Appl Radiat Isot ; 187: 110332, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35717903

RESUMO

Magnetic resonance imaging (MRI) during brachytherapy may alter the dose distribution of radioactive sources implanted in the tumor. This study investigates the impact of a magnetic field of 1.5 T, 3 T, and 7 T strengths on the dose distribution of high dose rate Co-60, Ir-192, and Yb-169, and low dose rate I-125 sources, using Geant4 Monte Carlo toolkit. After validating the simulation results by calculating the AAPM-TG43 dosimetric parameters, seven sources of each radioisotope were simulated in a water phantom, and their dose distributions were compared under the influence of a magnetic field. The simulation results indicate that using Co-60 brachytherapy under the MRI guidance is not recommended. Furthermore, the impact of a magnetic field of up to 7 T strength on the dose distribution of Ir-192, Yb-169, and I-125 sources is negligible, provided that there is no air pocket near brachytherapy sources.


Assuntos
Braquiterapia , Radioisótopos de Irídio , Braquiterapia/métodos , Radioisótopos de Cobalto/uso terapêutico , Radioisótopos do Iodo , Radioisótopos de Irídio/uso terapêutico , Campos Magnéticos , Método de Monte Carlo , Radiometria/métodos , Dosagem Radioterapêutica