Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm ; 8(12): 1889-94, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21802390

RESUMO

BACKGROUND: Prediction of sustained ventricular tachycardia (VT)/ventricular fibrillation (VF) could help to guide preventive interventions in at-risk patients. The QRST integral (∫QT) reflects intrinsic repolarization properties. OBJECTIVE: The objective of this study was to determine whether intracardiac ∫QT predicts VT/VF in the next few months in patients with implantable cardioverter defibrillators (ICDs). METHODS: Far-field (FF) and near-field (NF) right ventricular intracardiac electrograms (EGMs) were recorded via telemetry in 46 patients with structural heart disease and ICDs implanted for secondary prevention of sudden cardiac death. Epochs of 4.9 ± 0.4 minutes during sinus rhythm (mean heart rate 70.9 ± 15.2 beats/min) and ventricular pacing at 105 beats/min were analyzed. Mean ∫QT was calculated on FF and NF EGMs as the algebraic sum of areas under the QRST curve and adjusted by mean heart rate. Patients were followed up for at least 3 months. True VT/VF events treated by the ICD served as the end point. RESULTS: During a mean follow-up of 4.6 months, 22 patients (48%) were treated for VT/VF. Unadjusted and adjusted by heart rate, FF EGM ∫QT in sinus rhythm was a significant predictor of VT/VF (unadjusted ∫QT hazard ratio 1.007; 95% confidence interval 1.002 to 1.0013; P = .007; adjusted ∫QT hazard ratio 1.68; 95% confidence interval 1.19 to 2.36; P = .002). The highest quartile of intracardiac ∫QT predicted VT/VF (log-rank test P = .042) and identified patients at risk with a specificity of 86% and positive predictive value of 73%. CONCLUSION: Increased intracardiac FF EGM ∫QT predicts VT/VF in patients with structural heart disease and secondary prevention ICDs.


Assuntos
Desfibriladores Implantáveis , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Idoso , Eletrocardiografia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sensibilidade e Especificidade , Telemetria
2.
Heart Rhythm ; 8(10): 1584-90, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21699842

RESUMO

BACKGROUND: Monitoring arrhythmic risk may improve management of patients with implantable cardioverter-defibrillators (ICD) and prevent ICD shocks. Changes in repolarization duration between subsequent beats quantified as short-term variability (STV) is associated with ventricular arrhythmias in several animal models. OBJECTIVE: We evaluated STV of QT from right ventricular intracardiac ICD electrograms in patients with structural heart disease and compared its predictive value with the QT variability index (QTVI). METHODS: In 233 patients, STV over 60 beats for QT and RR intervals and their ratio was calculated (STV(QT), STV(RR), STV(Ratio), respectively). QTVI was derived from mean and SD of QT and heart rate. Follow-up duration was 26 ± 15 months. Predictive value was determined for sudden arrhythmic death (SAD) defined as sudden cardiac death or fast ventricular tachycardia/fibrillation [CL < 240 ms]. RESULTS: In univariate analysis, STV(Ratio), but not STV(QT) or STV(RR), was predictive of SAD. Hazard ratios for highest quartile STV(Ratio) and QTVI were comparable (STV(Ratio): 1.9, 95% confidence interval [CI] 1.1 to 3.3, P = .038, QTVI: 2.2, 95% CI 1.2 to 3.8, P = .010). In a multivariate model, highest quartile STV(Ratio) was predictive of SAD after adjustment for New York Heart Association class, history of ischemia, ICD indication, and use of class I antiarrhythmics (hazard ratio 1.8, 95% CI 1.0 to 3.4, P < .050). A combined criterion of highest quartile for both STV(Ratio) and QTVI identified patients at highest risk (hazard ratio 2.4, 95% CI 1.3 to 4.3, P = .005, positive predictive value 38%, negative predictive value 82%). CONCLUSION: STV(Ratio) from ICD electrograms is predictive of SAD. Predictive value is similar for order-based STV(Ratio) and distribution-based QTVI, but the combination of both parameters can further improve results.


Assuntos
Morte Súbita Cardíaca/etiologia , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/prevenção & controle
3.
Circulation ; 123(10): 1052-60, 2011 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-21357826

RESUMO

BACKGROUND: T-wave alternans (TWA) increases before ventricular tachycardia (VT) or fibrillation (VF), suggesting that it may warn of VT/VF in implantable cardioverter-defibrillator patients. Recently, we described a method for measuring alternans and nonalternans variability (TWA/V) from electrograms (EGMs) stored in implantable cardioverter-defibrillators before VT/VF. The goal of this prospective, multicenter study was to determine whether EGM TWA/V was greater before VT/VF than at baseline. METHODS AND RESULTS: We enrolled 63 implantable cardioverter-defibrillator patients. TWA/V was computed from stored EGMs before spontaneous VT/VF and from sequential windows of 8 pairs of beats using 4 different control recordings: baseline rhythm, rapid pacing at 105 bpm, segments of ambulatory Holter EGMs matched to the time of VT/VF episodes, and EGMs before spontaneous supraventricular tachycardia. During follow-up, 28 patients had 166 episodes of VT/VF. TWA/V was greater before VT/VF (62.9 ± 3.1 µV; n = 28) than during baseline rhythm (12.8 ± 1.8 µV; P < 0.0001; n = 62), during rapid pacing (14.5 ± 2.0 µV; P < 0.0001; n = 52), before supraventricular tachycardia (27.5 ± 6.1 µV; P < 0.0001; n = 9), or during time-matched ambulatory controls (12.3 ± 3.5 µV; P < 0.0001; n = 16). By logistic regression, the odds of VT/VF increased by a factor of 2.2 for each 10-µV increment in TWA/V (P < 0.0001). CONCLUSIONS: In implantable cardioverter-defibrillator patients, EGM TWA/V is greater before spontaneous VT/VF than in control recordings. Future implantable cardioverter-defibrillators that measure EGM TWA/V continuously may warn patients and initiate pacing therapies to prevent VT/VF.


Assuntos
Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Supraventricular/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA