Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(5): 950-964, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38477184

RESUMO

INTRODUCTION: Peak frequency (PF) mapping is a novel method that may identify critical portions of myocardial substrate supporting reentry. The aim of this study was to describe and evaluate PF mapping combined with omnipolar voltage mapping in the identification of critical isthmuses of left atrial (LA) atypical flutters. METHODS AND RESULTS: LA omnipolar voltage and PF maps were generated in flutter using the Advisor HD-Grid catheter (Abbott) and EnSite Precision Mapping System (Abbott) in 12 patients. Normal voltage was defined as ≥0.5 mV, low-voltage as 0.1-0.5 mV, and scar as <0.1 mV. PF distributions were compared with ANOVA and post hoc Tukey analyses. The 1 cm radius from arrhythmia termination was compared to global myocardium with unpaired t-testing. The mean age was 65.8 ± 9.7 years and 50% of patients were female. Overall, 34 312 points were analyzed. Atypical flutters most frequently involved the mitral isthmus (58%) or anterior wall (25%). Mean PF varied significantly by myocardial voltage: normal (335.5 ± 115.0 Hz), low (274.6 ± 144.0 Hz), and scar (71.6 ± 140.5 Hz) (p < .0001 for all pairwise comparisons). All termination sites resided in low-voltage regions containing intermediate or high PF. Overall, mean voltage in the 1 cm radius from termination was significantly lower than the remaining myocardium (0.58 vs. 0.95 mV, p < .0001) and PF was significantly higher (326.4 vs. 245.1 Hz, p < .0001). CONCLUSION: Low-voltage, high-PF areas may be critical targets during catheter ablation of atypical atrial flutter.


Assuntos
Potenciais de Ação , Flutter Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Valor Preditivo dos Testes , Humanos , Flutter Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Frequência Cardíaca
2.
Europace ; 20(FI_3): f337-f342, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016785

RESUMO

Aims: To assess whether obstructive sleep apnea (OSA) was associated with increased rotor burden among atrial fibrillation (AF) patients. Methods and results: We studied 33 consecutive patients who were scheduled for focal impulse and rotor modulation (FIRM) ablation at our institution to describe the mapping, ablation, and outcomes, among patients with and without OSA. Patients underwent biatrial FIRM mapping in AF with ablation of stable rotors in addition to conventional ablation lesion sets. Differences between groups were tested with student's t-tests and Fisher's exact tests, as appropriate. Survival analyses were performed using the Kaplan-Meier method. Twelve of the 33 (36%) patients had OSA and 8 (66%) used continuous positive airway pressure ventilation (CPAP). Obstructive sleep apnea patients had a higher body mass index (BMI) (33.6 vs. 28.8 kg/m2, P = 0.01) and were more commonly on beta blockers (67% vs. 29%, P = 0.03) but were otherwise similar regarding baseline characteristics, medication use, and prior AF treatments, including antiarrhythmic drugs and prior ablation. Focal impulse and rotor modulation mapping demonstrated increased rotor burden in the OSA patients (2.6 ± 0.9 vs. 2.0 ± 1.0, P =0.03). The increased rotor burden was more evident in the right atrium (RA) (1.0 ± 0.7 vs. 0.5 ± 0.7, P =0.04 compared with left atrium (1.7 ± 0.8 vs. 1.4 ± 0.7, P = 0.15). There was no correlation between BMI and total number of rotors (r = 0.0961, P = 0.59). Among the population of patients with OSA, CPAP therapy was associated with a lower number of RA rotors (0.8 ± 0.7 vs. 1.5 ± 0.6, P = 0.05) but no significant difference in overall rotors (P = 0.33). Conclusion: Obstructive sleep apnea patients demonstrate increased rotor prevalence, driven predominantly by an increase in RA rotors. CPAP therapy was associated with fewer RA rotors.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Pressão Positiva Contínua nas Vias Aéreas , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Apneia Obstrutiva do Sono/terapia , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina/epidemiologia , Polissonografia , Prevalência , Recidiva , Estudos Retrospectivos , Fatores de Risco , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/fisiopatologia , Resultado do Tratamento
3.
J Interv Card Electrophysiol ; 47(1): 5-10, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26936264

RESUMO

The evolving healthcare environment demands optimally measured quality of care. Performance measures are increasingly being used for quality improvement, public reporting, and reimbursement determinations. The National Quality Forum has created rigorous criteria for the evaluation of potential performance measures across medical fields. The Heart Rhythm Society has championed the development of four separate electrophysiology (EP)-specific performance measures: implantable cardioverter defibrillator complication rate, cardiac tamponade and/or pericardiocentesis following atrial fibrillation ablation, infection within 180 days of a cardiac implantable electronic device implantation, replacement, or revision, and in-person evaluation following a cardiac implantable electronic device implantation. National registries serve a key role in developing performance measures and facilitating quality improvement, particularly as they provide improved granularity and accuracy of data compared with administrative claims data. All performance measures demand continued reassessment as technology and performance gaps change and as unintended consequences may arise.


Assuntos
Cardiologia/normas , Técnicas Eletrofisiológicas Cardíacas/normas , Política de Saúde/tendências , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Internacionalidade , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA