RESUMO
BACKGROUND: Conventional percutaneous endoscopic lumbar discectomy (PELD) with an "inside-outside" technique has 4.3% - 10.3% surgical failure rate, especially in central herniated discs (HDs), migrated HDs, and axillary type HDs. PELD with foraminoplasty has been used for complex HDs. Percutaneous lumbar foraminoplasty (PLF), which is performed with a trephine or bone reamer introduced over a guidewire without a protective working cannula in the original Tessys technique, can quickly cut the hypertrophied bony structure under fluoroscopic guidance, and risk injury to the exiting and traversing nerve roots. STUDY DESIGN: A prospective cohort study. SETTING: Hospital and outpatient surgical center. OBJECTIVE: To evaluate the outcome and safety of modified PLF-PELD with a specially designed instrument for complex uncontained lumbar HDs. METHOD: From April of 2007 to April of 2009, 148 patients with uncontained lumbar HDs were treated with modified PLF-PELD. Magnetic resonance imaging (MRI) checkup was performed the next morning after the operation. Outcomes of symptoms were evaluated by follow-up interviews at 3 months, 6 months, one year, and 5 years after surgery. Low back pain and leg pain were measured by visual analog scale (VAS) score (1 - 100). Functional outcomes were assessed by using the Oswestry Disability Index (ODI) and modified MacNab criteria. RESULTS: Follow-up data were obtained from 134 cases, including 14 cases on L3-4, 78 cases on L4-5, and 42 cases on L5-S1. One hundred-eight cases were prolapse type, while 26 cases were sequestration type. Pre-operative symptoms and deficits included nerve root dermatome hypoesthesia in 98 patients (73%), nerve root myotome muscle weakness in 32 patients (23%), and weakening or disappearance of tendon reflex in 43 patients (32%). No case required conversion to an open procedure during the surgery. Low back pain and leg pain were significantly relieved immediately after surgery in all patients. MRI examination showed adequate removal of HD in all patients. VAS scores and ODI values were significantly lower at all time points after surgery than before surgery. The percentage of pain relief in leg pain was significantly higher than that in low back pain (P < 0.01). But there was no significant correlation between duration of the preoperative symptoms and the percentage of pain relief. MacNab scores at 5 years after surgery were obtained from 134 patients. Seventy-five cases were rated "excellent"; 49 were rated "good," Five patients experienced heavier low back pain, thus being classified as "fair." Five cases with recurrence were rated "poor." Preoperative and postoperative (5 years follow-up) related nerve root function status was compared. Sensation and muscle strength recovered significantly (P < 0.01), while tendon reflex was not changed (P = 0.782). No patients had infections. Five patients were complicated with dysesthesia in distribution of the exiting nerve that was all operated at L5-S1. Complaints were reduced one week after treatment with medium frequency pulse electrotherapy. Five cases required a revision surgery after recurrence. LIMITATIONS: This is an observational clinical case series study without comparison. CONCLUSION: Modified PLF-PELD with a specially designed instrument is a less invasive, effective and safe surgery for complex uncontained lumbar DH.Key words: Lumbar disc herniation, minimally invasive treatment, foraminoplasty, percutaneous endoscopic lumbar discectomy.
Assuntos
Discotomia Percutânea/instrumentação , Discotomia Percutânea/métodos , Endoscopia , Foraminotomia/instrumentação , Foraminotomia/métodos , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Humanos , Dor Lombar/cirurgia , Masculino , Pessoa de Meia-Idade , Manejo da Dor , Estudos Prospectivos , Estudos Retrospectivos , Ciática/cirurgia , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND AND PURPOSE: Accumulating evidence indicates an important role of oxidative stress in the progression of osteoporosis. Recently, it was demonstrated that hydrogen gas, as a novel antioxidant, could selectively reduce hydroxyl radicals and peroxynitrite anion to exert potent therapeutic antioxidant activity. The aim of the present work was to investigate the effect of hydrogen water (HW) consumption on ovariectomy-induced osteoporosis. EXPERIMENTAL APPROACH: Ovariectomized rats were fed with HW (1.3 ± 0.2 mg·L⻹) for 3 months. Then, blood was collected and femur and vertebrae were removed for evaluation of the effect of HW on bone. KEY RESULTS: HW consumption in ovariectomized rats had no significant effect on oestrogen production, but prevented the reduction of bone mass including bone mineral content and bone mineral density in femur and vertebrae, and preserved mechanical strength including ultimate load, stiffness, and energy, and bone structure including trabecular bone volume fraction, trabecular number, and trabecular thickness in femur, and preserved mechanical strength including ultimate load and stiffness, and bone structure including trabecular bone volume fraction and trabecular number in vertebrae. In addition, treatment with HW abated oxidative stress and suppressed IL-6 and TNF-α mRNA expressions in femur of ovariectomized rats; treatment with HW increased femur endothelial NOS activity and enhanced circulating NO level in ovariectomized rats. CONCLUSIONS AND IMPLICATIONS: HW consumption prevents osteopenia in ovariectomized rats possibly through the ablation of oxidative stress induced by oestrogen withdrawal.