Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Microbiol Infect ; 29(9): 1198.e1-1198.e6, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37271195

RESUMO

OBJECTIVES: To analyse carbapenemases in Proteus mirabilis and assess the performance of carbapenemase detection assays. METHODS: Eighty-one clinical P. mirabilis isolates with high-level resistance at least to ampicillin (>32 mg/L) or previous detection of carbapenemases were selected and investigated by three susceptibility testing methods (microdilution, automated susceptibility testing, and disk diffusion), six phenotypic carbapenemase assays (CARBA NP, modified carbapenemase inactivation method [CIM], modified zinc-supplemented CIM, simplified CIM, faropenem, and carbapenem-containing agar), two immunochromatographic assays, and whole-genome sequencing. RESULTS: Carbapenemases were detected in 43 of 81 isolates (OXA-48-like [n = 13]; OXA-23 [n = 12]; OXA-58 [n = 12]; New Delhi metallo-ß-lactamase (NDM) [n = 2]; Verona integron-encoded metallo-ß-lactamase (VIM) [n = 2]; Imipenemase (IMP) [n = 1]; Klebsiella pneumoniae carbapenemase (KPC) [n = 1]). Carbapenemase-producing Proteus were frequently susceptible to ertapenem (26/43; 60%), meropenem (28/43; 65%), ceftazidime (33/43; 77%), and some even to piperacillin-tazobactam (9/43; 21%). Sensitivity/specificity of phenotypic tests were 30% (CI: 17-46%)/89% (CI: 75-97%) for CARBA NP, 74% (CI: 60-85%)/82% (CI: 67-91%) for faropenem, 91% (CI: 78-97%)/82% (CI: 66-92%) for simplified CIM, and 93% (CI: 81-99%)/100% (CI: 91-100%) for modified zinc-supplemented CIM. An algorithm for improved detection was developed, which demonstrated sensitivity/specificity of 100% (CI: 92-100%)/100% (CI: 91-100%) on the 81 isolates, and 100% (CI: 29-100%)/100% (CI: 96-100%) in a prospective analysis of additional 91 isolates. Interestingly, several OXA-23-producing isolates belonged to the same clonal lineage reported previously from France. DISCUSSION: Current susceptibility testing methods and phenotypic tests frequently fail to detect carbapenemases in P. mirabilis, which could result in inadequate antibiotic treatment. In addition, the non-inclusion of blaOXA-23/OXA-58 in many molecular carbapenemase assays further impedes their detection. Therefore, the prevalence of carbapenemases in P. mirabilis is likely underestimated. With the herein proposed algorithm, carbapenemase-producing Proteus can be easily identified.


Assuntos
Proteínas de Bactérias , Proteus mirabilis , Humanos , Proteínas de Bactérias/genética , Proteínas de Bactérias/análise , beta-Lactamases/genética , beta-Lactamases/análise , Antibacterianos/farmacologia , Algoritmos , Zinco , Testes de Sensibilidade Microbiana
2.
J Clin Microbiol ; 56(5)2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29444829

RESUMO

For the rapid detection of carbapenemase-producing Enterobacteriaceae (CPE), immunochromatographic lateral flow tests (ICT) have recently been developed. The aim of this study was to assess the new multiplex ICT Resist-3 O.K.N. and to investigate if it can be performed directly from susceptibility testing plates. Additionally, the impact of the inoculum and carbapenem disks on sensitivity and specificity was evaluated. The new ICT was challenged using 63 carbapenem-resistant Enterobacteriaceae (CRE) isolates, including 51 carbapenemase producers. It was assessed under five different conditions directly from Mueller-Hinton agar (MHA): 1 µl or 10 µl of inoculum harvested in the absence of antibiotic pressure or 1 µl taken from the inhibition zone of either an ertapenem, imipenem, or meropenem disk. The sensitivity of the ICT was 100% for OXA-48-like and KPC carbapenemases and 94.4% for the NDM carbapenemase with the 1-µl inoculum. When harvested adjacent to a carbapenem disk, the sensitivity increased to 100%. Additionally, with zinc-supplemented MHA, both the sensitivity increased and the NDM band became visible faster (mean time, 8 ± 3.9 min for MHA compared to 1.9 ± 1.5 min for MHA plus zinc; P = 0.0016). The specificity of the ICT was 100%. The Resist-3 O.K.N. ICT is a sensitive and rapid test for the detection of three highly prevalent carbapenemases. However, false-negative results for NDM can occur. We recommend an inoculum of 1 µl that is harvested adjacent to an ertapenem or meropenem disk and the use of agars with sufficient zinc content to achieve the best performance.


Assuntos
Técnicas Bacteriológicas/métodos , Enterobacteriáceas Resistentes a Carbapenêmicos/enzimologia , Imunoensaio/métodos , beta-Lactamases/análise , Ágar , Antibacterianos/farmacologia , Enterobacteriáceas Resistentes a Carbapenêmicos/crescimento & desenvolvimento , Ertapenem/farmacologia , Reações Falso-Negativas , Humanos , Imipenem/farmacologia , Meropeném/farmacologia , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA