Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 28(9): 3611-3620, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29633000

RESUMO

OBJECTIVES: To assess the inter-operator concordance and the potential sources of discordance in defining response to sorafenib in hepatocellular carcinoma (HCC). METHODS: All patients who received sorafenib between September 2008 and February 2015 were scrutinised for this retrospective study. Images were evaluated separately by three radiologists with different expertise in liver imaging (operator 1, >10 years; operator 2, 5 years; operator 3, no specific training in liver imaging), according to: response evaluation radiological criteria in solid tumours (RECIST) 1.1, modified RECIST (mRECIST) and response evaluation criteria in cancer of the liver (RECICL). RESULTS: The overall response concordance between the more expert operators was good, irrespective of the criteria (RECIST 1.1, ĸ = 0.840; mRECIST, ĸ = 0.871; RECICL, ĸ = 0.819). Concordance between the less expert operator and the other colleagues was lower. The most evident discordance was in target lesion response assessment, with expert operators disagreeing mostly on lesion selection and less expert operators on lesion measurement. As a clinical correlate, overall survival was more tightly related with "progressive disease" as assessed by the expert compared to the same assessment performed by operator 3. CONCLUSIONS: Decision on whether a patient is a responder or progressor under sorafenib may vary among different operators, especially in case of a non-specifically trained radiologist. Regardless of the adopted criteria, patients should be evaluated by experienced radiologists to minimise variability in this critical instance. KEY POINTS: • Inter-operator variability in the assessment of response to sorafenib is poorly known. • The concordance between operators with expertise in liver imaging was good. • Target lesions selection was the main source of discordance between expert operators. • Concordance with non-specifically trained operator was lower, independently from the response criteria. • The non-specifically trained operator was mainly discordant in measurements of target lesions.


Assuntos
Antineoplásicos/uso terapêutico , Carcinoma Hepatocelular/tratamento farmacológico , Neoplasias Hepáticas/tratamento farmacológico , Niacinamida/análogos & derivados , Compostos de Fenilureia/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/secundário , Competência Clínica , Erros de Diagnóstico , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Niacinamida/uso terapêutico , Variações Dependentes do Observador , Critérios de Avaliação de Resposta em Tumores Sólidos , Estudos Retrospectivos , Sorafenibe , Análise de Sobrevida , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
2.
PLoS One ; 10(6): e0127299, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26030804

RESUMO

This study evaluates changes in metabolite levels in hepatocellular carcinoma (HCC) cases vs. patients with liver cirrhosis by analysis of human blood plasma using gas chromatography coupled with mass spectrometry (GC-MS). Untargeted metabolomic analysis of plasma samples from participants recruited in Egypt was performed using two GC-MS platforms: a GC coupled to single quadruple mass spectrometer (GC-qMS) and a GC coupled to a time-of-flight mass spectrometer (GC-TOFMS). Analytes that showed statistically significant changes in ion intensities were selected using ANOVA models. These analytes and other candidates selected from related studies were further evaluated by targeted analysis in plasma samples from the same participants as in the untargeted metabolomic analysis. The targeted analysis was performed using the GC-qMS in selected ion monitoring (SIM) mode. The method confirmed significant changes in the levels of glutamic acid, citric acid, lactic acid, valine, isoleucine, leucine, alpha tocopherol, cholesterol, and sorbose in HCC cases vs. patients with liver cirrhosis. Specifically, our findings indicate up-regulation of metabolites involved in branched-chain amino acid (BCAA) metabolism. Although BCAAs are increasingly used as a treatment for cancer cachexia, others have shown that BCAA supplementation caused significant enhancement of tumor growth via activation of mTOR/AKT pathway, which is consistent with our results that BCAAs are up-regulated in HCC.


Assuntos
Biomarcadores Tumorais/sangue , Carcinoma Hepatocelular/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Neoplasias Hepáticas/sangue , Metabolômica/métodos , Carcinoma Hepatocelular/metabolismo , Egito , Feminino , Humanos , Neoplasias Hepáticas/metabolismo , Masculino , Pessoa de Meia-Idade
3.
J Proteome Res ; 11(12): 6231-41, 2012 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-23148940

RESUMO

Ozonated autohemotherapy (O3-AHT) is a medical approach during which blood obtained from the patient is ozonated and injected back into the body. Despite an increasing number of evidence that O3-AHT is safe, this type of therapy remains controversial. To extend knowledge about the changes in blood evoked by O3-AHT, LC-MS- and GC-MS-based metabolic fingerprinting was used to compare plasma samples obtained from blood before and after the treatment with potentially therapeutic concentrations of ozone. The procedure was performed in PVC bags utilized for blood storage to study also possible interactions between ozone and plastic. By use of GC-MS, an increase in lactic acid and pyruvic acid was observed, which indicated an increased rate of glycolysis. With LC-MS, changes in plasma antioxidants were observed. Moreover, concentrations of lipid oxidation products (LOP) and lysophospholipids were increased after ozone treatment. This is the first report of increased LOPs metabolites after ozonation of blood. Seven metabolites detected by LC-QTOF-MS only in ozonated samples could be considered as novel biomarkers of oxidative stress. Several plasticizers have been detected by both techniques in blood stored in PVC bags. PVC is known to be an ozone resistant material, but ozonation of blood in PVC bags stimulates leaching of plasticizers into the blood.


Assuntos
Cromatografia Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Metabolômica/métodos , Ozônio/sangue , Adulto , Antioxidantes/química , Biomarcadores/sangue , Contagem de Células Sanguíneas , Hemólise , Humanos , Ácido Láctico/sangue , Ácido Láctico/química , Lisofosfolipídeos/sangue , Masculino , Metaboloma , Oxirredução , Estresse Oxidativo , Ozônio/uso terapêutico , Plásticos/química , Cloreto de Polivinila/química , Ácido Pirúvico/sangue , Ácido Pirúvico/química , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA