings, OCT revealed that increases in local blood flow after AFL were mitigated in test areas also exposed to PDL, brimonidine, or epinephrine, with PDL providing the greatest, sustained reduction in flow over 48 hours. CONCLUSION: Vasoregulative intervention in conjunction with AFL-assisted delivery enhances and prolongs 5-FU deposition in in vivo skin.


Assuntos
Lasers de Gás , Pele , Suínos , Humanos , Animais , Fluoruracila , Tartarato de Brimonidina/uso terapêutico , Epinefrina
6.
Lasers Surg Med ; 54(2): 256-267, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34350599

RESUMO

BACKGROUND AND OBJECTIVES: Carbon monoxide (CO) inhalation is the leading cause of poison-related deaths in the United States. CO binds to hemoglobin (Hb), displaces oxygen, and reduces oxygen delivery to tissues. The optimal treatment for CO poisoning in patients with normal lung function is the administration of hyperbaric oxygen (HBO). However, hyperbaric chambers are only available in medical centers with specialized equipment, resulting in delayed therapy. Visible light dissociates CO from Hb with minimal effect on oxygen binding. In a previous study, we combined a membrane oxygenator with phototherapy at 623 nm to produce a "mini" photo-ECMO (extracorporeal membrane oxygenation) device, which improved CO elimination and survival in CO-poisoned rats. The objective of this study was to develop a larger photo-ECMO device ("maxi" photo-ECMO) and to test its ability to remove CO from a porcine model of CO poisoning. STUDY DESIGN/MATERIALS AND METHODS: The "maxi" photo-ECMO device and the photo-ECMO system (six maxi photo-ECMO devices assembled in parallel), were tested in an in vitro circuit of CO poisoning. To assess the ability of the photo-ECMO device and the photo-ECMO system to remove CO from CO-poisoned blood in vitro, the half-life of COHb (COHb-t1/2 ), as well as the percent COHb reduction in a single blood pass through the device, were assessed. In the in vivo studies, we assessed the COHb-t1/2 in a CO-poisoned pig under three conditions: (1) While the pig breathed 100% oxygen through the endotracheal tube; (2) while the pig was connected to the photo-ECMO system with no light exposure; and (3) while the pig was connected to the photo-ECMO system, which was exposed to red light. RESULTS: The photo-ECMO device was able to fully oxygenate the blood after a single pass through the device. Compared to ventilation with 100% oxygen alone, illumination with red light together with 100% oxygen was twice as efficient in removing CO from blood. Changes in gas flow rates did not alter CO elimination in one pass through the device. Increases in irradiance up to 214 mW/cm2 were associated with an increased rate of CO elimination. The photo-ECMO device was effective over a range of blood flow rates and with higher blood flow rates, more CO was eliminated. A photo-ECMO system composed of six photo-ECMO devices removed CO faster from CO-poisoned blood than a single photo-ECMO device. In a CO-poisoned pig, the photo-ECMO system increased the rate of CO elimination without significantly increasing the animal's body temperature or causing hemodynamic instability. CONCLUSION: In this study, we developed a photo-ECMO system and demonstrated its ability to remove CO from CO-poisoned 45-kg pigs. Technical modifications of the photo-ECMO system, including the development of a compact, portable device, will permit treatment of patients with CO poisoning at the scene of their poisoning, during transit to a local emergency room, and in hospitals that lack HBO facilities.


Assuntos
Intoxicação por Monóxido de Carbono , Venenos , Animais , Monóxido de Carbono , Intoxicação por Monóxido de Carbono/terapia , Carboxihemoglobina/metabolismo , Humanos , Fototerapia/métodos , Ratos , Suínos
7.
Lasers Surg Med ; 54(3): 426-432, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34658052

RESUMO

BACKGROUND AND OBJECTIVES: Carbon monoxide (CO) poisoning is responsible for nearly 50,000 emergency department visits and 1200 deaths per year. Compared to oxygen, CO has a 250-fold higher affinity for hemoglobin (Hb), resulting in the displacement of oxygen from Hb and impaired oxygen delivery to tissues. Optimal treatment of CO-poisoned patients involves the administration of hyperbaric 100% oxygen to remove CO from Hb and to restore oxygen delivery. However, hyperbaric chambers are not widely available and this treatment requires transporting a CO-poisoned patient to a specialized center, which can result in delayed treatment. Visible light is known to dissociate CO from carboxyhemoglobin (COHb). In a previous study, we showed that a system composed of six photo-extracorporeal membrane oxygenation (ECMO) devices efficiently removes CO from a large animal with CO poisoning. In this study, we tested the hypothesis that the application of hyperbaric oxygen to the photo-ECMO device would further increase the rate of CO elimination. STUDY DESIGN/MATERIAL AND METHODS: We developed a hyperbaric photo-ECMO device and assessed the ability of the device to remove CO from CO-poisoned human blood. We combined four devices into a "hyperbaric photo-ECMO system" and compared its ability to remove CO to our previously described photo-ECMO system, which was composed of six devices ventilated with normobaric oxygen. RESULTS: Under normobaric conditions, an increase in oxygen concentration from 21% to 100% significantly increased CO elimination from CO-poisoned blood after a single pass through the device. Increased oxygen pressure within the photo-ECMO device was associated with higher exiting blood PO2 levels and increased CO elimination. The system of four hyperbaric photo-ECMO devices removed CO from 1 L of CO-poisoned blood as quickly as the original, normobaric photo-ECMO system composed of six devices. CONCLUSION: This study demonstrates the feasibility and efficacy of using a hyperbaric photo-ECMO system to increase the rate of CO elimination from CO-poisoned blood. This technology could provide a simple portable emergency device and facilitate immediate treatment of CO-poisoned patients at or near the site of injury.


Assuntos
Intoxicação por Monóxido de Carbono , Monóxido de Carbono , Animais , Intoxicação por Monóxido de Carbono/complicações , Intoxicação por Monóxido de Carbono/terapia , Carboxihemoglobina , Hemoglobinas , Humanos , Oxigênio , Fototerapia/métodos
8.
Sci Transl Med ; 11(513)2019 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-31597752

RESUMO

Inhaled carbon monoxide (CO) displaces oxygen from hemoglobin, reducing the capacity of blood to carry oxygen. Current treatments for CO-poisoned patients involve administration of 100% oxygen; however, when CO poisoning is associated with acute lung injury secondary to smoke inhalation, burns, or trauma, breathing 100% oxygen may be ineffective. Visible light dissociates CO from hemoglobin. We hypothesized that the exposure of blood to visible light while passing through a membrane oxygenator would increase the rate of CO elimination in vivo. We developed a membrane oxygenator with optimal characteristics to facilitate exposure of blood to visible light and tested the device in a rat model of CO poisoning, with or without concomitant lung injury. Compared to ventilation with 100% oxygen, the addition of extracorporeal removal of CO with phototherapy (ECCOR-P) doubled the rate of CO elimination in CO-poisoned rats with normal lungs. In CO-poisoned rats with acute lung injury, treatment with ECCOR-P increased the rate of CO removal by threefold compared to ventilation with 100% oxygen alone and was associated with improved survival. Further development and adaptation of this extracorporeal CO photo-removal device for clinical use may provide additional benefits for CO-poisoned patients, especially for those with concurrent acute lung injury.


Assuntos
Intoxicação por Monóxido de Carbono/terapia , Oxigenação por Membrana Extracorpórea/métodos , Fototerapia/métodos , Lesão Pulmonar Aguda/terapia , Animais , Monóxido de Carbono/metabolismo , Hemoglobinas/metabolismo , Masculino , Ratos
9.
Shock ; 47(6): 735-742, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27861257

RESUMO

BACKGROUND: Carbon monoxide (CO) poisoning is a common cause of poison-related mortality. CO binds to hemoglobin in the blood to form carboxyhemoglobin (COHb), impairing oxygen delivery to peripheral tissues. Current treatment of CO-poisoned patients involves oxygen administration to rapidly remove CO and restore oxygen delivery. Light dissociates CO from COHb with high efficiency. Exposure of murine lungs to visible laser-generated light improved the CO elimination rate in vivo. The aims of this study were to apply pulmonary phototherapy to a larger animal model of CO poisoning, to test novel approaches to light delivery, and to examine the effect of chemiluminescence-generated light on the CO elimination rate. METHODS: Anesthetized and mechanically ventilated rats were poisoned with CO and subsequently treated with air or oxygen combined with or without pulmonary phototherapy delivered directly to the lungs of animals at thoracotomy, via intrapleural optical fibers or generated by a chemiluminescent reaction. RESULTS: Direct pulmonary phototherapy dissociated CO from COHb reducing COHb half-life by 38%. Early treatment with phototherapy in critically CO poisoned rats improved lactate clearance. Light delivered to the lungs of rats via intrapleural optical fibers increased the rate of CO elimination without requiring a thoracotomy, as demonstrated by a 16% reduction in COHb half-life. Light generated in the pleural spaces by a chemiluminescent reaction increased the rate of CO elimination in rats breathing oxygen, reducing the COHb half-life by 12%. CONCLUSIONS: Successful application of pulmonary phototherapy in larger animals and humans may represent a significant advance in the treatment of CO-poisoned patients.


Assuntos
Intoxicação por Monóxido de Carbono/terapia , Fototerapia/métodos , Androstanóis/farmacologia , Animais , Pressão Sanguínea/efeitos dos fármacos , Temperatura Corporal , Monóxido de Carbono/toxicidade , Artérias Carótidas/efeitos dos fármacos , Modelos Animais de Doenças , Fentanila/farmacologia , Frequência Cardíaca/efeitos dos fármacos , Hemoglobinas/metabolismo , Injeções Intraperitoneais , Ketamina/farmacologia , Luminescência , Masculino , Ratos , Ratos Sprague-Dawley , Rocurônio , Traqueotomia
10.
Am J Respir Crit Care Med ; 192(10): 1191-9, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26214119

RESUMO

RATIONALE: Carbon monoxide (CO) exposure is a leading cause of poison-related mortality. CO binds to Hb, forming carboxyhemoglobin (COHb), and produces tissue damage. Treatment of CO poisoning requires rapid removal of CO and restoration of oxygen delivery. Visible light is known to effectively dissociate CO from Hb, with a single photon dissociating one CO molecule. OBJECTIVES: To determine whether illumination of the lungs of CO-poisoned mice causes dissociation of COHb from blood transiting the lungs, releasing CO into alveoli and thereby enhancing the rate of CO elimination. METHODS: We developed a model of CO poisoning in anesthetized and mechanically ventilated mice to assess the effects of direct lung illumination (phototherapy) on the CO elimination rate. Light at wavelengths between 532 and 690 nm was tested. The effect of lung phototherapy administered during CO poisoning was also studied. To avoid a thoracotomy, we assessed the effect of lung phototherapy delivered to murine lungs via an optical fiber placed in the esophagus. MEASUREMENTS AND MAIN RESULTS: In CO-poisoned mice, phototherapy of exposed lungs at 532, 570, 592, and 628 nm dissociated CO from Hb and doubled the CO elimination rate. Phototherapy administered during severe CO poisoning limited the blood COHb increase and improved the survival rate. Noninvasive transesophageal phototherapy delivered to murine lungs via an optical fiber increased the rate of CO elimination while avoiding a thoracotomy. CONCLUSIONS: Future development and scaling up of lung phototherapy for patients with CO exposure may provide a significant advance for treating and preventing CO poisoning.


Assuntos
Intoxicação por Monóxido de Carbono/terapia , Carboxihemoglobina/metabolismo , Fototerapia/métodos , Animais , Intoxicação por Monóxido de Carbono/sangue , Carboxihemoglobina/análise , Modelos Animais de Doenças , Taxa de Depuração Metabólica/fisiologia , Camundongos
11.
Lasers Surg Med ; 47(1): 17-29, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25418831

RESUMO

BACKGROUND AND OBJECTIVES: We have developed a light-activated technology for rapidly sealing skin surgical wounds called photochemical tissue bonding (PTB). The goals of this study were to evaluate parameters influencing PTB in order to optimize its clinical efficacy and to determine whether PTB can be used to seal wounds in moderately to highly pigmented skin. STUDY DESIGN/MATERIALS AND METHODS: Application of Rose Bengal (RB) followed by exposure to 532 nm was used to seal linear incisions (1.5 mm deep, 2 cm long) in lightly pigmented (Yorkshire) and darkly pigmented (Yucatan) swine skin. The force required to open the seal (the bonding strength) was measured by in situ tensiometry. Reflectance spectra, epidermal transmission spectra, and histology were used to characterize the skin. The relationships of RB concentration and fluence to bonding strength were established in Yorkshire skin. Surface temperature was measured during irradiations and cooling was used while sealing incisions in Yucatan skin. Monte Carlo simulations were carried out to estimate the effect of epidermal melanin on the power absorbed in the dermis at the incision interface. RESULTS: The lowest fluence, 25 J/cm(2), delivered at an irradiance of 0.5 W/cm(2) substantially increased the bonding strength (∼ 10-fold) compared to controls in Yorkshire swine skin. Increasing the fluence to 100 J/cm(2) enhanced bonding strength by a further 1.5-fold. Application of 0.1% RB for 2 minutes produced the greatest bonding strength using 100 J/cm(2) and limited the penetration of RB to an ∼ 50 µm band on the dermal incision wall. Reflectance spectra indicated that Yorkshire skin had minimal melanin and that Yucatan skin was a good model for highly pigmented human skin. In Yucatan skin, the bonding strength increased 1.7-fold using 0.1% RB and 200 J/cm(2) at 1.5 W/cm(2) with cooling and epinephrine. Monte Carlo simulation indicated that absorption of 532 nm light by epidermal melanin in dark skin decreased the power absorbed along the incision in the dermis by a factor of 2.7. CONCLUSIONS: These results suggest that in lightly pigmented skin the PTB treatment time can be shortened without compromising the bonding strength. Sealing incisions using PTB in moderately and highly pigmented skin will require a careful balance of irradiance and cooling.


Assuntos
Lasers de Estado Sólido/uso terapêutico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Rosa Bengala/uso terapêutico , Pele/lesões , Técnicas de Fechamento de Ferimentos , Animais , Biomarcadores/metabolismo , Fenômenos Biomecânicos , Feminino , Masculino , Melaninas/metabolismo , Método de Monte Carlo , Pele/metabolismo , Pele/fisiopatologia , Lesões dos Tecidos Moles/tratamento farmacológico , Suínos , Cicatrização/fisiologia
12.
Lasers Surg Med ; 42(2): 113-22, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20166154

RESUMO

BACKGROUND AND OBJECTIVES: Ablative fractional resurfacing (AFR) creates vertical channels that might assist the delivery of topically applied drugs into skin. The purpose of this study was to evaluate drug delivery by CO(2) laser AFR using methyl 5-aminolevulinate (MAL), a porphyrin precursor, as a test drug. MATERIALS AND METHODS: Two Yorkshire swine were treated with single-hole CO(2) laser AFR and subsequent topical application of MAL (Metvix(R), Photocure ASA, Oslo, Norway), placebo cream and no drug. MAL-induced porphyrin fluorescence was measured by fluorescence microscopy at skin depths down to 1,800 microm. AFR was performed with a 10.6 microm wavelength prototype CO(2) laser, using stacked single pulses of 3 millisecond and 91.6 mJ per pulse. RESULTS: AFR created cone-shaped channels of approximately 300 microm diameter and 1,850 microm depth that were surrounded by a 70 microm thin layer of thermally coagulated dermis. There was no porphyrin fluorescence in placebo cream or untreated skin sites. AFR followed by MAL application enhanced drug delivery with significantly higher porphyrin fluorescence of hair follicles (P<0.0011) and dermis (P<0.0433) versus MAL alone at skin depths of 120, 500, 1,000, 1,500, and 1,800 microm. AFR before MAL application also enhanced skin surface (epidermal) porphyrin fluorescence. Radial diffusion of MAL from the laser-created channels into surrounding dermis was evidenced by uniform porphyrin fluorescence up to 1,500 microm from the holes (1,000, 1,800 microm depths). Skin massage after MAL application did not affect MAL-induced porphyrin fluorescence after AFR. CONCLUSIONS: Ablative fractional laser treatment facilitates delivery of topical MAL deeply into the skin. For the conditions of this study, laser channels approximately 3 mm apart followed by MAL application could produce porphyrins throughout essentially the entire skin. AFR appears to be a clinically practical means for enhancing uptake of MAL, a photodynamic therapy drug, and presumably many other topical skin medications.


Assuntos
Ácido Aminolevulínico/análogos & derivados , Terapia com Luz de Baixa Intensidade/métodos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Administração Cutânea , Ácido Aminolevulínico/farmacologia , Animais , Sistemas de Liberação de Medicamentos , Lasers de Gás/uso terapêutico , Masculino , Modelos Animais , Sensibilidade e Especificidade , Absorção Cutânea/efeitos dos fármacos , Absorção Cutânea/efeitos da radiação , Suínos
13.
Lasers Surg Med ; 38(10): 913-9, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17163478

RESUMO

BACKGROUND AND OBJECTIVES: In theory, infrared vibrational bands could be used for selective photothermolysis of lipid-rich tissues such as fat, sebaceous glands, or atherosclerotic plaques. STUDY DESIGN/MATERIALS AND METHODS: Absorption spectra of human fat were measured, identifying promising bands near 1,210 and 1,720 nm. Photothermal excitation of porcine fat and dermis were measured with a 3.5-5 microm thermal camera during exposure to the free electron laser (FEL) at Jefferson National Laboratory. Thermal damage to full-thickness samples exposed at approximately 1,210 nm through a cold contact window, was assessed by nitrobluetetrazolium chloride staining in situ and by light microscopy. RESULTS: Photothermal excitation of fat was twice that of dermis, at lipid absorption bands (1,210, 1,720 nm). At 1,210 nm, a subcutaneous fat layer several mm thick was damaged by FEL exposure, without apparent injury to overlying skin. CONCLUSION: Selective photothermal targeting of fatty tissues is feasible using infrared lipid absorption bands. Potential clinical applications are suggested by this FEL study.


Assuntos
Tecido Adiposo/efeitos da radiação , Derme/efeitos da radiação , Terapia a Laser , Fototerapia , Animais , Elétrons , Humanos , Fototerapia/efeitos adversos , Fototerapia/métodos , Suínos
14.
Lasers Surg Med ; 37(4): 264-70, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16196042

RESUMO

BACKGROUND AND OBJECTIVES: Photochemical tissue bonding (PTB) is a new non-thermal technique for tissue repair involving application of a photochemically active dye and irradiation with visible light. The objective was to compare PTB with standard sutures and the tissue adhesive, octyl cyanoacrylate, for closure of skin incisions and excisions. STUDY DESIGN/MATERIALS AND METHODS: Incisions and excisions made on the flanks of a Hanford mini-pig were secured with subcutaneous sutures. Superficial closure methods were 3-0 monofilament sutures, PTB (Rose Bengal and green light), tissue adhesive and the combination of tissue adhesive then PTB. Wounds were evaluated 2, 4, and 6 weeks postoperatively for cosmetic outcomes and histology. RESULTS: Cosmetic outcomes and histological scar width of incisions and excisions did not differ among the treatment groups at 2, 4, and 6 weeks. CONCLUSION: PTB is as effective as standard sutures for wound closure in porcine skin in terms of cosmetic outcomes and safety.


Assuntos
Procedimentos Cirúrgicos Dermatológicos , Corantes Fluorescentes/administração & dosagem , Terapia com Luz de Baixa Intensidade , Rosa Bengala/administração & dosagem , Suturas , Adesivos Teciduais , Animais , Estética , Masculino , Fotoquímica , Pele/patologia , Suínos , Porco Miniatura , Cicatrização
15.
Ann Otol Rhinol Laryngol ; 111(6): 486-92, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12090703

RESUMO

Treatment of recurrent respiratory papillomatosis of the glottis is often challenging. The surgeon and patient must cooperatively balance decisions regarding airway safety, effects of multiple general anesthesias, employment disturbance, and vocal dysfunction. A pilot study was done in 41 adult cases (23 patients; 78 vocal folds) without complication to evaluate the effectiveness of a 585-nm pulsed dye laser (PDL; 450-micros pulse width; fluence of 38 to 255 J/cm2; 1- to 2-mm spot size) in the treatment of this disorder. Thirty-seven of the 41 cases (90%) were bilateral disease. Twenty-six of the 41 cases (63%; including 20 cases with involvement of the anterior commissure) were treated by bilateral photocoagulation of the lesions' microcirculation without microflap resection of tissue. Clinical observation revealed that irradiated but unresected disease involuted without development of an anterior commissure web. In the initial 13 of the 41 cases (32%), PDL treatment was followed by cold instrument microflap resection. The PDL enhanced the epithelial excision by improving hemostasis and by creating an optimal dissection plane between the basement membrane and the underlying superficial lamina propria. The PDL at 585 nm was less effective in the management of exophytic lesions because of its limited depth of penetration (approximately 2 mm). In this initial trial, the PDL was a relatively safe and efficacious treatment for glottal recurrent respiratory papillomatosis. Since the lesions involute without complete resection of the diseased epithelium, the anterior commissure can be treated to minimize the number of procedures. To study patterns of recurrence will require longer follow-up.


Assuntos
Neoplasias Laríngeas/radioterapia , Terapia com Luz de Baixa Intensidade , Papiloma/radioterapia , Feminino , Glote , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA