RESUMO
AIMS: Excessive prolongation of PR interval impairs coupling of atrio-ventricular (AV) contraction, which reduces left ventricular pre-load and stroke volume, and worsens symptoms. His bundle pacing allows AV delay shortening while maintaining normal ventricular activation. HOPE-HF evaluated whether AV optimized His pacing is preferable to no-pacing, in a double-blind cross-over fashion, in patients with heart failure, left ventricular ejection fraction (LVEF) ≤40%, PR interval ≥200 ms and either QRS ≤140 ms or right bundle branch block. METHODS AND RESULTS: Patients had atrial and His bundle leads implanted (and an implantable cardioverter-defibrillator lead if clinically indicated) and were randomized to 6 months of pacing and 6 months of no-pacing utilizing a cross-over design. The primary outcome was peak oxygen uptake during symptom-limited exercise. Quality of life, LVEF and patients' holistic symptomatic preference between arms were secondary outcomes. Overall, 167 patients were randomized: 90% men, 69 ± 10 years, QRS duration 124 ± 26 ms, PR interval 249 ± 59 ms, LVEF 33 ± 9%. Neither peak oxygen uptake (+0.25 ml/kg/min, 95% confidence interval [CI] -0.23 to +0.73, p = 0.3) nor LVEF (+0.5%, 95% CI -0.7 to 1.6, p = 0.4) changed with pacing but Minnesota Living with Heart Failure quality of life improved significantly (-3.7, 95% CI -7.1 to -0.3, p = 0.03). Seventy-six percent of patients preferred His bundle pacing-on and 24% pacing-off (p < 0.0001). CONCLUSION: His bundle pacing did not increase peak oxygen uptake but, under double-blind conditions, significantly improved quality of life and was symptomatically preferred by the clear majority of patients. Ventricular pacing delivered via the His bundle did not adversely impact ventricular function during the 6 months.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Masculino , Humanos , Feminino , Fascículo Atrioventricular , Estudos Cross-Over , Volume Sistólico , Qualidade de Vida , Tolerância ao Exercício , Função Ventricular Esquerda , Oxigênio , Resultado do Tratamento , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodosRESUMO
OBJECTIVES: This study sought to test specialized processing of laser Doppler signals for discriminating ventricular fibrillation (VF) from common causes of inappropriate therapies. BACKGROUND: Inappropriate implantable cardioverter-defibrillator (ICD) therapies remain a clinically important problem associated with morbidity and mortality. Tissue perfusion biomarkers, implemented to assist automated diagnosis of VF, sometimes mistake artifacts and random noise for perfusion, which could lead to shocks being inappropriately withheld. METHODS: The study tested a novel processing algorithm that combines electrogram data and laser Doppler perfusion monitoring as a method for assessing circulatory status. Fifty patients undergoing VF induction during ICD implantation were recruited. Noninvasive laser Doppler and continuous electrograms were recorded during both sinus rhythm and VF. Two additional scenarios that might have led to inappropriate shocks were simulated for each patient: ventricular lead fracture and T-wave oversensing. The laser Doppler was analyzed using 3 methods for reducing noise: 1) running mean; 2) oscillatory height; and 3) a novel quantification of electromechanical coupling which gates laser Doppler relative to electrograms. In addition, the algorithm was tested during exercise-induced sinus tachycardia. RESULTS: Only the electromechanical coupling algorithm found a clear perfusion cut off between sinus rhythm and VF (sensitivity and specificity of 100%). Sensitivity and specificity remained at 100% during simulated lead fracture and electrogram oversensing. (Area under the curve running mean: 0.91; oscillatory height: 0.86; electromechanical coupling: 1.00). Sinus tachycardia did not cause false positive results. CONCLUSIONS: Quantifying the coupling between electrical and perfusion signals increases reliability of discrimination between VF and artifacts that ICDs may interpret as VF. Incorporating such methods into future ICDs may safely permit reductions of inappropriate shocks.
Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Eletrocardiografia , Falha de Equipamento , Fluxometria por Laser-Doppler , Processamento de Sinais Assistido por Computador , Fibrilação Ventricular/diagnóstico , Idoso , Algoritmos , Técnicas Eletrofisiológicas Cardíacas , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Taquicardia SinusalRESUMO
BACKGROUND: Conventional mapping techniques during atrial fibrillation (AF) are difficult to apply because of cycle length irregularity. Mapping studies are usually restricted to short durations of AF in limited regions because of the laborious manual annotation of local activation time (LAT). The purpose of this study was to test an automated algorithm to map activation during AF, with comparable accuracy to manual annotation. METHODS: Left atrial (LA) mapping was performed using a 20-pole double loop catheter (AFocusII) in 30-second data segments from 16 patients. The new algorithm (RETRO-Mapping) was designed to detect wavefront propagation between electrodes, and display activating wavefronts on a two-dimensional representation of the catheter. Activation patterns were validated against their bipolar electrograms and with isochronal maps. The mapping protocol was approved by the research ethics committee (13/LO1169 and 14/LO1367). RESULTS: During AF, uniform wavefront activation direction (mean ± SD, degrees) from manually constructed isochronal maps was comparable to RETRO-Propagation Map (RETRO-PM) and RETRO-Automated Direction (RETRO-AD): 1 ± 6.9 for RETRO-PM; and 2 ± 6.6 for RETRO-AD. There was no significant difference in activation direction assigned to 1373 uniform wavefronts during AF when comparing RETRO-PM with RETRO-AD (Bland-Altman mean difference: -0.1 degrees; limits of agreement: -8.0 to 8.3; 95% CI -0.4 to 0.2; (r = 0.01) R2 = < 0.005; P = .77). CONCLUSION: We have developed and validated a new technique to map activation during AF. This technique shows comparable accuracy to that of conventional isochronal mapping with careful manual adjustment of LAT.
Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/fisiopatologia , Processamento de Sinais Assistido por Computador , Potenciais de Ação , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Automação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de TempoRESUMO
AIMS: Ablation of persistent atrial fibrillation (PsAF) has been performed by many techniques with varying success rates. This may be due to ablation techniques, patient demographics, comorbidities, and trial design. We conducted a meta-regression of studies of PsAF ablation to elucidate the factors affecting atrial fibrillation (AF) recurrence. METHODS AND RESULTS: Databases were searched for prospective studies of PsAF ablation. A meta-regression was performed. Fifty-eight studies (6767 patients) were included. Complex fractionated atrial electrogram (CFAE) ablation reduced freedom from AF by 8.9% [95% confidence interval (CI) -15 to -2.3, P = 0.009). Left atrial appendage [LAA isolation (three study arms)] increased freedom from AF by 39.5% (95% CI 9.1-78.4, P = 0.008). Posterior wall isolation (PWI) (eight study arms) increased freedom from AF by 19.4% (95% CI 3.3-38.1, P = 0.017). Linear ablation or ganglionated plexi ablation resulted in no significant effect on freedom from AF. More extensive ablation increased intraprocedural AF termination; however, intraprocedural AF termination was not associated with improved outcomes. Increased left atrial diameter was associated with a reduction in freedom from AF by 4% (95% CI -6.8% to -1.1%, P = 0.007) for every 1 mm increase in diameter. CONCLUSION: Linear ablation, PWI, and CFAE ablation improves intraprocedural AF termination, but such termination does not predict better long-term outcomes. Study arms including PWI or LAA isolation in the lesion set were associated with improved outcomes in terms of freedom from AF; however, further randomized trials are required before these can be routinely recommended. Left atrial size is the most important marker of AF chronicity influencing outcomes.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Efeitos Adversos de Longa Duração/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Recidiva , Análise de Regressão , Medição de Risco/métodos , Resultado do TratamentoAssuntos
Ansiedade/psicologia , Determinação de Ponto Final , Cura pela Fé/psicologia , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Projetos de Pesquisa , Pesquisadores/psicologia , Sujeitos da Pesquisa/psicologia , Ansiedade/diagnóstico , Ansiedade/fisiopatologia , Viés , Causas de Morte , Progressão da Doença , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Humanos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Ripple Mapping (RM) is designed to overcome the limitations of existing isochronal 3D mapping systems by representing the intracardiac electrogram as a dynamic bar on a surface bipolar voltage map that changes in height according to the electrogram voltage-time relationship, relative to a fiduciary point. OBJECTIVE: We tested the hypothesis that standard approaches to atrial tachycardia CARTO™ activation maps were inadequate for RM creation and interpretation. From the results, we aimed to develop an algorithm to optimize RMs for future prospective testing on a clinical RM platform. METHODS: CARTO-XP™ activation maps from atrial tachycardia ablations were reviewed by two blinded assessors on an off-line RM workstation. Ripple Maps were graded according to a diagnostic confidence scale (Grade I - high confidence with clear pattern of activation through to Grade IV - non-diagnostic). The RM-based diagnoses were corroborated against the clinical diagnoses. RESULTS: 43 RMs from 14 patients were classified as Grade I (5 [11.5%]); Grade II (17 [39.5%]); Grade III (9 [21%]) and Grade IV (12 [28%]). Causes of low gradings/errors included the following: insufficient chamber point density; window-of-interest<100% of cycle length (CL); <95% tachycardia CL mapped; variability of CL and/or unstable fiducial reference marker; and suboptimal bar height and scar settings. CONCLUSIONS: A data collection and map interpretation algorithm has been developed to optimize Ripple Maps in atrial tachycardias. This algorithm requires prospective testing on a real-time clinical platform.
Assuntos
Algoritmos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Supraventricular/diagnóstico , Idoso , Ablação por Cateter/métodos , Cicatriz/cirurgia , Feminino , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Atrial Ectópica/patologia , Taquicardia Atrial Ectópica/fisiopatologia , Taquicardia Supraventricular/patologia , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgiaRESUMO
AIMS: Whether adjusting interventricular (VV) delay changes haemodynamic efficacy of cardiac resynchronization therapy (CRT) is controversial, with conflicting results. This study addresses whether the convention for keeping atrioventricular (AV) delay constant during VV optimization might explain these conflicts. METHOD AND RESULTS: Twenty-two patients in sinus rhythm with existing CRT underwent VV optimization using non-invasive systolic blood pressure. Interventricular optimization was performed with four methods for keeping the AV delay constant: (i) atrium and left ventricle delay kept constant, (ii) atrium and right ventricle delay kept constant, (iii) time to the first-activated ventricle kept constant, and (iv) time to the second-activated ventricle kept constant. In 11 patients this was performed with AV delay of 120 ms, and in 11 at AV optimum. At AV 120 ms, time to the first ventricular lead (left or right) was the overwhelming determinant of haemodynamics (13.75 mmHg at ±80 ms, P < 0.001) with no significant effect of time to second lead (0.47 mmHg, P = 0.50), P < 0.001 for difference. At AV optimum, time to first ventricular lead again had a larger effect (5.03 mmHg, P < 0.001) than time to second (2.92 mmHg, P = 0.001), P = 0.02 for difference. CONCLUSION: Time to first ventricular activation is the overwhelming determinant of circulatory function, regardless of whether this is the left or right ventricular lead. If this is kept constant, the effect of changing time to the second ventricle is small or nil, and is not beneficial. In practice, it may be advisable to leave VV delay at zero. Specifying how AV delay is kept fixed might make future VV delay research more enlightening.
Assuntos
Nó Atrioventricular/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Bloqueio Cardíaco/terapia , Insuficiência Cardíaca/terapia , Hemodinâmica , Potenciais de Ação , Pressão Sanguínea , Terapia de Ressincronização Cardíaca/efeitos adversos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Ripple mapping (RM) displays each electrogram at its 3-dimensional coordinate as a bar changing in length according to its voltage-time relationship with a fiduciary reference. We applied RM to left ventricular ischemic scar for evidence of slow-conducting channels that may act as ventricular tachycardia (VT) substrate. METHODS AND RESULTS: CARTO-3© (Biosense Webster Inc, Diamond Bar, CA) maps in patient undergoing VT ablation were analyzed on an offline MatLab RM system. Scar was assessed for sequential movement of ripple bars, during sinus rhythm or pacing, which were distinct from surrounding tissue and termed RM conduction channels (RMCC). Conduction velocity was measured within RMCCs and compared with the healthy myocardium (>1.5 mV). In 21 maps, 77 RMCCs were identified. Conduction velocity in RMCCs was slower when compared with normal left ventricular myocardium (median, 54 [interquartile range, 40-86] versus 150 [interquartile range, 120-160] cm/s; P<0.001). All 7 sites meeting conventional criteria for diastolic pathways coincided with an RMCC. Seven patients had ablation colocating to all identified RMCCs with no VT recurrence during follow-up (median, 480 [interquartile range, 438-841] days). Fourteen patients had ≥1 RMCC with no ablation lesions. Five had recurrence during follow-up (median, 466 [interquartile range, 395-694] days). One of the 2 patients with no RMCC locations ablated had VT recurrence at 605 days post procedure. RMCCs were sensitive (100%; negative predictive value, 100%) for VT recurrence but the specificity (43%; positive predictive value, 35.7%) may be limited by blind alleys channels. CONCLUSIONS: RM identifies slow conduction channels within ischemic scar and needs further prospective investigation to understand the role of RMCCs in determining the VT substrate.
Assuntos
Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Isquemia Miocárdica/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Potenciais de Ação , Idoso , Estimulação Cardíaca Artificial , Ablação por Cateter , Cicatriz/diagnóstico , Europa (Continente) , Feminino , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Miocárdio/patologia , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Echocardiographic optimization of pacemaker settings is the current standard of care for patients treated with cardiac resynchronization therapy. However, the process requires considerable time of expert staff. The BRAVO study is a non-inferiority trial comparing echocardiographic optimization of atrioventricular (AV) and interventricular (VV) delay with an alternative method using non-invasive blood pressure monitoring that can be automated to consume less staff resources. METHODS/DESIGN: BRAVO is a multi-centre, randomized, cross-over, non-inferiority trial of 400 patients with a previously implanted cardiac resynchronization device. Patients are randomly allocated to six months in each arm. In the echocardiographic arm, AV delay is optimized using the iterative method and VV delay by maximizing LVOT VTI. In the haemodynamic arm AV and VV delay are optimized using non-invasive blood pressure measured using finger photoplethysmography. At the end of each six month arm, patients undergo the primary outcome measure of objective exercise capacity, quantified as peak oxygen uptake (VO2) on a cardiopulmonary exercise test. Secondary outcome measures are echocardiographic measurement of left ventricular remodelling, quality of life score and N-terminal pro B-type Natriuretic Peptide (NT-pro BNP). The study is scheduled to complete recruitment in December 2013 and to complete follow up in December 2014. DISCUSSION: If exercise capacity is non-inferior with haemodynamic optimization compared with echocardiographic optimization, it would be proof of concept that haemodynamic optimization is an acceptable alternative which has the potential to be more easily implemented. TRIAL REGISTRATION: Clinicaltrials.gov NCT01258829.
Assuntos
Determinação da Pressão Arterial/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia Doppler , Insuficiência Cardíaca/terapia , Fotopletismografia , Projetos de Pesquisa , Biomarcadores/sangue , Protocolos Clínicos , Estudos Cross-Over , Teste de Esforço , Tolerância ao Exercício , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Valor Preditivo dos Testes , Qualidade de Vida , Recuperação de Função Fisiológica , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Função Ventricular Esquerda , Remodelação VentricularRESUMO
BACKGROUND: Three-dimensional (3D) mapping is often used to guide ablation in atrial tachycardia (AT), but maps can be susceptible to annotation and interpolation errors. Ripple Mapping (RM) is a technique that displays electrogram time-voltage data simultaneously as dynamic bars on the surface shell to overcome these limitations. OBJECTIVES: We hypothesized that RM would be superior to established 3D activation mapping. METHODS: CARTO-XP™ maps of ATs were collected without any manual annotation and studied on a CARTO-based offline RM system. Paired unannotated CARTO-XP and Ripple Maps were presented to experienced CARTO users with limited RM training. These assessors were allowed to annotate the CARTO-XP maps, but were blinded to conventional EP data. RESULTS: CARTO-XP maps of AT (10 patients) were studied in RM format and the diagnosis was confirmed by entrainment in all cases and with termination of tachycardia in 9/10 cases. Blinded assessors (n = 11) reached the correct diagnosis using RM in 35/44 (80%) compared to 22/44 (50%) using CARTO-XP (P = 0.029). The time to the correct diagnosis was also shorter with RM (136 seconds vs. 212 seconds; P = 0.022). The causes of diagnostic errors using RM (insufficient point density, particularly in low-voltage areas, and the operator not assessing all available views) were overcome with an improved MatLab version showing both scar and dynamic bars on the same shell. CONCLUSION: RM does not need any manual annotation of local activation time and enables rapid diagnosis of AT with higher diagnostic accuracy than conventional 3D activation mapping.
Assuntos
Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Imageamento Tridimensional , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/diagnóstico , Potenciais de Ação , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Erros de Diagnóstico/prevenção & controle , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Fatores de TempoRESUMO
BACKGROUND: Sites of high dominant frequency (DF(peak)) are thought to indicate the location of drivers of atrial fibrillation (AF), but characterization of their spatiotemporal distribution and stability, critical to their relevance as targets for catheter ablation, requires simultaneous global mapping of the left atrium. METHODS AND RESULTS: Noncontact electrograms recorded simultaneously from 256 left atrial sites during spontaneous AF were analyzed. After subtraction of the ventricular component, fast Fourier transform identified the DF at each site. Focal areas of DF(peak) were defined as those having a DF >20% above all neighboring sites. Twenty-four patients with spontaneous AF (11 paroxysmal and 13 persistent) were studied. In paroxysmal AF, sites of DF(peak) (mean DF, 11.6±2.9 Hz) were observed in 100% of patients (present during 65% of the mapping period). In contrast, DF(peak) was detected in only 31% of patients with persistent AF (P<0.001) and for only 5% of the mapping period (P<0.001). In both groups, locations of DF(peak) varied widely in both consecutive and separated segments of AF (κ coefficient range, -0.07-0.22). Activation sequences around sites of DF(peak) did not demonstrate centrifugal activation that would be expected from focal drivers. CONCLUSIONS: Focal areas of high DF are more frequent in paroxysmal than persistent AF, are spatiotemporally unstable, are not the source of centrifugal activation, and are not, therefore, indicative of fixed drivers of AF. In the absence of spatiotemporal stability, the success of ablation at sites of DF(peak) cannot be explained by elimination of fixed drivers.
Assuntos
Fibrilação Atrial/diagnóstico , Função Atrial , Técnicas Eletrofisiológicas Cardíacas , Análise de Fourier , Adulto , Idoso , Análise de Variância , Fibrilação Atrial/classificação , Fibrilação Atrial/fisiopatologia , Feminino , Átrios do Coração/fisiopatologia , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Análise de Regressão , Reprodutibilidade dos Testes , Fatores de TempoRESUMO
INTRODUCTION: The intrinsic cardiac autonomic nervous system (ANS) is implicated in atrial fibrillation (AF) but little is known about its role in maintenance of the electrophysiological substrate during AF in humans. We hypothesized that ANS activation by high-frequency stimulation (HFS) of ganglionated plexi (GP) increases dispersion of atrial AF cycle lengths (AFCLs) via a parasympathetic effect. METHODS AND RESULTS: During AF in 25 patients, HFS was delivered to presumed GP sites to provoke a bradycardic vagal response and AFCL was continuously monitored from catheters placed in the pulmonary vein (PV), coronary sinus (CS), and high right atrium (HRA). A total of 163 vagal responses were identified from 271 HFS episodes. With a vagal response, the greatest reduction in AFCL was seen in the PV adjacent to the site of HFS (16% reduction, 166 ± 28 to 139 ± 26 ms, P < 0.0001) followed by the PV-atrial junction (9% reduction, 173 ± 21 to 158 ± 20 ms, P < 0.0001), followed by the rest of the atrium (3-7% reduction recorded in HRA and CS). Without a vagal response, AFCL changes were not observed. In 10 patients, atropine was administered in between HFS episodes. Before atropine administration, HFS led to a vagal response and a reduction in PV AFCL (164 ± 28 to 147 ± 26 ms, P < 0.0001). Following atropine, HFS at the same GP sites no longer provoked a vagal response, and the PV AFCL remained unchanged (164 ± 30 to 166 ± 33 ms, P = 0.34). CONCLUSIONS: Activation of the parasympathetic component of the cardiac ANS may cause heterogenous changes in atrial AFCL that might promote PV drivers.