Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Medicinas Complementares
Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Mov Disord Clin Pract ; 11(1): 69-75, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38291839

RESUMO

BACKGROUND: Magnetic resonance-guided focused ultrasound (MRgFUS) thalamotomy is increasingly used to treat drug-resistant essential tremor (ET). Data on MRgFUS thalamotomy in dystonic tremor (DT) are anecdotal. OBJECTIVES: To investigate efficacy, safety, and differences in target coordinates of MRgFUS thalamotomy in DT versus ET. METHODS: Ten patients with DT and 35 with ET who consecutively underwent MRgFUS thalamotomy were followed for 12 months. Although in both groups the initial surgical planning coordinates corresponded to the ventralis intermediate (Vim), the final target could be modified intraoperatively based on clinical response. RESULTS: Tremor significantly improved in both groups. The thalamic lesion was significantly more anterior in DT than ET. Considering both ET and DT groups, the more anterior the lesion, the lower the odds ratio for adverse events. CONCLUSIONS: MRgFUS thalamotomy is safe and effective in DT and ET. Compared to classical Vim coordinates used for ET, more anterior targeting should be considered for DT.


Assuntos
Tremor Essencial , Humanos , Projetos Piloto , Tremor Essencial/diagnóstico por imagem , Estudos Prospectivos , Tremor , Tálamo/diagnóstico por imagem
2.
Mov Disord ; 37(11): 2289-2295, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36036203

RESUMO

BACKGROUND: Magnetic resonance-guided focused ultrasound (MRgFUS) thalamotomy is a safe and effective procedure for drug-resistant tremor in Parkinson's disease (PD). OBJECTIVE: The aim of this study was to demonstrate that MRgFUS ventralis intermedius thalamotomy in early-stage tremor-dominant PD may prevent an increase in dopaminergic medication 6 months after treatment compared with matched PD control subjects on standard medical therapy. METHODS: We prospectively enrolled patients with early-stage PD who underwent MRgFUS ventralis intermedius thalamotomy (PD-FUS) and patients treated with oral dopaminergic therapy (PD-ODT) with a 1:2 ratio. We collected demographic and clinical data at baseline and 6 and 12 months after thalamotomy. RESULTS: We included 10 patients in the PD-FUS group and 20 patients in the PD-ODT group. We found a significant increase in total levodopa equivalent daily dose and levodopa plus monoamine oxidase B inhibitors dose in the PD-ODT group 6 months after thalamotomy. CONCLUSIONS: In early-stage tremor-dominant PD, MRgFUS thalamotomy may be useful to reduce tremor and avoid the need to increase dopaminergic medications. © 2022 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Assuntos
Tremor Essencial , Doença de Parkinson , Humanos , Tremor/tratamento farmacológico , Tremor/etiologia , Tremor/cirurgia , Doença de Parkinson/tratamento farmacológico , Doença de Parkinson/cirurgia , Tremor Essencial/tratamento farmacológico , Tremor Essencial/cirurgia , Projetos Piloto , Levodopa/uso terapêutico , Tálamo/diagnóstico por imagem , Tálamo/cirurgia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Resultado do Tratamento
3.
Phys Med ; 89: 20-28, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34343763

RESUMO

PURPOSE: In this work, the potential of an innovative "edgeless" silicon diode was evaluated as a response to the still unmet need of a reliable tool for plan dosimetry verification of very high dose, non-coplanar, patient-specific radiosurgery treatments. In order to prove the effectiveness of the proposed technology, we focused on radiosurgical treatments for functional disease like tremor or pain. METHODS: The edgeless diodes response has been validated with respect to clinical practice standard detectors by reproducing the reference dosimetry data adopted for the Treatment Planning System. In order to evaluate the potential for radiosurgery patient-specific treatment plan verification, the anthropomorphic phantom Alderson RANDO has been adopted along with three edgeless sensors, one placed in the centre of the Planning Target Volume, one superiorly and one inferiorly. RESULTS: The reference dosimetry data obtained from the edgeless detectors are within 2.6% for output factor, off-axis ratio and well within 2% for tissue phantom ratio when compared to PTW 60,018 diode. The edgeless detectors measure a dose discrepancy of approximately 3.6% from the mean value calculated by the TPS. Larger discrepancies are obtained in very steep gradient dose regions when the sensors are placed outside the PTV. CONCLUSIONS: The angular independent edgeless diode is proposed as an innovative dosimeter for patient quality assurance of brain functional disorders and other radiosurgery treatments. The comparison of the diode measurements with TPS calculations confirms that edgeless diodes are suitable candidates for patient-specific dosimetric verification in very high dose ranges delivered by non-isocentric stereotactic radiosurgery modalities.


Assuntos
Radiocirurgia , Humanos , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA