Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Medicinas Complementares
Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 199(12): 1310-1323, 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37345708

RESUMO

During the early response to large-scale radioactive contamination events, people who are potentially affected need to be screened for radioactive contamination and public health staff need to triage individuals who may need immediate decontamination. This is typically done by screening individuals for external contamination using ionising radiation detection equipment. In this study, spatially and temporally dependent isotopic compositions from a simulated nuclear detonation and Monte Carlo methods were used to relate contamination activity levels to the measurable radiation levels at select distances away from an individual with whole-body contamination. Radionuclide-specific air kerma rate coefficients and Geiger-Mueller instrument response coefficients at five select distances from contaminated individuals are presented for 662 radionuclides. Temporally and spatially dependent incident-specific coefficients are presented for a hypothetical surface detonation of a 235U-fueled device.


Assuntos
Monitoramento de Radiação , Urânio , Humanos , Radioisótopos/análise , Triagem/métodos , Doses de Radiação
2.
Radiat Prot Dosimetry ; 115(1-4): 298-301, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16381733

RESUMO

In the past, some privately owned commercial facilities in the United States were involved in producing or processing radioactive materials used in the production of atomic weapons. Seven different geometrical objects, representative of the configurations of natural uranium metal potentially encountered by workers at these facilities, are modelled to determine gamma ray and bremsstrahlung dose rates. The dose rates are calculated using the MCNP5 code and also by using the MICROSHIELD point-kernel code. Both gamma ray and bremsstrahlung dose rates are calculated and combined to obtain a total dose rate. The two methods were found to be in good agreement despite differences in modelling assumptions and method differences. Computed total dose rates on the surface of these objects ranged from approximately 51-84 microSv h(-1) and 17-95 microSv h(-1) using the MCNP5 and the MICROSHIELD modeling, respectively. The partitioning of the computed dose rates between gamma rays and bremsstrahlung were the same order of magnitude for each object.


Assuntos
Modelos Estatísticos , Reatores Nucleares , Exposição Ocupacional/análise , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Medição de Risco/métodos , Urânio/análise , Simulação por Computador , Raios gama , Humanos , Guerra Nuclear , Fótons , Doses de Radiação , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA