Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Lasers Med Sci ; 37(6): 2645-2653, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35257243

RESUMO

To investigate whether low-level laser therapy (LLLT), at different times of application (immediate and late) in the region of the parotid glands, has a distance effect on the microarchitecture of the trabecular bone in mandible of rats irradiated by volumetric modular arc therapy (VMAT). Thirty adult Wistar rats were randomly divided into placebo control groups (CG, n = 2), only radiotherapy (RG, n = 2), only LPLT (LG, n = 2), and two other groups using LLLT in the immediate time (24 h) (ILG, n = 12) and late (120 h) (LLG, n = 12) to radiotherapy by VMAT in a single dose of 12 Gy. LLLT with AsGaAl laser (660 nm, 100 mW), a spot size of 0.0028 cm2, was applied in three points in the region of the right parotid gland, with energy of 2 J/cm2, 20 s per point, for 10 consecutive days. After euthanasia, the right hemimandibles of each animal were dissected, prepared, and analyzed by computerized microtomography (micro-CT) and histomorphometry. The different groups were analyzed by the Tukey and Bonferroni multiple comparison tests. The micro-CT analysis found statistically significant differences between the groups, especially in the LLG, which had the highest average bone volume compared to the CG (p = 0.001) and ILG (p = 0.002) and a greater number of trabeculae than the CG (p = 0.000) and ILG (p = 0.031). The ILG also had a higher number of trabeculae than the CG (p = 0.005). Trabecula separation (Tb.Sp) was lower in the LLG (p = 0.000) and ILG (p = 0.002) when compared to the CG. In the histomorphometry, there was no statistical difference between the groups in relation to all the analyzed variables. Micro-CT analysis showed that the LLLT, even applied at a distance, both in the immediate and late VMAT times, has an effect on the mandibular bone microarchitecture by increasing the volume and number of trabeculae and decreasing the spaces between them.


Assuntos
Terapia com Luz de Baixa Intensidade , Animais , Osso Esponjoso , Terapia com Luz de Baixa Intensidade/métodos , Mandíbula/diagnóstico por imagem , Ratos , Ratos Wistar , Microtomografia por Raio-X
2.
J Lasers Med Sci ; 12: e45, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34733768

RESUMO

Introduction: This study aimed to investigate the effect of low-level laser therapy (LLLT) on the blood cell count when applied to parotid glands of rats irradiated by volumetric modular arc therapy (VMAT). Methods: Thirty-two adult male Wistar rats were used in this study. Samples were randomly assigned to three groups: control group (CG, n = 8), immediate laser group (24 hours) (ILG, n=12), and late laser group (120 hours) (LLG, n=12). The two laser groups were previously subjected to VMAT radiotherapy in a single dose of 12 Gy. LLLT with an AsGaAl laser (660 nm, 100 mW) was applied at three points in the region of the parotid glands, right side, with the energy of 2 J per point (20s, 70 J/cm2) and a spot size of 0.0028 cm2 for 10 consecutive days. In the euthanasia, blood samples were obtained by cardiac puncture. The samples from each group were processed by an automatic method and analyzed for erythrogram, leukogram and platelet count values. The data were analyzed by ANOVA and each LLLT time point was analyzed in relation to the control group, with a significance level less than 0.05. Results: Groups using LLLT had higher red blood cell counts, being higher in the LLG (P = 0.000). The hematimetric indices MCV (P = 0.002) and MCH (P = 0.009) were lower than the control group, especially when compared to the group using LLLT 120h after radiotherapy (LLG). White blood cell counts were lower in the groups with radiotherapy and immediate use of LLLT (ILG) (P = 0.011), mainly at the expense of lymphocytes (P = 0.002). Conclusion: The results suggest a potential systemic effect of LLLT, especially on circulating red blood cell counts, regardless of their time of immediate or late use of radiotherapy.

3.
J Lasers Med Sci ; 11(3): 262-267, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32802285

RESUMO

Introduction: This experimental study investigated the mRNA expression of aquaporins (AQPs) 1 and 5 in the parotid glands of rats irradiated with volumetric modulated arc therapy (VMAT) and subjected to low-level laser therapy (LLLT) at different time points. Methods: The sample consisted of 30 Wistar rats (Rattus norvegicus) divided into the following groups: control, LLLT alone (LG), radiotherapy alone (RG), and experimental groups that received LLLT at 24 hours (early experimental group [EEG], n=12) and 120 hours (late experimental group [LEG], n=12) after radiotherapy. VMAT was delivered at a single dose (12 Gy) and LLLT was performed with an aluminium-gallium-arsenide diode laser (660 nm, 100 mW), spot area of 0.0028 cm2, energy of 2 J/cm2 applied to 3 spots in the region corresponding to the right parotid gland, for 10 consecutive days. The right parotid gland was resected and prepared for RNA extraction. The gene expression of AQPs was evaluated by quantitative polymerase chain reaction (qPCR) using specific TaqMan probes, with the HPRT gene as an internal control. Results: The lowest AQP1 gene expression was 0.83 (0.27) with the use of LLLT 24 hours after radiotherapy (EEG), and the highest was 1.56 (0.80) with the use of LLLT alone (LG). Likewise, the lowest AQP5 gene expression was found in the EEG (mean = 0.88; SD = 0.49) and the highest in the LG (mean = 1.29; SD = 0.33). Conclusion: The use of LLLT after radiotherapy may contribute to the maintenance and an increase of these proteins, even when used at a later time point after radiotherapy.

4.
J Oral Implantol ; 39(5): 533-8, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21534821

RESUMO

The present study measured removal torque and bone-implant interface resistance of machined implants, acid-etched implants, or machined implants irradiated around the implant area with infrared low-level laser therapy (LLLT; 830 nm) immediately after surgery. There were statistically significant differences between Groups A (control) and B (rough surface) (P = .03). Implants with a rough surface seem to add resistance to the bone-implant interface compared with smooth titanium implants or implants treated with LLLT.


Assuntos
Implantes Dentários , Remoção de Dispositivo , Osseointegração/efeitos da radiação , Análise de Variância , Animais , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Fêmur , Terapia com Luz de Baixa Intensidade , Ratos , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos da radiação , Torque
5.
J Craniofac Surg ; 23(1): 145-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22337393

RESUMO

Treatment of facial trauma sequelae is a complex and challenging process. There is still controversy over suitable materials for orbital wall reconstruction. This study evaluated calcium phosphate cement (CPC) implants manufactured by rapid prototyping in the repair of orbital wall defects secondary to trauma. Computed tomographic scans of 5 patients were used for surgery planning and production of CPC implants. Implants were used to restore orbital wall anatomy, ocular alignment, and facial contour. Benefits resulting from the use of implants, such as a reduced operating time, patient response to biomaterial implantation, biomaterial integrity and stability, and patient satisfaction with treatment, were analyzed qualitatively. Our results suggest that CPC is an effective and safe material for orbital reconstruction because of its biocompatibility and easy production and placement.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Substitutos Ósseos/uso terapêutico , Fosfatos de Cálcio/uso terapêutico , Órbita/cirurgia , Fraturas Orbitárias/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Próteses e Implantes , Adulto , Materiais Biocompatíveis/química , Substitutos Ósseos/química , Fosfatos de Cálcio/química , Sulfato de Cálcio/química , Desenho Assistido por Computador , Diplopia/cirurgia , Enoftalmia/cirurgia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Transtornos da Motilidade Ocular/cirurgia , Doenças Orbitárias/cirurgia , Planejamento de Assistência ao Paciente , Segurança do Paciente , Satisfação do Paciente , Fosfatos/química , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Tomografia Computadorizada Espiral , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA