Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 35(2): e4972, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32840880

RESUMO

This study developed a two-dimensional heart-cutting LC method for the separation of amino acid enantiomers. Two approaches for achiral separation of amino acids, phenylalanine and tryptophan, were selected. Amino acids were separated on C18 or hydrophilic interaction liquid chromatography (HILIC) columns in first dimension after their enantiomer separation on a teicoplanin chiral column in second dimension. Mobile phases for both separation systems were optimized by testing different types of organic modifiers, concentrations of ion-pair agent (sodium 1-octanesulfonate), and ionic modifier (ammonium acetate). The resolution of enantiomers higher than 1.5 for both amino acids was achieved using a C18-teicoplanin coupled column separation system with mobile phases methanol/2 mM sodium 1-octanesulfonate (10:90 and 75:25, step gradient between achiral and chiral columns, respectively). The lower resolution of amino acid enantiomers (RS ˃ 0.9), but higher column efficiency, was achieved on a HILIC-teicoplanin separation system with mobile phases acetonitrile/50 mM ammonium acetate (90:10 and 80:20, step gradient between achiral and chiral columns, respectively). The developed heart-cutting 2D-LC methods were validated in terms of linearity, limit of detection, limit of quantification, precision, and accuracy. The results suggested that the developed methods were applicable for the simultaneous determination of amino acid enantiomers in the dietary supplement. The sample contained l-phenylalanine and l-tryptophan.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Suplementos Nutricionais/análise , Fenilalanina , Triptofano , Limite de Detecção , Modelos Lineares , Fenilalanina/análise , Fenilalanina/química , Fenilalanina/isolamento & purificação , Reprodutibilidade dos Testes , Estereoisomerismo , Triptofano/análise , Triptofano/química , Triptofano/isolamento & purificação
2.
Ceska Slov Farm ; 66(2): 62-66, 2017.
Artigo em Tcheco | MEDLINE | ID: mdl-28914062

RESUMO

The paper deals with enantioselective separation of amino acids by the high performance liquid chromatography method. Separations of enantiomeric forms were tested on the chiral stationary phases based on ß-cyclodextrine, isopropyl carbamate cyclofructan 6, and the macrocyclic antibiotic teicoplanin. The best enantioseparation was obtained on the teicoplanin-based chiral stationary phase in the reversed-phase mode. UV spectrophotometric detection at 210 nm was used for detection of amino acids. The method was validated with respect to linearity, precision, limit of detection, limit of quantitation, and recovery. Limits of quantitation for phenylalanine and methionine enantiomers were 0.3 and 0.2 µg.ml-1, respectively. The HPLC method with teicoplanin-based chiral stationary phase was applied for analysis of dietary supplements.Key words: separation of enantiomers HPLC phenylalanine methionine.


Assuntos
Cromatografia Líquida de Alta Pressão , Metionina/isolamento & purificação , Fenilalanina/isolamento & purificação , Carbamatos , Frutanos , Estereoisomerismo , Teicoplanina , beta-Ciclodextrinas
3.
J Fluoresc ; 25(2): 297-303, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25595059

RESUMO

At present, it is necessary to check the quality of many food products in which the content of coumarins is limited. Since a rapid and simple method for the determination of coumarin (COU), 4-hydroxycoumarin (4HC) and dicoumarol (DC) in tea samples was needed, we developed an alternative option to chromatography, i.e., fluorescence spectroscopy with multivariate calibration. The synchronous fluorescence spectra were recorded at constant wavelength differences 70, 80 and 90 nm from 200 to 400 nm. The different experimental parameters affecting the synchronous fluorescence intensities of the analytes were carefully studied and optimized. Partial least squares (PLS) method and multi linear regression (MLR) were compared on determining the concentrations. The best results were obtained by the PLS method on synchronous fluorescence spectra at Δλ = 90 nm. The results from the analysis of herbal tea Melilotus officinalis by synchronous fluorescence spectroscopy with PLS model are equivalent with the results from HPLC. Fisher F-test and Student's t-test confirmed this finding.


Assuntos
Cumarínicos/análise , Espectrometria de Fluorescência/métodos , Calibragem , Cumarínicos/química , Concentração de Íons de Hidrogênio , Análise dos Mínimos Quadrados , Modelos Lineares , Análise Multivariada , Solventes/química , Chás de Ervas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA